CoChat

Longitudinally implanted intrafascicular electrodes for stimulating and recording fascicular physioelectrical signals in the sciatic nerve of rabbits

Zheng, Xiujun, Zhang, Jian, Chen, Tongyi, Chen, Zhongwei · 2003 · Microsurgery
Cited by 22

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The purpose of this experiment was to determine the stimulating and recording characters of fascicular physioelectrical signals in the activity of peripheral nerves by longitudinally implanted intrafascicular electrodes (LIFEs) in a rabbit sciatic nerve model, and discuss the future application of LIFEs in functional electrical stimulation (FES) and control of electric arm prosthesis. In methodology, LIFEs were inserted into the fasciculus of the sciatic nerves of rabbits and used as recording electrodes and stimulating electrodes, respectively. Motor‐evoked potentials (MEPs), cortical somatosensory‐evoked potentials (CSEPs), and electromyography (EMG) were recorded by using a transcranial stimulation system (TCS). LIFEs were found to have stable stimulating and recording characters. The interpeak amplitudes (IPAs) of MEPs ranged from 78–156 μV (mean ± SD, 102 ± 23.2 μV). The onset latency (OL) of MEPs ranged from 9.8–11.2 msec (mean ± SD, 10.8 ± 0.6 msec). The interpeak amplitudes (IPAs) of CSEPs ranged from 5.8–7.2 μV (mean ± SD, 6.7 ± 0.5 μV). The onset latency (OL) of CSEPs ranged from 11.4–14.6 msec (mean ± SD, 12.8 ± 1.3 msec). EMGs could be recorded in the gastrocnemius, but could not be recorded in the tibialis anterior muscle. In conclusion, longitudinally implanted intrafascicular electrodes can act as intrafascicular stimulating and recording electrodes with high selective characters. They can provide a new way to study fascicular physioelectrical signals and their function in the activity of peripheral nerves. © 2003 Wiley‐Liss, Inc. MICROSURGERY 23:268–273 2003

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/micr.10116

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 22

Metadata

Authors
Zheng, X., Zhang, J., Chen, T., & Chen, Z.
Venue
Microsurgery
Publisher
Wiley
Published
2003-01
Volume
23
Issue
3
Pages
268-273
ISSN
  • 0738-1085 (ISSN-L)
  • 1098-2752
OpenAlex
W1989492476
Cited by
22
References
7
FWCI
0.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Longitudinally implanted intrafascicular electrodes for stimulating and recording fascicular physioelectrical signals in the sciatic nerve of rabbits. https://app.cochat.ai/papers/10.1002/micr.10116
The paper
Zheng, X., Zhang, J., Chen, T., & Chen, Z. (2003). Longitudinally implanted intrafascicular electrodes for stimulating and recording fascicular physioelectrical signals in the sciatic nerve of rabbits. Microsurgery. https://doi.org/10.1002/micr.10116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.