The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Abstract
In this study, a novel partially parallel acquisition (PPA) method is presented which can be used to accelerate image acquisition using an RF coil array for spatial encoding. This technique, GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) is an extension of both the PILS and VD‐AUTO‐SMASH reconstruction techniques. As in those previous methods, a detailed, highly accurate RF field map is not needed prior to reconstruction in GRAPPA. This information is obtained from several k‐space lines which are acquired in addition to the normal image acquisition. As in PILS, the GRAPPA reconstruction algorithm provides unaliased images from each component coil prior to image combination. This results in even higher SNR and better image quality since the steps of image reconstruction and image combination are performed in separate steps. After introducing the GRAPPA technique, primary focus is given to issues related to the practical implementation of GRAPPA, including the reconstruction algorithm as well as analysis of SNR in the resulting images. Finally, in vivo GRAPPA images are shown which demonstrate the utility of the technique. Magn Reson Med 47:1202–1210, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Partially parallel imaging with localized sensitivities (PILS)
Griswold, M. A., Jakob, P. M., Nittka, M., Goldfarb, J. W., & Haase, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<602::aid-mrm14>3.0.co;2-5 · Cited by 329
Self-citationAUTO-SMASH: A self-calibrating technique for SMASH imaging
Jakob, P. M., Grisowld, M. A., Edelman, R. R., & Sodickson, D. K. (1998) · Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine · doi:10.1007/bf02592256 · Cited by 278
Self-citationHeidemann, R. M., Griswold, M. A., Haase, A., & Jakob, P. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1141 · Cited by 228
Self-citationFast imaging using subencoding data sets from multiple detectors
Ra, J. B., & Rim, C. Y. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300123 · Cited by 163
Imaging time reduction through multiple receiver coil data acquisition and image reconstruction
Carlson, J. W., & Minemura, T. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290516 · Cited by 130
Bydder, M., Larkman, D. J., & Hajnal, J. V. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10044 · Cited by 107
Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging
Sodickson, D. K., Griswold, M. A., Jakob, P. M., Edelman, R. R., & Manning, W. J. (1999) · Magnetic Resonance in Medicine · Cited by 99
Self-citation
Cited by
Items 101–124 of 124
WONDERLICK, J., ZIEGLER, D., HOSSEINIVARNAMKHASTI, P., LOCASCIO, J., BAKKOUR, A., VANDERKOUWE, A., TRIANTAFYLLOU, C., CORKIN, S., & DICKERSON, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.037 · Cited by 221
Quantitative susceptibility mapping using deep neural network: QSMnet
Yoon, J., Gong, E., Chatnuntawech, I., Bilgic, B., Lee, J., Jung, W., Ko, J., Jung, H., Setsompop, K., Zaharchuk, G., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.030 · Cited by 185
Neural mechanisms underlying changes in stress-sensitivity across the menstrual cycle
Ossewaarde, L., Hermans, E. J., van Wingen, G. A., Kooijman, S. C., Johansson, I.-M., Bäckström, T., & Fernández, G. (2010) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2009.08.011 · Cited by 185
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
Self-citationLinear inverse problems in imaging
Ribes, A., & Schmitt, F. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.923099 · Cited by 154
Fear bradycardia and activation of the human periaqueductal grey
Hermans, E. J., Henckens, M. J. A. G., Roelofs, K., & Fernández, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.063 · Cited by 151
Oxytocin Modulates Neural Reactivity to Children's Faces as a Function of Social Salience
Wittfoth-Schardt, D., Gründing, J., Wittfoth, M., Lanfermann, H., Heinrichs, M., Domes, G., Buchheim, A., Gündel, H., & Waller, C. (2012) · Neuropsychopharmacology · doi:10.1038/npp.2012.47 · Cited by 139
Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques
Fritz, J., Guggenberger, R., & Grande, F. D. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.20.22902 · Cited by 121
Evolution of white matter tract microstructure across the life span
Slater, D. A., Melie‐Garcia, L., Preisig, M., Kherif, F., Lutti, A., & Draganski, B. (2019) · Human Brain Mapping · doi:10.1002/hbm.24522 · Cited by 119
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Implicit data crimes: Machine learning bias arising from misuse of public data
Shimron, E., Tamir, J. I., Wang, K., & Lustig, M. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2117203119 · Cited by 112
van der Schaaf, M. E., van Schouwenburg, M. R., Geurts, D. E. M., Schellekens, A. F. A., Buitelaar, J. K., Verkes, R. J., & Cools, R. (2014) · Cerebral Cortex · doi:10.1093/cercor/bhs344 · Cited by 102
Demiral, Ş. B., Tomasi, D., Sarlls, J., Lee, H., Wiers, C. E., Zehra, A., Srivastava, T., Ke, K., Shokri-Kojori, E., Freeman, C. R., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.043 · Cited by 110
Ekstrom, L. B., Roelfsema, P. R., Arsenault, J. T., Kolster, H., & Vanduffel, W. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.0673-09.2009 · Cited by 83
Action-specific value signals in reward-related regions of the human brain
FitzGerald, T. H. B., Friston, K. J., & Dolan, R. J. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3254-12.2012 · Cited by 68
Kumral, D., Schaare, H. L., Beyer, F., Reinelt, J., Uhlig, M., Liem, F., Lampe, L., Babayan, A., Reiter, A., Erbey, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.027 · Cited by 64
Direct parametric reconstruction from undersampled (k,t)-space data in dynamic contrast enhanced MRI
Dikaios, N., Arridge, S., Hamy, V., Punwani, S., & Atkinson, D. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.05.001 · Cited by 40
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Clos, M., Bunzeck, N., & Sommer, T. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.0495-19.2019 · Cited by 32
Svedin, B. T., Payne, A., & Parker, D. L. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25860 · Cited by 30
de Riedmatten, I., Spencer, A. P. C., Olszowy, W., & Jelescu, I. O. (2025) · Communications Biology · doi:10.1038/s42003-025-07889-0 · Cited by 12
Mapping grey and white matter activity in the human brain with isotropic ADC-fMRI
Spencer, A. P. C., Nguyen-Duc, J., de Riedmatten, I., Szczepankiewicz, F., & Jelescu, I. O. (2025) · Nature Communications · doi:10.1038/s41467-025-60357-5 · Cited by 12
Evaluating the dependence of ADC-fMRI on haemodynamics in breath-hold and resting-state conditions
de Riedmatten, I., Spencer, A. P. C., Nguyen-Duc, J., Pérot, J.-B., Szczepankiewicz, F., Esteban, O., & Jelescu, I. O. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.1020 · Cited by 4
Metadata
- Authors
- Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-06
- Volume
- 47
- Issue
- 6
- Pages
- 1202-1210
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2111388536
- Cited by
- 5,303
- References
- 12
- FWCI
- 49.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.