Microvascular BOLD contribution at 4 and 7 T in the human brain: Gradient‐echo and spin‐echo fMRI with suppression of blood effects
Abstract
The BOLD signal consists of an intravascular (IV) and an extravascular (EV) component from both small and large vessels. Their relative contributions are dependent on field strength, imaging technique, and echo time. The IV and EV contributions were investigated in the human visual cortex at 4 and 7 T using spin‐echo and gradient‐echo BOLD fMRI with and without suppression of blood effects. Spin‐echo acquisition suppresses EV BOLD from large veins and reflects predominantly blood T2 changes and EV BOLD signal from small blood vessels. At a short echo time (32 ms), diffusion gradient‐based suppression of blood signals resulted in a 75% and 20% decrease in spin‐echo BOLD changes at 4 T and 7 T, respectively. However, at echo times (55–65 ms) approximating tissue T2 typically used for optimal BOLD contrast, these gradients had much smaller effects at both fields, consistent with the decreasing blood T2 with increasing field strength. Gradient‐echo BOLD percent changes, with relatively long echo times at both fields, were virtually unaffected by gradients that attenuated the blood contribution because the EV BOLD surrounding both large and small vessels dominated. These results suggest that spin‐echo BOLD fMRI at 4 and 7 T, with TE approximating tissue T2, significantly reduces nonspecific mapping signals from large vessels and significantly accentuates microvasculature contributions. Magn Reson Med 49:1019–1027, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationThulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Boxerman, J. L., Bandettini, P. A., Kwong, K. K., Baker, J. R., Davis, T. L., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340103 · Cited by 594
Luz, Z., & Meiboom, S. (1963) · The Journal of Chemical Physics · doi:10.1063/1.1734254 · Cited by 546
Intravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448
Self-citationLai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Cited by
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationBiophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Self-citationPros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
What can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Self-citationLaminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1
Polimeni, J. R., Fischl, B., Greve, D. N., & Wald, L. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.005 · Cited by 431
Yacoub, E., Shmuel, A., Logothetis, N., & Uğurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.020 · Cited by 308
Self-citationHigh magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo
de Graaf, R. A., Brown, P. B., McIntyre, S., Nixon, T. W., Behar, K. L., & Rothman, D. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20946 · Cited by 304
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Le Bihan, D. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 298
Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N. K., & Ugurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.030 · Cited by 294
Self-citationfMRI at 1.5, 3 and 7 T: Characterising BOLD signal changes
van der Zwaag, W., Francis, S., Head, K., Peters, A., Gowland, P., Morris, P., & Bowtell, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.015 · Cited by 281
Direct and fast detection of neuronal activation in the human brain with diffusion MRI
Le Bihan, D., Urayama, S.-I., Aso, T., Hanakawa, T., & Fukuyama, H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600644103 · Cited by 272
Zhao, F., Wang, P., Hendrich, K., Ugurbil, K., & Kim, S.-G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.013 · Cited by 266
Self-citationUltrahigh field magnetic resonance imaging and spectroscopy
Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.027 · Cited by 252
Self-citationShmuel, A., Chaimow, D., Raddatz, G., Ugurbil, K., & Yacoub, E. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.040 · Cited by 111
Self-citationBartelle, B. B., Barandov, A., & Jasanoff, A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.4050-15.2016 · Cited by 45
Febo, M. (2011) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2011.00043 · Cited by 43
Kenkel, W. M., Yee, J. R., Moore, K., Madularu, D., Kulkarni, P., Gamber, K., Nedelman, M., & Ferris, C. F. (2016) · Translational Psychiatry · doi:10.1038/tp.2016.15 · Cited by 39
Kohno, S., Sawamoto, N., Urayama, S.-I., Aso, T., Aso, K., Seiyama, A., Fukuyama, H., & Le Bihan, D. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.45 · Cited by 30
Metadata
- Authors
- Duong, T. Q., Yacoub, E., Adriany, G., Hu, X., Uǧurbil, K., & Kim, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-05-16
- Volume
- 49
- Issue
- 6
- Pages
- 1019-1027
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2108049514
- Cited by
- 360
- References
- 36
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.