The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Microvascular BOLD contribution at 4 and 7 T in the human brain: Gradient‐echo and spin‐echo fMRI with suppression of blood effects
Abstract
The BOLD signal consists of an intravascular (IV) and an extravascular (EV) component from both small and large vessels. Their relative contributions are dependent on field strength, imaging technique, and echo time. The IV and EV contributions were investigated in the human visual cortex at 4 and 7 T using spin‐echo and gradient‐echo BOLD fMRI with and without suppression of blood effects. Spin‐echo acquisition suppresses EV BOLD from large veins and reflects predominantly blood T2 changes and EV BOLD signal from small blood vessels. At a short echo time (32 ms), diffusion gradient‐based suppression of blood signals resulted in a 75% and 20% decrease in spin‐echo BOLD changes at 4 T and 7 T, respectively. However, at echo times (55–65 ms) approximating tissue T2 typically used for optimal BOLD contrast, these gradients had much smaller effects at both fields, consistent with the decreasing blood T2 with increasing field strength. Gradient‐echo BOLD percent changes, with relatively long echo times at both fields, were virtually unaffected by gradients that attenuated the blood contribution because the EV BOLD surrounding both large and small vessels dominated. These results suggest that spin‐echo BOLD fMRI at 4 and 7 T, with TE approximating tissue T2, significantly reduces nonspecific mapping signals from large vessels and significantly accentuates microvasculature contributions. Magn Reson Med 49:1019–1027, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationThulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Boxerman, J. L., Bandettini, P. A., Kwong, K. K., Baker, J. R., Davis, T. L., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340103 · Cited by 594
Luz, Z., & Meiboom, S. (1963) · The Journal of Chemical Physics · doi:10.1063/1.1734254 · Cited by 546
Intravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448
Self-citationLai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Bandettini, P. A., Wong, E. C., Jesmanowicz, A., Hinks, R. S., & Hyde, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070104 · Cited by 349
ON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
Self-citationLocalized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Self-citationEstimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Spin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308
Self-citationDiffusion-weighted spin-echo fMRI at 9.4 T: Microvascular/tissue contribution to BOLD signal changes
Lee, S.-P., Silva, A. C., Ugurbil, K., & Kim, S.-G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<919::aid-mrm12>3.0.co;2-8 · Cited by 288
Self-citationOgawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
Kim, S.-G., Rostrup, E., Larsson, H. B. W., Ogawa, S., & Paulson, O. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1152::aid-mrm11>3.0.co;2-t · Cited by 268
Self-citationDuong, T. Q., Silva, A. C., Lee, S.-P., & Kim, S.-G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<383::aid-mrm10>3.0.co;2-q · Cited by 254
Self-citationDiffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208
Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
Darquié, A., Poline, J.-B., Poupon, C., Saint-Jalmes, H., & Le Bihan, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.151125698 · Cited by 194
Duong, T. Q., Kim, D.-S., U?urbil, K., & Kim, S.-G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<231::aid-mrm10>3.0.co;2-t · Cited by 182
Self-citationFunctional mapping in the human brain using high magnetic fields
Uǧurbil, K., Hu, X. P., Chen, W., Zhu, X.-H., Kim, S., & Georgopoulos, A. P. (1999) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1999.0474 · Cited by 159
Self-citationMagnetic relaxation in blood and blood clots
Bryant, R. G., Marill, K. A., Blackmore, C. C., & Francis, C. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130112 · Cited by 136
In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain
Duong, T. Q., & Kim, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<393::aid-mrm11>3.0.co;2-k · Cited by 128
Self-citationHaacke, E. M., Lai, S., Yablonskiy, D. A., & Lin, W. (1995) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850060204 · Cited by 120
Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI.
Barth, M., & Moser, E. (1997) · PubMed · Cited by 118
Bartha, R., Michaeli, S., Merkle, H., Adriany, G., Andersen, P., Chen, W., Uǧurbil, K., & Garwood, M. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10112 · Cited by 116
Self-citationVenous blood effects in spin-echo fMRI of human brain
Oja, J. M. E., Gillen, J., Kauppinen, R. A., Kraut, M. A., & van Zijl, P. C. M. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199910)42:4<617::aid-mrm1>3.0.co;2-q · Cited by 113
Quantitative differentiation between BOLD models in fMRI
Hoogenraad, F. G. C., Pouwels, P. J. W., Hofman, M. B. M., Reichenbach, J. R., Sprenger, M., & Haacke, E. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<233::aid-mrm1032>3.0.co;2-w · Cited by 105
T1 and T2 measurements on a 1.5-T commercial MR imager.
Breger, R. K., Rimm, A. A., Fischer, M., Papke, R. A., & Haughton, V. M. (1989) · Radiology · doi:10.1148/radiology.171.1.2928538 · Cited by 104
A quantitative interpretation of IVIM measurements of vascular perfusion in the rat brain
Henkelman, R. M., Neil, J. J., & Xiang, Q. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320407 · Cited by 104
NMR relaxation rates and blood oxygenation level
Meyer, M. ‐., Yu, O., Eclancher, B., Grucker, D., & Chambron, J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340215 · Cited by 89
Comparison of diffusion‐weighted high‐resolution CBF and spin‐echo BOLD fMRI at 9.4 T
Lee, P., Silva, A. C., & Kim, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10117 · Cited by 71
Self-citationDetection of pseudodiffusion in rat brain following blood substitution with perfluorocarbon
Neil, J. J., & Ackerman, J. J. H. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90249-7 · Cited by 44
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationBiophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Self-citationPros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
What can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Self-citation
Metadata
- Authors
- Duong, T. Q., Yacoub, E., Adriany, G., Hu, X., Uǧurbil, K., & Kim, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-05-16
- Volume
- 49
- Issue
- 6
- Pages
- 1019-1027
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2108049514
- Cited by
- 360
- References
- 36
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.