Visualization of neural tissue water compartments using biexponential diffusion tensor MRI
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The apparent diffusion tensor (ADT) imaging method was extended to account for multiple diffusion components. A biexponential ADT imaging experiment was used to obtain separate images of rapidly and slowly diffusing water fractions in excised rat spinal cord. The fast and slow component tensors were compared and found to exhibit similar gross features, such as fractional anisotropy, in both white and gray matter. However, there were also some important differences, which are consistent with the different structures occupying intracellular and extracellular spaces. Evidence supporting the assignment of the two tensor components to extracellular and intracellular water fractions is provided by an NMR spectroscopic investigation of homogeneous samples of brain tissue. Magn Reson Med 45:580–587, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 3×
“[1] may be expanded to a linear combination of observable signal components (15):”
BackgroundMethodInfluentialBasser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Extracellular space structure revealed by diffusion analysis
Nicholson, C., & Syková, E. (1998) · Trends in Neurosciences · doi:10.1016/s0166-2236(98)01261-2 · Cited by 914
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
“9 shows the same but for the two-fiber data modeled by a dual tensor (Inglis et al., 2001; Tuch et al., 2002) and CHARMED framework with one hindered and two restricted compartments.”
BackgroundWhite matter characterization with diffusional kurtosis imaging
Fieremans, E., Jensen, J. H., & Helpern, J. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.006 · Cited by 561
Comprehensive approach for correction of motion and distortion in diffusion‐weighted MRI
Rohde, G. K., Barnett, A. S., Basser, P. J., Marenco, S., & Pierpaoli, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10677 · Cited by 533
Magin, R. L., Abdullah, O., Baleanu, D., & Zhou, X. J. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.11.007 · Cited by 436
Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)
Özarslan, E., Shepherd, T. M., Vemuri, B. C., Blackband, S. J., & Mareci, T. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.024 · Cited by 388
Self-citationSchmithorst, V. J., Wilke, M., Dardzinski, B. J., & Holland, S. K. (2005) · Human Brain Mapping · doi:10.1002/hbm.20149 · Cited by 382
Cohen, Y., & Assaf, Y. (2002) · NMR in Biomedicine · doi:10.1002/nbm.778 · Cited by 270
Statistical model for diffusion attenuated MR signal
Yablonskiy, D. A., Bretthorst, G. L., & Ackerman, J. J. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10578 · Cited by 233
“[14]”
MR microscopy and high resolution small animal MRI: applications in neuroscience research
Benveniste, H., & Blackband, S. (2002) · Progress in Neurobiology · doi:10.1016/s0301-0082(02)00020-5 · Cited by 209
Wu, Y.-C., & Alexander, A. L. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.050 · Cited by 191
“The problems with the simple diffusion tensor model arise from two sources—(1) apparent “fast” and “slow” diffusing components (Niendorf et al., 1996; Mulkern et al., 1999; Assaf and Cohen, 1998a, 2000; Clark and Le Bihan, 2000; Inglis et al., 2001; Ronen et al., 2003; Maier et al., 2004) that cause the signal decay w…”
BackgroundZhang, J., Jones, M., DeBoy, C. A., Reich, D. S., Farrell, J. A. D., Hoffman, P. N., Griffin, J. W., Sheikh, K. A., Miller, M. I., Mori, S., et al. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.3941-08.2009 · Cited by 188
Zhou, X. J., Gao, Q., Abdullah, O., & Magin, R. L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22285 · Cited by 187
“The biexponential model yields a slow diffusion fraction of only 40% (4).”
BackgroundTheoretical models of the diffusion weighted MR signal
Yablonskiy, D. A., & Sukstanskii, A. L. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1520 · Cited by 173
“[46], the average propagator PðX; DÞ can be readily calculated:”
BackgroundThe sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
The tensor distribution function
Leow, A. D., Zhu, S., Zhan, L., McMahon, K., de Zubicaray, G. I., Meredith, M., Wright, M. J., Toga, A. W., & Thompson, P. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21852 · Cited by 101
An Introduction to Computational Diffusion MRI: the Diffusion Tensor and Beyond
Alexander, D. C. (2006) · Mathematics and Visualization · doi:10.1007/3-540-31272-2_5 · Cited by 70
“We focus here on reconstructing fibre orientations, but note that some diffusion MRI techniques aim to estimate other features of the microstructure, such as the ratio of intracellular to extracellular water [13], by targeting other features of p.”
BackgroundMRI of whole rat brain perivascular network reveals role for ventricles in brain waste clearance
Magdoom, K. N., Brown, A., Rey, J., Mareci, T. H., King, M. A., & Sarntinoranont, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-44938-1 · Cited by 35
Self-citationKershaw, J., Tomiyasu, M., Kashikura, K., Hirano, Y., Nonaka, H., Hirano, M., Ikehira, H., Kanno, I., & Obata, T. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1391 · Cited by 14
“have investigated signal decay in the resting state with a biexponential tensor formalism, finding that anisotropy of the tissue is not the cause of non-exponential behaviour (17).”
Background
Metadata
- Authors
- Inglis, B. A., Bossart, E. L., Buckley, D. L., Wirth, E. D., & Mareci, T. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-03-27
- Volume
- 45
- Issue
- 4
- Pages
- 580-587
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2103963974
- Cited by
- 131
- References
- 6
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.