The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Contrast agents and cerebral hemodynamics
Abstract
Contrast‐enhanced magnetic resonance imaging of regional cerebral hemodynamics is discussed. Techniques for measuring cerebral blood volume (CBV) have been validated in animal models and have recently been applied to human studies. Factors affecting CBV measurement in pathologic tissue are addressed. Extension of these techniques to the measurement of cerebral blood flow is presented. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
On the Regulation of the Blood‐supply of the Brain
Roy, C. S., & Sherrington, C. S. (1890) · The Journal of Physiology · doi:10.1113/jphysiol.1890.sp000321 · Cited by 1,822
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Self-citationEquations for Measuring Blood Flow by External Monitoring of Radioisotopes
ZIERLER, K. L. (1965) · Circulation Research · doi:10.1161/01.res.16.4.309 · Cited by 786
Villringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706
Self-citationCerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.
Axel, L. (1980) · Radiology · doi:10.1148/radiology.137.3.7003648 · Cited by 625
Functional cerebral imaging by susceptibility‐contrast NMR
Belliveau, J. W., Rosen, B. R., Kantor, H. L., Rzedzian, R. R., Kennedy, D. N., McKinstry, R. C., Vevea, J. M., Cohen, M. S., Pykett, I. L., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140311 · Cited by 570
Self-citationTracer kinetic methods in medical physiology
Lassen, N. A., & Perl, W. (1979) · Raven Press eBooks · Cited by 495
Di Chiro, G., Oldfield, E., Wright, D., De Michele, D., Katz, D., Patronas, N., Doppman, J., Larson, S., Ito, M., & Kufta, C. (1988) · American Journal of Roentgenology · doi:10.2214/ajr.150.1.189 · Cited by 422
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Self-citation
Cited by
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Self-citationDiffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Wu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Self-citationMagnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Law, M., Young, R. J., Babb, J. S., Peccerelli, N., Chheang, S., Gruber, M. L., Miller, D. C., Golfinos, J. G., Zagzag, D., & Johnson, G. (2008) · Radiology · doi:10.1148/radiol.2472070898 · Cited by 534
Dynamic contrast‐enhanced MRI in clinical oncology: Current status and future directions
Padhani, A. R. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10176 · Cited by 472
Sorensen, A. G., Copen, W. A., Østergaard, L., Buonanno, F. S., Gonzalez, R. G., Rordorf, G., Rosen, B. R., Schwamm, L. H., Weisskoff, R. M., & Koroshetz, W. J. (1999) · Radiology · doi:10.1148/radiology.210.2.r99fe06519 · Cited by 404
Self-citationPerfusion‐weighted imaging defects during spontaneous migrainous aura
Cutrer, F. M., Sorensen, A. G., Weisskoff, R. M., Østergaard, L., Del Rio, M. S., Lee, E. J., Rosen, B. R., & Moskowitz, M. A. (1998) · Annals of Neurology · doi:10.1002/ana.410430108 · Cited by 372
Self-citationPitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290420 · Cited by 335
Self-citationSusceptibility contrast imaging of cerebral blood volume: Human experience
Rosen, B. R., Belliveau, J. W., Aronen, H. J., Kennedy, D., Buchbinder, B. R., Fischman, A., Gruber, M., Glas, J., Weisskoff, R. M., Cohen, M. S., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220227 · Cited by 300
Self-citationPrinciples of cerebral perfusion imaging by bolus tracking
Østergaard, L. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20460 · Cited by 289
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Ellingson, B. M. (2015) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-014-0506-0 · Cited by 132
Microbubbles as a novel contrast agent for brain MRI
Cheung, J. S., Chow, A. M., Guo, H., & Wu, E. X. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.037 · Cited by 36
Metadata
- Authors
- Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L. M., Kennedy, D. N., Neuder, M. S., Fisel, C. R., Aronen, H. J., Kwong, K. K., Weisskoff, R. M., Cohen, M. S., & Brady, T. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-06
- Volume
- 19
- Issue
- 2
- Pages
- 285-292
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2093449268
- Cited by
- 290
- References
- 32
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.