The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Open accessAbstract
New diffusion‐weighted imaging (DWI) methods, including high‐b, q‐space, and high angular resolution MRI methods, attempt to extract information about non‐Gaussian diffusion in tissue that is not provided by low‐b‐value (b ≈ 1000 s mm−2) diffusion or diffusion tensor magnetic resonance imaging (DT‐MRI). Additionally, DWI data with higher spatial resolution are being acquired to resolve fine anatomic structures, such as white matter fasciculi. Increasing diffusion‐weighting or decreasing voxel size can reduce the signal‐to‐noise ratio so that some DWI signals are close to the background noise level. Here we report several new artifacts that can be explained by considering how background noise affects the peanut‐shaped angular apparent diffusion coefficient (ADC) profile. These include an orientationally dependent deviation from Gaussian behavior of the ADC profile, an underestimation of indices of diffusion anisotropy, and a correlation between estimates of mean diffusivity and diffusion anisotropy. We also discuss how noise can cause increased gray/white matter DWI contrast at higher b values and an apparent elevation of diffusion anisotropy in acute ischemia. Importantly, all of these artifacts are negligible in the b‐value range typically used in DT‐MRI of brain (b ≈ 1000 s mm−2). Finally, we demonstrate a strategy for ameliorating the rectified noise artifact in data collected at higher b values. Magn Reson Med 52:979–993, 2004. Published 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Self-citationEstimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Self-citationDiffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Self-citationThe rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Self-citationMoseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Self-citationAnalysis of partial volume effects in diffusion‐tensor MRI
Alexander, A. L., Hasan, K. M., Lazar, M., Tsuruda, J. S., & Parker, D. L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1105 · Cited by 695
Cited by
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationDenoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Self-citationSmith, R. E., Tournier, J.-D., Calamante, F., & Connelly, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.005 · Cited by 1,216
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827
Self-citationArtifacts and pitfalls in diffusion MRI
Le Bihan, D., Poupon, C., Amadon, A., & Lethimonnier, F. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20683 · Cited by 778
Diffusion MRI noise mapping using random matrix theory
Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26059 · Cited by 773
Andersson, J. L. R., Graham, M. S., Zsoldos, E., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.058 · Cited by 763
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Veraart, J., Sijbers, J., Sunaert, S., Leemans, A., & Jeurissen, B. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.028 · Cited by 504
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Baum, G. L., Ciric, R., Roalf, D. R., Betzel, R. F., Moore, T. M., Shinohara, R. T., Kahn, A. E., Vandekar, S. N., Rupert, P. E., Quarmley, M., et al. (2017) · Current Biology · doi:10.1016/j.cub.2017.04.051 · Cited by 401
Jbabdi, S., Sotiropoulos, S. N., Savio, A. M., Graña, M., & Behrens, T. E. J. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24204 · Cited by 399
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Diffusion Weighted Image Denoising Using Overcomplete Local PCA
Manjón, J. V., Coupé, P., Concha, L., Buades, A., Collins, D. L., & Robles, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073021 · Cited by 417
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
Lebel, C., Treit, S., & Beaulieu, C. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3778 · Cited by 379
Jones, D. K., & Leemans, A. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61737-992-5_6 · Cited by 379
Self-citationFarrell, J. A. D., Landman, B. A., Jones, C. K., Smith, S. A., Prince, J. L., van Zijl, P. C. M., & Mori, S. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21053 · Cited by 357
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
Complex diffusion-weighted image estimation via matrix recovery under general noise models
Cordero-Grande, L., Christiaens, D., Hutter, J., Price, A. N., & Hajnal, J. V. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.039 · Cited by 354
MR diffusion kurtosis imaging for neural tissue characterization
Wu, E. X., & Cheung, M. M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1506 · Cited by 346
Partial volume effect as a hidden covariate in DTI analyses
Vos, S. B., Jones, D. K., Viergever, M. A., & Leemans, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.048 · Cited by 345
Self-citationDiffusion-Tensor MR Imaging and Tractography: Exploring Brain Microstructure and Connectivity
Nucifora, P. G. P., Verma, R., Lee, S.-K., & Melhem, E. R. (2007) · Radiology · doi:10.1148/radiol.2452060445 · Cited by 344
Reduced Prefrontal Connectivity in Psychopathy
Motzkin, J. C., Newman, J. P., Kiehl, K. A., & Koenigs, M. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.4215-11.2011 · Cited by 342
The Human Connectome Project: A retrospective
Elam, J. S., Glasser, M. F., Harms, M. P., Sotiropoulos, S. N., Andersson, J. L. R., Burgess, G. C., Curtiss, S. W., Oostenveld, R., Larson-Prior, L. J., Schoffelen, J.-M., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118543 · Cited by 307
Forkel, S. J., Thiebaut de Schotten, M., Dell’Acqua, F., Kalra, L., Murphy, D. G. M., Williams, S. C. R., & Catani, M. (2014) · Brain · doi:10.1093/brain/awu113 · Cited by 306
Dell'Acqua, F., Scifo, P., Rizzo, G., Catani, M., Simmons, A., Scotti, G., & Fazio, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.033 · Cited by 304
Word learning is mediated by the left arcuate fasciculus
López-Barroso, D., Catani, M., Ripollés, P., Dell'Acqua, F., Rodríguez-Fornells, A., & de Diego-Balaguer, R. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301696110 · Cited by 290
Landman, B. A., Farrell, J. A. D., Jones, C. K., Smith, S. A., Prince, J. L., & Mori, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.056 · Cited by 285
Forkel, S. J., Thiebaut de Schotten, M., Kawadler, J. M., Dell'Acqua, F., Danek, A., & Catani, M. (2014) · Cortex · doi:10.1016/j.cortex.2012.09.005 · Cited by 248
DWI of the spinal cord with reduced FOV single‐shot EPI
Saritas, E. U., Cunningham, C. H., Lee, J. H., Han, E. T., & Nishimura, D. G. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21640 · Cited by 264
Langen, M., Leemans, A., Johnston, P., Ecker, C., Daly, E., Murphy, C. M., dell’Acqua, F., Durston, S., & Murphy, D. G. M. (2012) · Cortex · doi:10.1016/j.cortex.2011.05.018 · Cited by 234
Roalf, D. R., Quarmley, M., Elliott, M. A., Satterthwaite, T. D., Vandekar, S. N., Ruparel, K., Gennatas, E. D., Calkins, M. E., Moore, T. M., Hopson, R., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.068 · Cited by 199
Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain
Grech‐Sollars, M., Hales, P. W., Miyazaki, K., Raschke, F., Rodriguez, D., Wilson, M., Gill, S. K., Banks, T., Saunders, D. E., Clayden, J. D., et al. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3269 · Cited by 213
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Self-citationThe impact of in-scanner head motion on structural connectivity derived from diffusion MRI
Baum, G. L., Roalf, D. R., Cook, P. A., Ciric, R., Rosen, A. F. G., Xia, C., Elliott, M. A., Ruparel, K., Verma, R., Tunç, B., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.02.041 · Cited by 116
Diffusion-MRI in neurodegenerative disorders
Goveas, J., O’Dwyer, L., Mascalchi, M., Cosottini, M., Diciotti, S., De Santis, S., Passamonti, L., Tessa, C., Toschi, N., & Giannelli, M. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.04.006 · Cited by 104
Structural network analysis of brain development in young preterm neonates
Brown, C. J., Miller, S. P., Booth, B. G., Andrews, S., Chau, V., Poskitt, K. J., & Hamarneh, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.030 · Cited by 103
Schilling, K. G., Archer, D., Yeh, F.-C., Rheault, F., Cai, L. Y., Hansen, C., Yang, Q., Ramdass, K., Shafer, A. T., Resnick, S. M., et al. (2022) · Brain Structure and Function · doi:10.1007/s00429-022-02503-z · Cited by 78
Hutchinson, E. B., Avram, A. V., Irfanoglu, M. O., Koay, C. G., Barnett, A. S., Komlosh, M. E., Özarslan, E., Schwerin, S. C., Juliano, S. L., & Pierpaoli, C. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26575 · Cited by 73
Chung, A. W., Seunarine, K. K., & Clark, C. A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23328 · Cited by 63
Automated tractography of the cingulate bundle in Alzheimer's disease: a multicenter DTI study
Fischer, F. U., Scheurich, A., Wegrzyn, M., Schermuly, I., Bokde, A. L. W., Klöppel, S., Pouwels, P. J. W., Teipel, S., Yakushev, I., & Fellgiebel, A. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23621 · Cited by 34
Applying microstructural models to understand the role of white matter in cognitive development
Huber, E., Henriques, R. N., Owen, J. P., Rokem, A., & Yeatman, J. D. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100624 · Cited by 34
Richardson, S., Siow, B., Panagiotaki, E., Schneider, T., Lythgoe, M. F., & Alexander, D. C. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25012 · Cited by 27
Crombé, A., Nicolas, R., Richard, N., Tourdias, T., & Hiba, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-15511-0 · Cited by 13
Metadata
- Authors
- Jones, D. K., & Basser, P. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-10-26
- Volume
- 52
- Issue
- 5
- Pages
- 979-993
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2149337534
- Cited by
- 587
- References
- 33
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.