The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI
Open accessAbstract
Noninvasive measurement of cerebral venous oxygenation can serve as a tool for better understanding fMRI signals and for clinical evaluation of brain oxygen homeostasis. In this study a novel technique, T2‐Relaxation‐Under‐Spin‐Tagging (TRUST) MRI, is developed to estimate oxygenation in venous vessels. This method uses the spin labeling principle to automatically isolate pure blood signals from which T2 relaxation times are determined using flow‐insensitive T2‐preparation pulses. The blood T2 is then converted to blood oxygenation using a calibration plot. In vivo experiments gave a baseline venous oxygenation of 64.8 ± 6.3% in sagittal sinus in healthy volunteers (n = 24). Reproducibility studies demonstrated that the standard deviation across trials was 2.0 ± 1.1%. The effects of repetition time and inversion time selections were investigated. The TRUST technique was further tested using various physiologic challenges. Hypercapnia induced an increase in venous oxygenation by 13.8 ± 1.1%. On the other hand, caffeine ingestion resulted in a decrease in oxygenation by 7.0 ± 1.8%. Contrast agent infusion (Gd‐DTPA, 0.1 mmol/kg) reduced venous blood T2 by 11.2 ms. The results of this study show that TRUST MRI is a useful technique for quantitative assessment of blood oxygenation in the brain. Magn Reson Med 60:357–363, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827 · cited 1×
“In particular, in combination with a CBF measurements such as phase-contrast MRI or ASL, one can estimate the whole brain cerebral metabolic rate of oxygen (CMRO2) by the Fick principle (1): CMRO2 CBF Ya Yv Ca, in which Ya is the arterial oxygenation and can be obtained noninvasively with pulse oximetry, and Ca is the…”
BackgroundNonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Self-citationWong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9403 · Cited by 563
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Circulation · doi:10.1161/01.cir.99.24.3139 · Cited by 425
He, X., & Yablonskiy, D. A. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21108 · Cited by 396
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Self-citationSafety of magnetic resonance imaging contrast agents
Shellock, F. G., & Kanal, E. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<477::aid-jmri33>3.0.co;2-e · Cited by 321
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Coles, J. P., Minhas, P. S., Fryer, T. D., Smielewski, P., Aigbirihio, F., Donovan, T., Downey, S. P. M. J., Williams, G., Chatfield, D., Matthews, J. C., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200209000-00002 · Cited by 296
Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3T
Zhao, J. M., Clingman, C. S., Närväinen, M. J., Kauppinen, R. A., & van Zijl, P. C. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21342 · Cited by 247
Haacke, E. M., Lai, S., Reichenbach, J. R., Kuppusamy, K., Hoogenraad, F. G. C., Takeichi, H., & Lin, W. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:5<341::aid-hbm2>3.0.co;2-3 · Cited by 224
Comparison of the dependence of blood R2 and R on oxygen saturation at 1.5 and 4.7 Tesla
Silvennoinen, M. J., Clingman, C. S., Golay, X., Kauppinen, R. A., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10355 · Cited by 219
On the Use of Caffeine as a Contrast Booster for BOLD fMRI Studies
Mulderink, T. A., Gitelman, D. R., Mesulam, M.-M., & Parrish, T. B. (2002) · NeuroImage · doi:10.1006/nimg.2001.0973 · Cited by 164 · cited 2×
“TRUST MRI was performed in three healthy subjects before and after 200-mg caffeine tablet intake (26).”
BackgroundMethodMR susceptometry for measuring global brain oxygen extraction
Fernández‐Seara, M. A., Techawiboonwong, A., Detre, J. A., & Wehrli, F. W. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20892 · Cited by 147
Nagdyman, N., Fleck, T., Schubert, S., Ewert, P., Peters, B., Lange, P., & Abdul‐Khaliq, H. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2618-0 · Cited by 144
Magnetic resonance imaging of stationary blood: A review
Brooks, R. A., & Chiro, G. D. (1987) · Medical Physics · doi:10.1118/1.595994 · Cited by 138
An, H., & Lin, W. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10576 · Cited by 138
Magnetic relaxation in blood and blood clots
Bryant, R. G., Marill, K. A., Blackmore, C. C., & Francis, C. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130112 · Cited by 136
Caffeine alters the temporal dynamics of the visual BOLD response
Liu, T. T., Behzadi, Y., Restom, K., Uludaǧ, K., Lu, K., Buračas, G. T., Dubowitz, D. J., & Buxton, R. B. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.061 · Cited by 121
Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI.
Barth, M., & Moser, E. (1997) · PubMed · Cited by 118
Golay, X., Silvennoinen, M. J., Zhou, J., Clingman, C. S., Kauppinen, R. A., Pekar, J. J., & van Zijl, P. C. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1189 · Cited by 118
Lu, H., & van Zijl, P. C. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20379 · Cited by 116
Self-citationDetermination of Oxygen Extraction Ratios by Magnetic Resonance Imaging
Oja, J. M. E., GILLEN, J. S., Kauppinen, R. A., Kraut, M. A., & van Zijl, P. C. M. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199912000-00001 · Cited by 108
Relaxometry of magnetic resonance imaging contrast agents.
Koenig, S. H., & Rd, B. (1987) · PubMed · Cited by 16
IBRAHIM, M. A., Emerson, J. F., & Cotman, C. W. (1998) · Investigative Radiology · doi:10.1097/00004424-199803000-00005 · Cited by 14
Cited by
Alterations in Cerebral Metabolic Rate and Blood Supply across the Adult Lifespan
Lu, H., Xu, F., Rodrigue, K. M., Kennedy, K. M., Cheng, Y., Flicker, B., Hebrank, A. C., Uh, J., & Park, D. C. (2011) · Cerebral Cortex · doi:10.1093/cercor/bhq224 · Cited by 399
Self-citationThe physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
The influence of carbon dioxide on brain activity and metabolism in conscious humans
Xu, F., Uh, J., Brier, M. R., Hart, J., Yezhuvath, U. S., Gu, H., Yang, Y., & Lu, H. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.153 · Cited by 304
Self-citationMRI Estimation of Global Brain Oxygen Consumption Rate
Jain, V., Langham, M. C., & Wehrli, F. W. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.49 · Cited by 275
Non-invasive imaging of oxygen extraction fraction in adults with sickle cell anaemia
Jordan, L. C., Gindville, M. C., Scott, A. O., Juttukonda, M. R., Strother, M. K., Kassim, A. A., Chen, S.-C., Lu, H., Pruthi, S., Shyr, Y., et al. (2016) · Brain · doi:10.1093/brain/awv397 · Cited by 104
Self-citation
Metadata
- Authors
- Lu, H., & Ge, Y.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 60
- Issue
- 2
- Pages
- 357-363
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2114276034
- Cited by
- 360
- References
- 34
- FWCI
- 8.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.