The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Spin‐echo and gradient‐echo epi of human brain activation using bold contrast: A comparative study at 1.5 T
Abstract
In this study, Blood Oxygenation Level Dependent (BOLD) contrast in the detection of human brain activation was compared between spin‐echo and gradient‐echo echo‐planar sequences at 1.5 T. Time course series of spin‐echo and gradient‐echo images containing the primary motor cortex were collected during rest (no finger movement) and activation (finger movement). Each time course series was collected using a different TE. Resting and active state signal intensities at each TE were measured in identical regions in the motor cortex. From these data, resting and active state R2 (1/T2) and R (1/T) values were obtained. Across four subjects, brain activation produced an average R2 change of −0.16±0.02/s (±SE), and an average R change of −0.55±0.08/s. The average Δ R/Δ R2 ratio was 3.52±0.56. The average gradient‐echo/spin‐echo ratio of activation‐induced signal changes at the TE for maximal BOLD contrast for each sequence (TE≈T and T2) was calculated to be 1.87±0.40.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Self-citationOgawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Self-citationBrain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
The Magnetic Properties and Structure of Hemoglobin, Oxyhemoglobin and Carbonmonoxyhemoglobin
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.4.210 · Cited by 1,159
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Villringer, A., Planck, J., Hock, C., Schleinkofer, L., & Dirnagl, U. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90181-j · Cited by 1,119
Frostig, R. D., Lieke, E. E., Ts'o, D. Y., & Grinvald, A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.16.6082 · Cited by 959
Ogawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Echo‐planar time course MRI of cat brain oxygenation changes
Turner, R., Bihan, D. L., Moonen, C. T. W., Despres, D., & Frank, J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220117 · Cited by 421
Menon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300317 · Cited by 413
Dynamic MR imaging of human brain oxygenation during rest and photic stimulation
Frahm, J., Bruhn, H., Merboldt, K., & Hänicke, W. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020505 · Cited by 385
Weisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Dynamic mapping of the human visual cortex by high-speed magnetic resonance imaging.
Blamire, A. M., Ogawa, S., Ugurbil, K., Rothman, D., McCarthy, G., Ellermann, J. M., Hyder, F., Rattner, Z., & Shulman, R. G. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.22.11069 · Cited by 367
Functional MRI of human brain activation at high spatial resolution
Frahm, J., Merboldt, K., & Hänicke, W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290126 · Cited by 350
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
NMR relaxation times of blood: dependence on field strength, oxidation state, and cell integrity.
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · PubMed · Cited by 213
NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198707000-00025 · Cited by 195
Application of spin-echo nuclear magnetic resonance to whole-cell systems. Membrane transport
Brindle, K. M., Brown, F. F., Campbell, I. D., Grathwohl, C., & Kuchel, P. W. (1979) · Biochemical Journal · doi:10.1042/bj1800037 · Cited by 170
Magnetic resonance imaging of stationary blood: A review
Brooks, R. A., & Chiro, G. D. (1987) · Medical Physics · doi:10.1118/1.595994 · Cited by 138
Echo‐planar MR imaging of human brain oxygenation changes
Stehling, M. K., Schmitt, F., & Ladebeck, R. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030307 · Cited by 59
T2 effect of hemoglobin concentration: assessment with in vitro MR spectroscopy.
Hayman, L. A., Ford, J. J., Taber, K. H., Saleem, A., Round, M. E., & Bryan, R. N. (1988) · Radiology · doi:10.1148/radiology.168.2.3393669 · Cited by 47
Cited by
Ojemann, J. G., Akbudak, E., Snyder, A. Z., McKinstry, R. C., Raichle, M. E., & Conturo, T. E. (1997) · NeuroImage · doi:10.1006/nimg.1997.0289 · Cited by 694
Image Distortion Correction in fMRI: A Quantitative Evaluation
Hutton, C., Bork, A., Josephs, O., Deichmann, R., Ashburner, J., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.1054 · Cited by 681
Swain, R. A., Harris, A. B., Wiener, E. C., Dutka, M. V., Morris, H. D., Theien, B. E., Konda, S., Engberg, K., Lauterbur, P. C., & Greenough, W. T. (2003) · Neuroscience · doi:10.1016/s0306-4522(02)00664-4 · Cited by 655
Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
Kundu, P., Inati, S. J., Evans, J. W., Luh, W.-M., & Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.028 · Cited by 615
Self-citationHow reliable are the results from functional magnetic resonance imaging?
Bennett, C. M., & Miller, M. B. (2010) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2010.05446.x · Cited by 577
Metadata
- Authors
- Bandettini, P. A., Wong, E. C., Jesmanowicz, A., Hinks, R. S., & Hyde, J. S.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 1994-03
- Volume
- 7
- Issue
- 1-2
- Pages
- 12-20
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2079842952
- Cited by
- 349
- References
- 29
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.