Histologic and physiologic evaluation of electrically stimulated peripheral nerve: Considerations for the selection of parameters
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Helical electrodes were implanted around the left and right common peroneal nerves of cats. Three weeks after implantation one nerve was stimulated for 4-16 hours using charge-balanced, biphasic, constant current pulses. Compound action potentials (CAP) evoked by the stimulus were recorded from over the cauda equina before, during and after the stimulation. Light and electron microscopy evaluations were conducted at various times following the stimulation. The mere presence of the electrode invariably resulted in thickened epineurium and in some cases increased peripheral endoneurial connective tissue beneath the electrodes. Physiologic changes during stimulation included elevation of the electrical threshold of the large axons in the nerve. This was reversed within one week after stimulation at a frequency of 20 Hz, but often was not reversed following stimulation at 50-100 Hz. Continuous stimulation at 50 Hz for 8-16 hours at 400 microA or more resulted in neural damage characterized by endoneurial edema beginning within 48 hours after stimulation, and early axonal degeneration (EAD) of the large myelinated fibers, beginning by 1 week after stimulation. Neural damage due to electrical stimulation was decreased or abolished by reduction of the duration of stimulation, by stimulating at 20 Hz (vs. 50 Hz) or by use of an intermittent duty cycle. These results demonstrate that axons in peripheral nerves can be irreversely damaged by 8-16 hours of continuous stimulation at 50 Hz…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, its open structural shape explains the low selectivity of the electrode (Agnew et al., 1989) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Agnew et al., 1989
In the citing paper
“Initial issues with implantable extraneural electrodes often result from mechanical constriction and injury to the nerve during the surgical implantation process [43, 44].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
In the citing paper
“The safety of acute and chronic peripheral nerve stimulation has been demonstrated in animals and humans for pulse durations from 1 to 300 μs for the purpose of motor function and sensory feedback [43, 44, 75]”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
In the citing paper
“As discussed previously, the length of stimulation application has been shown to influence the degree of induced neural damage.”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
In the citing paper
“Their results showed no neural damage after continuous stimulation at 20 Hz for 16 h. However, with otherwise identical parameters, a frequency of 50 Hz resulted in neural damage.”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
(1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-101-4-579_1 · Cited by 525
Pathoanatomy and Pathophysiology of Nerve Root Compression
RYDEVIK, B., BROWN, M. D., & LUNDBORG, G. (1984) · Spine · doi:10.1097/00007632-198401000-00004 · Cited by 503
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 359
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · cited 1×
“The presence of a delay between the first and second phases of the pulse pair allows more efficient excitation of smaller axons (16); with an interval less than 300 #s, the amplitude of the later components of the CAP (representing smaller, more slowly conducting myelinated axons) was attenuated.”
BackgroundSacral anterior root stimulators for bladder control in paraplegia
Brindley, G. S., Polkey, C. E., & Rushton, D. N. (1982) · Spinal Cord · doi:10.1038/sc.1982.65 · Cited by 311 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundChronic Nerve Compression—an Experimental Model in the Rat
Mackinnon, S. E., Dellon, A. L., Hudson, A. R., & Hunter, D. A. (1984) · Annals of Plastic Surgery · doi:10.1097/00000637-198408000-00004 · Cited by 307 · cited 1×
“This type of neural damage closely resembles that previously described for chronic peripheral nerve compression ( 23 ).”
BackgroundBoyd, I. A., & Kalu, K. U. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012737 · Cited by 197 · cited 2×
“The alpha component is generated mainly by large myelinated axons which, in the cat sciatic nerve, have conduction velocities centered around 70-90 m/sec, and have outside diameters of 10/~m or more (6).”
BackgroundResultLong-term pain control by direct peripheral-nerve stimulation.
Nashold, B. S., Goldner, J. L., Mullen, J. B., & Bright, D. S. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00001 · Cited by 184 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundA DESCRIPTIVE STUDY OF THE BLOOD VESSELS OF THE SCIATIC NERVE IN THE RAT, MAN AND OTHER MAMMALS
BELL, M. A. (1984) · Brain · doi:10.1093/brain/107.3.871 · Cited by 163 · cited 1×
“This is in keeping with the well known adaptability provided by the intraneural microvascular system (1,4,30).”
BackgroundWaters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
Background
Research works printed but not linked: 1
- Jacobs, J.; LeQuesne, P.M. Toxic disorders of the nervous system. In: Adams, J.H.; Corsellis, J.A.N.; Duchen, L.W., eds. Greenfield Neuropathology. New York: John Wiley & Sons, 4th Ed.; 1984: pp. 627–698.
Cited by
Items 101–187 of 187
Nishizaki, A., Sakamoto, K., Saku, K., Hosokawa, K., Sakamoto, T., Oga, Y., Akashi, T., Murayama, Y., Kishi, T., Ide, T., et al. (2016) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2016.04.021 · Cited by 17
“Several modes of injury, such as compressive,(17) reperfusion,(18,19) and electrical damage to peripheral nerves secondary to implantation and electrical activation of electrodes have been reported.(20,21) In the present study, physical damage caused by compression and electrode attachment to the vagal nerve were conc…”
BackgroundIntracortical Microstimulation Parameters Dictate the Amplitude and Latency of Evoked Responses
Watson, M., Dancause, N., & Sawan, M. (2015) · Brain stimulation · doi:10.1016/j.brs.2015.10.008 · Cited by 20
“Some of these parameters are known to induce tissue damage within specific ranges [40,50–52], and most applications have restrictive requirements of the stimulus.”
Wang, H., Guo, W., Yang, K., Wei, F., Dubner, R. A., & Ren, K. (2010) · The Open Pain Journal · doi:10.2174/1876386301003010144 · Cited by 17
Electroencephalography, electrocorticography, and cortical stimulation techniques
Simon, M. V., Nuwer, M. R., & Szelényi, A. (2022) · Handbook of clinical neurology · doi:10.1016/b978-0-12-819826-1.00001-6 · Cited by 15
Histopathology of the stimulated Vagus nerve: primum non nocere
Cohen, M. L., & Georgievskaya, Z. (2010) · Heart Failure Reviews · doi:10.1007/s10741-010-9182-6 · Cited by 14
“Although damage to peripheral nerve caused by electrical stimulation was elucidated in seminal publications by Agnew and McCreery two decades ago [25, 26], mechanisms of sublethal electrical tissue injury have only recently been subject to intense study, primarily due to the utility of electroporation for gene transfe…”
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02223-1 · Cited by 14
Self-citationA Nerve Cuff Electrode for Controlled Reshaping of Nerve Geometry
Caparso, A., Durand, D. M., & Mansour, J. M. (2008) · Journal of Biomaterials Applications · doi:10.1177/0885328208097426 · Cited by 15
“Extraneural electrodes [4,5], such as the spiral [6,7] and the helix [8], have cylindrical cross-sections and have applications in functional electric stimulation (FES) devices [5,9].”
BackgroundElectrodes for the Neural Interface
Tyler, D. J., & Polasek, K. H. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00018-5 · Cited by 17
Seif, C., Braun, P. M., Bross, S., Scheepe, J. R., Weiß, J., Schumacher, S., Zendler, S., Alken, P. M., & Junemann, K. P. (2002) · Neurourology and Urodynamics · doi:10.1002/nau.10037 · Cited by 13
Branen, A., Yao, Y., Kothare, M. V., Mahmoudi, B., & Kumar, G. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.798157 · Cited by 12
“, delivering VNS at the maximum allowable pulse width and frequency) may damage tissues over a longer period of VNS application (Agnew et al., 1989).”
BackgroundRay, A., Lee, E.-J., Humayun, M. S., & Weiland, J. D. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045003 · Cited by 15
Lao, J., Li, Y., Zhao, X., Tian, D., Zhu, Y., & Wei, X. (2014) · Neural Regeneration Research · doi:10.4103/1673-5374.125346 · Cited by 12
“The compound nerve action potential has been recorded in many different species, including cats([26-27]), rats([5]), guinea pig([28-29]), monkeys([30]) and humans([23]).”
BackgroundMian, S. Y., Honey, J. R., Carnicer‐Lombarte, A., & Barone, D. G. (2021) · Biosensors · doi:10.3390/bios11080275 · Cited by 11
“Myelin thinning, one of the unexpected sequelae reported, is detrimental to nerve functioning [55,60] and future efforts to tackle it may be key to also reducing the FBR in electrodes implanted in the PNS.”
BackgroundSun, S., Delgado, J., Behzadian, N., Yeomans, D. C., & Anderson, T. A. (2020) · Current Protocols in Neuroscience · doi:10.1002/cpns.99 · Cited by 10
Electrodes and instrumentation for neurostimulation
Merrill, D. R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00002-2 · Cited by 9
The Electrode – Materials and Configurations
Merrill, D. R. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-381409-8.00006-1 · Cited by 10
Principles of Recording from and Electrical Stimulation of Neural Tissue
Fallon, J. B., & Carter, P. M. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch4 · Cited by 12
Vasudevan, S., Vo, J., Shafer, B., Nam, A. S., Vakoc, B. J., & Hammer, D. X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab1405 · Cited by 11
Sammut, S., Koh, R. G. L., & Zariffa, J. (2021) · Sensors · doi:10.3390/s21020506 · Cited by 9
Neuroprostheses for management of dysphagia resulting from cerebrovascular disorders
Tyler, D. J. (2007) · Springer eBooks · doi:10.1007/978-3-211-33079-1_40 · Cited by 9
“A bipolar helical electrode [ 2 , 3] is placed on the recurrent laryngeal nerve.”
BackgroundVelikay‐Parel, M., Ivastinović, D., Georgi, T., Richard, G. W., & Hornig, R. (2013) · Acta Ophthalmologica · doi:10.1111/aos.12179 · Cited by 9
“This stimulus-induced depression of neuronal excitability (SIDNE) was first defined and published by Douglas McCreery’s group (McCreery et al. 1986; Agnew et al. 1989).”
BackgroundInfrared Nerve Stimulation: A Novel Therapeutic Laser Modality
Wells, J. D., Cayce, J. M., Mahadevan-Jansen, A. M., Konrad, P. E., & Jansen, D. (2010) · Springer eBooks · doi:10.1007/978-90-481-8831-4_24 · Cited by 8
“inert) interface materials (glass/fiber optic cable versus metal) [ 71 ].”
BackgroundHistopathologic and functional effects of facial nerve following electrical stimulation
Sapmaz, E., Kaygusuz, İ., Alpay, H. C., Akpolat, N., Keleş, E., Karlıdağ, T., Orhan, İ., & Yalçın, Ş. (2009) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-009-1107-4 · Cited by 10
“[16] for the Wrst time in 1989 applied electrical stimulation of 1.”
BackgroundA SELF-OPTIMISING PORTABLE FES SYSTEM USING AN ELECTRODE ARRAY AND MOVEMENT SENSORS
Elsaify, A. (2005) · Figshare · Cited by 9
Neurologic Medical Device Overview for Pathologists
Cramer, S. D., Lee, J. S., Butt, M. T., Paulin, J., & Stoffregen, W. C. (2019) · Toxicologic Pathology · doi:10.1177/0192623318816685 · Cited by 7
“Stimulation of peripheral nerves can cause edema and axon degeneration (Agnew et al. 1989) as well as changes in myofiber components (Bijak et al. 2001).”
BackgroundNeurostimML: a machine learning model for predicting neurostimulation-induced tissue damage
Li, Y., Frederick, R. A., George, D., Cogan, S. F., Pancrazio, J. J., Bleris, L. G., & Hernandez-Reynoso, A. G. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad593e · Cited by 7
“The remaining three most important features are directly related to the amount of charge either per unit area (e.g. charge density) or per unit of time (e.g. charge per phase and daily accumulated charge), which has been known and accepted for over 30 years [12, 13, 21, 22, 54–56].”
BackgroundThe Role of Biomaterials in Stimulating Bioelectrodes
Peckham, P. H., Ackermann, D. M., & Moss, C. W. (2012) · Elsevier eBooks · doi:10.1016/b978-0-08-087780-8.00084-x · Cited by 8
Dewberry, L. S., Porche, K. M., Koenig, T., Allen, K. D., & Otto, K. J. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00119-0 · Cited by 6
McCreery, D. B., & Agnew, W. F. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1990.691853 · Cited by 7
Self-citationSahyouni, R., Haidar, Y. M., Moshtaghi, O., Wang, B. Y., Djalilian, H. R., Middlebrooks, J. C., & Lin, H. W. (2017) · Otology & Neurotology · doi:10.1097/mao.0000000000001545 · Cited by 6
Electrodes for the Neural Interface
Tyler, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00020-6 · Cited by 9
Functional Electrical Stimulation
Venkatasubramanian, G., Jung, R., & Sweeney, J. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd119 · Cited by 8
Grill, W. M., & Kirsch, R. F. (1999) · Wiley eBooks · doi:10.1002/047134608x.w1424 · Cited by 8
Monroy, G. L., Erfanzadeh, M., Tao, M., DePaoli, D. T., Saytashev, I., Nam, A. S., Rafi, H., Kwong, K., Shea, K. I., Vakoc, B. J., et al. (2023) · Neurophotonics · doi:10.1117/1.nph.10.2.025004 · Cited by 5
Tyler, D. J., Polasek, K. H., & Schiefer, M. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-802653-3.00112-3 · Cited by 10
Broncel, A., Bocian, R., Kłos‐Wojtczak, P., & Konopacki, J. (2018) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2018.05.005 · Cited by 5
Safety and Efficacy of a Novel Direct Bladder Wall Stimulation Device in Canines
Kotkar, A. U., Sperry, Z. J., Anaya, C. J., Bohannon, A. S., Jackson, N. D., Johnson, C. R., LaFrance, E. M., & Seidl, S. E. (2026) · JU Open Plus · doi:10.1097/ju9.0000000000000469 · Cited by 5
Reliability of Closed Double Helix Electrode for Functional Electrical Stimulation
Kagaya, H., Sharma, M., Polando, G., & Marsolais, E. B. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199801000-00029 · Cited by 4
Ragnarsson, K. T. (1994) · Elsevier eBooks · doi:10.1016/b978-1-4831-7818-9.50029-0 · Cited by 4
Real time imaging of peripheral nerve vasculature using optical coherence angiography
Vasudevan, S., Kumsa, D., Takmakov, P. A., Welle, C. G., & Hammer, D. X. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2213160 · Cited by 4
“The effects of stimulus amplitude and frequency on peripheral nerve injury have been similarly documented [3, 4].”
BackgroundThe electrode—principles of the neural interface and materials
Merrill, D. R., & Stecker, M. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-817000-7.00007-7 · Cited by 3
Schiefer, M. A. (2009) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
The stimulus router system: A novel neural prosthesis
Gan, L. S. (2010) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3c98d · Cited by 3
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad3b6a · Cited by 2
Translating Electric KHFAC and DC Nerve Block from Research to Application
Franke, M. (2014) · OhioLink ETD Center (Ohio Library and Information Network) · doi:10.13140/rg.2.1.4496.1445 · Cited by 2
Ahmed, M., & Huntoon, M. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-40196-8.00074-7 · Cited by 2
VNS Therapy for the Treatment of Epilepsy
Wright, C. W., Bu, L., Jones, A., & Green, N. C. (2017) · Springer eBooks · doi:10.1007/978-3-319-28612-9_8 · Cited by 3
Neural electrodes for long-term tissue interfaces
del Valle, J., Rodríguez‐Meana, B., & Navarro, X. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00009-5 · Cited by 2
Wang, R., Yu, H., & Li, Z. (2017) · Toxinology · doi:10.1007/978-981-10-2798-7_41-1 · Cited by 2
Neural Interfacing with the Peripheral Nervous System: A FINE Approach
Durand, D. M., Wodlinger, B., & Park, H. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5227-0_16 · Cited by 2
Rhee, E. K., Furnary, A. P., ELSON, J. J., & Kao, R. L. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02961.x · Cited by 2
Vagus Nerve Stimulation: Rapid versus Slow Cycling in a Laboratory Model
Fisher, R. S. (2016) · Neurotherapeutics · doi:10.1007/s13311-016-0441-7 · Cited by 2
“[1] on peripheral nerves suggested that tissue was less stressed by intermittent electrical stimulation, although this may not be the case for clinical neurostimulation within safe parameters.”
BackgroundAnalyzing Spinal Cord Stimulation With Different Electrode Configurations: A Numerical Study
Aydın, E. F., & Zengin, R. (2024) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3894 · Cited by 1
Chan, C.-C., Lin, C. K., & Ju, M. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519412005046 · Cited by 1
A Programmable 6 bit DAC of current-steering dedicated to nerve stimulator
Rekik, N., S'Habou, S., Hamida, A. B., & Samet, M. (2008) · International Conference on Design & Technology of Integrated Systems in Nanoscale Era (DTIS) · doi:10.1109/dtis.2008.4540210 · Cited by 1
“The signal amplitude specifies the stimulus intensities [ 3 ].”
BackgroundTransient Optical Nerve Stimulation
Kao, C., Mahadevan-Jansen, A. M., Konrad, P. E., Wells, J. D., & Jansen, D. (2007) · CRC Press eBooks · doi:10.1201/9780849381850.ch21 · Cited by 1
Malpractice in Skull Base Surgery
Sioshansi, P. C., Chen, T., & Babu, S. C. (2021) · Springer eBooks · doi:10.1007/978-3-030-64418-5_10 · Cited by 1
Wheless, J. W., Gienapp, A. J., & Mudigoudar, B. D. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-91702-5.00005-0 · Cited by 1
Neural multichannel electrical stimulation for total bladder evacuation
Sawan, M., HASSOUNA, M. M., Li, J.-S., Duval, F., & ELHILALI, M. M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1993.979124 · Cited by 1
A nerve cuff electrode for controlled reshaping of neural geometry
Caparso, A., & Durand, D. M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1053164 · Cited by 1
WITHDRAWN: Neural action potential detection based on an adaptive filter for neural recordings
Al-Shueli, A. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.02.237 · Cited by 1
RetractedCrouch, D. A. (1997) · Summit (Simon Fraser University) · Cited by 1
ELECTRICAL NEUROSTIMULATION AND NEUROMODULATION OF VOIDING DYSFUNCTIONS AND PELVIC PAIN
Thon, W. F., & Jonas, U. (1993) · Elsevier eBooks · doi:10.1016/b978-0-444-89958-3.50022-x
New developments in sacral neuromodulation for lower urinary tract dysfunction
Marcelissen, T. A. T. (2011) · Research Publications (Maastricht University) · doi:10.26481/dis.20110930tm
Controlled reshaping of nerve geometry
Caparso, A., & Durand, D. M. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280174
Peripheral Nerve Conduction Block with High Frequency Stimulation via Percutaneous Lead Electrode
Wei, X. (2011) · University of Minnesota Digital Conservancy (University of Minnesota)
Dynamic Rectus Abdominis Muscle Sphincter for Stomal Continence
Bardoel, J. W. J. M. (2002) · Utrecht University Repository (Utrecht University)
Kim, S. (2015) · Korean Journal of Otorhinolaryngology - Head and Neck Surgery · doi:10.3342/kjorl-hns.2015.58.5.299
Yoo, P. B. (2004) · OhioLink ETD Center (Ohio Library and Information Network)
Electrode–Tissue Interface During a Stimulation Cycle
van Dongen, M. N., & Serdijn, W. A. (2016) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-319-28131-5_3
Sun, L., Li, S., Sheng, S., Chen, L., Liu, H., Zhou, H., Zhu, L., Ren, F., & Sun, C. (2016) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei.2016.7852993
“Other studies employing the low frequency ( 1kHz) biphasic pulsing train observed similar nerve injury phenomena although with much longer stimulating periods [6] [7] [8] [9] [10] [11] [12] [13] [14].”
Neurophotonics for Peripheral Nerves
Ahmed, A., Bai, Y., Ramella‐Roman, J. C., & Jung, R. (2017) · CRC Press eBooks · doi:10.1201/9781315373058-31
Bio-implantable microdevices and structures for functional electrical stimulation applications
Korivi, N. S. (2011) · Louisiana State University · doi:10.31390/gradschool_dissertations.4020
“Therefore, for a specific electrode design, it is pertinent to understand the electrical effects at the tissue-electrode interface during the stimulation process [140-143].”
BackgroundNeuroprostheses for Restoring Sensation
Tyler, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00103-0 · Cited by 1
Neuromodulation of Thalamic Sensory Processing of Tactile Stimuli
Rodenkirch, C. (2020) · doi:10.7916/d8-g6pv-0k44
Optimal strategies for electrical stimulation with implantable neuromodulation devices
Eickhoff, S. (2021) · Liverpool John Moores University · doi:10.24377/ljmu.t.00014298
Wang, R., Yu, H., & Li, Z. (2018) · Micro/Nano technologies · doi:10.1007/978-981-10-5945-2_41 · Cited by 1
Huntoon, M. A. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-2216-1.00018-5
DiLorenzo, D. J., & Bronzino, J. D. (2007) · CRC Press eBooks · doi:10.1201/9780849381850-27
A Novel Spike Detection Method for Real-Time Neural Recordings Applications
Al-Shueli, A., & Al-Tahar, I. A. (2023) · Journal Européen des Systèmes Automatisés · doi:10.18280/jesa.560117
Using vagus nerve stimulation to direct synaptic plasticity and treat neurological disease
Hays, S. A., Rennaker, R. L., Wigginton, J. G., & Kilgard, M. P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-12-816996-4.00015-0
Gajewska‐Woźniak, O., Czarkowska‐Bauch, J., Szczepankiewicz, A. A., & Skup, M. (2025) · Acta Neurobiologiae Experimentalis · doi:10.55782/ane-2024-2660
“This form of damage (chronic, occurring over a period of four weeks), resembles that previously described for chronic peripheral nerve compression (Mackinnon et al., 1984) and was occasionally observed after helical electrode implantation around the peroneal nerve in the cat (Agnew et al., 1989).”
InfluentialClosed-loop Control of Peripheral Nerve Stimulation using Resource-efficient Neural Networks
Hwang, Y.-C. E. (2022) · TSpace (University of Toronto)
Bypass neural interfaces for paralysis: clinical translation, challenges and future directions
Lee, M. J. R., Tan, A. K. S., Lo, Y. T., Liu, C., & Jiang, L. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-02082-8
“Sustained or supraphysiological activation lasting up to 16 h can induce over-excitation of nerves or muscles, leading to neuronal hyperactivity, excitotoxcitity and eventual axonal and synaptic degeneration [142, 143].”
Jeong (2000) · doi:10.1002/(sici)1097-4636(200005)50:2
Metadata
- Authors
- Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A.
- Affiliations
- Huntington Medical Research Institutes (US)
- ORCID
- McCreery, Douglas B.
- Venue
- Annals of Biomedical Engineering
- Published
- 1989-01
- Volume
- 17
- Issue
- 1
- Pages
- 39-60
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2049087952
- Cited by
- 185
- References
- 40
- Citations by year
- 2026: 2 · 2024: 7 · 2023: 4 · 2022: 3 · 2021: 9 · 2020: 6 · 2019: 5 · 2018: 9 · 2017: 12 · 2016: 8 · 2015: 7 · 2014: 9 · 2013: 6 · 2012: 5
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (n01ns062397-004)
- National Institute of Neurological Disorders and Stroke (N01-NS-32359, N01-NS-6-2397)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- functional electrical stimulation, peripheral nerves, peroneal nerve, helical electrodes, axonal degeneration, endoneurial edema, stimulation parameters, stimulation frequency, stimulation duration, compound action potential, nerve regeneration
- MeSH terms
- Animals, Cats, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Female, Male, Microscopy, Electron, Nerve Degeneration, Synaptic Transmission, Peripheral Nerves, Peroneal Nerve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.