CoChat

Histologic and physiologic evaluation of electrically stimulated peripheral nerve: Considerations for the selection of parameters

Agnew, William F., McCreery, Douglas B., Yuen, Ted G. H., Bullara, Leo A. · 1989 · Annals of Biomedical Engineering

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

Helical electrodes were implanted around the left and right common peroneal nerves of cats. Three weeks after implantation one nerve was stimulated for 4-16 hours using charge-balanced, biphasic, constant current pulses. Compound action potentials (CAP) evoked by the stimulus were recorded from over the cauda equina before, during and after the stimulation. Light and electron microscopy evaluations were conducted at various times following the stimulation. The mere presence of the electrode invariably resulted in thickened epineurium and in some cases increased peripheral endoneurial connective tissue beneath the electrodes. Physiologic changes during stimulation included elevation of the electrical threshold of the large axons in the nerve. This was reversed within one week after stimulation at a frequency of 20 Hz, but often was not reversed following stimulation at 50-100 Hz. Continuous stimulation at 50 Hz for 8-16 hours at 400 microA or more resulted in neural damage characterized by endoneurial edema beginning within 48 hours after stimulation, and early axonal degeneration (EAD) of the large myelinated fibers, beginning by 1 week after stimulation. Neural damage due to electrical stimulation was decreased or abolished by reduction of the duration of stimulation, by stimulating at 20 Hz (vs. 50 Hz) or by use of an intermittent duty cycle. These results demonstrate that axons in peripheral nerves can be irreversely damaged by 8-16 hours of continuous stimulation at 50 Hz…

Overview

Integrity signals

Registry

Crossref · 10.1007/bf02364272

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

5 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 40 references

Research works printed but not linked: 1

  1. Jacobs, J.; LeQuesne, P.M. Toxic disorders of the nervous system. In: Adams, J.H.; Corsellis, J.A.N.; Duchen, L.W., eds. Greenfield Neuropathology. New York: John Wiley & Sons, 4th Ed.; 1984: pp. 627–698.

Cited by

See all 187

Metadata

Authors
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A.
Affiliations
Huntington Medical Research Institutes (US)
Venue
Annals of Biomedical Engineering
Published
1989-01
Volume
17
Issue
1
Pages
39-60
ISSN
  • 0090-6964 (ISSN-L)
  • 1573-9686
OpenAlex
W2049087952
Cited by
185
References
40
Citations by year
2026: 2 · 2024: 7 · 2023: 4 · 2022: 3 · 2021: 9 · 2020: 6 · 2019: 5 · 2018: 9 · 2017: 12 · 2016: 8 · 2015: 7 · 2014: 9 · 2013: 6 · 2012: 5
FWCI
2.33
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (n01ns062397-004)
  • National Institute of Neurological Disorders and Stroke (N01-NS-32359, N01-NS-6-2397)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
functional electrical stimulation, peripheral nerves, peroneal nerve, helical electrodes, axonal degeneration, endoneurial edema, stimulation parameters, stimulation frequency, stimulation duration, compound action potential, nerve regeneration
MeSH terms
Animals, Cats, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Female, Male, Microscopy, Electron, Nerve Degeneration, Synaptic Transmission, Peripheral Nerves, Peroneal Nerve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.