Histologic and physiologic evaluation of electrically stimulated peripheral nerve: Considerations for the selection of parameters
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Helical electrodes were implanted around the left and right common peroneal nerves of cats. Three weeks after implantation one nerve was stimulated for 4-16 hours using charge-balanced, biphasic, constant current pulses. Compound action potentials (CAP) evoked by the stimulus were recorded from over the cauda equina before, during and after the stimulation. Light and electron microscopy evaluations were conducted at various times following the stimulation. The mere presence of the electrode invariably resulted in thickened epineurium and in some cases increased peripheral endoneurial connective tissue beneath the electrodes. Physiologic changes during stimulation included elevation of the electrical threshold of the large axons in the nerve. This was reversed within one week after stimulation at a frequency of 20 Hz, but often was not reversed following stimulation at 50-100 Hz. Continuous stimulation at 50 Hz for 8-16 hours at 400 microA or more resulted in neural damage characterized by endoneurial edema beginning within 48 hours after stimulation, and early axonal degeneration (EAD) of the large myelinated fibers, beginning by 1 week after stimulation. Neural damage due to electrical stimulation was decreased or abolished by reduction of the duration of stimulation, by stimulating at 20 Hz (vs. 50 Hz) or by use of an intermittent duty cycle. These results demonstrate that axons in peripheral nerves can be irreversely damaged by 8-16 hours of continuous stimulation at 50 Hz…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, its open structural shape explains the low selectivity of the electrode (Agnew et al., 1989) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Agnew et al., 1989
In the citing paper
“Initial issues with implantable extraneural electrodes often result from mechanical constriction and injury to the nerve during the surgical implantation process [43, 44].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
In the citing paper
“The safety of acute and chronic peripheral nerve stimulation has been demonstrated in animals and humans for pulse durations from 1 to 300 μs for the purpose of motor function and sensory feedback [43, 44, 75]”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
In the citing paper
“As discussed previously, the length of stimulation application has been shown to influence the degree of induced neural damage.”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
In the citing paper
“Their results showed no neural damage after continuous stimulation at 20 Hz for 16 h. However, with otherwise identical parameters, a frequency of 50 Hz resulted in neural damage.”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [44]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
(1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-101-4-579_1 · Cited by 525
Pathoanatomy and Pathophysiology of Nerve Root Compression
RYDEVIK, B., BROWN, M. D., & LUNDBORG, G. (1984) · Spine · doi:10.1097/00007632-198401000-00004 · Cited by 503
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 359
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · cited 1×
“The presence of a delay between the first and second phases of the pulse pair allows more efficient excitation of smaller axons (16); with an interval less than 300 #s, the amplitude of the later components of the CAP (representing smaller, more slowly conducting myelinated axons) was attenuated.”
BackgroundSacral anterior root stimulators for bladder control in paraplegia
Brindley, G. S., Polkey, C. E., & Rushton, D. N. (1982) · Spinal Cord · doi:10.1038/sc.1982.65 · Cited by 311 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundChronic Nerve Compression—an Experimental Model in the Rat
Mackinnon, S. E., Dellon, A. L., Hudson, A. R., & Hunter, D. A. (1984) · Annals of Plastic Surgery · doi:10.1097/00000637-198408000-00004 · Cited by 307 · cited 1×
“This type of neural damage closely resembles that previously described for chronic peripheral nerve compression ( 23 ).”
BackgroundBoyd, I. A., & Kalu, K. U. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012737 · Cited by 197 · cited 2×
“The alpha component is generated mainly by large myelinated axons which, in the cat sciatic nerve, have conduction velocities centered around 70-90 m/sec, and have outside diameters of 10/~m or more (6).”
BackgroundResultLong-term pain control by direct peripheral-nerve stimulation.
Nashold, B. S., Goldner, J. L., Mullen, J. B., & Bright, D. S. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00001 · Cited by 184 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundA DESCRIPTIVE STUDY OF THE BLOOD VESSELS OF THE SCIATIC NERVE IN THE RAT, MAN AND OTHER MAMMALS
BELL, M. A. (1984) · Brain · doi:10.1093/brain/107.3.871 · Cited by 163 · cited 1×
“This is in keeping with the well known adaptability provided by the intraneural microvascular system (1,4,30).”
BackgroundWaters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundExperimental correction of footdrop by electrical stimulation of the peroneal nerve
Waters, R., McNeal, D., & Perry, J. (1975) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197557080-00002 · Cited by 153 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundGillespie, M. J., & Stein, R. B. (1983) · Brain Research · doi:10.1016/0006-8993(83)91065-x · Cited by 143 · cited 1×
“The pattern of, axonal degeneration induced by electrical stimulation observed in the present study closely resembles the sequence of events following cutting or ligation of nerve (13,26) or following Isoniazid neuropathy (6,19).”
ResultDistribution of nodes and incisures in normal and regenerated nerve fibers
Hiscoe, H. B. (1947) · The Anatomical Record · doi:10.1002/ar.1090990404 · Cited by 139
Functional electrical stimulation : applications in neural prostheses
Hambrecht, F. T., RESWICK, J. B., & Disorders, C. (1977) · M. Dekker eBooks · Cited by 135
Pain Suppression by Peripheral Nerve Stimulation
Picaza, J. A., Hunter, S. E., & Cannon, B. W. (1977) · Stereotactic and Functional Neurosurgery · doi:10.1159/000102446 · Cited by 109 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundDavis, L. A., Gordon, T., Hoffer, J. A., Jhamandas, J., & Stein, R. B. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012588 · Cited by 103
Restoration of fast muscle characteristics following cessation of chronic stimulation
Eisenberg, B. R., Brown, J. C., & Salmons, S. (1984) · Cell and Tissue Research · doi:10.1007/bf00217292 · Cited by 98
Adams, W. E. (1943) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a070234 · Cited by 76 · cited 1×
“This is in keeping with the well known adaptability provided by the intraneural microvascular system (1,4,30).”
BackgroundControl of Pain by Direct Electrical Stimulation of Peripheral Nerves
Sweet, W. H. (1976) · Neurosurgery · doi:10.1093/neurosurgery/23.cn_suppl_1.103 · Cited by 76 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundTreatment of drop foot using an implantable peroneal underknee stimulator
Strojnik, P., Aćimović, R., Vavken, E., Simic, V., & Stanič, U. (1987) · Clinical Biomechanics · doi:10.1016/0268-0033(87)90024-6 · Cited by 74
Treatment of Drop Foot Using an Implantable Peroneal Underknee Stimulator
Strojnik, P., Acimovic, R., Vavken, E., Simic, V, & Stanic, U. (2020) · Journal of Rehabilitation Medicine · doi:10.2340/1650197787193743 · Cited by 60 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundAsbury, A. K. (1973) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-197304000-00011 · Cited by 55 · cited 1×
“Other mechanically-induced effects included crescents of endoneurial connective tissue resembling "Renaut Bodies" (3) (most frequently situated subperineurally at the periphery of cross sections of the nerve and at the level of the electrode (Fig.”
BackgroundFunctional Pattern of Sacral Root Stimulation in Dogs I. Micturition
Thüroff, J. W., Bazeed, M. A., Schmidt, R. A., Wiggin, D. M., & Tanagho, E. A. (1982) · Journal of Urology · doi:10.1016/s0022-5347(17)54182-8 · Cited by 54 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundKim, J. H., Manuelidis, E. E., Glenn, W. W. L., & Kaneyuki, T. (1976) · PubMed · Cited by 54
Electrical control of facial pain
Shelden, C. H., Pudenz, R. H., & Doyle, J. (1967) · The American Journal of Surgery · doi:10.1016/0002-9610(67)90374-1 · Cited by 53 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundPeripheral nerve injury and recovery after temporary ischemia
M�kitie, J., & Ter�v�inen, H. (1977) · Acta Neuropathologica · doi:10.1007/bf00684541 · Cited by 48 · cited 1×
“Also, the pattern of damage is quite different from that induced by temporary nerve ischemia in which the smallest myelinated fibers also are damaged (25).”
BackgroundLight and electron microscopic studies of phrenic nerves after long-term electrical stimulation
Kim, J. H., Manuelidis, E. E., Glenn, W. W. L., Fukuda, Y., Cole, D. S., & Hogan, J. F. (1983) · Journal of Neurosurgery · doi:10.3171/jns.1983.58.1.0084 · Cited by 47 · cited 2×
“Other investigators have also demonstrated that prolonged stimulation of peripheral nerve need not be damaging provided that the frequency is reasonably low and/or an interrupted stimulus protocol is employed (12,20).”
BackgroundElectrical stimulation of peripheral nerve
Swett, J. E., & Bourassa, C. M. (1981) · Electrical Stimulation Research Techniques · doi:10.1016/b978-0-12-547440-5.50016-4 · Cited by 39
Kim (1976) · doi:10.1016/s0022-5223(19)40049-4 · Cited by 38 · cited 1×
“Kim et aL (21) carried out histologic observations on seven of Glenn's patients in which the phrenic nerve had been pulsed for periods up to four years.”
BackgroundRegeneration of cauda equina fibres after transsection and end-to-end suture
Meier, C., & Sollmann, H. (1977) · Journal of Neurology · doi:10.1007/bf00313055 · Cited by 26 · cited 1×
“The pattern of, axonal degeneration induced by electrical stimulation observed in the present study closely resembles the sequence of events following cutting or ligation of nerve (13,26) or following Isoniazid neuropathy (6,19).”
ResultLong-term, continuous electrostimulation of a peripheral nerve.
DeVilliers, R., Nosé, Y., Meier, W., & KANTROWITZ, A. R. (1964) · PubMed · Cited by 25
Micturition and the male genitourinary response to sacral root stimulation.
Ra, S., Bruschini, H., Van Gool, J., & Ea, T. (1979) · PubMed · Cited by 24
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1984) · Neurosurgery · doi:10.1227/00006123-198404000-00010 · Cited by 23
Self-citationRegeneration of cauda equina fibres after transsection and end-to-end suture
Meier, C., & Sollmann, H. (1977) · Journal of Neurology · doi:10.1007/bf02402141 · Cited by 20
Experience with Implanted Electrodes at Rancho Los Amigos Hospital
McNeal, D. R., Waters, R., & Reswick, J. (1977) · Stereotactic and Functional Neurosurgery · doi:10.1159/000102447 · Cited by 15 · cited 2×
“(24) described implantations of cuff electrodes on peroneal nerves for the treatment of foot drop in 31 patients, for periods up to 7.”
BackgroundDiaphragm pacing by electrical stimulation of the phrenic nerve
Glenn, W. W., & Phelps, M. L. (1985) · Neurosurgery · doi:10.1097/00006123-198512000-00021 · Cited by 15 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundHistologic Changes in Continuous, Long-Term Electrical Stimulation of a Peripheral Nerve
Hershberg, P. I., Sohn, D., Agrawal, G. P., & Kantrowitz, A. (1967) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1967.4502479 · Cited by 15 · cited 1×
“In spite of the considerable clinical experience, there have been few studies aimed at determining the relative contribution of mechanical and electrical factors to the neural damage which is often incurred with chronic stimulation (17,20,37,40).”
BackgroundElectrostimulation of the median nerve in tetraplegics by means of implanted stimulators
Kiwerski, J. E., Weiss, M., & Paśniczek, R. (1983) · Spinal Cord · doi:10.1038/sc.1983.54 · Cited by 14 · cited 1×
“These include respiratory pacing (14,15,35), lower extremity neuromuscular assist (24,33,38,39,41), upper extremity neuromuscular assist (22), control of intractable pain (9,28,29,32,34) and electromicturition and urinary incontinence (7,31,36).”
BackgroundREMODELLING OF NERVE STRUCTURE IN EXPERIMENTAL ISONIAZID NEUROPATHY IN THE RAT
Beuche, W., & Friede, R. L. (1986) · Brain · doi:10.1093/brain/109.4.759 · Cited by 7 · cited 1×
“However, in experimental Isoniazid neuropathy (5), there was a toxic effect on the entire fiber population.”
BackgroundImplanted devices for electronic augmentation of nervous system function.
Burton, C. (1975) · PubMed · Cited by 6
Research works printed but not linked: 1
- Jacobs, J.; LeQuesne, P.M. Toxic disorders of the nervous system. In: Adams, J.H.; Corsellis, J.A.N.; Duchen, L.W., eds. Greenfield Neuropathology. New York: John Wiley & Sons, 4th Ed.; 1984: pp. 627–698.
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“However, its open structural shape explains the low selectivity of the electrode (Agnew et al., 1989).”
BackgroundSoft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Self-citationElectrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
“p(t') = [V(f) - Vos(t')] A/I(f) t, (2)”
Background
Metadata
- Authors
- Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A.
- Affiliations
- Huntington Medical Research Institutes (US)
- ORCID
- McCreery, Douglas B.
- Venue
- Annals of Biomedical Engineering
- Published
- 1989-01
- Volume
- 17
- Issue
- 1
- Pages
- 39-60
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2049087952
- Cited by
- 185
- References
- 40
- Citations by year
- 2026: 2 · 2024: 7 · 2023: 4 · 2022: 3 · 2021: 9 · 2020: 6 · 2019: 5 · 2018: 9 · 2017: 12 · 2016: 8 · 2015: 7 · 2014: 9 · 2013: 6 · 2012: 5
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (n01ns062397-004)
- National Institute of Neurological Disorders and Stroke (N01-NS-32359, N01-NS-6-2397)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- functional electrical stimulation, peripheral nerves, peroneal nerve, helical electrodes, axonal degeneration, endoneurial edema, stimulation parameters, stimulation frequency, stimulation duration, compound action potential, nerve regeneration
- MeSH terms
- Animals, Cats, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Female, Male, Microscopy, Electron, Nerve Degeneration, Synaptic Transmission, Peripheral Nerves, Peroneal Nerve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.