In vitro and in vivo characterization of porous poly‐L‐lactic acid coatings for subcutaneously implanted glucose sensors
Open accessAbstract
The purpose of this study was to test the hypothesis that porous poly‐L‐lactic acid (PLLA) sensor coatings reduce fibrosis and promote blood microvessel formation in tissue adjacent to the sensor surface. Porous PLLA coatings were produced using ammonium bicarbonate as the gas foaming/salt leaching agent, and deployed on functional and nonfunctional sensors. The porous coatings minimally affected sensor accuracy and response rate in vitro. Three‐week subcutaneous rat studies of nonfunctional glucose sensors showed the anticipated effect of porous coatings enhancing vascularity and decreasing collagen deposition. In contrast, percutaneous functional sensors with and without porous coatings showed no significant difference in terms of histology or sensor response. In spite of the observation that texturing increases the vascularity of the tissue that surrounds implanted sensors, other factors such as the additional mechanical stresses imposed by percutaneous tethering may override the beneficial effects of the porous coatings. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Subcutaneous histology of a porous PLLA coating showed a threefold increase in vascularization and about a 65% reduction in collagen compared with bare glucose sensors at 3 weeks.
“Subcutaneous histology of a porous poly-L-lactic acid (PLLA) coating showed a threefold increase in vascularization and a ~65% reduction in collagen compared to bare glucose sensors at 3 weeks.121”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
When the same materials were implanted percutaneously, histological differences were less apparent, with porous coatings giving a twofold increase in vascularization and a twofold increase in collagen content compared with bare sensors at 2 weeks.
“when the same materials were implanted percutaneously, histological differences were less apparent, with porous coatings giving a twofold increase in vascularization and a twofold increase, rather than decrease, in collagen content compared to bare sensors at 2 weeks.121”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
Subcutaneous implants had no blood vessels or collagen inside the porous material, while percutaneous experiments showed significant collagen and vascularization, indicating a differential FBR depending on whether the implant was purely subcutaneous or percutaneous.
“While examination of the subcutaneous implant noted no blood vessels or collagen within the interior of the porous material, the percutaneous experiments revealed significant levels of collagen and vascularization, indicating a differential FBR dependent on the nature (i.e., purely subcutaneous vs. percutaneous) of the implant.121”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
Micromotion effects overrode the benefits of porosity because of the continual movement of the percutaneously implanted sensor in the tissue.
“These effects overrode the benefits of porosity due to the continual movement of the percutaneously implanted sensor in the tissue.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
Incorporating strategies that reduce micromotion may be critical to fully realize the potential of porous membranes on percutaneous sensors.
“Thus, incorporating strategies that reduced the effects of micromotion may be critical to fully realize the potential of porous membranes on percutaneous sensors.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
Coatings on percutaneous sensors did not produce similar histological or sensor performance improvements compared with bare sensors.
“However, coatings on percutaneous sensors did not lead to similar histological or sensor performance improvements versus control (i.e., bare) sensors.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
PLLA foams on non-functioning sensors implanted subcutaneously showed decreased collagen capsule thickness and increased capillary density compared with bare non-functional sensors.
“When coated onto non-functioning sensors and implanted subcutaneously, the PLLA foams exhibited the expected decrease in collagen capsule thickness and increased capillary density compared to bare non-functional sensors.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
The difference in performance between the two implant modes was attributed to micromotion.
“The difference in performance between the two implant modes was attributed by the authors to micromotion.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [121]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A. S., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,396 · see citing works
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · see citing works
Ramay, H. R., & Zhang, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00171-6 · Cited by 545 · see citing works
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · see citing works
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517 · see citing works
Three-dimensional nano-HAp/collagen matrix loading with osteogenic cells in organ culture
Du, C., Cui, F. Z., Zhu, X. D., & de Groot, K. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990315)44:4 · Cited by 365 · see citing works
Characterization of implantable biosensor membrane biofouling
Wisniewski, N. A., Moussy, F. G., & Reichert, W. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 351 · see citing works
Self-citationBrain micromotion around implants in the rodent somatosensory cortex
Gilletti, A., & Muthuswamy, J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/001 · Cited by 307 · see citing works
Long-term engraftment of hepatocytes transplanted on biodegradable polymer sponges
Mooney, D. J., Sano, K., Kaufmann, P. M., Majahod, K., Schloo, B. L., Vacanti, J. P., & Langer, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3 · Cited by 233 · see citing works
Koschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181 · see citing works
Self-citationWard, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00160-6 · Cited by 176 · see citing works
Inhibition of implant-associated infections via nitric oxide release
Nablo, B. J., Prichard, H. L., Butler, R. D., Klitzman, B. M., & Schoenfisch, M. H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.017 · Cited by 176 · see citing works
Self-citationWound dressing with sustained anti-microbial capability
Loke, W., Lau, S.-K., Yong, L. L., Khor, E., & Chow, K. S. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(2000)53:1 · Cited by 175 · see citing works
The pathology of total joint arthroplasty
Bauer, T. W., & Schils, J. (1999) · Skeletal Radiology · doi:10.1007/s002560050552 · Cited by 172 · see citing works
Biomaterial–microvasculature interactions
Sieminski, A. L., & Gooch, K. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00149-6 · Cited by 155 · see citing works
Yu, B., Long, N., Moussy, Y., & Moussy, F. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.11.002 · Cited by 141 · see citing works
The pathology of total joint arthroplasty
Bauer, T. W., & Schils, J. P. (1999) · Skeletal Radiology · doi:10.1007/s002560050541 · Cited by 139 · see citing works
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
Updike, S. J., Shults, M. C., Gilligan, B. J., & Rhodes, R. K. (2000) · Diabetes Care · doi:10.2337/diacare.23.2.208 · Cited by 135 · see citing works
Norton, L. W., Tegnell, E., Toporek, S. S., & Reichert, W. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.069 · Cited by 104 · see citing works
Self-citationA technique to prevent dural adhesions to chronically implanted microelectrode arrays
Maynard, E. M., Fernández, E., & Normann, R. A. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00159-x · Cited by 102 · see citing works
Mediation of <i>in vivo</i> glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96 · see citing works
Effects of surface topography on the connective tissue attachment to subcutaneous implants.
Kim, H., Murakami, H., Chehroudi, B., Textor, M., & Brunette, D. M. (2006) · PubMed · Cited by 92 · see citing works
How Fibroblasts and Giant Cells Encapsulate Implants: Considerations in Design of Glucose Sensors
Woodward, S. C. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.278 · Cited by 89 · see citing works
Feasibility of Continuous Long-Term Glucose Monitoring from a Subcutaneous Glucose Sensor in Humans
Gilligan, B. C., Shults, M., Rhodes, R. K., Jacobs, P. G., Brauker, J. H., Pintar, T. J., & Updike, S. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198089 · Cited by 71 · see citing works
Improving the biocompatibility of in vivo sensors via nitric oxide release
Shin, J. H., & Schoenfisch, M. H. (2006) · The Analyst · doi:10.1039/b600129g · Cited by 66 · see citing works
Winet, H., & Bao, J. Y. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980615)40:4 · Cited by 44 · see citing works
Schubert, M. A., Wiggins, M. J., Anderson, J. M., & Hiltner, A. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19970315)34:4 · Cited by 41 · see citing works
Ward, W. K., Wood, M. D., Casey, H. M., Quinn, M. J., & Federiuk, I. F. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731320 · Cited by 39 · see citing works
Pentobarbital anesthesia suppresses basal and 2-deoxy-D-glucose-stimulated plasma catecholamines
Taborsky, G. J., Halter, J. B., Baum, D., et al. (1984) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1984.247.5.r905 · Cited by 33 · see citing works
Knowles, N. G., Miyashita, Y., Usui, M. L., Marshall, A. J., Pirrone, A., Hauch, K. D., Ratner, B. D., Underwood, R. A., Fleckman, P. H., & Olerud, J. E. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30384 · Cited by 29 · see citing works
Effect of microtextured surfaces on the performance of percutaneous devices
Walboomers, X. F., & Jansen, J. A. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30337 · Cited by 27 · see citing works
Tagusari, O., Yamazaki, K., Litwak, P., et al. (1998) · Artificial Organs · doi:10.1046/j.1525-1594.1998.06152.x · Cited by 20 · see citing works
Corticosteroid Modulation of Tissue Responses to Implanted Sensors
Friedl, K. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.898 · Cited by 15 · see citing works
Strategies for Testing Long-Term Transcutaneous Amperometric Glucose Sensors
Long, N., Yu, B., Moussy, Y., & Moussy, F. G. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.927 · Cited by 14 · see citing works
Zapp, M., Kofke, W. A., & Davis, D. W. (1992) · Neurochemical Research · doi:10.1007/bf00974569 · Cited by 11 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [21]Sharkawy AA Klitzman B Truskey GA Reichert WM Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties J Biomed Mater Res 1998 40 586 597 9599035
- [32]Biological reactivity tests, in vitro United States Pharmacopeia 2002 Chapter 87 2525 2526 United States Pharmacopeial Convention Rockville, Maryland
Cited by
Sorted by citations
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102 · see citing works
The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Nichols, S. P., Koh, A., Brown, N. L., Rose, M. B., Sun, B., Slomberg, D. L., Riccio, D. A., Klitzman, B., & Schoenfisch, M. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.053 · Cited by 67 · see citing works
Self-citationNovak, M. T., Yuan, F., & Reichert, W. M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4097-6 · Cited by 55 · see citing works
Self-citationThe Role of Macrophages in the Foreign Body Response to Implanted Biomaterials
Yu, T., Tutwiler, V. J., & Spiller, K. (2015) · Biomaterials in Regenerative Medicine and the Immune System · doi:10.1007/978-3-319-18045-8_2 · Cited by 39 · see citing works
Increased<i>In Vivo</i>Glucose Recovery via Nitric Oxide Release
Nichols, S. P., Le, N. N., Klitzman, B., & Schoenfisch, M. H. (2011) · Analytical Chemistry · doi:10.1021/ac103070t · Cited by 26 · see citing works
Self-citationIntravital microscopy evaluation of angiogenesis and its effects on glucose sensor performance
Koschwanez, H. E., Reichert, W. M., & Klitzman, B. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32630 · Cited by 15 · see citing works
Self-citationPercutaneous Window Chamber Method for Chronic Intravital Microscopy of Sensor—Tissue Interactions
Koschwanez, H. E., Klitzman, B., & Reichert, W. M. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200608 · Cited by 9 · see citing works
Self-citation
- Authors
- Koschwanez, H. E., Yap, F. Y., Klitzman, B., & Reichert, W. M.
- Affiliations
- Duke University (US)
- Corresponding author
- Reichert, W. M.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2008-01-15
- Volume
- 87A
- Issue
- 3
- Pages
- 792-807
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- PMC
- PMC4031458
- OpenAlex
- W2071543700
- Cited by
- 69
- References
- 35
- Citations by year
- 2024: 3 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 1 · 2019: 3 · 2017: 5 · 2016: 6 · 2015: 9 · 2014: 6 · 2013: 5 · 2012: 4
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Biomedical Materials Research Part A (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- ResearchSpace (University of Auckland) (submittedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK054932, DK054932, R56DK054932)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- poly(L-lactic acid), porous coatings, glucose sensor, subcutaneous implantation, fibrosis, angiogenesis, collagen deposition, salt leaching, biodegradable polymers, implant surface modification
- MeSH terms
- Animals, Blood Glucose, Male, Polyesters, Polymers, Surface Properties, Biosensing Techniques, Porosity, Rats, Sprague-Dawley, Lactic Acid, Coated Materials, Biocompatible, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review