In vitro and in vivo characterization of porous poly‐L‐lactic acid coatings for subcutaneously implanted glucose sensors

Open access
Koschwanez, H. E., Yap, F. Y., Klitzman, B., Reichert, W. M.·2008·Journal of Biomedical Materials Research Part A

Abstract

The purpose of this study was to test the hypothesis that porous poly‐L‐lactic acid (PLLA) sensor coatings reduce fibrosis and promote blood microvessel formation in tissue adjacent to the sensor surface. Porous PLLA coatings were produced using ammonium bicarbonate as the gas foaming/salt leaching agent, and deployed on functional and nonfunctional sensors. The porous coatings minimally affected sensor accuracy and response rate in vitro. Three‐week subcutaneous rat studies of nonfunctional glucose sensors showed the anticipated effect of porous coatings enhancing vascularity and decreasing collagen deposition. In contrast, percutaneous functional sensors with and without porous coatings showed no significant difference in terms of histology or sensor response. In spite of the observation that texturing increases the vascularity of the tissue that surrounds implanted sensors, other factors such as the additional mechanical stresses imposed by percutaneous tethering may override the beneficial effects of the porous coatings. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2008

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.31824

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Subcutaneous histology of a porous PLLA coating showed a threefold increase in vascularization and about a 65% reduction in collagen compared with bare glucose sensors at 3 weeks.

    “Subcutaneous histology of a porous poly-L-lactic acid (PLLA) coating showed a threefold increase in vascularization and a ~65% reduction in collagen compared to bare glucose sensors at 3 weeks.121”
  • When the same materials were implanted percutaneously, histological differences were less apparent, with porous coatings giving a twofold increase in vascularization and a twofold increase in collagen content compared with bare sensors at 2 weeks.

    “when the same materials were implanted percutaneously, histological differences were less apparent, with porous coatings giving a twofold increase in vascularization and a twofold increase, rather than decrease, in collagen content compared to bare sensors at 2 weeks.121”
  • Subcutaneous implants had no blood vessels or collagen inside the porous material, while percutaneous experiments showed significant collagen and vascularization, indicating a differential FBR depending on whether the implant was purely subcutaneous or percutaneous.

    “While examination of the subcutaneous implant noted no blood vessels or collagen within the interior of the porous material, the percutaneous experiments revealed significant levels of collagen and vascularization, indicating a differential FBR dependent on the nature (i.e., purely subcutaneous vs. percutaneous) of the implant.121”
  • Micromotion effects overrode the benefits of porosity because of the continual movement of the percutaneously implanted sensor in the tissue.

    “These effects overrode the benefits of porosity due to the continual movement of the percutaneously implanted sensor in the tissue.”
  • Incorporating strategies that reduce micromotion may be critical to fully realize the potential of porous membranes on percutaneous sensors.

    “Thus, incorporating strategies that reduced the effects of micromotion may be critical to fully realize the potential of porous membranes on percutaneous sensors.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [21]Sharkawy AA Klitzman B Truskey GA Reichert WM Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties J Biomed Mater Res 1998 40 586 597 9599035
  2. [32]Biological reactivity tests, in vitro United States Pharmacopeia 2002 Chapter 87 2525 2526 United States Pharmacopeial Convention Rockville, Maryland

Cited by

Sorted by citations

Authors
Koschwanez, H. E., Yap, F. Y., Klitzman, B., & Reichert, W. M.
Affiliations
Duke University (US)
Corresponding author
Reichert, W. M.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2008-01-15
Volume
87A
Issue
3
Pages
792-807
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2071543700
Cited by
69
References
35
Citations by year
2024: 3 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 1 · 2019: 3 · 2017: 5 · 2016: 6 · 2015: 9 · 2014: 6 · 2013: 5 · 2012: 4
FWCI
6.28
Type
journal article
Language
en
Open access
Locations
  • Journal of Biomedical Materials Research Part A (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • ResearchSpace (University of Auckland) (submittedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (R01DK054932, DK054932, R56DK054932)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
poly(L-lactic acid), porous coatings, glucose sensor, subcutaneous implantation, fibrosis, angiogenesis, collagen deposition, salt leaching, biodegradable polymers, implant surface modification
MeSH terms
Animals, Blood Glucose, Male, Polyesters, Polymers, Surface Properties, Biosensing Techniques, Porosity, Rats, Sprague-Dawley, Lactic Acid, Coated Materials, Biocompatible, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review