Study of the effects of tissue reactions on the function of implanted glucose sensors

Dungel, Paul, Long, Nathan, Yu, Bazhang, Moussy, Yvonne, Moussy, Francis·2008·Journal of Biomedical Materials Research Part A

Abstract

The relationship between tissue reactions to a subcutaneously implanted glucose sensor and the function of the sensor was evaluated over a period of 4‐weeks using tubular, porous polyvinyl alcohol (PVA) sponges implanted subcutaneously in rats. The PVA sponges were used as scaffolds in which the foreign body response could develop. Coil‐type glucose sensors were then placed in the center of the PVA sponges and tested on day 3, and weekly thereafter. In the first approach, the sensors were placed in the sponges still implanted in the rats and tested. In vivo glucose sensor sensitivity peaked at day 7 and steadily decreased until day 35. In the second approach, the sensors were placed in the explanted sponges and then tested. This test showed no sensor function after day 7, indicating that functional blood vessels are critical in maintaining any function whatsoever. In both cases the sensors themselves were never implanted to eliminate any potential in vivo degradation of the sensors that could have affected the outcome of this study. Sensors were then tested in absence of sponges and found to be working properly with no change from preimplantation sensitivity. Once sensor testing was concluded, the PVA sponge/tissue samples were prepared for quantitative histological analysis. It was determined that the increase in collagen deposition within the sponge correlated with the decrease in sensor sensitivity. It was also observed that natural angiogenesis (peak at day 14) did not overcome the barrier to glucose diffusion created by the fibrous capsule. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008

Integrity signals

Registry

Crossref · 10.1002/jbm.a.31593

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Glucose sensitivity correlated with collagen encapsulation of the sponges, with thicker collagen producing greater sensitivity loss.

    “Glucose sensitivity correlated well with the collagen encapsulation of the sponges with thicker collagen resulting in greater sensitivity loss.108”
  • In vivo glucose sensitivity peaked at day 7 and then decreased for the remainder of the study.

    “The glucose sensitivity in vivo peaked at day 7, but then decreased for the duration of the study.108”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dungel, P., Long, N., Yu, B., Moussy, Y., & Moussy, F.
Affiliations
University of South Florida (US)
Corresponding author
Moussy, Francis
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2007-09-17
Volume
85A
Issue
3
Pages
699-706
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2044430285
Cited by
47
References
28
Citations by year
2021: 1 · 2020: 2 · 2018: 3 · 2017: 3 · 2016: 1 · 2015: 3 · 2014: 2 · 2013: 10 · 2012: 4
FWCI
4.09
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research Part A (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Biomedical Imaging and Bioengineering (R0I EB001640)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
glucose sensor, foreign body reaction, tissue reaction, subcutaneous implantation, polyvinyl alcohol sponge, collagen deposition, angiogenesis, fibrous capsule, sensor sensitivity
MeSH terms
Animals, Blood Glucose, Collagen, Materials Testing, Polyvinyl Alcohol, Blood Glucose Self-Monitoring, Surgical Sponges, Monitoring, Ambulatory, Neovascularization, Physiologic, Implants, Experimental, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review