Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bioprocessing
Open accessThe DOI matches its Crossref record; 102 of the 103 references it cites were found in a registry or an index.
Abstract
Adoption of Quality by Design (QbD) principles, regulatory support of QbD, process analytical technology (PAT), and continuous manufacturing are major factors effecting new approaches to pharmaceutical manufacturing and bioprocessing. In this review, we highlight new technology developments, data analysis models, and applications of Raman spectroscopy, which have expanded the scope of Raman spectroscopy as a process analytical technology. Emerging technologies such as transmission and enhanced reflection Raman, and new approaches to using available technologies, expand the scope of Raman spectroscopy in pharmaceutical manufacturing, and now Raman spectroscopy is successfully integrated into real-time release testing, continuous manufacturing, and statistical process control. Since the last major review of Raman as a pharmaceutical PAT in 2010, many new Raman applications in bioprocessing have emerged. Exciting reports of in situ Raman spectroscopy in bioprocesses complement a growing scientific field of biological and biomedical Raman spectroscopy. Raman spectroscopy has made a positive impact as a process analytical and control tool for pharmaceutical manufacturing and bioprocessing, with demonstrated scientific and financial benefits throughout a product's lifecycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Schematic comparing variants of sample excitation (solid line) and signal collection [dashed line(s)] used in Raman spectroscopy in measuring turbid media. (a) Backscattered Raman is a commonly used geometry that uses a single site of excitation with collection of signal close (<1 mm) to the excitation. As applied to Raman microscopy, this approach is called epi-illumination as a single microscope objective is used to excite the sample and collect Raman signal. The sampling volume in backscattered Raman is generally small, both in the lateral and axial dimensions. Thus, backscattered Raman is a good approach for measuring a surface. (b) Overlapping a defocused or wide laser beam with multiple collection fibers in a backscattering-like geometry is called wide area Raman (also known as large volumetric or global illumination Raman). (c) Separating collection fibers from the sample excitation by a small distance (Δd = 1–6 mm) enables collection of diffusely scattered Raman photons, known as a spatially-offset Raman spectroscopy (SORS). (d) Transmission Raman collects Raman photons diffusely scattered through a sample. Wide area, spatially-offset Raman spectroscopy (SORS) and transmission Raman provides representative sampling in turbid media and enables collection of Raman signal from buried layers in a layered sample](https://figures.cochat.ai/paper-figures/e5a0bbbc329941ad87050f571a218a65/raman-spectroscopy-as-a-process-analytical-technology-for-pharmaceutical-figure-1.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the monitoring of intracellular and extracellular macromolecules in bioprocesses share many intrinsic similarities to yeast and bacteria bioprocesses, which have been extensively reviewed together due to these similarities [20,21,29].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [29]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Since our critical review of Raman spectroscopy in pharmaceutical manufacturing and bioprocessing in 2016 [18], we have seen developments in the use of Raman variants or enhancement strategies in basic science applications, expansion of in situ Raman measurements in upstream bioprocessing, and increasing compatibility of process Raman with process automation.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
The cited source says what the claim attributes to it.
In the citing paper
“Variations in the geometry of optical fibers and lenses within the probe can enable a variety of sampling options including backscattered, large volumetric, spatially offset Raman, and transmission Raman.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
In the citing paper
“These include the need for large and representative datasets, optimal preprocessing techniques, handling environmental and noise sensitivities, high initial costs, and ensuring regulatory compliance [67].”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [67]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Production of recombinant protein therapeutics in cultivated mammalian cells
Wurm, F. M. (2004) · Nature Biotechnology · doi:10.1038/nbt1026 · Cited by 2,032 · cited 1×
“Production of protein therapeutics by mammalian cells is the most widely used bioprocess because of its ability to properly produce and fold a recombinant protein, with 60–70 % of biopharmaceuticals using this bioprocess [79, 80].”
BackgroundReference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 1×
“There are excellent reviews providing Raman spectra of biomolecules, complete with tables of band assignments [66, 67].”
BackgroundTissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352 · cited 1×
“Most cell and tissue spectroscopy is performed in the Btherapeutic^ near-infrared window (650– 1350 nm) because optical scattering is dominant and water absorption is at a minimum [14, 15].”
BackgroundBabuška, R. (1998) · International Series in Intelligent Technologies · doi:10.1007/978-94-011-4868-9 · Cited by 1,318
Biological Applications of Raman Spectroscopy
(2000) · Infrared and Raman Spectroscopy of Biological Materials · doi:10.1201/b16936-17 · Cited by 1,088
Sturgeon, R. (1988) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/0584-8547(88)80189-7 · Cited by 979
Vo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681 · cited 1×
“API or excipient particles and cellular organelles, such as mitochondria and nuclei, also strongly scatter light [16, 17].”
BackgroundMascia, S., Heider, P. L., Zhang, H., Lakerveld, R., Benyahia, B., Barton, P. I., Braatz, R. D., Cooney, C. L., Evans, J. M. B., Jamison, T. F., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305429 · Cited by 599
De Beer, T., Burggraeve, A., Fonteyne, M., Saerens, L., Remon, J. P., & Vervaet, C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.012 · Cited by 559
Research works printed but not linked: 4
- Slater JB Tedesco TM Fairchild RC Lewis IR Lewis IR Edwards HGM Raman spectrometry and its adaptation to the industrial environment Handbook of Raman spectroscopy: from the research laboratory to the process line 2001 New York Marcel-Dekker
- Kourti T Davis B The business benefits of quality by design (QbD) Pharm Eng 2012 32 4 1 10
- Moore CMV Regulatory perspective on real time release testing (RTRT) 2011 Washington DC Proceedings of the AAPS Annual Meeting
- Gervasio GJ Pelletier MJ On-line Raman analysis of PCl3 reactor material J Process Anal Chem 1997 3 1/2 7 11
Cited by
Items 201–300 of 351
Luisetto, M. (2022) · Medicinal & Analytical Chemistry International · doi:10.23880/macij-16000175 · Cited by 5
Li, H., Zhou, Y., Wu, Y., Jiang, Y., Bao, H. F., Peng, A., & Shao, Y. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1218927 · Cited by 5
Food Safety Issues in the Oltrepò Pavese Area: A SERS Sensing Perspective
Albini, B., Galinetto, P., Schiavi, S., & Giulotto, E. (2023) · Sensors · doi:10.3390/s23229015 · Cited by 5
Gravity as a Knob for Tuning Particle Size Distributions of Small Molecules
Pal, K., & Radocea, A. (2024) · Crystal Growth & Design · doi:10.1021/acs.cgd.3c01274 · Cited by 5
Xu, G., O’Shea, N., Drouin, G., Pacheco-Pappenheim, S., O’Donnell, C. P., & Hogan, S. A. (2024) · Food Research International · doi:10.1016/j.foodres.2024.114690 · Cited by 5
Frenkel, K., Opel, C., Walter, R., & Imming, P. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.114918 · Cited by 5
Vaccari, N., Wacogne, B., Koubevi, C., Podevin, M. B., Rouleau, A., & Frelet‐Barrand, A. (2021) · Journal of Translational Science · doi:10.15761/jts.1000465 · Cited by 5
Digitalization platform and supervisory control of an integrated continuous bioprocess
Feidl, F. (2019) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000381363 · Cited by 6
Design and Evaluation of Luliconazole-Loaded NLC Gel for Enhanced Dermatophytosis Therapy
Biswas, U. K., Bose, A., Naskar, S., & Sen, S. (2025) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-025-10225-y · Cited by 4
“Additionally, slight deviations from perfect sphericity in a few particles may be attributed to morphological changes induced during the sample drying [ 58].”
Real‐Time Monitoring of In Vitro Transcription for Production of mRNA Using Raman Spectroscopy
Fulber, J. P. C., Xu, X., Radi, H. E., Grollier, K., & Kamen, A. (2026) · Biotechnology and Bioengineering · doi:10.1002/bit.70196 · Cited by 4
Real-Time Monitoring of Crystallization Processes Using a Novel Compact Composite Sensor Array
Báez, J. P. F., Soto-Bibiloni, A., & Stelzer, T. (2023) · Organic Process Research & Development · doi:10.1021/acs.oprd.3c00330 · Cited by 4
Barman, P., Chakraborty, A., Wu, X., Akimov, D., Meyer‐Zedler, T., Ronning, C., Schmitt, M. P., Popp, J., & Huang, J. (2024) · Laser & Photonics Review · doi:10.1002/lpor.202400805 · Cited by 4
Freeze-drying-induced mutarotation of lactose detected by Raman spectroscopy
Monola, J., Koivunotko, E., Zini, J., Niemelä, A., Koivuniemi, A., Kröger, A., Korhonen, O., Valkonen, S., Merivaara, A., Harjumäki, R., et al. (2024) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2024.114534 · Cited by 4
Chong, M. W. S., Ward, M. R., McFarlan, C., Parrott, A. J., Dallin, P. H., Andrews, J., Oswald, I. D. H., & Nordon, A. (2024) · Chemical Communications · doi:10.1039/d4cc05591h · Cited by 4
Sanchez, C., Radi, H. E., Gay, N., Cailletaud, J., Grollier, K., Thomas, F., & Gonthiez, T. (2025) · Biotechnology Progress · doi:10.1002/btpr.70018 · Cited by 4
Avohou, H. T., Sacré, P., Hubert, P., & Ziémons, E. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04098 · Cited by 4
Sowoidnich, K., Towrie, M., & Matousek, P. (2023) · Applied Spectroscopy · doi:10.1177/00037028231168405 · Cited by 4
“In contrast to the previously mentioned transmission Raman approach, in WAI, the illumination and collection areas are located on the same side of the sample and overlap completely.(38,39) The technique has found applications for the inspection of various specimens including pharmaceutical tablets(40) or suspensions,(…”
BackgroundHalfway to Automated Feeding of Chinese Hamster Ovary Cells
Tomažič, S., & Škrjanc, I. (2023) · Sensors · doi:10.3390/s23146618 · Cited by 4
Wegner, C. H., Eming, S. M., Walla, B., Bischoff, D., Weuster‐Botz, D., & Hubbuch, J. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1397465 · Cited by 5
Beton-Mysur, K., & Brożek-Płuska, B. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126464 · Cited by 4
Pandya, A., Kumaradas, J., & Douplik, A. (2019) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe19.05.010301 · Cited by 4
Low-Content Quantitation in Entecavir Tablets Using 1064 nm Raman Spectroscopy
Kang, Y., Zhou, Y., Wu, Q., Wang, N., & Zhou, J. (2020) · Journal of Spectroscopy · doi:10.1155/2020/1308385 · Cited by 4
Tong, W., Zhou, G., & Waldman, J. H. (2022) · Organic Process Research & Development · doi:10.1021/acs.oprd.1c00446 · Cited by 4
Continuous monitoring of IgG using immobilized fluorescent reporters
Goyal, A., Vu, B., Maranholkar, V., Patil, U., Kourentzi, K., & Willson, R. C. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28254 · Cited by 4
Neel, A. J., Liu, Z., Benkovics, T., Wang, L., Rummelt, S. M., Johnson, H. C., Belyk, K. M., Xu, F., Chung, C. K., Lamberto, D. J., et al. (2023) · Organic Process Research & Development · doi:10.1021/acs.oprd.2c00395 · Cited by 4
Zhao, Y., Tang, Y., Wasalathanthri, D. P., Xu, J., & Ding, J. H. (2023) · Biotechnology Progress · doi:10.1002/btpr.3349 · Cited by 4
Báez, J. P. F., la Rosa, M. V. G. D., Alvarado-Hernández, B. B., Romañach, R. J., & Stelzer, T. (2023) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2023.115451 · Cited by 5
Chemometrics on pharmaceuticals
Maggio, R. M., Vignaduzzo, S. E., & Antonio, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21493-6.00016-2 · Cited by 5
Triglycerides as indicators of erythrocyte hemoglobin oxygen-binding properties1
Fornal, M., Piergies, N., Pięta, E., Wróbel, T. P., Kwiatek, W. M., Paluszkiewicz, C., Królczyk, J., & Grodzicki, T. K. (2018) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-189127 · Cited by 4
“The integral intensity ratio of the 1639 cm – 1 band, which is a known oxygenation marker, and of the ∼ 1551 cm– 1 band, which is related to the deoxygenated state [1, 6, 14] was taken as a measure of the oxygen concentration in red blood cells – this ratio varied from 0.89 to 1.28.”
InfluentialNanomaterials for Drug Delivery
Bal, Y. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-814031-4.00011-8 · Cited by 4
Li, B., & Larkin, P. J. (2020) · Applied Spectroscopy · doi:10.1177/0003702820919823 · Cited by 4
Schini, A., Radi, H. E., Cailletaud, J., Sanchez, C., Gay, N., Ebel, B., Guédon, E., & Jourdainne, L. (2026) · Biotechnology Progress · doi:10.1002/btpr.70111 · Cited by 3
Eddaou, I., Bom, S., Graça, A., & Marto, J. M. (2026) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2026.126750 · Cited by 3
Ramachandran, R., Narayanam, M., Wethman, R. G., Jayaraman, K. S., Dikundwar, A. G., & Bhutani, H. (2022) · Spectroscopy · doi:10.56530/spectroscopy.cd1689c2 · Cited by 3
Kress, J., Nandita, E., Jones, E. B., Sanou, M., Higgins, J. P., & Kosanam, H. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.464281 · Cited by 3
Bērziņš, K., & Boyd, B. J. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c01977 · Cited by 3
Seeing beyond Labels: Optical Technologies Reshaping Cell Culture Monitoring in Biomedicine
Charconnet, M., & Plou, J. (2024) · ACS Applied Engineering Materials · doi:10.1021/acsaenm.4c00613 · Cited by 3
Quantitative Perspective on Online Flow Reaction Profiling Using a Miniature Mass Spectrometer
Sheng, H., Corcoran, E. B., Dance, Z. E. X., Smith, J. P., Lin, Z., Ordsmith, V., Hamilton, S. E., & Zhuang, P. (2020) · Organic Process Research & Development · doi:10.1021/acs.oprd.0c00294 · Cited by 3
Industrial Monitoring of Cell Culture
Schwamb, S., Engel, M., Werner, T., & Wiedemann, P. (2021) · Cell engineering · doi:10.1007/978-3-030-79871-0_17 · Cited by 3
Isidro, I. A., Pais, D. A. M., Alves, P. M., & Carrondo, M. J. T. (2019) · Elsevier eBooks · doi:10.1016/b978-0-444-64046-8.00112-9 · Cited by 3
Opoku-Ansah, J., Yahaya, E. S., Amuah, C. L. Y., Nyorkeh, R., Adom‐Konadu, A., Adueming, P. O., & Teye, E. (2022) · Analytical Methods · doi:10.1039/d2ay00541g · Cited by 3
Fontalvo-Lascano, M. A., Alvarado-Hernández, B. B., Conde, C. A. N., Sánchez, E. J., Méndez-Piñero, M. I., & Romañach, R. J. (2022) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-022-09634-0 · Cited by 3
“The continuous and frequent blend evaluation through the stream sampler/PAT system facilitates taking real‐time corrective actions, contributing to prevention and risk management throughout the product manufacturing lifecycle [36, 37].”
BackgroundКупцов, А. Х., Zhmaeva, E. V., Kulik, A. V., & Rudyak, K. B. (2022) · Chemistry and Technology of Fuels and Oils · doi:10.1007/s10553-022-01449-6 · Cited by 3
Raman Spectroscopy: A Key Analytical Tool for New Drugs Research and Development
Pînzaru, S. C., Fălămaș, A., & Dehelean, C. A. (2018) · Studies in natural products chemistry · doi:10.1016/b978-0-444-64183-0.00006-3 · Cited by 3
New Conceptional Study of a Portable Highly Sensitive Photometric Raman Sensor
Manser, S., Kommert, S., Keck, S. P., Spoor, E., & Rädle, M. (2022) · Sensors · doi:10.3390/s22166098 · Cited by 3
“By selecting suitable peaks specific to the reaction, an adaptable process monitoring function is created [3].”
BackgroundYu, N., Zhang, L., Zhang, X., Hu, C., & Chen, C. Q. (2023) · Photonics · doi:10.3390/photonics10050574 · Cited by 2
Development of a Raman Model for Continuous Monitoring of Detergent Viral Inactivation
Denny, K., Znidarsic, M., Hamedi, H., Stanley, B., & Khattak, S. F. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70087 · Cited by 2
Dzurendová, S., Losada, C. B., Dupuy-Galet, B. X., Slaný, O., Fjær, K., Bartolomeo, F. D., Markussen, S., Wentzel, A., Várnai, A., Hansen, L. D., et al. (2025) · Microbial Cell Factories · doi:10.1186/s12934-025-02868-w · Cited by 2
“Moreover, both methods offer versatile measurement setups, from in-situ monitoring in bioreactors by fibre-optic probes [25, 33–36], high-throughput at-line screening [2, 24, 37], to the detailed cellular imaging by microspectroscopies [38, 39].”
Zhang, Q., Tang, Y., Nie, H., Wang, X., Wang, G., & Xiao, C. (2025) · PharmaNutrition · doi:10.1016/j.phanu.2025.100470 · Cited by 2
Palem, C. R., & Lekkala, V. K. (2026) · Journal of Pharmacy · doi:10.31436/jop.v6i1.373 · Cited by 2
Learning from limited data and feedback for cell culture process monitoring: A comparative study
peng, J., Khuat, T. T., Otte, E. A., Musial, K., & Gabryś, B. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.175264 · Cited by 4
Albu, P. (2026) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-026-16067-1 · Cited by 2
“…risk-based rather than prescriptive of specific instrumentation, but in practice the dominant in-line analytical technologies have been NIR and Raman spectroscopy [71], with high-throughput chemometric models translating spectroscopic readouts into critical-quality-attribute estimates in real time.”
Torres, A. J. (2023) · Biotechnology Journal · doi:10.1002/biot.202300271 · Cited by 2
Zhao, Y., Trearchis, P., Shandil, I., Wasalathanthri, D. P., Li, G., & Leone, A. M. (2024) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-024-09866-2 · Cited by 2
Spiske, F., Jakob, L. S., Lippold, M., Rahimi, P., Joseph, Y., & Braeuer, A. (2024) · Sensors · doi:10.3390/s24185979 · Cited by 2
Yao, J., Zhao, X., Wang, J., Cheng, M., Jiang, Y., Lian, X., Zhao, T., & Shan, G. (2024) · Current Pharmaceutical Analysis · doi:10.2174/0115734129335776240920063832 · Cited by 2
Wacogne, B., Brito, M., Gamonet, C., Rouleau, A., & Frelet‐Barrand, A. (2025) · Biosensors · doi:10.3390/bios15040251 · Cited by 2
“Spectroscopic techniques [20], including Raman spectroscopy, have been used for cell characterization and identification, either directly in situ [21] or with surface-enhanced Raman scattering [22–24].”
Quantification of drug contents in molded tablets via transmission low-frequency Raman spectroscopy
Inoue, M., Akiyama, T., & Fukami, T. (2025) · The Analyst · doi:10.1039/d5an00079c · Cited by 2
Athalye, S. M., Maruthamuthu, M. K., Esmaili, E., Boodaghidizaji, M., Sarathy, N., Mayorga, C., Raffaele, J., Selvamani, V., Smith, J. P., Matos, T., et al. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126761 · Cited by 3
Optimizing laser crater enhanced Raman scattering spectroscopy
Lednev, V. N., Sdvizhenskii, P. A., Grishin, M. Y., Fedorov, A. N., Khokhlova, O. V., Oshurko, V. B., & Першин, С. М. (2018) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2018.01.070 · Cited by 2
Optimizing laser crater enhanced Raman spectroscopy
Lednev, V. N., Sdvizhenskii, P. A., Grishin, M. Y., Filichkina, V. A., Shchegolikhin, A. N., & Першин, С. М. (2018) · Applied Optics · doi:10.1364/ao.57.002096 · Cited by 2
Regulatory Aspects for Formulation Design – with Focus on the Solid State
Gruss, M. (2019) · Methods and principles in medicinal chemistry · doi:10.1002/9783527812172.ch5 · Cited by 2
REACTION KINETICS AND CHARACTERIZATION
Singh, U. K., Reizman, B. J., Changi, S. M., Burt, J. L., & Orella, C. (2019) · Wiley eBooks · doi:10.1002/9781119600800.ch8 · Cited by 2
Rangan, S., Schulze, H. G., Vardaki, M. Z., Blades, M. W., Piret, J. M., & Turner, R. F. B. (2020) · The Analyst · doi:10.1039/d0an90028a · Cited by 2
Traylor, M. J., Bernhardt, P., Tangarone, B. S., & Varghese, J. (2018) · Biopharmaceutical Processing · doi:10.1016/b978-0-08-100623-8.00047-5 · Cited by 1
Johnson, K., & Kühn, M. (2024) · Pharmaceutical Statistics · doi:10.1002/pst.2366 · Cited by 3
“Spectroscopy data has traditionally been modeled using PLS. 28,29 PLS is a logical technique to use for this type of data because it naturally handles highly correlated predictors.”
Triplet Network for One-Shot Raman Spectrum Recognition
Wang, B., Zhang, P., Zhao, W. G., Ren, W., Zhu, X., Jiao, Y., Liao, Q., & Yao, Z. (2024) · Applied Spectroscopy · doi:10.1177/00037028241297180 · Cited by 1
“5 However, identifying Raman spectroscopy data remains a challenging problem.”
Chemical sensing as a utility using parallel, distributed swept source Raman spectroscopy
Persits, N., Dry, D. L., Kim, J., Bozinovski, D. M., Mohan, N., Nieves, M. J., Wolfrum, J. M., Barone, P. W., Springs, S. L., Sinskey, A. J., et al. (2025) · Optics Express · doi:10.1364/oe.559283 · Cited by 1
Workman, J. (2025) · Spectroscopy · doi:10.56530/spectroscopy.pl1982h4 · Cited by 1
Gaining Quantitative Fidelity from Raman Spectra in Regimes of Large and Varying Fluorescence
Zarei, M., Rothwell, A., Melo, L., Shokatian, S., & Grant, E. R. (2025) · Applied Spectroscopy Practica · doi:10.1177/27551857251404926 · Cited by 1
Kashif, M., Keating, M. E., & Byrne, H. J. (2026) · The Analyst · doi:10.1039/d5an01055a · Cited by 2
Temperature-induced spectral anomalies in doxorubicin—A Raman study
Todorović, E., Orzechowska, S., Milovanović, M., Pešić, J., Barańśka, M., Lazarević, J., & Lazarević, N. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.127678 · Cited by 1
Raman-guided sample subset selection for cost-efficient offline calibration in bioprocesses
Wilms, T., Schwenke, F., King, R., & Knorn, S. (2026) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-026-03402-x · Cited by 1
“Spectroscopy has traditionally been applied in biotechnology and pharmaceutical manufacturing as a PAT for predicting immeasurable process variables [29–31].”
Han, S.-H., Park, J., Kwang-Bae, L., Park, C.-H., & Lee, D.-Y. (2026) · Bioresources and Bioprocessing · doi:10.1186/s40643-026-01105-5 · Cited by 1
Liu, S., Yu, J., Huang, D., Wu, Y., Yang, Y., Lu, W., Long, J., Wang, L., Ruan, Y., Wang, Z., et al. (2026) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-026-06514-1 · Cited by 1
“…studies, one can prepare glucose model solutions of known concentration for Raman measurements and establish calibration datasets for PLS analysis [63], and the Raman spectra of glucose acquired offline are used to develop the PLS model to minimize interference from feeding and sampling methods…”
Ecology-microbiome engineering in Sauce-flavor Baijiu via Single-Cell Raman Spectroscopy
Sun, X., Yi, X., & Zhang, J. (2026) · BioDesign Research · doi:10.1016/j.bidere.2026.100089 · Cited by 1
“It is imperative that at-line SCRS modules exhibit robust interfacing capabilities with existing Process Analytical Technology frameworks [93].”
Kim, Y., & Lee, W. (2026) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2026.105772 · Cited by 1
Barazandegan, Y., Kc, D., Iha, R., Tu, N., Ryan, N., Martano, P., Jones, X., Yang, J., Mu, R., & Yang, Q. (2026) · Micromachines · doi:10.3390/mi17060725 · Cited by 1
“Raman spectrometers add further expense due to fabrication and intensive data processing needs [223,224].”
Zhu, Y., Lou, D., Yang, C., Ding, R., Song, M., Wang, R. G., Lu, Y., & Fan, Q. (2026) · Biotechnology and Bioengineering · doi:10.1002/bit.70274 · Cited by 1
Gaikwad, A. S., Pawar, S. B., Jori, D. K., & Gaikwad, H. K. (2026) · Discover Applied Sciences · doi:10.1007/s42452-026-09075-1 · Cited by 1
Turac, I.-R., Casian, T., Iurian, S., Porfire, A. S., Iovanov, R., Popa, D. E., & Tomuță, I. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18080935 · Cited by 1
“It can be easily implemented on-line and in-line into the monitoring of CQAs of dosage forms, but also for the QC of the intermediate product [122,140].”
Nieuwoudt, M. K., Holroyd, S. E., McGoverin, C., Simpson, M. C., & Williams, D. E. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253147 · Cited by 1
An Introduction to Infra‐red and R aman Spectroscopies for Pharmaceutical and Biomedical Studies
Chan, K. L. A. (2019) · Wiley eBooks · doi:10.1002/9781119483977.ch13 · Cited by 2
Perfusion Mammalian Cell Culture for Recombinant Protein Manufacturing
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209.001 · Cited by 2
Design and Optimisation of Mammalian Cell Perfusion Cultures
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209.004 · Cited by 1
Scale-Down Models and Sensors for Process Development
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209.003 · Cited by 2
Chemometric methods in pharmaceutical technology
Djuriš, J., Kurćubić, I., Ibric, S. R., & Đurić, Z. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18655-4.00006-6 · Cited by 2
Qualitative Analysis of Different Formulations of Losartan Potassium Using Raman Spectroscopy
Heinzelmann, T. R. D. O., de Lima, C. J., Carvalho, H. C., Fernandes, A. B., & Silveira, L. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49410-9_29 · Cited by 1
Yao, J., Zhao, X., Wang, J., Cheng, M., Jiang, Y., Lian, X., Zhao, T., & Shan, G. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4477738 · Cited by 1
Liu, Y., Wu, X., & Jiang, H. (2019) · Reproduction Fertility and Development · doi:10.1071/rd18360
Development of advanced monitoring and control tools for rAAV production in the insect cell system
Pais, D. A. M. (2020) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Modern Instrumental Methods in Solid Dosage Form Analysis
Bartoníčková, E., Brus, J., Gajdziok, J., Franc, A., Hickey, K., Kejdušová, M., Mašek, J., Pavloková, S., Šeděnková, I., & Vetchý, D. (2021) · doi:10.5817/cz.muni.m210-9724-2021
Perfusion Bioreactors:The Set-Up and Process Characterisation
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209.002
2027 A local buckling models for box columns with constant strain triangular elements
桑原, 進., & 澤井, 祥. (1994) · 日本建築学会近畿支部研究報告集. 構造系
Clinical- and Commercial-Scale Reactors
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209.005
Mechanistic and Statistical Modelling of Bioprocesses
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209.006
Manufacturing Human Pluripotent Stem Cells and Differentiated Progenitors
Vassilev, S., & Oh, S. K. W. (2021) · Cell engineering · doi:10.1007/978-3-030-79871-0_8 · Cited by 1
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209.007
Control Strategies of Solid Dosage Forms by PAT Tools
Sacré, P., Bleye, C. D., Hubert, P., & Ziémons, E. (2023) · AAPS introductions in the pharmaceutical sciences · doi:10.1007/978-3-031-31505-3_7
Ouyang, Q., Xi, Q., Rong, Y., Ahmad, W., & Chen, Q. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4596725
Metadata
- Authors
- Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2016-08-04
- Volume
- 409
- Issue
- 3
- Pages
- 637-649
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- PMC
- PMC5233728
- OpenAlex
- W2497039129
- Cited by
- 332
- References
- 103
- Citations by year
- 2026: 43 · 2025: 36 · 2024: 42 · 2023: 31 · 2022: 35 · 2021: 36 · 2020: 50 · 2019: 26 · 2018: 23 · 2017: 8 · 2016: 1
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR007080)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- Raman spectroscopy, process analytical technology, pharmaceutical manufacturing, bioprocessing, quality by design, continuous production, real-time release testing, statistical process control, in situ monitoring
- MeSH terms
- Biotechnology, Spectrum Analysis, Raman, Technology, Pharmaceutical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.