Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bioprocessing
Open accessThe DOI matches its Crossref record; 102 of the 103 references it cites were found in a registry or an index.
Abstract
Adoption of Quality by Design (QbD) principles, regulatory support of QbD, process analytical technology (PAT), and continuous manufacturing are major factors effecting new approaches to pharmaceutical manufacturing and bioprocessing. In this review, we highlight new technology developments, data analysis models, and applications of Raman spectroscopy, which have expanded the scope of Raman spectroscopy as a process analytical technology. Emerging technologies such as transmission and enhanced reflection Raman, and new approaches to using available technologies, expand the scope of Raman spectroscopy in pharmaceutical manufacturing, and now Raman spectroscopy is successfully integrated into real-time release testing, continuous manufacturing, and statistical process control. Since the last major review of Raman as a pharmaceutical PAT in 2010, many new Raman applications in bioprocessing have emerged. Exciting reports of in situ Raman spectroscopy in bioprocesses complement a growing scientific field of biological and biomedical Raman spectroscopy. Raman spectroscopy has made a positive impact as a process analytical and control tool for pharmaceutical manufacturing and bioprocessing, with demonstrated scientific and financial benefits throughout a product's lifecycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Schematic comparing variants of sample excitation (solid line) and signal collection [dashed line(s)] used in Raman spectroscopy in measuring turbid media. (a) Backscattered Raman is a commonly used geometry that uses a single site of excitation with collection of signal close (<1 mm) to the excitation. As applied to Raman microscopy, this approach is called epi-illumination as a single microscope objective is used to excite the sample and collect Raman signal. The sampling volume in backscattered Raman is generally small, both in the lateral and axial dimensions. Thus, backscattered Raman is a good approach for measuring a surface. (b) Overlapping a defocused or wide laser beam with multiple collection fibers in a backscattering-like geometry is called wide area Raman (also known as large volumetric or global illumination Raman). (c) Separating collection fibers from the sample excitation by a small distance (Δd = 1–6 mm) enables collection of diffusely scattered Raman photons, known as a spatially-offset Raman spectroscopy (SORS). (d) Transmission Raman collects Raman photons diffusely scattered through a sample. Wide area, spatially-offset Raman spectroscopy (SORS) and transmission Raman provides representative sampling in turbid media and enables collection of Raman signal from buried layers in a layered sample](https://figures.cochat.ai/paper-figures/e5a0bbbc329941ad87050f571a218a65/raman-spectroscopy-as-a-process-analytical-technology-for-pharmaceutical-figure-1.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the monitoring of intracellular and extracellular macromolecules in bioprocesses share many intrinsic similarities to yeast and bacteria bioprocesses, which have been extensively reviewed together due to these similarities [20,21,29].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [29]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Since our critical review of Raman spectroscopy in pharmaceutical manufacturing and bioprocessing in 2016 [18], we have seen developments in the use of Raman variants or enhancement strategies in basic science applications, expansion of in situ Raman measurements in upstream bioprocessing, and increasing compatibility of process Raman with process automation.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
The cited source says what the claim attributes to it.
In the citing paper
“Variations in the geometry of optical fibers and lenses within the probe can enable a variety of sampling options including backscattered, large volumetric, spatially offset Raman, and transmission Raman.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
In the citing paper
“These include the need for large and representative datasets, optimal preprocessing techniques, handling environmental and noise sensitivities, high initial costs, and ensuring regulatory compliance [67].”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [67]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Production of recombinant protein therapeutics in cultivated mammalian cells
Wurm, F. M. (2004) · Nature Biotechnology · doi:10.1038/nbt1026 · Cited by 2,032 · cited 1×
“Production of protein therapeutics by mammalian cells is the most widely used bioprocess because of its ability to properly produce and fold a recombinant protein, with 60–70 % of biopharmaceuticals using this bioprocess [79, 80].”
BackgroundReference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 1×
“There are excellent reviews providing Raman spectra of biomolecules, complete with tables of band assignments [66, 67].”
BackgroundTissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352 · cited 1×
“Most cell and tissue spectroscopy is performed in the Btherapeutic^ near-infrared window (650– 1350 nm) because optical scattering is dominant and water absorption is at a minimum [14, 15].”
BackgroundBabuška, R. (1998) · International Series in Intelligent Technologies · doi:10.1007/978-94-011-4868-9 · Cited by 1,318
Biological Applications of Raman Spectroscopy
(2000) · Infrared and Raman Spectroscopy of Biological Materials · doi:10.1201/b16936-17 · Cited by 1,088
Sturgeon, R. (1988) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/0584-8547(88)80189-7 · Cited by 979
Vo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681 · cited 1×
“API or excipient particles and cellular organelles, such as mitochondria and nuclei, also strongly scatter light [16, 17].”
BackgroundMascia, S., Heider, P. L., Zhang, H., Lakerveld, R., Benyahia, B., Barton, P. I., Braatz, R. D., Cooney, C. L., Evans, J. M. B., Jamison, T. F., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305429 · Cited by 599
De Beer, T., Burggraeve, A., Fonteyne, M., Saerens, L., Remon, J. P., & Vervaet, C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.012 · Cited by 559
Research works printed but not linked: 4
- Slater JB Tedesco TM Fairchild RC Lewis IR Lewis IR Edwards HGM Raman spectrometry and its adaptation to the industrial environment Handbook of Raman spectroscopy: from the research laboratory to the process line 2001 New York Marcel-Dekker
- Kourti T Davis B The business benefits of quality by design (QbD) Pharm Eng 2012 32 4 1 10
- Moore CMV Regulatory perspective on real time release testing (RTRT) 2011 Washington DC Proceedings of the AAPS Annual Meeting
- Gervasio GJ Pelletier MJ On-line Raman analysis of PCl3 reactor material J Process Anal Chem 1997 3 1/2 7 11
Cited by
Items 101–200 of 351
Non-invasive Raman spectroscopy for time-resolved in-line lipidomics
Wieland, K., Masri, M. A., von Poschinger, J., Brück, T., & Haisch, C. (2021) · RSC Advances · doi:10.1039/d1ra04254h · Cited by 20
Advances and opportunities in process analytical technologies for viral vector manufacturing
Sripada, S. A., Hosseini, M., Ramesh, S., Wang, J., Ritola, K., Menegatti, S., & Daniele, M. A.-A. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108391 · Cited by 19
Kwon, T., Ko, S. H., Hamel, J. P., & Han, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05835 · Cited by 19
In situ real time monitoring of emulsification and homogenization processes for vaccine adjuvants
Ralbovsky, N. M., Soukup, R. J., Lomont, J. P., Lauro, M. L., Gulasarian, A., Saha-Shah, A., Winters, M. A., Richardson, D. D., Wang, S.-C., Mangion, I. K., et al. (2021) · The Analyst · doi:10.1039/d1an01797g · Cited by 19
Pharmaceutical quantification with univariate analysis using transmission Raman spectroscopy
Shimamura, R., Koide, T., Hisada, H., Inoue, M., Fukami, T., Katori, N., & Goda, Y. (2019) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2019.1621336 · Cited by 18
“Quantitative results in simple formulation model tablets using transmission Raman spectroscopy were compared with those of other measurement modes, including backscattering micro-spectroscopy and wide area Raman [14,15] under the same conditions.”
ResultXiouras, C., Belletti, G., Venkatramanan, R., Nordon, A., Meekes, H., Vlieg, E., Stefanidis, G. D., & ter Horst, J. H. (2019) · Crystal Growth & Design · doi:10.1021/acs.cgd.9b00867 · Cited by 18
A Reliable Automated Sampling System for On-Line and Real-Time Monitoring of CHO Cultures
Hofer, A., Kröll, P., Barmettler, M., & Herwig, C. (2020) · Processes · doi:10.3390/pr8060637 · Cited by 18
“There are a few scientific contributions available dealing with automated sampling for on-line HPLC [5,6,15–18].”
BackgroundYang, N., Guerin, C., Kokanyan, N., & Perré, P. (2024) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2024.10.007 · Cited by 18
Deep Learning-Powered Colloidal Digital SERS for Precise Monitoring of Cell Culture Media
Zheng, P., Wu, L., Lee, M. K. H., Nelson, A., Betenbaugh, M. J., & Barman, I. (2025) · Nano Letters · doi:10.1021/acs.nanolett.5c01071 · Cited by 16
Method of Monitoring the Number of Amide Bonds in Peptides Using Near-Infrared Spectroscopy
Ishigaki, M., Ito, A. M., Hara, R., Miyazaki, S.-I., Murayama, K., Yoshikiyo, K., Yamamoto, T., & Ozaki, Y. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03424 · Cited by 18
Low-power swept-source Raman spectroscopy
Atabaki, A. H., Herrington, W. F., Burgner, C., Jayaraman, V., & Ram, R. J. (2021) · Optics Express · doi:10.1364/oe.427105 · Cited by 16
Non-invasive monitoring of the growth of metal–organic frameworks (MOFs) via Raman spectroscopy
Chong, M. W. S., Parrott, A. J., Ashworth, D. J., Fletcher, A. J., & Nordon, A. (2023) · Physical Chemistry Chemical Physics · doi:10.1039/d3cp01004j · Cited by 16
Duraipandian, S., Knopp, M. M., Pollard, M. R., Kerdoncuff, H., Petersen, J. C., & Müllertz, A. (2018) · Analytical Methods · doi:10.1039/c8ay00753e · Cited by 16
Assessment of Bulk Composition of Heterogeneous Food Matrices Using Raman Spectroscopy
Andersen, P. V., Wold, J. P., & Afseth, N. K. (2021) · Applied Spectroscopy · doi:10.1177/00037028211006150 · Cited by 16
Open-source Raman spectra of chemical compounds for active pharmaceutical ingredient development
Flanagan, A. R., & Glavin, F. G. (2025) · Scientific Data · doi:10.1038/s41597-025-04848-6 · Cited by 19
Cortada‐Garcia, J., Haggarty, J. H., Weidt, S. K., Daly, R., Arnold, S. A., & Burgess, K. E. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28599 · Cited by 16
“…conditions that they are developed with, such as the organism, medium composition, pH or stirring speed used in the process with model transferability being a known challenge in industry and reported in the literature (Esmonde ‐ White et al., 2017; Roggo et al., 2007; Roychoudhury et al., 2007).”
BackgroundMa, H., Guo, J., Liu, G., Xie, D., Zhang, B., Li, X., Zhang, Q., Cao, Q., Li, X., Ma, F., et al. (2024) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2024.2329956 · Cited by 16
Wieser, W., Assaf, A., Gouic, B. L., Dechandol, E., Herve, L., Louineau, T., Dib, O. H., Gonçalves, O., Titica, M., Couzinet‐Mossion, A., et al. (2023) · Sensors · doi:10.3390/s23249746 · Cited by 15
“Among the available methods, Raman spectroscopy is a promising technology offering rapid, non-invasive and non-destructive measurement of living cells [12].”
MethodPerfusion Cell Culture Processes for Biopharmaceuticals: Process Development, Design, and Scale-up
Wolf, M., Bielser, J., & Morbidelli, M. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108847209 · Cited by 18
Robust platform for inline Raman monitoring and control of perfusion cell culture
Wan, B., Patel, M., Zhou, G., Olma, M. H., Bieri, M., Mueller, M., Appiah‐Amponsah, E., Patel, B. A., & Jayapal, K. P. (2024) · Biotechnology and Bioengineering · doi:10.1002/bit.28680 · Cited by 15
“There are numerous reports on successful application of Raman spectroscopy for various online, inline, or at ‐ line analysis (Esmonde ‐ White et al., 2017; Jesus et al., 2020).”
BackgroundSimulation and quantitative analysis of Raman spectra in chemical processes with autoencoders
Wu, M., Caprio, U. D., Ha, O. V. D., Metten, B., Clercq, D. D., Elmaz, F., Mercelis, S., Hellinckx, P., Braeken, L., Vermeire, F. H., et al. (2024) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2024.105119 · Cited by 15
BioSamplr: An open source, low cost automated sampling system for bioreactors
Efromson, J. P., Li, S., & Lynch, M. (2021) · HardwareX · doi:10.1016/j.ohx.2021.e00177 · Cited by 14
“While advanced sensors, such as those based on raman spectroscopy, may be able to monitor metabolite and product levels in realtime [22,23], sampling is still the gold standard used to measure analytes in fermentation broth.”
BackgroundHarris, S. A., Patel, B. A., Gospodarek, A., Desai, J., de Janon Gutiérrez, A., Botonjic‐Sehic, E., Brower, M., & Pinto, N. D. S. (2021) · Biotechnology Progress · doi:10.1002/btpr.3187 · Cited by 14
“In recent years biotechnology companies have been addressing the implementation of process analytical technology (PAT) and chemometrics in biomanufacturing.(1,2,3) Advanced technologies utilizing probes and sensors capable of real-time monitoring and analysis have contributed significantly toward implementation of PAT…”
BackgroundRaman spectroscopy-based identification of toxoid vaccine products
Silge, A., Bocklitz, T. W., Becker, B., Matheis, W., Popp, J., & Bekeredjian‐Ding, I. (2018) · npj Vaccines · doi:10.1038/s41541-018-0088-y · Cited by 14
Koide, T., Takeuchi, Y., Otaki, T., Yamamoto, K., Shimamura, R., Ohashi, R., Inoue, M., Fukami, T., & Izutsu, K. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.112886 · Cited by 14
Jin, H., Lin, T., Han, P., Yao, Y., Zheng, D., Hao, J., Hu, Y., & Zeng, R. (2019) · Medicine · doi:10.1097/md.0000000000018066 · Cited by 14
Illuminating the Tiny World: A Navigation Guide for Proper Raman Studies on Microorganisms
Frempong, S. B., Salbreiter, M., Mostafapour, S., Pistiki, A. C., Bocklitz, T. W., Rösch, P., & Popp, J. (2024) · Molecules · doi:10.3390/molecules29051077 · Cited by 13
Karnachoriti, M., Chatzipetrou, M., Touloupakis, E., Kontos, A. G., & Zergioti, I. (2025) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6841 · Cited by 14
Pipeline for the removal of hardware related artifacts and background noise for Raman spectroscopy
Bertens, C. J. F., Zhang, S., Erckens, R. J., van den Biggelaar, F. J. H. M., Berendschot, T. T. J. M., Webers, C. A. B., Nuijts, R. M. M. A., & Gijs, M. (2020) · MethodsX · doi:10.1016/j.mex.2020.100883 · Cited by 13
Automation in synthetic biology using biological foundries
Tang, T., Fu, L., Guo, E., Zhang, Z., Wang, Z., Ma, C., Zhang, Z., Zhang, J., Huang, J., & Si, T. (2020) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2020-0498 · Cited by 14
“例如 , 高内涵成像筛选与高通量合成生物改造的结 合 , 可以为系统性理解复杂生命过程提供新的研究手 段 [35] ; 而在线光学探针在发酵过程的参数控制和优化 方面发挥着越来越重要的作用 [36] .”
Integrating sensors for monitoring blend content in a pharmaceutical continuous manufacturing plant
Panikar, S. S., Li, J., Rane, V., Gillam, S., Callegari, G., Kurtyka, B., Lee, S., & Muzzio, F. J. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.120085 · Cited by 13
Ando, D., Miyazaki, T., Yamamoto, E., Koide, T., & Izutsu, K. (2021) · Drug Delivery and Translational Research · doi:10.1007/s13346-021-01052-y · Cited by 13
“In addition, 1 obtaining the Raman spectra at each position of the formulation provides information on the spatial 2 distribution of components, as well as their physical states, which are valuable for troubleshooting 3 manufacturing processes [22] , monitoring blend homogeneity [23], revealing the internal structure…”
BackgroundDynamic Modeling and Plantwide Control of a Production Process for Biodiesel and Glycerol
Wajeh, M. E., Mhamdi, A., & Mitsos, A. (2023) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.3c00934 · Cited by 13
Continuous multi-membrane chromatography of large viral particles
Matos, T., Hoying, D., Kristopeit, A., Wenger, M. D., & Joyce, J. G. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.464194 · Cited by 14
Fibre-Optic Surface Plasmon Resonance Biosensor for Monoclonal Antibody Titer Quantification
Ly, T. T., Ruan, Y., Du, B., Jia, P., & Zhang, H. (2021) · Biosensors · doi:10.3390/bios11100383 · Cited by 13
“many impurities, including host cell proteins, DNA/RNA, metabolites and Mab variants, which can be very challenging [42].”
BackgroundMethodFarías-Álvarez, L. J., Gschaedler, A., Sánchez-Ortiz, A. F., Femat, R., Cervantes-Martínez, J., Arellano‐Plaza, M., Pedraza, C. Z., Amillastre, E., Ghommidh, C., & Herrera-López, E. J. (2018) · Biochemical Engineering Journal · doi:10.1016/j.bej.2018.04.016 · Cited by 14
Raman spectra comparison: cautions and pitfalls of similarity metrics
Mostafapour, S., Mokari, A., Guo, S., Popp, J., & Bocklitz, T. W. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126702 · Cited by 15
Ji, X., Lee, Y. J., Eyster, T., Parrillo, A. J., Galosy, S. S., Ao, Z., Patel, P., & Zhu, Y. (2021) · Biotechnology Progress · doi:10.1002/btpr.3211 · Cited by 16
“Some examples of these PAT tools include near infrared (NIR) and Raman spectroscopy for detection of media components and metabolic end products.(4,5) However, cell culture control in a Received: 18 February 2021 Revised: 2 September 2021 Accepted: 12 September 2021”
MethodQin, Y., Mattern, K. A., Zhang, V., Abe, K., Kim, J., Zheng, M., Gangam, R., Kalinin, A. V., Kolev, J. N., Axnanda, S., et al. (2024) · Organic Process Research & Development · doi:10.1021/acs.oprd.3c00419 · Cited by 13
Medl, M., Leisch, F., Dürauer, A., & Scharl, T. (2024) · Biotechnology Journal · doi:10.1002/biot.202300554 · Cited by 13
Continuous Fc detection for protein A capture process control
Patil, U., Crum, M., Vu, B. V., Wasden, K., Kourentzi, K. D., & Willson, R. C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112327 · Cited by 12
Jiang, T., Kwofie, F., Attanasio, N., Haas, M., Higgins, J. D., & Kosanam, H. (2024) · The AAPS Journal · doi:10.1208/s12248-024-00973-z · Cited by 13
“This data mining effort enabled us to further assess the correlation between these orthogonal meth-ods by providing prediction of charge variants with mass spectrometry data via the partial least squares regression (PLSR) models in MVDA (41–44).”
Jong, C. Y., Tristan, G., Felix, L. J. J., Yeap, E. W. Q., Dubbaka, S. R., Rao, H. N., & Wong, S. Y. (2025) · Organic Process Research & Development · doi:10.1021/acs.oprd.4c00496 · Cited by 11
Comparing machine learning methods on Raman spectra from eight different spectrometers
Lange, C., Borisyak, M., Kögler, M., Born, S., Ziehe, A., Neubauer, P. B., & Bournazou, M. N. C. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.125861 · Cited by 11
Franca, R. D. G., Carvalho, V. C. F., Fradinho, J. C., Reis, M. A. M., & Lourenço, N. D. (2021) · Applied Sciences · doi:10.3390/app11146600 · Cited by 12
“clude nitrate and nitrite monitoring in a wastewater treatment bioreactor [18], the real-time prediction of glucose concentration during microalgae cultivation in a photo-bioreactor [19] and during mammalian cell cultivations [20], as well as the monitoring substrates and products during bacterial and yeast fermentati…”
BackgroundReview of the Application of PAT in the Pharmaceutical Continuous Crystallization Process
Zhao, B., Zang, H., Zhong, L., Ma, X., Wang, H., Zhang, H., & Li, L. (2023) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026623666230420112709 · Cited by 11
Zühlke, M., Saß, S., Riebe, D., Beitz, T., & Löhmannsröben, H. (2017) · ChemPlusChem · doi:10.1002/cplu.201700296 · Cited by 11
Hara, R., Kobayashi, W., Yamanaka, H., Murayama, K., Shimoda, S., & Ozaki, Y. (2023) · Applied Spectroscopy · doi:10.1177/00037028231160197 · Cited by 12
Chen, W., Park, S. J., Cheng, T. N. H., Lau, N. W. H., Khaw, L. F., Lee‐Lane, D., Chen, X., & Şeşen, M. (2022) · Wiley eBooks · doi:10.1002/9781119695868.ch12 · Cited by 11
Salzillo, T., Marchetti, A., Vejpravová, J., Fanjul‐Bolado, P., & Fontanesi, C. (2022) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2022.101072 · Cited by 11
Continuous manufacturing in pharmaceuticals: an integrated approach with NIR and Raman as PAT tools
Bhimrao, L. S., Kumar, S., Agrawal, A. K., Beer, T. D., Kumar, A., & Kumar, D. K. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.126478 · Cited by 16
Model predictive control in fermentation process – A review
Chai, W. Y., Teo, K. T. K., Tan, M. K., & Tham, H. J. (2022) · AIP conference proceedings · doi:10.1063/5.0101066 · Cited by 10
Udugama, I. A., Badr, S., Hirono, K., Scholz, B. X., Hayashi, Y., Kino‐oka, M., & Sugiyama, H. (2023) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2023.108144 · Cited by 11
Giving the cells what they need when they need it: Biosensor‐based feeding control
Kinet, R., Richelle, A., Colle, M., Demaegd, D., von Stosch, M., Sanders, M., Sehrt, H., Delvigne, F., & Goffin, P. (2024) · Biotechnology and Bioengineering · doi:10.1002/bit.28657 · Cited by 10
Bespoke cell therapy manufacturing platforms
Levinson, Y., Beri, R. G., Holderness, K., Ben‐Nun, I. F., Shi, Y., & Abraham, E. (2018) · Biochemical Engineering Journal · doi:10.1016/j.bej.2018.01.023 · Cited by 10
Helešicová, T., Pekárek, T., & Matějka, P. (2018) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2018.08.002 · Cited by 12
Raman spectroscopy and mapping technique for the identification of expired drugs
Zhang, S., Chen, H., Li, R., Yu, Z., & Lu, F. L. (2019) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.117407 · Cited by 10
Medendorp, J., Shapally, S., Vrieze, D. C., & Tolton, K. (2020) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-020-09498-2 · Cited by 10
Du, Y., Xue, J., & Hong, Z. (2020) · Current Pharmaceutical Design · doi:10.2174/1381612826666200523173448 · Cited by 10
Quantitative Determination of Vitamins A and E in Ointments Using Raman Spectroscopy
Mazurek, S., Pichlak, K., & Szostak, R. (2020) · Processes · doi:10.3390/pr9010008 · Cited by 10
“In the case of industrial application , this method can be adopt d to monitor v rious stages of the production process, starting from raw material and semi-products analysis through the sup rvision of production steps and the analysis of the final products [5,6].”
MethodChen, B., & Qiu, X. (2026) · Analytical Methods · doi:10.1039/d6ay00224b · Cited by 10
Kumar, S., Nagy, Z. K., Reklaitis, G. V., & Gonzalez, M. (2023) · Journal of Spectroscopy · doi:10.1155/2023/8631288 · Cited by 10
Måge, I., Wubshet, S. G., Wold, J. P., Solberg, L. E., Böcker, U., Dankel, K. R., Lintvedt, T. A., Kafle, B., Cattaldo, M., Matić, J., et al. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.342005 · Cited by 9
Stager, M. A., Peroza, C., Villaumié, J., Bilham, C., Desmond, C. R., Harris, M., Sambasivan, R., Rowe, G., Chen, L., & Tucker, C. (2024) · Organic Process Research & Development · doi:10.1021/acs.oprd.4c00432 · Cited by 9
Poulsen, J., Nielsen, K. A., & Bauer‐Brandl, A. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114519 · Cited by 9
Chemical Knowledge via In Situ Analytics: Advancing Quality and Sustainability
Hébrault, D., Rein, A. J., & Wittkamp, B. (2022) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.2c00292 · Cited by 9
Floris, P., McGillicuddy, N., Morrissey, B., Albrecht, S., Kaisermayer, C., Hawe, D., Riordan, L., Lindeberg, A., Forestell, S., & Bones, J. (2019) · Process Biochemistry · doi:10.1016/j.procbio.2019.08.014 · Cited by 10
Nachtmann, M., Keck, S. P., Braun, F., Eckhardt, H. S., Mattolat, C., Gretz, N., Scholl, S., & Rädle, M. (2018) · Journal of sensors and sensor systems · doi:10.5194/jsss-7-543-2018 · Cited by 9
“In their review of Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bio-processing Esmonde-White et al. (2017) describe the tracking of specific ethanol and glucose peaks in the fingerprint region.”
BackgroundModular and Automated Workflow for Streamlined Raman Signal Analysis
Kizilov, M., Cheburkanov, V. D., Harrington, J. T., & Yakovlev, V. V. (2025) · Journal of Raman Spectroscopy · doi:10.1002/jrs.70042 · Cited by 8
Recent Developments in Bioprocess Monitoring Systems
Rahmatnejad, V., Wei, Y., & Rao, G. (2023) · Cell engineering · doi:10.1007/978-3-031-45669-5_2 · Cited by 9
Shokoufi, N., Vosough, M., Rahimzadegan-Asl, M., Abbasi-Ahd, A., & Khatibeghdami, M. (2020) · International Journal of Analytical Chemistry · doi:10.1155/2020/2921417 · Cited by 8
Michalska, K., Lewandowska, K., Mizera, M., Bocian, W., Pałys, B., & Cielecka‐Piontek, J. (2020) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2020.128396 · Cited by 8
Khanal, O. (2022) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2022.102796 · Cited by 8
Nilsson, N., Henriksen, K. N., Boetker, J. P., Andersen, N. H., Larsen, B. S., Rantanen, J., Tho, I., & Brustugun, J. (2023) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.2c00983 · Cited by 8
PAT-Facilitated Pharmaceutical Crystallization Development through Mechanistic Understanding
Fung, P., Mah, H., Goldberg, A. F. G., Rieder, C. J., Sun, H., Su, Z., Du, J., & Lai, C. J. (2020) · Crystal Growth & Design · doi:10.1021/acs.cgd.0c01171 · Cited by 8
ENDBOSS: Industrial endpoint detection using batch-specific control spaces of spectroscopic data
Offermans, T., Wijker, T.-H., Folcarelli, R., Heemskerk, R., Lamers, P. P., Proença, M., Tran, T. N., Buydens, L. M. C., & Jansen, J. J. (2020) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2020.104229 · Cited by 8
“This is especially common for bioproductions, due to the nature of working with large molecule structures [11,12].”
BackgroundEbner, J., Humer, D., Klausser, R., Rubus, V., Pell, R., Spadiut, O., & Kopp, J. (2021) · Bioengineering · doi:10.3390/bioengineering8060078 · Cited by 10
“However, according to quality by design (QbD) principles in pharmaceutical manufacturing, an IPC must be applied [22] and, for this purpose, process analytical technology (PAT) tools are of a great advantage as they allow a timely process intervention [23,24].”
BackgroundRashedi, M., Demers, M., Khodabandehlou, H., Wang, T., Garvin, C., & Rianna, S. (2025) · Biotechnology Progress · doi:10.1002/btpr.70020 · Cited by 7
“22 However, additional consideration is necessary to implement Raman spectroscopy for process control during the development stage.”
Borg, A., Elhabiri, M., Calvé, S. L., & Portaluri, V. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70118 · Cited by 7
“Therefore, Raman spectroscopy is a popular choice (Esmonde‐White et al. 2016), especially in bio‐processes occurring in aqueous media.”
Hara, R., Kobayashi, W., Yamanaka, H., Murayama, K., Shimoda, S., & Ozaki, Y. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-05065-z · Cited by 7
Hao, J., Chen, C., Jin, H., Chen, N., Zhou, J. W., Zhu, Y., Chung, K., & Pu, Q. (2020) · Translational Cancer Research · doi:10.21037/tcr-20-854 · Cited by 9
“Theoretically, RS detects a variation of wave-length or Raman shift resulted from the inelastic light scattering from certain molecules (14).”
BackgroundBērziņš, K., Mapley, J. I., Gordon, K. C., & Fraser‐Miller, S. J. (2022) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.2c00656 · Cited by 7
Performance assessment of probe-based Raman spectroscopy systems for biomedical analysis
Fitzgerald, S. T., Marple, E. T., & Mahadevan-Jansen, A. M. (2023) · Biomedical Optics Express · doi:10.1364/boe.494289 · Cited by 7
Bērziņš, K., Meiland, P., Aljabbari, A., & Boyd, B. J. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c04540 · Cited by 7
Dias, F. M., Rabello, J. P., Guardalini, L. G. O., Leme, J., Bernardino, T. C., Pires, L., Mendonça, M., Tonso, A., Jorge, S. A. C., & Núñez, E. G. F. (2024) · Biochemical Engineering Journal · doi:10.1016/j.bej.2024.109441 · Cited by 7
Monago‐Maraña, O., Wold, J. P., Remberg, S. F., Sanden, K. W., & Afseth, N. K. (2024) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2024.124903 · Cited by 7
Sun, N., Chang, L., Lü, Y., & Wu, W. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14051052 · Cited by 7
la Rosa, M. V. G. D., Báez, J. P. F., Romañach, R. J., López-Mejías, V., & Stelzer, T. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114386 · Cited by 7
Deep learning for Raman spectroscopy: Benchmarking models for upstream bioprocess monitoring
Lange, C., Altmann, M., Stors, D., Seidel, S., Moynahan, K., Cai, L., Born, S., Neubauer, P., & Bournazou, M. N. C. (2025) · Measurement · doi:10.1016/j.measurement.2025.118884 · Cited by 10
Ma, Y., Yuan, X., Yewale, A., & Benyahia, B. (2026) · Particuology · doi:10.1016/j.partic.2026.01.014 · Cited by 9
Impact of bioreactor process parameters and yeast biomass on Raman spectra
Klaverdijk, M., Nemati, M., Ottens, M., & Klijn, M. E. (2025) · Biotechnology Progress · doi:10.1002/btpr.70050 · Cited by 7
Wang, X., Wang, J., Ding, H., & Pan, M. (2025) · Surface Science Reports · doi:10.1016/j.surfrep.2025.100660 · Cited by 7
Jin, H., He, X., Zhou, H., Zhang, M., Tang, Q., Lin, L., Hao, J., & Zeng, R. (2020) · Medicine · doi:10.1097/md.0000000000020933 · Cited by 6
To Acquire or Not to Acquire: Evaluating Compressive Sensing for Raman Spectroscopy in Biology
Raj, P., Wu, L., Kim, J. H., Bhatt, R., Glunde, K., & Barman, I. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01732 · Cited by 5
Ramamoorthy, S. (2026) · Pharmaceutical Research · doi:10.1007/s11095-026-04054-y · Cited by 5
“…of RTRT for impurity control remains limited and typically requires extensive validation demonstrating that in-process monitoring provides equivalent or superior assurance compared to traditional end-product testing, along with robust systems for data integrity and decision-making algorithms [151].”
InfluentialWacogne, B., Vaccari, N., Koubevi, C., Podevin, M. B., Robert-Nicoud, M., Rouleau, A., & Frelet‐Barrand, A. (2022) · Sensors · doi:10.3390/s22239223 · Cited by 5
A Critical Review on Recently Used PAT in Pharmaceutical Industry
Swami, A. G., Chakankar, S., Chavan, P., Limaye, D., & Tagalpallewar, A. A. (2023) · Research Journal of Pharmacy and Technology · doi:10.52711/0974-360x.2023.00724 · Cited by 5
Completely noninvasive multi-analyte monitoring system for cell culture processes
Rahmatnejad, V., Tolosa, M., Ge, X.-D., & Rao, G. (2024) · Biotechnology Letters · doi:10.1007/s10529-024-03521-z · Cited by 4
Ergot alkaloid control in biotechnological processes and pharmaceuticals (a mini review)
Volnin, A., Parshikov, A., Tsybulko, N. S., Мизина, П. Г., & Sidelnikov, N. I. (2024) · Frontiers in Toxicology · doi:10.3389/ftox.2024.1463758 · Cited by 5
Sinha, R., Anand, S., Singh, D., Tripathi, S., Shukla, P., Singh, S., & Srivastava, P. (2022) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2022.108797 · Cited by 7
Metadata
- Authors
- Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2016-08-04
- Volume
- 409
- Issue
- 3
- Pages
- 637-649
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- PMC
- PMC5233728
- OpenAlex
- W2497039129
- Cited by
- 332
- References
- 103
- Citations by year
- 2026: 43 · 2025: 36 · 2024: 42 · 2023: 31 · 2022: 35 · 2021: 36 · 2020: 50 · 2019: 26 · 2018: 23 · 2017: 8 · 2016: 1
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR007080)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- Raman spectroscopy, process analytical technology, pharmaceutical manufacturing, bioprocessing, quality by design, continuous production, real-time release testing, statistical process control, in situ monitoring
- MeSH terms
- Biotechnology, Spectrum Analysis, Raman, Technology, Pharmaceutical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.