Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bioprocessing
Open accessThe DOI matches its Crossref record; 102 of the 103 references it cites were found in a registry or an index.
Abstract
Adoption of Quality by Design (QbD) principles, regulatory support of QbD, process analytical technology (PAT), and continuous manufacturing are major factors effecting new approaches to pharmaceutical manufacturing and bioprocessing. In this review, we highlight new technology developments, data analysis models, and applications of Raman spectroscopy, which have expanded the scope of Raman spectroscopy as a process analytical technology. Emerging technologies such as transmission and enhanced reflection Raman, and new approaches to using available technologies, expand the scope of Raman spectroscopy in pharmaceutical manufacturing, and now Raman spectroscopy is successfully integrated into real-time release testing, continuous manufacturing, and statistical process control. Since the last major review of Raman as a pharmaceutical PAT in 2010, many new Raman applications in bioprocessing have emerged. Exciting reports of in situ Raman spectroscopy in bioprocesses complement a growing scientific field of biological and biomedical Raman spectroscopy. Raman spectroscopy has made a positive impact as a process analytical and control tool for pharmaceutical manufacturing and bioprocessing, with demonstrated scientific and financial benefits throughout a product's lifecycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Schematic comparing variants of sample excitation (solid line) and signal collection [dashed line(s)] used in Raman spectroscopy in measuring turbid media. (a) Backscattered Raman is a commonly used geometry that uses a single site of excitation with collection of signal close (<1 mm) to the excitation. As applied to Raman microscopy, this approach is called epi-illumination as a single microscope objective is used to excite the sample and collect Raman signal. The sampling volume in backscattered Raman is generally small, both in the lateral and axial dimensions. Thus, backscattered Raman is a good approach for measuring a surface. (b) Overlapping a defocused or wide laser beam with multiple collection fibers in a backscattering-like geometry is called wide area Raman (also known as large volumetric or global illumination Raman). (c) Separating collection fibers from the sample excitation by a small distance (Δd = 1–6 mm) enables collection of diffusely scattered Raman photons, known as a spatially-offset Raman spectroscopy (SORS). (d) Transmission Raman collects Raman photons diffusely scattered through a sample. Wide area, spatially-offset Raman spectroscopy (SORS) and transmission Raman provides representative sampling in turbid media and enables collection of Raman signal from buried layers in a layered sample](https://figures.cochat.ai/paper-figures/e5a0bbbc329941ad87050f571a218a65/raman-spectroscopy-as-a-process-analytical-technology-for-pharmaceutical-figure-1.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the monitoring of intracellular and extracellular macromolecules in bioprocesses share many intrinsic similarities to yeast and bacteria bioprocesses, which have been extensively reviewed together due to these similarities [20,21,29].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [29]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Since our critical review of Raman spectroscopy in pharmaceutical manufacturing and bioprocessing in 2016 [18], we have seen developments in the use of Raman variants or enhancement strategies in basic science applications, expansion of in situ Raman measurements in upstream bioprocessing, and increasing compatibility of process Raman with process automation.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
The cited source says what the claim attributes to it.
In the citing paper
“Variations in the geometry of optical fibers and lenses within the probe can enable a variety of sampling options including backscattered, large volumetric, spatially offset Raman, and transmission Raman.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
In the citing paper
“These include the need for large and representative datasets, optimal preprocessing techniques, handling environmental and noise sensitivities, high initial costs, and ensuring regulatory compliance [67].”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [67]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Production of recombinant protein therapeutics in cultivated mammalian cells
Wurm, F. M. (2004) · Nature Biotechnology · doi:10.1038/nbt1026 · Cited by 2,032 · cited 1×
“Production of protein therapeutics by mammalian cells is the most widely used bioprocess because of its ability to properly produce and fold a recombinant protein, with 60–70 % of biopharmaceuticals using this bioprocess [79, 80].”
BackgroundReference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 1×
“There are excellent reviews providing Raman spectra of biomolecules, complete with tables of band assignments [66, 67].”
BackgroundTissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352 · cited 1×
“Most cell and tissue spectroscopy is performed in the Btherapeutic^ near-infrared window (650– 1350 nm) because optical scattering is dominant and water absorption is at a minimum [14, 15].”
BackgroundBabuška, R. (1998) · International Series in Intelligent Technologies · doi:10.1007/978-94-011-4868-9 · Cited by 1,318
Biological Applications of Raman Spectroscopy
(2000) · Infrared and Raman Spectroscopy of Biological Materials · doi:10.1201/b16936-17 · Cited by 1,088
Sturgeon, R. (1988) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/0584-8547(88)80189-7 · Cited by 979
Vo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681 · cited 1×
“API or excipient particles and cellular organelles, such as mitochondria and nuclei, also strongly scatter light [16, 17].”
BackgroundMascia, S., Heider, P. L., Zhang, H., Lakerveld, R., Benyahia, B., Barton, P. I., Braatz, R. D., Cooney, C. L., Evans, J. M. B., Jamison, T. F., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305429 · Cited by 599
De Beer, T., Burggraeve, A., Fonteyne, M., Saerens, L., Remon, J. P., & Vervaet, C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.012 · Cited by 559
Research works printed but not linked: 4
- Slater JB Tedesco TM Fairchild RC Lewis IR Lewis IR Edwards HGM Raman spectrometry and its adaptation to the industrial environment Handbook of Raman spectroscopy: from the research laboratory to the process line 2001 New York Marcel-Dekker
- Kourti T Davis B The business benefits of quality by design (QbD) Pharm Eng 2012 32 4 1 10
- Moore CMV Regulatory perspective on real time release testing (RTRT) 2011 Washington DC Proceedings of the AAPS Annual Meeting
- Gervasio GJ Pelletier MJ On-line Raman analysis of PCl3 reactor material J Process Anal Chem 1997 3 1/2 7 11
Cited by
Items 301–351 of 351
Vishakha, V., & Jančář, J. (2024) · ChemRxiv · doi:10.26434/chemrxiv-2024-c1b8w
Metawea, A., Albadarin, A. B., Jović, O., Aramouni, N. A. K., Walker, G., & Mouras, R. (2025) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2025.113558
Recent Advances in Liquid–Liquid Extraction in Flow of Radiometals for Positron Emission Tomography
Zhuravlev, F. A. (2025) · Springer eBooks · doi:10.1007/978-3-031-84632-8_5
Offline Raman monitoring of SARS-CoV-2 VLP upstream stage using two culture media
Rabello, J. P., Fontes, I. D. S., Dias, F. M., Camalhonte, S. O., Guardalini, L. G. O., Tanaka, J. L., Leme, J., Bernardino, T. C., Sposito, F. S., Dias, E., et al. (2025) · Spectroscopy Letters · doi:10.1080/00387010.2025.2541638
“[8,12] 13–16] The Raman spectra initially undergo pretreatment to improve the relevant information in the spectra, then calibration is necessary, in which chemometric mathematical models perform a correlation between the spectra data and chemical variables.”
Ji, Y., Ayesa, U., Lévesque, F., & Qin, Y. (2025) · Organic Process Research & Development · doi:10.1021/acs.oprd.5c00252
An Introduction to Quantitative Spectroscopy
Peru, D. A. (2025) · Wiley eBooks · doi:10.1002/9781394227259.ch1
Kim, J. Y., Yeo, S., Yoo, J.-H., Kim, T., & Choi, D. H. (2025) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-025-00784-0
Dib, O. H., Assaf, A., Pean, A., Yannick, F., Zalouk‐Vergnoux, A., Thouand, G., & Durand, M.-J. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-025-06293-1
Analysis and monitoring of single HaCaT cells using volumetric Raman mapping and machine learning
Greenop, M. (2024) · Lancaster EPrints (Lancaster University) · doi:10.17635/lancaster/thesis/2223
Reyes Davila, J. S. (2024) · PolyPublie (École Polytechnique de Montréal)
Rebellato Giordano Martim, F. (2024) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Carvalho, V. D. C. F. D. (2022) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 1
Kallio, K. (2025) · UTUPub (University of Turku)
Zhou, X., Duan, S., Liu, Y., Chen, S., Ma, Y., Wang, T., Luo, A., Zhang, S., & Wen, Z. (2026) · Biotechnology and Bioprocess Engineering · doi:10.1007/s12257-026-00259-5
O'Sullivan, E., O′Shea, D., Devereux, M. M., Howe, O. L., & Byrne, H. J. (2025) · Metallomics · doi:10.1093/mtomcs/mfaf044
Li, M. (2018) · theses.fr (ABES) · doi:10.70675/a848a7b2z4ac9z4cd2z89b5z0c42807cd0d1 · Cited by 1
“Pour la plupart de ces études, la molécule produite provoquait un signal Raman raisonnablement fort avec des pics bien distincts du bruit de fond (Esmonde-White et al., 2017).”
BackgroundInfluentialAnalysis of therapeutic solutions for cancer treatment by vibrational spectroscopy
Abdelbagi, A. A. M. (2020) · theses.fr (ABES) · doi:10.70675/469f40dcz0fd3z4d78zb01ez369f07531741
Online monitoring of bioreactors by Raman spectroscopy and machine learning
Yang, N. (2024) · theses.fr (ABES) · doi:10.70675/cfae52a0zdcd5z41a8z877bz3023f86d9a13
Elderderi, S. (2022) · theses.fr (ABES) · doi:10.70675/6fd958dezbeb1z4c78z8250z7ad79387da5b
Boldt, S., Sinn, G., Mittenzwey, K.-H., Zhai, O., Mittenzwey, H., Lerche, D., Gleiß, M., & Nirschl, H. (2026) · Applied Spectroscopy · doi:10.1177/00037028261440919
“8 Moreover, D [3,2] is a common key parameter in emulsion and CFD simulations, where surface-area – dependent processes such as coalescence, mass transfer, and interfacial kinetics must be considered.”
InfluentialRaman Spectroscopy for Bioplastic Research
Dutta, S., Sarode, V. V., Dehury, B., & Patil, A. (2026) · Biological and medical physics, biomedical engineering · doi:10.1007/978-3-032-15306-7_6
Intensity Calibration of Raman Instruments: A Review †
Pilot, R. (2026) · Photochemistry and Spectroscopy · doi:10.53941/ps.2026.100018
“Its fields of application include: the pharmaceutical sector [3,4], for example in studying drug formulations [5] and investigating different polymorphic forms [6]; the characterization of 2D materials [7], carbon-based materials [8–10] and polymers [11–13]; forensic science [14]; cultural heritage…”
Zherebtsov, A. A., Tarazanova, M. A., Шарадзе, Г. А., Dvoeglazov, K. N., Pavlyukevich, E. Y., Panov, V., Petrov, V. A., & Budylin, G. S. (2025) · Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya · doi:10.55959/msu05799392.81.2610404
Spectroscopy-Based Cell Culture Predictive Monitoring
Kanfoud, A., Gerkens, P., Bastin, M., Rondia, L., Ceulemans, F., Donnay, K., Debuisseret, B., Cornet, T., de Lannoy, G., & Helleputte, T. (2026) · BioTech · doi:10.3390/biotech15020035
In vitro–in silico applications for tablet dosage forms
Nagar, L., Saini, A., Gulati, N., Hussain, T., Gupta, V. K., Dua, K., & Dureja, H. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36751-9.00006-1
Applications of Raman Spectroscopy in Early Phase Chemical Development
Ramachandran, R., Alla, S., Bajpai, L., Young, J., & Jayaraman, K. S. (2026) · Organic Process Research & Development · doi:10.1021/acs.oprd.5c00376
Research methods and protocols
Afzal, J. (2026) · Developments in environmental science · doi:10.1016/b978-0-443-41688-0.00013-x
Thomas, G. P., Marks, B. C., Alvarado-Hernández, B. B., Woodling, M., O'Connor, J., Ortiz, R., Higgins, J., & Shanter, J. (2026) · Biotechnology Progress · doi:10.1002/btpr.88532
Srikanth, R., Kuang, B., Doddridge, G. D., Shah, K., Kwok, A., Xia, L., Anantharaman, S., Lowry, B., Harcum, S. W., & Abu‐Absi, N. (2026) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2026.117625
Alcântara, J. M. G., Fessler, B., Peredo, A., Li, M., Zell, N., Geißler, A., & Munzer, D. G. (2026) · Applied Spectroscopy Practica · doi:10.1177/27551857261448240
O'Sullivan, E. (2026) · Arrow - TU Dublin (Technological University Dublin) · doi:10.21427/z5pf-8k67
Mikulasek, B., Umprecht, A., Kozma, B., Ettinger, P., & Oliver Spadiut, A. (2026) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-026-03394-8
“Combined with multivariate modeling approaches such as partial least squares regression (PLS), these measurements can support real-time monitoring and control [ 6–8].”
Patel, V., & Patel, V. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.07.24.740653
Shi, M., Liu, Y., Chen, H., Wang, Y., Zhao, L., Wang, X., Li, X., Liu, M., Wang, J., Wang, T., et al. (2026) · Biotechnology and Bioengineering · doi:10.1002/bit.70332
Gaikwad, A. S. (2026) · Current Pharmaceutical Analysis · doi:10.1016/j.cpan.2026.08.004
Đạt, N. T., Nguyen, T. T., An, T. V. T., Tin, V. D. T., Khang, N. H. D., Chuong, H. D., Thanh, T. T., Trang, H. T. K., & Tâm, H. Đ. (2026) · Measurement · doi:10.1016/j.measurement.2026.122961
Purification strategies for FCCVD-produced carbon nanotubes
Huang, X., & Cao, G. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.181196
Ghosal, S., PANDA, N., Jena, B. R., Maity, M., Bose, S., & Parhi, R. (2026) · ADMET & DMPK · doi:10.5599/admet.3565
“…of the raw material feed and monitored CQAs using chemometric methods, thereby reducing dependence on end-product testing and enabling RTRT. Implementing them aids process optimization, minimizes variability and waste, and ensures consistent product quality throughout the product lifecycle [86,87].”
Baoyi, 单. S., Yongshuai, 张. Z., Xingyue, 朱. Z., Kaiyu, 刘. L., Lichuan, 谷. G., Xiangyuan, 姜. J., Chi, W., & Jianqiang, 林. L. (2026) · Infrared and Laser Engineering · doi:10.3788/irla20250625
Patel, V. M., & Patel, N. A. (2026) · International Journal of Research and Review · doi:10.52403/ijrr.20260910
Li, R., Ma, X., Buono, F. G., Wu, H., Radomkit, S., Liu, J., Shao, X., & Song, J. J. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182114
Kashi, S., & Sung, Y. (2026) · AAPS PharmSciTech · doi:10.1208/s12249-026-03557-6
“…process analytical technologies (PAT), primarily point-source near-infrared and Raman spectroscopy, have become established tools for real-time, inline applications including blend uniformity, granule moisture monitoring, tablet coating thickness, and raw material verification [1–3].”
Hong, Y., & Zhao, J. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7511765
Mäkiniemi, K. (2024) · UEF eRepo (University of Eastern Finland)
Yarahmadi, S., Nemati, S., & Yarmohamadi, A. (2026) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-026-11096-7
“The effect of acquisition time was investigated by compar - ing spectra acquired at 300 and 600 ms. Increasing the integration time provides a greater photon collection period and can improve the signal-to-noise ratio, particularly for weak Raman features [17, 18].”
Artificial Intelligence-Assisted Raman Spectroscopy in Pharmacology and Pharmaceutical Manufacturing
Driza, N. O. M., Hamad, R. S. A., Ali, H. M. A., Mansour, A. A., & Driza, H. N. (2026) · African Journal of Advanced Pure and Applied Sciences · doi:10.65418/ajapas.v5i3.2114
Investigating Transferability of Multivariate Calibration Models for Bioprocessing Applications
Umprecht, A. (2026) · reposiTUm (TU Wien) · doi:10.34726/hss.2026.144580
Nondestructive quality control across the life cycle of bioprinted products
Elkadi, O. A., Budharaju, H., & Ozbolat, I. T. (2026) · Trends in biotechnology · doi:10.1016/j.tibtech.2026.09.025
Wilms, T., & Knorn, S. (2026) · Biotechnology Progress · doi:10.1002/btpr.88564
Optical coherence tomography as a process analytical technology for oral film formulations
Uth, L.-L. D., Wolfgang, M., Klinken, S., Khinast, J., & Breitkreutz, J. (2026) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2026.104582
Metadata
- Authors
- Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2016-08-04
- Volume
- 409
- Issue
- 3
- Pages
- 637-649
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- PMC
- PMC5233728
- OpenAlex
- W2497039129
- Cited by
- 332
- References
- 103
- Citations by year
- 2026: 43 · 2025: 36 · 2024: 42 · 2023: 31 · 2022: 35 · 2021: 36 · 2020: 50 · 2019: 26 · 2018: 23 · 2017: 8 · 2016: 1
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR007080)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- Raman spectroscopy, process analytical technology, pharmaceutical manufacturing, bioprocessing, quality by design, continuous production, real-time release testing, statistical process control, in situ monitoring
- MeSH terms
- Biotechnology, Spectrum Analysis, Raman, Technology, Pharmaceutical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.