Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bioprocessing
Open accessThe DOI matches its Crossref record; 102 of the 103 references it cites were found in a registry or an index.
Abstract
Adoption of Quality by Design (QbD) principles, regulatory support of QbD, process analytical technology (PAT), and continuous manufacturing are major factors effecting new approaches to pharmaceutical manufacturing and bioprocessing. In this review, we highlight new technology developments, data analysis models, and applications of Raman spectroscopy, which have expanded the scope of Raman spectroscopy as a process analytical technology. Emerging technologies such as transmission and enhanced reflection Raman, and new approaches to using available technologies, expand the scope of Raman spectroscopy in pharmaceutical manufacturing, and now Raman spectroscopy is successfully integrated into real-time release testing, continuous manufacturing, and statistical process control. Since the last major review of Raman as a pharmaceutical PAT in 2010, many new Raman applications in bioprocessing have emerged. Exciting reports of in situ Raman spectroscopy in bioprocesses complement a growing scientific field of biological and biomedical Raman spectroscopy. Raman spectroscopy has made a positive impact as a process analytical and control tool for pharmaceutical manufacturing and bioprocessing, with demonstrated scientific and financial benefits throughout a product's lifecycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Schematic comparing variants of sample excitation (solid line) and signal collection [dashed line(s)] used in Raman spectroscopy in measuring turbid media. (a) Backscattered Raman is a commonly used geometry that uses a single site of excitation with collection of signal close (<1 mm) to the excitation. As applied to Raman microscopy, this approach is called epi-illumination as a single microscope objective is used to excite the sample and collect Raman signal. The sampling volume in backscattered Raman is generally small, both in the lateral and axial dimensions. Thus, backscattered Raman is a good approach for measuring a surface. (b) Overlapping a defocused or wide laser beam with multiple collection fibers in a backscattering-like geometry is called wide area Raman (also known as large volumetric or global illumination Raman). (c) Separating collection fibers from the sample excitation by a small distance (Δd = 1–6 mm) enables collection of diffusely scattered Raman photons, known as a spatially-offset Raman spectroscopy (SORS). (d) Transmission Raman collects Raman photons diffusely scattered through a sample. Wide area, spatially-offset Raman spectroscopy (SORS) and transmission Raman provides representative sampling in turbid media and enables collection of Raman signal from buried layers in a layered sample](https://figures.cochat.ai/paper-figures/e5a0bbbc329941ad87050f571a218a65/raman-spectroscopy-as-a-process-analytical-technology-for-pharmaceutical-figure-1.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the monitoring of intracellular and extracellular macromolecules in bioprocesses share many intrinsic similarities to yeast and bacteria bioprocesses, which have been extensively reviewed together due to these similarities [20,21,29].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [29]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Since our critical review of Raman spectroscopy in pharmaceutical manufacturing and bioprocessing in 2016 [18], we have seen developments in the use of Raman variants or enhancement strategies in basic science applications, expansion of in situ Raman measurements in upstream bioprocessing, and increasing compatibility of process Raman with process automation.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
The cited source says what the claim attributes to it.
In the citing paper
“Variations in the geometry of optical fibers and lenses within the probe can enable a variety of sampling options including backscattered, large volumetric, spatially offset Raman, and transmission Raman.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
In the citing paper
“These include the need for large and representative datasets, optimal preprocessing techniques, handling environmental and noise sensitivities, high initial costs, and ensuring regulatory compliance [67].”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [67]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Production of recombinant protein therapeutics in cultivated mammalian cells
Wurm, F. M. (2004) · Nature Biotechnology · doi:10.1038/nbt1026 · Cited by 2,032 · cited 1×
“Production of protein therapeutics by mammalian cells is the most widely used bioprocess because of its ability to properly produce and fold a recombinant protein, with 60–70 % of biopharmaceuticals using this bioprocess [79, 80].”
BackgroundReference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 1×
“There are excellent reviews providing Raman spectra of biomolecules, complete with tables of band assignments [66, 67].”
BackgroundTissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352 · cited 1×
“Most cell and tissue spectroscopy is performed in the Btherapeutic^ near-infrared window (650– 1350 nm) because optical scattering is dominant and water absorption is at a minimum [14, 15].”
BackgroundBabuška, R. (1998) · International Series in Intelligent Technologies · doi:10.1007/978-94-011-4868-9 · Cited by 1,318
Biological Applications of Raman Spectroscopy
(2000) · Infrared and Raman Spectroscopy of Biological Materials · doi:10.1201/b16936-17 · Cited by 1,088
Sturgeon, R. (1988) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/0584-8547(88)80189-7 · Cited by 979
Vo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681 · cited 1×
“API or excipient particles and cellular organelles, such as mitochondria and nuclei, also strongly scatter light [16, 17].”
BackgroundMascia, S., Heider, P. L., Zhang, H., Lakerveld, R., Benyahia, B., Barton, P. I., Braatz, R. D., Cooney, C. L., Evans, J. M. B., Jamison, T. F., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305429 · Cited by 599
De Beer, T., Burggraeve, A., Fonteyne, M., Saerens, L., Remon, J. P., & Vervaet, C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.012 · Cited by 559
Research works printed but not linked: 4
- Slater JB Tedesco TM Fairchild RC Lewis IR Lewis IR Edwards HGM Raman spectrometry and its adaptation to the industrial environment Handbook of Raman spectroscopy: from the research laboratory to the process line 2001 New York Marcel-Dekker
- Kourti T Davis B The business benefits of quality by design (QbD) Pharm Eng 2012 32 4 1 10
- Moore CMV Regulatory perspective on real time release testing (RTRT) 2011 Washington DC Proceedings of the AAPS Annual Meeting
- Gervasio GJ Pelletier MJ On-line Raman analysis of PCl3 reactor material J Process Anal Chem 1997 3 1/2 7 11
Cited by
Tripathi, N. K., & Shrivastava, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00420 · Cited by 575
“, lying outside the bioreactor, requiring an automatic sampling interface to the bioreactor that enables a sample to be drawn and delivered to the analyzer for bioreactor content analysis), at-line (manual sampling and analysis), and in-line (directly connected to the bioreactor) monitoring of samples, are near-infrar…”
InfluentialZhang, W., Ma, J., & Sun, D.-W. (2021) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2020.1828814 · Cited by 220
“Micro-Raman spectroscopy employs an epi-illumination configuration, whose microscope objective delivers not only focused laser light to the microscope but also collects Raman-scattered photons (Esmonde-White et al. 2017).”
BackgroundDeidda, R., Sacre, P.-Y., Clavaud, M., Coïc, L., Avohou, H., Hubert, P., & Ziemons, E. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.02.035 · Cited by 193
Wasalathanthri, D. P., Rehmann, M. S., Song, Y., Gu, Y., Mi, L., Shao, C., Chemmalil, L., Lee, J., Ghose, S., Borys, M. C., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27461 · Cited by 177
Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160
“Inline monitoring has shown utility for collecting continuous and instantaneous data (when compared to the long duration of a typical mammalian cell culture, ten or more days), and both forms of bioprocesses monitoring have demonstrated that they can provide useful information on the scale-up of fed-batch processes (t…”
Quality by control: Towards model predictive control of mammalian cell culture bioprocesses
Sommeregger, W., Sissolak, B., Kandra, K., von Stosch, M., Mayer, M., & Striedner, G. (2017) · Biotechnology Journal · doi:10.1002/biot.201600546 · Cited by 159
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“Foundational work in 2011 to 2016 quickly established industrial use of Raman spectroscopy for upstream monitoring and control [69].”
BackgroundSelf-citationGargalo, C. L., Udugama, I., Pontius, K., Lopez, P. C., Nielsen, R. F., Hasanzadeh, A., Mansouri, S. S., Bayer, C., Junicke, H., & Gernaey, K. V. (2020) · Journal of Industrial Microbiology and Biotechnology · doi:10.1007/s10295-020-02308-1 · Cited by 133
“Spectroscopic sensors have, in some occasions, been labeled ‘soft sensors’ in the bioprocessing literature due to the fact that spectroscopic data is modeled using software and these models produce information similar to hardware sensors [57, 66, 71].”
MethodModern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Applications of Fourier transform infrared spectroscopy to pharmaceutical preparations
Song, Y., Cong, Y., Wang, B., & Zhang, N. (2020) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2020.1737671 · Cited by 132
“Easily affected by optical system parameters, fluorescence and other factors Identification of chemical structure and composition, characterization of crystalline and amorphous phases, molecular kinetic process, compatibility of blends and molecular interactions and component quantitative analysis [25]”
BackgroundBioprocessing 4.0: a pragmatic review and future perspectives
Isoko, K., Cordiner, J. L., Kis, Z., & Moghadam, P. Z. (2024) · Digital Discovery · doi:10.1039/d4dd00127c · Cited by 97
Artifacts and Anomalies in Raman Spectroscopy: A Review on Origins and Correction Procedures
Vulchi, R. T., Morgunov, V., Junjuri, R., & Bocklitz, T. W. (2024) · Molecules · doi:10.3390/molecules29194748 · Cited by 123
Raman spectroscopy for real-time and in situ monitoring of mechanochemical milling reactions
Lukin, S., Užarević, K., & Halász, I. (2021) · Nature Protocols · doi:10.1038/s41596-021-00545-x · Cited by 118
Nagy, B., Farkas, A., Gyürkés, M., Komaromy-Hiller, S., Démuth, B., Szabó, B., Nusser, D., Borbás, E., Marosi, G., & Nagy, Z. K. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.07.041 · Cited by 113
Ma, Y., Wu, S., Macaringue, E. G. J., Zhang, T., Gong, J., & Wang, J. (2020) · Organic Process Research & Development · doi:10.1021/acs.oprd.9b00362 · Cited by 109
Time-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107
Bioprocess digital twins of mammalian cell culture for advanced biomanufacturing
Park, S., Park, C.-H., Choi, D., Hong, J. K., & Lee, D. (2021) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2021.100702 · Cited by 111
Tian, Y., Jacobs, E., Jones, D. S., McCoy, C. P., Wu, H., & Andrews, G. P. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119545 · Cited by 100
Araujo-Andrade, C., Bugnicourt, E., Philippet, L., Rodríguez-Turienzo, L., Nettleton, D., Hoffmann, L., & Schlummer, M. (2021) · Waste Management & Research The Journal for a Sustainable Circular Economy · doi:10.1177/0734242x21997908 · Cited by 104
“Due to the possibility of using optical fibres, RS is a good candidate for industrial monitoring applications in the food, bio-medical/pharmaceutical, mining, and polymer industries (Esmonde-White et al., 2017; Everall and King, 1999; Knop and Kleinebudde, 2013).”
BackgroundRaman Spectroscopy for Process Analytical Technologies of Pharmaceutical Secondary Manufacturing
Nagy, B., Farkas, A., Borbás, E., Vass, P., Nagy, Z. K., & Marosi, G. (2019) · AAPS PharmSciTech · doi:10.1208/s12249-018-1201-2 · Cited by 89
Trends in pharmaceutical analysis and quality control by modern Raman spectroscopic techniques
Silge, A., Weber, K., Cialla‐May, D., Müller-Bötticher, L., Fischer, D., & Popp, J. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116623 · Cited by 92
Rangan, S., Schulze, H. G., Vardaki, M. Z., Blades, M. W., Piret, J. M., & Turner, R. F. B. (2020) · The Analyst · doi:10.1039/c9an01811e · Cited by 88
Wei, X., Cao, B., Luo, C., Huang, H., Tan, P., Xu, X., Xu, R., Yang, M., Zhang, Y., Han, L., et al. (2020) · Chinese Medicine · doi:10.1186/s13020-020-00335-9 · Cited by 90
Tulsyan, A., Schorner, G., Khodabandehlou, H., Wang, T., Coufal, M., & Undey, C. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27100 · Cited by 82
Li, M., Ebel, B., Paris, C., Chauchard, F., Guedon, E., & Marc, A. (2018) · Biotechnology Progress · doi:10.1002/btpr.2604 · Cited by 67
“Signals from water molecules in Raman scattering are much weaker than in other spectroscopies such as infrared spectroscopy.(16,17) Its utility in real-time monitoring of nutrients, metabolites, byproducts, or cell densities during mammalian cell culture processes has been recently demonstrated in different studies.”
BackgroundGalata, D. L., Farkas, A., Könyves, Z., Mészáros, L. A., Szabó, E., Csontos, I., Pálos, A., Marosi, G., Nagy, Z. K., & Nagy, B. (2019) · Pharmaceutics · doi:10.3390/pharmaceutics11080400 · Cited by 83
Continuous downstream bioprocessing for intensified manufacture of biopharmaceuticals and antibodies
Gerstweiler, L., Bi, J., & Middelberg, A. P. J. (2021) · Chemical Engineering Science · doi:10.1016/j.ces.2020.116272 · Cited by 68
The Role of Big Data in Industrial (Bio)chemical Process Operations
Udugama, I. A., Gargalo, C. L., Yamashita, Y., Taube, M. A., Palazoğlu, A., Young, B. R., Gernaey, K. V., Külahçı, M., & Bayer, C. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c01872 · Cited by 70
Rafferty, C., Johnson, K., O'Mahony, J., Burgoyne, B., Rea, R., & Balss, K. M. (2020) · Biotechnology Progress · doi:10.1002/btpr.2977 · Cited by 63
McAvan, B. S., Bowsher, L. A., Powell, T., O’Hara, J. F., Spitali, M., Goodacre, R., & Doig, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00627 · Cited by 61
Kornecki, M., & Strube, J. (2018) · Bioengineering · doi:10.3390/bioengineering5010025 · Cited by 61
“Raman spectroscopy, in combination with chemometric analysis methods, can, for example, be used for the determination of the total or viable cell concentration, as well as for the substrate and metabolite concentration [4,20].”
MethodBiscaia-Caleiras, M., Fonseca, N. A., Lourenço, A. S., Moreira, J. N., & Simões, S. (2024) · Journal of Controlled Release · doi:10.1016/j.jconrel.2024.07.021 · Cited by 63
Vélez‐Escamilla, L. Y., & Contreras‐Torres, F. F. (2022) · Particle & Particle Systems Characterization · doi:10.1002/ppsc.202100217 · Cited by 58
Liu, Y., Zhang, C., Chen, J., Fernandez, J., Vellala, P., Kulkarni, T. A., Aguilar, I., Ritz, D., Lan, K., Patel, P., et al. (2022) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.09.011 · Cited by 57
Applications of bio-capacitance to cell culture manufacturing
Bergin, A., Carvell, J. P., & Butler, M. (2022) · Biotechnology Advances · doi:10.1016/j.biotechadv.2022.108048 · Cited by 60
Optics miniaturization strategy for demanding Raman spectroscopy applications
Ilchenko, O. O., Pilgun, Y., Михайлович, К. А., Slobodianiuk, D. V., Göksel, Y., Dumont, E., Vaut, L., Mazzoni, C., Morelli, L., Boisen, S., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47044-7 · Cited by 53
“Besides commercialdevices recentlydeveloped for monitoring of nutrients and metabolites through Raman 85,86 , several examples of on-line and off-line Raman process monitoring of industrial fermentation of bacteria, fungi and mammalian cells 87 have been reported in literature over the last years.”
Continuous Manufacturing and Molecular Modeling of Pharmaceutical Amorphous Solid Dispersions
Nambiar, A. G., Singh, M., Mali, A. R., Serrano, D. R., Kumar, R., Healy, A. M., Agrawal, A. K., & Kumar, D. K. (2022) · AAPS PharmSciTech · doi:10.1208/s12249-022-02408-4 · Cited by 52
“Fiber-optic probes are used in PAT Raman spectroscopy, with fiber designs with low separation between the activation and collection fibers (128).”
MethodYilmaz, D., Mehdizadeh, H., Navarro, D., Shehzad, A., O'Connor, M., & McCormick, P. (2020) · Biotechnology Progress · doi:10.1002/btpr.2947 · Cited by 51
Deng, J., Jiang, H., & Chen, Q. (2022) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2022.121148 · Cited by 51
Use of HPLC as an Enabler of Process Analytical Technology in Process Chromatography
Tiwari, A., Kateja, N., Chanana, S., & Rathore, A. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00897 · Cited by 48
Raman Spectroscopy for Quantitative Analysis in the Pharmaceutical Industry
de Jesus, J. I. S. D. S., Löbenberg, R., & Bou‐Chacra, N. A. (2020) · Journal of Pharmacy & Pharmaceutical Sciences · doi:10.18433/jpps30649 · Cited by 48
The Rocky Road From Fed-Batch to Continuous Processing With E. coli
Kopp, J., Slouka, C., Spadiut, O., & Herwig, C. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00328 · Cited by 53
Feidl, F., Garbellini, S., Luna, M. F., Vogg, S., Souquet, J., Broly, H., Morbidelli, M., & Butté, A. (2019) · Processes · doi:10.3390/pr7100683 · Cited by 46
Poth, M., Magill, G., Filgertshofer, A., Popp, O., & Großkopf, T. (2022) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6402 · Cited by 48
Velez-Silva, N. L., Drennen, J. K., & Anderson, C. A. (2022) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2022.121462 · Cited by 43
Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S. (2022) · Bioengineering · doi:10.3390/bioengineering9120762 · Cited by 42
Kozma, B., Hirsch, E., Gergely, S., Párta, L., Pataki, H., & Salgó, A. (2017) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.06.070 · Cited by 41
Rivera-Ordaz, A., Peli, V., Manzini, P., Barilani, M., & Lazzari, L. (2021) · BioDrugs · doi:10.1007/s40259-021-00503-9 · Cited by 47
Bioprocess Technologies that Preserve the Quality of iPSCs
Polanco, A., Kuang, B., & Yoon, S. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.03.006 · Cited by 42
Inoue, M., Hisada, H., Koide, T., Fukami, T., Roy, A., Carriere, J. T. A., & Heyler, R. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04365 · Cited by 39
In situ monitoring of cocrystals in formulation development using low-frequency Raman spectroscopy
Otaki, T., Tanabe, Y., Kojima, T., Miura, M., Ikeda, Y., Koide, T., & Fukami, T. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.03.008 · Cited by 38
Dzurendová, S., Shapaval, V., Tafintseva, V., Köhler, A., Byrtusová, D., Szotkowski, M., Márová, I., & Zimmermann, B. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22136710 · Cited by 38
“Moreover, it is very versatile, from in-situ monitoring of bioprocesses in bioreactors by a Raman fiber-optic probe [40], to the detailed cellular imaging by a confocal Raman microscope [36].”
BackgroundWei, B., Woon, N., Dai, L., Fish, R., Tai, M., Handagama, W., Yin, A., Jia, S., Maier, A. J., McDaniel, D., et al. (2021) · mAbs · doi:10.1080/19420862.2021.2007564 · Cited by 39
“…biopharmaceutical development, Raman spectroscopy is increasingly being used as a process analytical technology (PAT) for bioprocess monitoring, 6,12,13 with many established applications such as evaluating the components of the cell culture media,- 14,15 glucose and lactate concentration, 16,17…”
A comprehensive CHO SWATH-MS spectral library for robust quantitative profiling of 10,000 proteins
Sim, K. H., Liu, L. C.-Y., Tan, H. T., Tan, K. Y. S., Ng, D., Zhang, W., Yang, Y., Tate, S. A., & Bi, X. (2020) · Scientific Data · doi:10.1038/s41597-020-00594-z · Cited by 39
Quantification of protein glycation using vibrational spectroscopy
McAvan, B. S., France, A. P., Bellina, B., Barran, P. E., Goodacre, R., & Doig, A. J. (2020) · The Analyst · doi:10.1039/c9an02318f · Cited by 35
On digital twins in bioprocessing: Opportunities and limitations
Shariatifar, M., Rizi, M. S., Sotudeh‐Gharebagh, R., Zarghami, R., & Mostoufi, N. (2025) · Process Biochemistry · doi:10.1016/j.procbio.2025.05.023 · Cited by 40
Sauer, D. G., Melcher, M., Mosor, M., Walch, N., Berkemeyer, M., Scharl‐Hirsch, T., Leisch, F., Jungbauer, A., & Dürauer, A. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26984 · Cited by 35
Richelle, A., David, B., Demaegd, D., Dewerchin, M., Kinet, R., Morreale, A., Portela, R. M. C., Zune, Q., & von Stosch, M. (2020) · npj Systems Biology and Applications · doi:10.1038/s41540-020-0127-y · Cited by 43
Badr, S., & Sugiyama, H. (2020) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2020.01.003 · Cited by 36
Raman Spectroscopy as Process Analytical Tool in Downstream Processing of Biotechnology
Lin, Y. K., Leong, H. Y., Ling, T. C., Lin, D.-Q., & Yao, S.-J. (2021) · Chinese Journal of Chemical Engineering · doi:10.1016/j.cjche.2020.12.008 · Cited by 35
Essential Oil-Loaded NLC for Potential Intranasal Administration
Bonaccorso, A., Cimino, C., Manno, D. E., Tomasello, B., Serra, A., Musumeci, T., Puglisi, G., Pignatello, R., & Carbone, C. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13081166 · Cited by 36
“In particular, NLC were analyzed through Raman spectroscopy using a microRaman spectrometer, in order to obtain the so-called “molecular footprint” of the sample, which provides information about the sample’s molecular composition and structure [54].”
MethodGibbons, L. A., Rafferty, C., Robinson, K., Abad, M. C., Maslanka, F., Le, N., Mo, J., Clark, K., Madden, F., Hayes, R., et al. (2021) · Biotechnology Progress · doi:10.1002/btpr.3223 · Cited by 36
“Partial Least Squares (PLS) regression models are often employed to model Raman data as PLS modeling suits the linear nature of Raman signal versus analyte concentration.(22)”
MethodBenisch, M., Benzinger, D., Kumar, S., Hu, H., & Khammash, M. (2023) · Metabolic Engineering · doi:10.1016/j.ymben.2023.03.001 · Cited by 39
Podevin, M., Fotidis, I. A., & Angelidaki, I. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1398132 · Cited by 34
São Pedro, M. N., Klijn, M. E., Eppink, M. H., & Ottens, M. (2022) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.6920 · Cited by 34
Lintvedt, T. A., Andersen, P. V., Afseth, N. K., Marquardt, B. J., Gidskehaug, L., & Wold, J. P. (2022) · Applied Spectroscopy · doi:10.1177/00037028211056931 · Cited by 34
“The potential of in-line Raman applications have been demonstrated in several areas, such as in the pharmaceutical and bioprocessing domain, as reviewed by Esmonde-White et al.7 However, the literature on Raman spectroscopy for inline food evaluation is scarce, although the possibilities within the food industry are u…”
BackgroundLê, L. M. M., Berge, M., Tfayli, A. M., Zhou, J.-Y., Prognon, P., Baillet‐Guffroy, A., & Caudron, É. (2017) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2017.09.046 · Cited by 34
“It is a rapid, noninvasive and nondestructive analysis and this molecular vibrational spectroscopy, as in the case of near infrared spectroscopy, is widely used in process analytical technology (PAT) (André et al., 2015; Brouckaert et al., 2016; Esmonde-White et al., 2016).”
MethodHolzberg, T. R., Watson, V. E., Brown, S., Andar, A. U., Ge, X., Kostov, Y. V., Tolosa, L. M., & Rao, G. (2018) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2018.09.008 · Cited by 37
A comparative review of multi-rate moving horizon estimation schemes for bioprocess applications
Elsheikh, M., Hille, R., Tătulea-Codrean, A., & Krämer, S. (2021) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2020.107219 · Cited by 35
Emerging technologies for quality control of cell-based, advanced therapy medicinal products
Zia, S., Pizzuti, V., Paris, F., Alviano, F., Bonsi, L., Zattoni, A., Reschiglian, P., Roda, B., & Marassi, V. (2024) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2024.116182 · Cited by 35
Graf, A., Lemke, J. R., Schulze, M., Soeldner, R., Rebner, K., Hoehse, M., & Matuszczyk, J. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.719614 · Cited by 34
“In case of bioprocessing the wavelength of the excitation laser is usually in the near-infrared region to minimize unwanted disturbance of fluorescence (Esmonde-White et al., 2017).”
BackgroundRaman spectroscopy as a method to replace off‐line pH during mammalian cell culture processes
Rafferty, C., O'Mahony, J., Burgoyne, B., Rea, R., Balss, K. M., & Latshaw, D. C. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27197 · Cited by 31
Helal, N. A., Elnoweam, O., Eassa, H. A., Amer, A. M., Eltokhy, M. A., Helal, M. A., Fayyaz, H. A., & Nounou, M. I. (2019) · Pharmaceutical Patent Analyst · doi:10.4155/ppa-2019-0011 · Cited by 33
Allakhverdiev, E. S., Kossalbayev, B. D., Sadvakasova, A. K., Bauenova, M. O., MARATOVICH, B. A., Rodnenkov, O. V., Martynyuk, T. V., Maksimov, G. V., & Allakhverdiev, S. I. (2024) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/j.jphotobiol.2024.112870 · Cited by 29
Monago‐Maraña, O., Afseth, N. K., Knutsen, S. H., Wubshet, S. G., & Wold, J. P. (2021) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2021.111620 · Cited by 29
A Review of Pharmaceutical Robot based on Hyperspectral Technology
Su, X., Wang, Y., Mao, J., Chen, Y., Yin, A., Zhao, B., Zhang, H., & Liu, M. (2022) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-022-01602-7 · Cited by 29
Metawea, A., & Walker, G. (2025) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2025.01.020 · Cited by 28
Robustness of a continuous direct compression line against disturbances in feeding
Karttunen, A.-P., Poms, J., Sacher, S., Sparén, A., Samblás, C. R., Fransson, M., de Juan, L. M., Remmelgas, J., Wikström, H., Hsiao, W., et al. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118882 · Cited by 28
Effectual Bioprocess Development for Protein Production
Gupta, S. K., Dangi, A. K., Smita, M., Dwivedi, S., & Shukla, P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-815407-6.00011-3 · Cited by 34
Process Design of Continuous Powder Blending Using Residence Time Distribution and Feeding Models
Gyürkés, M., Madarász, L., Köte, Á., Domokos, A., Mészáros, D., Beke, Á. K., Nagy, B., Marosi, G., Pataki, H., Nagy, Z. K., et al. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12111119 · Cited by 28
Kozma, B., Salgó, A., & Gergely, S. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.06.005 · Cited by 27
Kashinath, K. P., Sanjay, L. R., Ashokbhai, M. K., Roy, S., Sardar, M. S., & Kaity, S. (2025) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2025.01.003 · Cited by 27
Fu, X., Zhong, L.-M., Cao, Y., Chen, H., & Lu, F. L. (2020) · Analytical Methods · doi:10.1039/d0ay01874k · Cited by 28
QCL–IR Spectroscopy for In-Line Monitoring of Proteins from Preparative Ion-Exchange Chromatography
Akhgar, C. K., Ebner, J., Spadiut, O., Schwaighofer, A., & Lendl, B. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c05191 · Cited by 28
Flow Water Proton NMR: In-Line Process Analytical Technology for Continuous Biomanufacturing
Taraban, M. B., Briggs, K. T., Merkel, P., & Yu, Y. B. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02622 · Cited by 25
Monitoring and control of E. coli cell integrity
Kastenhofer, J., Rajamanickam, V., Libiseller-Egger, J., & Spadiut, O. (2021) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2021.01.009 · Cited by 26
Panzitta, M., Calamassi, N., Sabatini, C., Grassi, M., Spagnoli, C., Vizzini, V., Ricchiuto, E., Venturini, A., Brogi, A., Font, J. B., et al. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120551 · Cited by 23
Generic Chemometric Models for Metabolite Concentration Prediction Based on Raman Spectra
Yousefi‐Darani, A., Paquet‐Durand, O., von Wrochem, A., Claßen, J., Traenkle, J., Mertens, M., Snelders, J., Chotteau, V., Mäkinen, M., Handl, A., et al. (2022) · Sensors · doi:10.3390/s22155581 · Cited by 24
Solid state of inhalable high dose powders
Adhikari, B. R., Gordon, K. C., & Das, S. C. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114468 · Cited by 23
Making next-generation biofuels and biocommodities a feasible reality
Boboescu, I. Z., Chemarin, F., Beigbeder, J., de Vasconcelos, B. R., Munirathinam, R., Ghislain, T., & Lavoie, J. (2019) · Current Opinion in Green and Sustainable Chemistry · doi:10.1016/j.cogsc.2019.07.005 · Cited by 25
Quantitative determinations using portable Raman spectroscopy
Navin, C. V., Tondepu, C., Toth, R., Lawson, L. S., & Rodriguez, J. D. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.12.020 · Cited by 22
Makki, A. A., Elderderi, S., Massot, V., Respaud, R., Byrne, H. J., Tauber, C., Bertrand, D., Mohammed, E., Chourpa, I., & Bonnier, F. (2021) · Talanta · doi:10.1016/j.talanta.2021.122137 · Cited by 22
Favaro, M., Kong, H., & Gottesman, R. (2023) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ad10d3 · Cited by 23
Fedick, P. W., Schrader, R., Ayrton, S. T., Pulliam, C. J., & Cooks, R. G. (2018) · Journal of Chemical Education · doi:10.1021/acs.jchemed.8b00725 · Cited by 21
Vibrational Spectroscopy for In Vitro Monitoring Stem Cell Differentiation
Ravera, F., Efeoğlu, E., & Byrne, H. J. (2020) · Molecules · doi:10.3390/molecules25235554 · Cited by 21
“Raman spectroscopy is already implemented in a number of areas as an online tool for process analytical technology (PAT) [143], and thus can also be employed for routine, automated monitoring of microbial or xenobiotic contamination in scaled up manufacturing processes.”
MethodRibeiro-Claro, P. J. A., Vaz, P. D., Nolasco, M. M., & Amado, A. M. (2018) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2018.06.073 · Cited by 21
Deep learning assisted Raman spectroscopy for rapid identification of 2D materials
Qi, Y., Hu, D., Zheng, M., Jiang, Y., & Chen, Y. P. (2024) · Applied Materials Today · doi:10.1016/j.apmt.2024.102499 · Cited by 24
“In the high-throughput or industrial applications, efficient analysis through Raman spectroscopy is crucial, particularly in areas such as quality control in product manufacturing, where rapid and accurate assessment of a large quantity of materials is necessary [17,18].”
Translational biophotonics with Raman imaging: clinical applications and beyond
Pence, I. J., & Evans, C. L. (2021) · The Analyst · doi:10.1039/d1an00954k · Cited by 21
Mishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“These include the need for large and representative datasets, optimal preprocessing techniques, handling environmental and noise sensitivities, high initial costs, and ensuring regulatory compliance [67].”
Machine learning-enhanced Raman spectroscopy for fast nanoplastic detection at low SNR
Lim, J., & Shin, D. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.138316 · Cited by 19
Metadata
- Authors
- Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2016-08-04
- Volume
- 409
- Issue
- 3
- Pages
- 637-649
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- PMC
- PMC5233728
- OpenAlex
- W2497039129
- Cited by
- 332
- References
- 103
- Citations by year
- 2026: 43 · 2025: 36 · 2024: 42 · 2023: 31 · 2022: 35 · 2021: 36 · 2020: 50 · 2019: 26 · 2018: 23 · 2017: 8 · 2016: 1
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR007080)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- Raman spectroscopy, process analytical technology, pharmaceutical manufacturing, bioprocessing, quality by design, continuous production, real-time release testing, statistical process control, in situ monitoring
- MeSH terms
- Biotechnology, Spectrum Analysis, Raman, Technology, Pharmaceutical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.