Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bioprocessing
Open accessThe DOI matches its Crossref record; 102 of the 103 references it cites were found in a registry or an index.
Abstract
Adoption of Quality by Design (QbD) principles, regulatory support of QbD, process analytical technology (PAT), and continuous manufacturing are major factors effecting new approaches to pharmaceutical manufacturing and bioprocessing. In this review, we highlight new technology developments, data analysis models, and applications of Raman spectroscopy, which have expanded the scope of Raman spectroscopy as a process analytical technology. Emerging technologies such as transmission and enhanced reflection Raman, and new approaches to using available technologies, expand the scope of Raman spectroscopy in pharmaceutical manufacturing, and now Raman spectroscopy is successfully integrated into real-time release testing, continuous manufacturing, and statistical process control. Since the last major review of Raman as a pharmaceutical PAT in 2010, many new Raman applications in bioprocessing have emerged. Exciting reports of in situ Raman spectroscopy in bioprocesses complement a growing scientific field of biological and biomedical Raman spectroscopy. Raman spectroscopy has made a positive impact as a process analytical and control tool for pharmaceutical manufacturing and bioprocessing, with demonstrated scientific and financial benefits throughout a product's lifecycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Schematic comparing variants of sample excitation (solid line) and signal collection [dashed line(s)] used in Raman spectroscopy in measuring turbid media. (a) Backscattered Raman is a commonly used geometry that uses a single site of excitation with collection of signal close (<1 mm) to the excitation. As applied to Raman microscopy, this approach is called epi-illumination as a single microscope objective is used to excite the sample and collect Raman signal. The sampling volume in backscattered Raman is generally small, both in the lateral and axial dimensions. Thus, backscattered Raman is a good approach for measuring a surface. (b) Overlapping a defocused or wide laser beam with multiple collection fibers in a backscattering-like geometry is called wide area Raman (also known as large volumetric or global illumination Raman). (c) Separating collection fibers from the sample excitation by a small distance (Δd = 1–6 mm) enables collection of diffusely scattered Raman photons, known as a spatially-offset Raman spectroscopy (SORS). (d) Transmission Raman collects Raman photons diffusely scattered through a sample. Wide area, spatially-offset Raman spectroscopy (SORS) and transmission Raman provides representative sampling in turbid media and enables collection of Raman signal from buried layers in a layered sample](https://figures.cochat.ai/paper-figures/e5a0bbbc329941ad87050f571a218a65/raman-spectroscopy-as-a-process-analytical-technology-for-pharmaceutical-figure-1.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the monitoring of intracellular and extracellular macromolecules in bioprocesses share many intrinsic similarities to yeast and bacteria bioprocesses, which have been extensively reviewed together due to these similarities [20,21,29].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [29]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Since our critical review of Raman spectroscopy in pharmaceutical manufacturing and bioprocessing in 2016 [18], we have seen developments in the use of Raman variants or enhancement strategies in basic science applications, expansion of in situ Raman measurements in upstream bioprocessing, and increasing compatibility of process Raman with process automation.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
The cited source says what the claim attributes to it.
In the citing paper
“Variations in the geometry of optical fibers and lenses within the probe can enable a variety of sampling options including backscattered, large volumetric, spatially offset Raman, and transmission Raman.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [18]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Production of recombinant protein therapeutics in cultivated mammalian cells
Wurm, F. M. (2004) · Nature Biotechnology · doi:10.1038/nbt1026 · Cited by 2,032 · cited 1×
“Production of protein therapeutics by mammalian cells is the most widely used bioprocess because of its ability to properly produce and fold a recombinant protein, with 60–70 % of biopharmaceuticals using this bioprocess [79, 80].”
BackgroundReference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 1×
“There are excellent reviews providing Raman spectra of biomolecules, complete with tables of band assignments [66, 67].”
BackgroundTissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352 · cited 1×
“Most cell and tissue spectroscopy is performed in the Btherapeutic^ near-infrared window (650– 1350 nm) because optical scattering is dominant and water absorption is at a minimum [14, 15].”
BackgroundBabuška, R. (1998) · International Series in Intelligent Technologies · doi:10.1007/978-94-011-4868-9 · Cited by 1,318
Biological Applications of Raman Spectroscopy
(2000) · Infrared and Raman Spectroscopy of Biological Materials · doi:10.1201/b16936-17 · Cited by 1,088
Sturgeon, R. (1988) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/0584-8547(88)80189-7 · Cited by 979
Vo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681 · cited 1×
“API or excipient particles and cellular organelles, such as mitochondria and nuclei, also strongly scatter light [16, 17].”
BackgroundMascia, S., Heider, P. L., Zhang, H., Lakerveld, R., Benyahia, B., Barton, P. I., Braatz, R. D., Cooney, C. L., Evans, J. M. B., Jamison, T. F., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305429 · Cited by 599
De Beer, T., Burggraeve, A., Fonteyne, M., Saerens, L., Remon, J. P., & Vervaet, C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.012 · Cited by 559
Autofluorescence of viable cultured mammalian cells.
Aubin, J. E. (1979) · Journal of Histochemistry & Cytochemistry · doi:10.1177/27.1.220325 · Cited by 555 · cited 1×
“flavins occur in visible wavelengths and the strong autofluorescence necessitates Raman measurements in the nearinfrared wavelengths (λ = 785 nm or 830 nm) even though the scattering efficiency is lower in the near-infrared compared with UVand visible wavelengths [12, 13].”
BackgroundInfrared and Raman Spectroscopy of Biological Materials
Gremlich, H.-U., & Yan, B. (2000) · CRC Press eBooks · doi:10.1201/b16936 · Cited by 531
Cellular autofluorescence--is it due to flavins?
Benson, R. C., Meyer, R. A., Zaruba, M. E., & McKhann, G. M. (1979) · Journal of Histochemistry & Cytochemistry · doi:10.1177/27.1.438504 · Cited by 414 · cited 1×
“flavins occur in visible wavelengths and the strong autofluorescence necessitates Raman measurements in the nearinfrared wavelengths (λ = 785 nm or 830 nm) even though the scattering efficiency is lower in the near-infrared compared with UVand visible wavelengths [12, 13].”
BackgroundCharacterisation and identification of bacteria using SERS
Jarvis, R. M., & Goodacre, R. (2008) · Chemical Society Reviews · doi:10.1039/b705973f · Cited by 371
Pharmaceutical applications of vibrational chemical imaging and chemometrics: A review
Gendrin, C., Roggo, Y., & Collet, C. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.08.014 · Cited by 350 · cited 1×
“Multivariate data analysis, or chemometrics, is widely used in biomedical Raman spectroscopy [34], pharmaceutical imaging [35], and process analytical technology [36].”
BackgroundAbu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
Self-citationBioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275 · cited 4×
“A recent study by Mehdizadeh et al. successfully demonstrated the use of a generic PCA/PLS model for bioreactors involving CHO cell lines [94].”
MethodInfluentialThree-dimensional computation of light scattering from cells
Dunn, A., & Richards-Kortum, R. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577313 · Cited by 275 · cited 1×
“API or excipient particles and cellular organelles, such as mitochondria and nuclei, also strongly scatter light [16, 17].”
BackgroundRaman spectroscopy for quantitative analysis of pharmaceutical solids
Strachan, C. J., Rades, T., Gordon, K. C., & Rantanen, J. (2007) · Journal of Pharmacy and Pharmacology · doi:10.1211/jpp.59.2.0005 · Cited by 240
Soft sensors in bioprocessing: A status report and recommendations
Luttmann, R., Bracewell, D. G., Cornelissen, G., Gernaey, K. V., Glassey, J., Hass, V. C., Kaiser, C., Preusse, C., Striedner, G., & Mandenius, C. (2012) · Biotechnology Journal · doi:10.1002/biot.201100506 · Cited by 238 · cited 1×
“Spectroscopic sensors are sometimes called Bsoft sensors^ in the bioprocessing literature because spectroscopic data is modeled in software programs and the models provide information akin to hardware sensors [87, 88].”
BackgroundReference database of Raman spectra of pharmaceutical excipients
de Veij, M., Vandenabeele, P., De Beer, T., Remon, J. P., & Moens, L. (2009) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2125 · Cited by 230 · cited 1×
“A comprehensive database of commonly used pharmaceutical excipients contains both the Raman spectrum and band assignments [48].”
BackgroundHandbook of Vibrational Spectroscopy
Meier, R. (2003) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/s1386-1425(02)00151-8 · Cited by 222
Histochemical analysis of biological tissues using Raman spectroscopy
Manoharan, R., Wang, Y., & Feld, M. S. (1996) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/0584-8539(95)01573-6 · Cited by 216
Industry Perspectives on Process Analytical Technology: Tools and Applications in API Development
Chanda, A., Daly, A. M., Foley, D. A., LaPack, M. A., Mukherjee, S., Orr, J. D., Reid, G. L., Thompson, D. R., & Ward, H. W. (2015) · Organic Process Research & Development · doi:10.1021/op400358b · Cited by 187
Bioprocess optimization and control: Application of hybrid modelling
Schubert, J., Simutis, R., Dors, M., Havlik, I., & Lübbert, A. (1994) · Journal of Biotechnology · doi:10.1016/0168-1656(94)90189-9 · Cited by 177
Craven, S., Whelan, J., & Glennon, B. (2014) · Journal of Process Control · doi:10.1016/j.jprocont.2014.02.007 · Cited by 171 · cited 4×
“Overall, the NMPC demonstrated good performance despite slight process– model mismatches, high measurement noise, unexpected occurrences, and long measurement intervals.”
MethodInfluentialHeider, P. L., Born, S. C., Basak, S., Benyahia, B., Lakerveld, R., Zhang, H., Hogan, R., Buchbinder, L., Wolfe, A., Mascia, S., et al. (2014) · Organic Process Research & Development · doi:10.1021/op400294z · Cited by 162
Spectral analysis and fingerprinting for biomedia characterisation
Pons, M.-N., Bonté, S. L., & Potier, O. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.03.028 · Cited by 161
Inverse Spatially Offset Raman Spectroscopy for Deep Noninvasive Probing of Turbid Media
Matousek, P. (2006) · Applied Spectroscopy · doi:10.1366/000370206778999102 · Cited by 160 · cited 1×
“cause Raman-scattered photons from subsurfaces are diffusely scattered afield from the illumination fiber [20, 21].”
BackgroundWhelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159 · cited 2×
“Later studies extend the capability of the technique by demonstrating cross-scale model transferability within development scale from 3 to 15 L [83], and from development scale (3, 200 L) to clinical manufacturing scale (2000 L) [84].”
BackgroundWang, F., Wachter, J. A., Antosz, F. J., & Berglund, K. A. (2000) · Organic Process Research & Development · doi:10.1021/op000210w · Cited by 148 · cited 1×
“In addition to identifying isolated polymorphic forms, mixtures of forms can be analyzed and quantified [6, 7].”
BackgroundBerry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Emerging Raman Applications and Techniques in Biomedical and Pharmaceutical Fields
Matousek, P., & Morris, M. D. (2010) · Biological and medical physics series · doi:10.1007/978-3-642-02649-2 · Cited by 138
Schulmerich, M. V., Dooley, K. A., Morris, M. D., Vanasse, T. M., & Goldstein, S. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2400233 · Cited by 136 · cited 1×
“cause Raman-scattered photons from subsurfaces are diffusely scattered afield from the illumination fiber [20, 21].”
BackgroundIn-Line Monitoring of Hydrate Formation during Wet Granulation Using Raman Spectroscopy
Wikström, H., Marsac, P. J., & Taylor, L. S. (2004) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20241 · Cited by 135
Berry, B. N., Dobrowsky, T. M., Timson, R. C., Kshirsagar, R., Ryll, T., & Wiltberger, K. (2016) · Biotechnology Progress · doi:10.1002/btpr.2205 · Cited by 135 · cited 2×
“enzymatic glycosylation of the target protein from 9 to 4 % [81].”
BackgroundRecent advances in the application of transmission Raman spectroscopy to pharmaceutical analysis
Buckley, K., & Matousek, P. (2010) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2010.10.029 · Cited by 134 · cited 1×
“Raman consistently report rapid API quantification with suitable prediction model error, and significant reduction of fluorescence or tablet coating signal [24, 25].”
BackgroundEngineering mammalian cells in bioprocessing – current achievements and future perspectives
Lim, Y., Wong, N. S. C., Lee, Y. Y., Ku, S. C. Y., Wong, D. C. F., & Yap, M. G. S. (2010) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20090363 · Cited by 133 · cited 2×
“Since 1986, an increased understanding of cell biology, gene transfer mechanisms, media composition, and process control has resulted in significant improvements to cell viability and titer [80].”
BackgroundHandbook of Raman Spectroscopy. From the Research Laboratory to the Process Line
Maes, G. (2002) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/s1386-1425(02)00113-0 · Cited by 130
Pharmaceutical Applications of Raman Spectroscopy
Šašić, S. (2007) · Wiley eBooks · doi:10.1002/9780470225882 · Cited by 128
Chemometrics in Process Analytical Chemistry
Miller, C. E. (2005) · Process Analytical Technology · doi:10.1002/9780470988459.ch8 · Cited by 125 · cited 1×
“Multivariate data analysis, or chemometrics, is widely used in biomedical Raman spectroscopy [34], pharmaceutical imaging [35], and process analytical technology [36].”
BackgroundPicard, A., Daniel, I., Montagnac, G., & Oger, P. (2006) · Extremophiles · doi:10.1007/s00792-006-0054-x · Cited by 123 · cited 1×
“A 2007 report of yeast fermentation used the 980 cm sulfate band as an internal standard [77].”
MethodHybrid modeling as a QbD/PAT tool in process development: an industrial E. coli case study
von Stosch, M., Hamelink, J., & Oliveira, R. (2016) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-016-1557-1 · Cited by 122
Noninvasive Raman tomographic imaging of canine bone tissue
Schulmerich, M. V., Cole, J. H., Dooley, K. A., Morris, M. D., Kreider, J. M., Goldstein, S. A., Srinivasan, S., & Pogue, B. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904940 · Cited by 119
Schulmerich, M. V., Finney, W. F., Fredricks, R. A., & Morris, M. D. (2006) · Applied Spectroscopy · doi:10.1366/000370206776023340 · Cited by 110
Generic Raman‐based calibration models enabling real‐time monitoring of cell culture bioreactors
Mehdizadeh, H., Lauri, D., Karry, K. M., Moshgbar, M., Procopio‐Melino, R., & Drapeau, D. (2015) · Biotechnology Progress · doi:10.1002/btpr.2079 · Cited by 108 · cited 1×
“successfully demonstrated the use of a generic PCA/PLS model for bioreactors involving CHO cell lines [94].”
MethodEliasson, C., Macleod, N. A., Jayes, L., Clarke, F. C., Hammond, S. V., Smith, M. R., & Matousek, P. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.01.013 · Cited by 107 · cited 2×
“Raman consistently report rapid API quantification with suitable prediction model error, and significant reduction of fluorescence or tablet coating signal [24, 25].”
BackgroundLeung, S., Winkle, R. F., Wootton, R. C. R., & deMello, A. J. (2004) · The Analyst · doi:10.1039/b412069h · Cited by 107 · cited 1×
“ic oxidation reactions [61] in a microfluidic reactor (or microreactor).”
BackgroundRaman spectroscopy of biological molecules: A review
Koenig, J. L. (1972) · Journal of Polymer Science Macromolecular Reviews · doi:10.1002/pol.1972.230060102 · Cited by 106 · cited 2×
“logical species examined by Raman spectroscopy [65, 66].”
BackgroundIn situ bioprocess monitoring of Escherichia coli bioreactions using Raman spectroscopy
Lee, H., Boccazzi, P., Gorret, N., Ram, R. J., & Sinskey, A. J. (2004) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2003.12.015 · Cited by 106 · cited 2×
“coli culture [90], confocal Raman microscopy of media [91], and yeast fermentation [78].”
BackgroundPAT-tools for process control in pharmaceutical film coating applications
Knop, K., & Kleinebudde, P. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.01.062 · Cited by 105 · cited 1×
“Raman has demonstrated value as an in-line PAT for batch or continuous tablet coating processes, providing both process control and real-time coating release [55, 56] and capable of meeting ICH Q2 guidelines for an active coating process [4].”
BackgroundMonitoring a bioprocess for ethanol production using FT-MIR and FT-Raman spectroscopy
Sivakesava, S., Irudayaraj, J., & Demirci, A. (2001) · Journal of Industrial Microbiology and Biotechnology · doi:10.1038/sj.jim.7000124 · Cited by 104
Hédoux, A., Guinet, Y., & Descamps, M. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.01.031 · Cited by 101
Non‐invasive probing of pharmaceutical capsules using transmission Raman spectroscopy
Matousek, P., & Parker, A. W. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1688 · Cited by 96 · cited 1×
“cial layers, rapidly providing a bulk Raman measurement of a pharmaceutical formulation [25, 26].”
BackgroundRapid monitoring of antibiotics using Raman and surface enhanced Raman spectroscopy
Clarke, S., Littleford, R. E., Smith, W. E., & Goodacre, R. (2005) · The Analyst · doi:10.1039/b502540k · Cited by 94
Shaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84 · cited 1×
“demonstrated that a multivariate model resulted in the least amount of prediction error, and was the first to show that a model developed for one process could be successfully transferred as long as the same process was used [93].”
Prediction of quality attributes of continuously produced granules using complementary pat tools
Fonteyne, M., Soares, S. O., Vercruysse, J., Peeters, E., Burggraeve, A., Vervaet, C., Remon, J. P., Sandler, N., & Beer, T. D. (2012) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2012.07.017 · Cited by 76 · cited 1×
“reported successful prediction of residual moisture content using on-line Raman and near-infrared and prediction of granule flowability using photometric imaging during a continuous granulation production [64].”
MethodQuantitative polymorph contaminant analysis in tablets using Raman and near infra-red spectroscopies
Hennigan, M. C., & Ryder, A. G. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.10.002 · Cited by 75 · cited 1×
“Low levels of polymorph impurities were examined in the laboratory on a model tablet using NIR, backscattered, and transmission Raman spectroscopies [52].”
MethodSimone, E., Saleemi, A. N., & Nagy, Z. K. (2014) · Organic Process Research & Development · doi:10.1021/op5000122 · Cited by 75 · cited 1×
“An example shows how Raman, NIR, FBRM, UV/Vis, and particle vision were integrated into a single intelligent decision support system [46].”
BackgroundWide area coverage Raman spectroscopy for reliable quantitative analysis and its applications
Shin, K., & Chung, H. (2013) · The Analyst · doi:10.1039/c3an36843b · Cited by 70
On‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70 · cited 1×
“Another early in-line Raman study reported direct measurement of carotenoid production by Phaffia rhodozyma, and the Raman data were used to determine an optimal feeding strategy [76].”
MethodQuantitative monitoring of yeast fermentation using Raman spectroscopy
Iversen, J. A., Berg, R. W., & Ahring, B. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7897-2 · Cited by 70 · cited 1×
“coli culture [90], confocal Raman microscopy of media [91], and yeast fermentation [78].”
BackgroundPerformance monitoring of a mammalian cell based bioprocess using Raman spectroscopy
Li, B., Ray, B. H., Leister, K. J., & Ryder, A. G. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.058 · Cited by 67 · cited 1×
“Off-line Raman spectroscopy of CHO fed-batch bioprocess fresh and spent media enabled glycoprotein yield prediction [86].”
BackgroundFeasibility of Raman spectroscopy as PAT tool in active coating
Müller, J., Knop, K., Thies, J., Uerpmann, C., & Kleinebudde, P. (2010) · Drug Development and Industrial Pharmacy · doi:10.3109/03639040903225109 · Cited by 66 · cited 1×
“Raman has demonstrated value as an in-line PAT for batch or continuous tablet coating processes, providing both process control and real-time coating release [55, 56] and capable of meeting ICH Q2 guidelines for an active coating process [4].”
BackgroundSelf-citationDeep Noninvasive Raman Spectroscopy of Turbid Media
Macleod, N. A., & Matousek, P. (2008) · Applied Spectroscopy · doi:10.1366/000370208786401527 · Cited by 65
Raman Signal Enhancement in Deep Spectroscopy of Turbid Media
Matousek, P. (2007) · Applied Spectroscopy · doi:10.1366/000370207781540178 · Cited by 62 · cited 1×
“This approach is effective because elastically scattered photons can be reflected back into the sample and possibly undergo inelastic scattering [30].”
BackgroundNext-generation Raman tomography instrument for non-invasive in vivo bone imaging
Demers, J.-L. H., Esmonde-White, F. W. L., Esmonde-White, K. A., Morris, M. D., & Pogue, B. W. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.000793 · Cited by 60
Self-citationUrakawa, A., Trachsel, F., von Rohr, P. R., & Baiker, A. (2008) · The Analyst · doi:10.1039/b808984c · Cited by 59
Raman spectroscopy of calcified tissue
Walton, A. G., Deveney, M. J., & Koenig, J. L. (1970) · Calcified Tissue International · doi:10.1007/bf02196195 · Cited by 57 · cited 1×
“logical species examined by Raman spectroscopy [65, 66].”
(2006) · Chemical & Engineering News · doi:10.1021/cen-v084n028.ifc · Cited by 53
Baronsky-Probst, J., Möltgen, C.-V., Kessler, W., & Kessler, R. W. (2015) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2015.09.010 · Cited by 52 · cited 1×
“where off-line Raman imaging was used to measure API distribution in a hot melt extrusion [54].”
MethodAazam, E. S., & Zaheer, Z. (2016) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-016-1539-3 · Cited by 50
Soft x-ray scanning transmission spectromicroscopy
Cosmidis, J., & Benzerara, K. (2014) · CRC Press eBooks · doi:10.1201/b16621-8 · Cited by 48
Abu-Absi, N. R., Martel, R. P., Lanza, A. M., Clements, S. J., Borys, M. C., & Li, Z. J. (2014) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.14.24 · Cited by 47 · cited 1×
“Spectroscopic sensors are sometimes called Bsoft sensors^ in the bioprocessing literature because spectroscopic data is modeled in software programs and the models provide information akin to hardware sensors [87, 88].”
BackgroundCalvet, A., & Ryder, A. G. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.06.021 · Cited by 45
The Direct Analysis of Fermentation Products by Raman Spectroscopy
Shope, T. B., Vickers, T. J., & Mann, C. K. (1987) · Applied Spectroscopy · doi:10.1366/0003702874448373 · Cited by 42
Li, B., Calvet, A., Casamayou-Boucau, Y., Morris, C., & Ryder, A. G. (2015) · Analytical Chemistry · doi:10.1021/ac504776m · Cited by 41
Everall, N. J., Priestnall, I. M., Dallin, P. H., Andrews, J., Lewis, I. R., Davis, K. L., Owen, H., & George, M. W. (2010) · Applied Spectroscopy · doi:10.1366/000370210791211646 · Cited by 38 · cited 1×
“Raman were modeled using Monte Carlo and experimental validation of the model [22, 31].”
MethodSelf-citationPrusinkiewicz, M. A., Farazkhorasani, F., Dynes, J. J., Wang, J., Gough, K. M., & Kaminskyj, S. G. W. (2012) · The Analyst · doi:10.1039/c2an35620a · Cited by 32
Jestel, N. L. (2005) · Wiley eBooks · doi:10.1002/9780470988459.ch5 · Cited by 29 · cited 1×
“Two reviews provide a comprehensive list [38, 39].”
Müller, J., Knop, K., Wirges, M., & Kleinebudde, P. (2010) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2010.06.016 · Cited by 29 · cited 1×
“Raman has demonstrated value as an in-line PAT for batch or continuous tablet coating processes, providing both process control and real-time coating release [55, 56] and capable of meeting ICH Q2 guidelines for an active coating process [4].”
BackgroundFeedback Control of Oximation Reaction by Inline Raman Spectroscopy
Csontos, I., Pataki, H., Farkas, A., Bata, H., Vajna, B., Nagy, Z. K., Keglevich, G., & Marosi, G. (2014) · Organic Process Research & Development · doi:10.1021/op500015d · Cited by 29 · cited 1×
“Another illustrative example shows Raman-based control of a model exothermic oximation reaction, which successfully controlled accumulation of an unstable intermediate [47].”
BackgroundQuantitative Raman spectroscopy in turbid matter: reflection or transmission mode?
Oelkrug, D., Ostertag, E., & Kessler, R. W. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-6719-2 · Cited by 26 · cited 2×
“provides a bulk measurement similar to transmission Raman [31, 32] and improves selectivity in thin film measurements in”
BackgroundMethodChemometric Methods for Biomedical Raman Spectroscopy and Imaging
Reddy, R. K., & Bhargava, R. (2009) · Biological and medical physics series · doi:10.1007/978-3-642-02649-2_8 · Cited by 25 · cited 1×
“Multivariate data analysis, or chemometrics, is widely used in biomedical Raman spectroscopy [34], pharmaceutical imaging [35], and process analytical technology [36].”
BackgroundRaman spectroscopy of complex defined media: biopharmaceutical applications
Singh, G., Goh, S., Canzoneri, M., & Ram, R. J. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4686 · Cited by 24 · cited 2×
“coli culture [90], confocal Raman microscopy of media [91], and yeast fermentation [78].”
BackgroundQuantitative Analysis of Pharmaceutical Bilayer Tablets Using Transmission Raman Spectroscopy
Zhang, Y., & McGeorge, G. (2015) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-015-9223-8 · Cited by 23 · cited 1×
“Application of transmission Raman to quantify API in a bilayer tablet was reported by Zhang and McGeorge [33].”
MethodGomy, C., Jouan, M. D., & Dao, N. Q. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85279-4 · Cited by 23 · cited 1×
“Other reports include off-line Raman measurements of glucose, glutamine, lactic acid, and ammonia drawn from a cell culture bioreactor [73], or in-line Raman measurements of ethanol, glucose, and fructose of Saccharomyces cerevisiae during alcoholic fermentation [74].”
BackgroundPathology by Infrared and R aman Spectroscopy
Jackson, M., & Mantsch, H. H. (2001) · Wiley eBooks · doi:10.1002/0470027320.s8101 · Cited by 20
Raman measurement of glucose in bioreactor materials:
Xu, Y., Ford, J. F., Mann, C. K., Vickers, T. J., Brackett, J. M., Cousineau, K. L., & Robey, W. G. (1997) · SPIE Proceedings · doi:10.1117/12.275527 · Cited by 18 · cited 1×
“Other reports include off-line Raman measurements of glucose, glutamine, lactic acid, and ammonia drawn from a cell culture bioreactor [73], or in-line Raman measurements of ethanol, glucose, and fructose of Saccharomyces cerevisiae during alcoholic fermentation [74].”
BackgroundReal-Time Process Analytical Technology Assurance for Flow Synthesis of Oligonucleotides
Rydzak, J. W., White, D. E., Airiau, C. Y., Sterbenz, J. T., York, B. D., Clancy, D. J., & Dai, Q. (2014) · Organic Process Research & Development · doi:10.1021/op500035j · Cited by 18 · cited 1×
“tivariate statistical process control (MSPC) to provide realtime quality assurance for flow synthesis of an oligonucleotide [63].”
BackgroundIntegration of Continuous Flow Reactors and Online Raman Spectroscopy for Process Optimization
Roberto, M. F., Dearing, T. I., Martin, S., & Marquardt, B. J. (2012) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-012-9128-8 · Cited by 17
Quality by Design Approaches to Formulation Robustness—An Antibody Case Study
Wurth, C., Demeule, B., Mahler, H., & Adler, M. (2016) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.02.013 · Cited by 17 · cited 1×
“Inhouse preparation of excipients or biopharmaceutical formulations may require its own risk-based manufacturing approach [49].”
BackgroundSinfield, J. V., & Monwuba, C. K. (2014) · Applied Spectroscopy · doi:10.1366/13-07292 · Cited by 16
A PAT-based qualification of pharmaceutical excipients produced by batch or continuous processing
Hertrampf, A., Müller, H., de Menezes, J. C., & Herdling, T. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.05.012 · Cited by 15 · cited 3×
“The manufacturing process may require additional supplier qualification, especially if an excipient’s material attribute is found to be a critical process parameter [41].”
BackgroundMethodInfluentialLyndgaard, L. B., Spångberg, R., Gilmour, C., Lyndgaard, C. B., & van den Berg, F. W. J. (2014) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4433 · Cited by 15
In situ Monitoring of a Heterogeneous Etherification Reaction Using Quantitative Raman Spectroscopy
Hart, R., Pedge, N. I., Steven, A., & Sutcliffe, K. (2014) · Organic Process Research & Development · doi:10.1021/op500027w · Cited by 15 · cited 2×
“published a comprehensive paper on the many considerations in using a PAT for API synthesis [40].”
BackgroundOn‐Line Applications in the Pharmaceutical Industry
Doherty, S., & Kettler, C. N. (2005) · Wiley eBooks · doi:10.1002/9780470988459.ch9 · Cited by 13 · cited 1×
“In-process Raman for reaction monitoring and analysis during unit operations have been reviewed [6, 45].”
Raman Spectroscopy: A Strategic Tool in the Process Analytical Technology Toolbox
Johansson, J., Claybourn, M., & Folestad, S. (2009) · Biological and medical physics series · doi:10.1007/978-3-642-02649-2_10 · Cited by 10 · cited 1×
“able choice for in situ bioprocess monitoring but there were a limited number of published reports, and literature reviews in 2004 and 2010 reflected that understanding [10, 71].”
BackgroundLarkin, P. J., Santangelo, M., & Šašić, S. (2012) · Applied Spectroscopy · doi:10.1366/12-06677 · Cited by 9 · cited 1×
“provides a bulk measurement similar to transmission Raman [31, 32] and improves selectivity in thin film measurements in”
Background2014: The PAT Trend Is Still Bullish
Simon, L. L. (2015) · Organic Process Research & Development · doi:10.1021/op500388t · Cited by 9
Raman Spectroscopy for Monitoring Real‐Time Processes in the Pharmaceutical Industry
Davis, K. L., Kemper, M. S., & Lewis, I. R. (2007) · Wiley eBooks · doi:10.1002/9780470225882.ch5 · Cited by 7 · cited 2×
“In-process Raman for reaction monitoring and analysis during unit operations have been reviewed [6, 45].”
BackgroundSelf-citationWang, Z., Yang, H., Ding, H., Lu, G., Jiang, H., & Bi, X. (2015) · Electronics Letters · doi:10.1049/el.2015.2449 · Cited by 4
Research works printed but not linked: 4
- Slater JB Tedesco TM Fairchild RC Lewis IR Lewis IR Edwards HGM Raman spectrometry and its adaptation to the industrial environment Handbook of Raman spectroscopy: from the research laboratory to the process line 2001 New York Marcel-Dekker
- Kourti T Davis B The business benefits of quality by design (QbD) Pharm Eng 2012 32 4 1 10
- Moore CMV Regulatory perspective on real time release testing (RTRT) 2011 Washington DC Proceedings of the AAPS Annual Meeting
- Gervasio GJ Pelletier MJ On-line Raman analysis of PCl3 reactor material J Process Anal Chem 1997 3 1/2 7 11
Cited by
Tripathi, N. K., & Shrivastava, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00420 · Cited by 575
“, lying outside the bioreactor, requiring an automatic sampling interface to the bioreactor that enables a sample to be drawn and delivered to the analyzer for bioreactor content analysis), at-line (manual sampling and analysis), and in-line (directly connected to the bioreactor) monitoring of samples, are near-infrar…”
InfluentialZhang, W., Ma, J., & Sun, D.-W. (2021) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2020.1828814 · Cited by 220
“Micro-Raman spectroscopy employs an epi-illumination configuration, whose microscope objective delivers not only focused laser light to the microscope but also collects Raman-scattered photons (Esmonde-White et al. 2017).”
BackgroundDeidda, R., Sacre, P.-Y., Clavaud, M., Coïc, L., Avohou, H., Hubert, P., & Ziemons, E. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.02.035 · Cited by 193
Wasalathanthri, D. P., Rehmann, M. S., Song, Y., Gu, Y., Mi, L., Shao, C., Chemmalil, L., Lee, J., Ghose, S., Borys, M. C., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27461 · Cited by 177
Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160
“Inline monitoring has shown utility for collecting continuous and instantaneous data (when compared to the long duration of a typical mammalian cell culture, ten or more days), and both forms of bioprocesses monitoring have demonstrated that they can provide useful information on the scale-up of fed-batch processes (t…”
Metadata
- Authors
- Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2016-08-04
- Volume
- 409
- Issue
- 3
- Pages
- 637-649
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- PMC
- PMC5233728
- OpenAlex
- W2497039129
- Cited by
- 332
- References
- 103
- Citations by year
- 2026: 43 · 2025: 36 · 2024: 42 · 2023: 31 · 2022: 35 · 2021: 36 · 2020: 50 · 2019: 26 · 2018: 23 · 2017: 8 · 2016: 1
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR007080)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- Raman spectroscopy, process analytical technology, pharmaceutical manufacturing, bioprocessing, quality by design, continuous production, real-time release testing, statistical process control, in situ monitoring
- MeSH terms
- Biotechnology, Spectrum Analysis, Raman, Technology, Pharmaceutical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.