The DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Design of a cybernetic hand for perception and action
Open accessAbstract
Strong motivation for developing new prosthetic hand devices is provided by the fact that low functionality and controllability-in addition to poor cosmetic appearance-are the most important reasons why amputees do not regularly use their prosthetic hands. This paper presents the design of the CyberHand, a cybernetic anthropomorphic hand intended to provide amputees with functional hand replacement. Its design was bio-inspired in terms of its modular architecture, its physical appearance, kinematics, sensorization, and actuation, and its multilevel control system. Its underactuated mechanisms allow separate control of each digit as well as thumb-finger opposition and, accordingly, can generate a multitude of grasps. Its sensory system was designed to provide proprioceptive information as well as to emulate fundamental functional properties of human tactile mechanoreceptors of specific importance for grasp-and-hold tasks. The CyberHand control system presumes just a few efferent and afferent channels and was divided in two main layers: a high-level control that interprets the user's intention (grasp selection and required force level) and can provide pertinent sensory feedback and a low-level control responsible for actuating specific grasps and applying the desired total force by taking advantage of the intelligent mechanics. The grasps made available by the high-level controller include those fundamental for activities of daily living: cylindrical, spherical, tridigital (tripod), and lateral grasps. The modular and flexible design of the CyberHand makes it suitable for incremental development of sensorization, interfacing, and control strategies and, as such, it will be a useful tool not only for clinical research but also for addressing neuroscientific hypotheses regarding sensorimotor control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Central invasive neural interfaces have been used by many groups (Carmena et al. 2003; Serruya et al. 2002; Musallam et al. 2004; Taylor et al. 2002; Hochberg et al. 2006; Schwartz 2004) to extract motor information related to reaching movements.”
MethodLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Johansson, R. S., & Westling, G. (1984) · Experimental Brain Research · doi:10.1007/bf00237997 · Cited by 1,703
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
Robot Hands and the Mechanics of Manipulation
Mason, M. T., Salisbury, J. K., & Parker, J. K. (1989) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3153010 · Cited by 911
Johansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“Finally, PNS invasive interfaces can be used to discriminate different neural signals (Navarro et al. 2005; Dhillon et al. 2004; Citi et al. 2006).”
BackgroundSelf-citationElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Biologically inspired robots: snake-like locomotors and manipulators
(1994) · Choice Reviews Online · doi:10.5860/choice.32-0954 · Cited by 819
Review Article Tactile sensing for mechatronics—a state of the art survey
Lee, M. H., & Nicholls, H. R. (1999) · Mechatronics · doi:10.1016/s0957-4158(98)00045-2 · Cited by 704
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Cortical Activity in Precision- Versus Power-Grip Tasks: An fMRI Study
Ehrsson, H. H., Fagergren, A., Jonsson, T., Westling, G., Johansson, R. S., & Forssberg, H. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.528 · Cited by 619
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Self-citationControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Self-citationSchwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
The development of soft gripper for the versatile robot hand
Hirose, S., & Umetani, Y. (1978) · Mechanism and Machine Theory · doi:10.1016/0094-114x(78)90059-9 · Cited by 480
Gordon, A. M., Westling, G., Cole, K. J., & Johansson, R. S. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.6.1789 · Cited by 435
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Development of human precision grip I: Basic coordination of force
Forssberg, H., Eliasson, A. C., Kinoshita, H., Johansson, R. S., & Westling, G. (1991) · Experimental Brain Research · doi:10.1007/bf00229422 · Cited by 369
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1×
“Finally, PNS invasive interfaces can be used to discriminate different neural signals (Navarro et al. 2005; Dhillon et al. 2004; Citi et al. 2006).”
BackgroundPatterns of Hand Motion during Grasping and the Influence of Sensory Guidance
Santello, M., Flanders, M., & Soechting, J. F. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-04-01426.2002 · Cited by 354
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Vision and Action: The Control of Grasping
(2000) · Industrial Robot: An International Journal · doi:10.1108/ir.2000.04927cae.003 · Cited by 335
Nerve injury and repair – a challenge to the plastic brain
Lundborg, G. (2003) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2003.03027.x · Cited by 327
Robotic Grasping and Fine Manipulation
Cutkosky, M. R. (1985) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-1-4684-6891-5 · Cited by 325
Visual and Somatosensory Information about Object Shape Control Manipulative Fingertip Forces
Jenmalm, P., & Johansson, R. S. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-11-04486.1997 · Cited by 291
Tactile sensing in intelligent robotic manipulation – a review
Tegin, J., & Wikander, J. (2005) · Industrial Robot: An International Journal · doi:10.1108/01439910510573318 · Cited by 290
Simulation and design of underactuated mechanical hands
Laliberté, T., & Gosselin, C. M. (1998) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(97)00020-7 · Cited by 272
Sensory Control of Dexterous Manipulation in Humans
Johansson, R. S. (1996) · Hand and Brain · doi:10.1016/b978-012759440-8/50025-6 · Cited by 255
The SPRING Hand: Development of a Self-Adaptive Prosthesis for Restoring Natural Grasping
Carrozza, M. C., Suppo, C., Sebastiani, F., Massa, B., Vecchi, F., Lazzarini, R., Cutkosky, M. R., & Dario, P. (2004) · Autonomous Robots · doi:10.1023/b:auro.0000016863.48502.98 · Cited by 255
Self-citationIndependent control of human finger‐tip forces at individual digits during precision lifting.
Edin, B. B., Westling, G., & Johansson, R. S. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019142 · Cited by 237
Self-citationHand and brain: the neurophysiology and psychology of hand movements
(1997) · Choice Reviews Online · doi:10.5860/choice.34-2781 · Cited by 228
Eliasson, A.-C., Forssberg, H., Ikuta, K., Apel, I., Westling, G., & Johansson, R. (1995) · Experimental Brain Research · doi:10.1007/bf00231065 · Cited by 225
Human Limbs and Their Substitutes
(1955) · Physical Therapy · doi:10.1093/ptj/35.5.276a · Cited by 201
Forssberg, H., Kinoshita, H., Eliasson, A. C., Johansson, R. S., Westling, G., & Gordon, A. M. (1992) · Experimental Brain Research · doi:10.1007/bf00227253 · Cited by 193
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Design and fabrication of a hybrid silicon three-axial force sensor for biomechanical applications
Beccai, L., Roccella, S., Arena, A., Valvo, F., Valdastri, P., Menciassi, A., Carrozza, M. C., & Dario, P. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.01.007 · Cited by 183
Self-citationDevelopment of a lightweight and adaptable multiple-axis hand prosthesis
Light, C. M., & Chappell, P. H. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00017-0 · Cited by 178
Myoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
15 years of BCI research at graz university of technology: current projects
Pfurtscheller, G., Muller-Putz, G. R., Schlogl, A., Graimann, B., Scherer, R., Leeb, R., Brunner, C., Keinrath, C., Lee, F., Townsend, G., et al. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875528 · Cited by 164
Intelligent multifunction myoelectric control of hand prostheses
Light, C. M., Chappell, P. H., Hudgins, B., & Engelhart, K. (2002) · Journal of Medical Engineering & Technology · doi:10.1080/03091900210142459 · Cited by 164
Control of Fingertip Forces in Multidigit Manipulation
Flanagan, J. R., Burstedt, M. K. O., & Johansson, R. S. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1706 · Cited by 149
Myoelectric prostheses. A long-term follow-up and a study of the use of alternate prostheses.
Silcox, D. H., Rooks, M. D., Vogel, R., & Fleming, L. L. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199312000-00007 · Cited by 144
The neurochip BCI: towards a neural prosthesis for upper limb function
Jackson, A., Moritz, C. T., Mavoori, J., Lucas, T. H., & Fetz, E. E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875547 · Cited by 139
Advances in tactile sensors design/manufacturing and its impact on robotics applications – a review
Dargahi, J., & Najarian, S. (2005) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439910510593965 · Cited by 132
MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control
Kyberd, P., Holland, O. E., Chappell, P. H., Smith, S., Tregidgo, R., Bagwell, P. J., & Snaith, M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.372895 · Cited by 121
The development of a novel prosthetic hand-ongoing research and preliminary results
Carrozza, M. C., Massa, B., Micera, S., Lazzarini, R., Zecca, M., & Dario, P. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011247 · Cited by 120
Self-citationHuman limbs and their substitutes
(1956) · The American Journal of Surgery · doi:10.1016/0002-9610(56)90428-7 · Cited by 119
Progress in the development of a multifunctional hand prosthesis
Pylatiuk, C., Mounier, S., Kargov, A., Schulz, S., & Bretthauer, G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404187 · Cited by 94
Micera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Self-citationSENSORY SUBSTITUTION IN PROSTHETICS
Lundborg, G., & Rosén, B. (2001) · Hand Clinics · doi:10.1016/s0749-0712(21)00526-6 · Cited by 88
Rosén, B., Lundborg, G., Dahlin, L. B., HOLMBERG, J., & Karlson, B. (1994) · Journal of Hand Surgery (European Volume) · doi:10.1016/0266-7681(94)90209-7 · Cited by 83
Hybrid Bionic Systems for the Replacement of Hand Function
Micera, S., Carrozza, M. C., Beccai, L., Vecchi, F., & Dario, P. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.881294 · Cited by 73
Self-citationMicera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58 · cited 2×
“2006), as well as toward the development of novel signal processing algorithms (Micera et al. 2001; Cavallaro et al. 2003; Tesfayesus and Durand 2006).”
BackgroundThick-film force and slip sensors for a prosthetic hand
Cranny, A., Cotton, D. P. J., Chappell, P. H., Beeby, S., & White, N. M. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.02.015 · Cited by 53
Implantable telemeter for long-term electroneurographic recordings in animals and humans
Donaldson, N., Zhou, L., Perkins, T. A., Munih, M., Haugland, M. K., & Sinkjær, T. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02349973 · Cited by 50
EEG based BCI-towards a better control. Brain-computer interface research at aalborg university
Nielsen, K. D., Cabrera, A. F., & do Nascimento, O. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875529 · Cited by 48
Closed-loop controller for a bio-inspired multi-fingered underactuated prosthesis
Cipriani, C., Zaccone, F., Stellin, G., Beccai, L., Cappiello, G., Carrozza, M. C., & Dario, P. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642016 · Cited by 46
Self-citationCavallaro, E., Micera, S., Dario, P., Jensen, W., & Sinkjaer, T. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816075 · Cited by 44 · cited 2×
“2006), as well as toward the development of novel signal processing algorithms (Micera et al. 2001; Cavallaro et al. 2003; Tesfayesus and Durand 2006).”
BackgroundSelf-citationTwo Multiarticulated Hydraulic Hand Prostheses
Pylatiuk, C., Schulz, S., Kargov, A., & Bretthauer, G. (2004) · Artificial Organs · doi:10.1111/j.1525-1594.2004.00014.x · Cited by 38
Edin, B. B., Beccai, L., Ascari, L., Roccella, S., Cabibihan, J., & Carrozza, M. C. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1641897 · Cited by 37
Self-citationArieta, A. H., Yokoi, H., Arai, T., & Yu, W. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616097 · Cited by 37
Cognitive feedback for use with FES upper extremity neuroprostheses
Riso, R. R., Ignagni, A. R., & Keith, M. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68206 · Cited by 35
Zecca, M., Cappiello, G., Sebastiani, F., Roccella, S., Vecchi, F., Carrozza, M. C., & Dario, A. P. (2006) · Springer eBooks · doi:10.1007/10946978_15 · Cited by 31
Self-citationAn integrated miniature fingertip sensor
Dario, P., Lazzarini, R., Magni, R., & Oh, S. (2002) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.1996.563407 · Cited by 23
Characterization of tfLIFE Neural Response for the Control of a Cybernetic Hand
Citi, L., Carpaneto, J., Yoshida, K., Hoffmann, K. ‐., Koch, K. P., Dario, P., & Micera, S. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639134 · Cited by 21
Self-citationSensory feedback system using interferential current for EMG prosthetic hand
Sasaki, Y. C., Nakayama, Y., & Yoshida, M. (2002) · doi:10.1109/iembs.2002.1053345 · Cited by 14
Blind source separation of neural recordings and control signals
Tesfayesus, W., & Durand, D. M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260400 · Cited by 12
EMG-control of prostheses by switch signals: extraction and classification of features
Reischl, M., Gröll, L., & Mikut, R. (2005) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2004.1398279 · Cited by 11
Johansson, R. S., & Edin, B. B. (1992) · Cited by 6
Self-citationMicera, S., Carpaneto, J., Umiltà, M. A., Rochat, M. J., Escola, L., Gallese, V., Carrozza, M. C., Krueger, J., Rizzolatti, G., & Dario, P. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419572 · Cited by 4
Self-citation
Cited by
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationOptoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
Self-citationHand Posture Subspaces for Dexterous Robotic Grasping
Ciocarlie, M. T., & Allen, P. K. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909105606 · Cited by 409
Metadata
- Authors
- Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C.
- Venue
- Biological Cybernetics
- Published
- 2006-12
- Volume
- 95
- Issue
- 6
- Pages
- 629-44
- ISSN
- 0340-1200 (ISSN-L)
- 1432-0770
- OpenAlex
- W1990718137
- Cited by
- 341
- References
- 79
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.