Design of a cybernetic hand for perception and action
Open accessThe DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
Strong motivation for developing new prosthetic hand devices is provided by the fact that low functionality and controllability-in addition to poor cosmetic appearance-are the most important reasons why amputees do not regularly use their prosthetic hands. This paper presents the design of the CyberHand, a cybernetic anthropomorphic hand intended to provide amputees with functional hand replacement. Its design was bio-inspired in terms of its modular architecture, its physical appearance, kinematics, sensorization, and actuation, and its multilevel control system. Its underactuated mechanisms allow separate control of each digit as well as thumb-finger opposition and, accordingly, can generate a multitude of grasps. Its sensory system was designed to provide proprioceptive information as well as to emulate fundamental functional properties of human tactile mechanoreceptors of specific importance for grasp-and-hold tasks. The CyberHand control system presumes just a few efferent and afferent channels and was divided in two main layers: a high-level control that interprets the user's intention (grasp selection and required force level) and can provide pertinent sensory feedback and a low-level control responsible for actuating specific grasps and applying the desired total force by taking advantage of the intelligent mechanics. The grasps made available by the high-level controller include those fundamental for activities of daily living: cylindrical, spherical, tridigital (tripod), and lateral grasps. The modular and flexible design of the CyberHand makes it suitable for incremental development of sensorization, interfacing, and control strategies and, as such, it will be a useful tool not only for clinical research but also for addressing neuroscientific hypotheses regarding sensorimotor control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Central invasive neural interfaces have been used by many groups (Carmena et al. 2003; Serruya et al. 2002; Musallam et al. 2004; Taylor et al. 2002; Hochberg et al. 2006; Schwartz 2004) to extract motor information related to reaching movements.”
MethodLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Johansson, R. S., & Westling, G. (1984) · Experimental Brain Research · doi:10.1007/bf00237997 · Cited by 1,703
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
Cited by
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationOptoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
Self-citationHand Posture Subspaces for Dexterous Robotic Grasping
Ciocarlie, M. T., & Allen, P. K. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909105606 · Cited by 409
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Self-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationUpper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343
Somatosensory actuator based on stretchable conductive photothermally responsive hydrogel
Zhao, Y., Lo, C.-Y., Ruan, L., Pi, C.-H., Kim, C., Alsaid, Y., Frenkel, I., Rico, R., Tsao, T.-C., & He, X. (2021) · Science Robotics · doi:10.1126/scirobotics.abd5483 · Cited by 317
Tactile sensing in intelligent robotic manipulation – a review
Tegin, J., & Wikander, J. (2005) · Industrial Robot: An International Journal · doi:10.1108/01439910510573318 · Cited by 290
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Self-citationChiri, A., Vitiello, N., Giovacchini, F., Roccella, S., Vecchi, F., & Carrozza, M. C. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2144614 · Cited by 254
Self-citationOnline Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
“It is a right hand, with five underactuated fingers driven by six motors: five of which are employed for the independent flexion/extension of the fingers, and one for the abduction/adduction of the thumb (detailed description in [ 27 ]).”
MethodSelf-citationMechanisms of the Anatomically Correct Testbed Hand
Deshpande, A. D., Xu, Z., Weghe, M. J. V., Brown, B. H., Ko, J., Chang, L. Y., Wilkinson, D. D., Bidic, S. M., & Matsuoka, Y. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2166801 · Cited by 170
“Examples of tendon-driven hands include: the Okada Hand [52], the Utah/MIT Hand [30], [36], [62], the DLR II Hand [44], the UB Hand 3 [46], the Vanderbilt Hand [22], the CyberHand [15], the Karlsruhe Hand [37], [65], the smart motor and air muscle Shadow Hands [59], and the Keio Hand [74].”
BackgroundMicera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Self-citationMicera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100
“The prosthetic hand used was a stand-alone version of the CyberHand prototype, already employed in several research scenarios [32].”
MethodSelf-citationOddo, C. M., Beccai, L., Wessberg, J., Wasling, H. B., Mattioli, F., & Carrozza, M. C. (2011) · Sensors · doi:10.3390/s110605596 · Cited by 49
“The fingertip was designed for application to distal phalanxes of robotic hands being appropriate for grasping and manipulation tasks in anthropomorphic manner [24,25] and was fabricated with rapid prototyping resin via a 3D printer.”
MethodSelf-citationStepp, C. E., & Matsuoka, Y. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2168981 · Cited by 28
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6]–[12], with many groups successfully integrating these technologies into prosthetic hands, e.g., the cybernetic hand [8], [9].”
Metadata
- Authors
- Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C.
- Venue
- Biological Cybernetics
- Published
- 2006-12
- Volume
- 95
- Issue
- 6
- Pages
- 629-44
- ISSN
- 0340-1200 (ISSN-L)
- 1432-0770
- OpenAlex
- W1990718137
- Cited by
- 341
- References
- 79
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.