Integrated polymerase chain reaction chips utilizing digital microfluidics
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Light-Driven Motion of Liquids on a Photoresponsive Surface
Ichimura, K., Oh, S.-K., & Nakagawa, M. (2000) · Science · doi:10.1126/science.288.5471.1624 · Cited by 1,463
Chemical Amplification: Continuous-Flow PCR on a Chip
Kopp, M. U., Mello, A. J. D., & Manz, A. (1998) · Science · doi:10.1126/science.280.5366.1046 · Cited by 1,212
Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
Reversible Electrowetting and Trapping of Charge: Model and Experiments
Verheijen, H. J. J., & Prins, M. W. J. (1999) · Langmuir · doi:10.1021/la990548n · Cited by 509
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Paik, P., Pamula, V. K., Pollack, M. G., & Fair, R. B. (2003) · Lab on a Chip · doi:10.1039/b210825a · Cited by 327
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Zhang, C., & Xing, D. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm389 · Cited by 417
Microfluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends
Zhang, C., Xing, D., & Li, Y. (2007) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.05.003 · Cited by 376
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Putting Electrowetting to Work
Wheeler, A. R. (2008) · Science · doi:10.1126/science.1165719 · Cited by 315
Heterogeneous immunoassays using magnetic beads on a digital microfluidic platform
Sista, R. S., Eckhardt, A. E., Srinivasan, V., Pollack, M. G., Palanki, S., & Pamula, V. K. (2008) · Lab on a Chip · doi:10.1039/b807855f · Cited by 294
Multiplexed Real-Time Polymerase Chain Reaction on a Digital Microfluidic Platform
Hua, Z., Rouse, J. L., Eckhardt, A. E., Srinivasan, V., Pamula, V. K., Schell, W. A., Benton, J. L., Mitchell, T. G., & Pollack, M. G. (2010) · Analytical Chemistry · doi:10.1021/ac902510u · Cited by 248
Applications of micromixing technology
Jeong, G. S., Chung, S., Kim, C.-B., & Lee, S.-H. (2010) · The Analyst · doi:10.1039/b921430e · Cited by 234
Pluronic Additives: A Solution to Sticky Problems in Digital Microfluidics
Luk, V. N., Mo, G. C., & Wheeler, A. R. (2008) · Langmuir · doi:10.1021/la7039509 · Cited by 227
Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications
Mark, D., Haeberle, S., Roth, G., Von Stetten, F., & Zengerle, R. (2010) · NATO Science for Peace and Security Series A: Chemistry and Biology · doi:10.1007/978-90-481-9029-4_17 · Cited by 214
Programmable large area digital microfluidic array with integrated droplet sensing for bioassays
Hadwen, B., Broder, G. R., Morganti, D., Jacobs, A., Brown, C., Hector, J. R., Kubota, Y., & Morgan, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40273d · Cited by 211
Integration and detection of biochemical assays in digital microfluidic LOC devices
Malic, L., Brassard, D., Veres, T., & Tabrizian, M. (2010) · Lab Chip · doi:10.1039/b917668c · Cited by 207
Abdelgawad, M., Freire, S. L. S., Yang, H., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b801516c · Cited by 188
Choi, K., Kim, J.-Y., Ahn, J.-H., Choi, J.-M., Im, M., & Choi, Y.-K. (2012) · Lab on a Chip · doi:10.1039/c2lc21203j · Cited by 77
Metadata
- Authors
- Chang, Y.-H., Lee, G.-B., Huang, F.-C., Chen, Y.-Y., & Lin, J.-L.
- Venue
- Biomedical Microdevices
- Published
- 2006-05-20
- Volume
- 8
- Issue
- 3
- Pages
- 215-225
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2048013569
- Cited by
- 324
- References
- 18
- FWCI
- 14.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.