Microfluidic platform for hepatitis B viral replication study
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Hepatocytes, the cells responsible for the metabolic and detoxification processes in the liver, are the predominant target of hepatitis B virus (HBV) infections, a major cause of liver cancer. The limited availability of normal human hepatocytes for cell-culture based studies is a significant challenge in HBV-associated liver cancer research. Therefore, there is a need for miniaturized cell-culture systems that can serve as a platform for studying the effect of HBV infections on hepatocyte physiology. Here, we present a microfluidic platform that can be used to study HBV replication in both rat and human hepatocytes. Polydimethylsiloxane (PDMS) microchannels fabricated using soft lithography techniques served as a culture vessel for both primary rat hepatocytes (PRH) and a human hepatoblastoma cell line, HepG2. The micro cell-culture chamber was then used as a model for HBV replication studies. Cells were grown in static culture conditions and either transfected with an HBV-genome cDNA or infected with the viral genome expressed from a recombinant adenovirus. Supernatants collected from the microchannels were assayed for secreted HBV using polymerase chain reaction (PCR). We achieved approximately 40 and 10% transfection efficiencies in HepG2 cells and PRH respectively, and 80-100% adenoviral infection efficiency in PRH comparable to standard tissue culture methods. Moreover, we successfully detected replicated HBV using our novel platform. This platform can be easily extended to studies involving DNA transfection or HBV infection of primary human hepatocytes since only a small number of cells are required for studies in microfluidic chambers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sodunke et al. co-cultured primary human hepatocytes and bovine aortic endothelial cells on opposite faces of a porous membrane to create a stable hepatic-sinusoid chip, enabling chronic HBV infection studies for extended periods [230].”
From Constructing biomimetic microenvironments for liver regeneration (2025) · doi:10.1186/s12951-025-03729-9 · cites this paper as [230]
Citations
Cites
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Seeger, C., & Mason, W. S. (2000) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.64.1.51-68.2000 · Cited by 1,451
Sells, M. A., Chen, M. L., & Acs, G. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.4.1005 · Cited by 1,117
Dalby, B. (2004) · Methods · doi:10.1016/j.ymeth.2003.11.023 · Cited by 619
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
Transcription Factors in Liver Development, Differentiation, and Regeneration
Costa, R. H., Kalinichenko, V. V., Holterman, A.-X. L., & Wang, X. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.034 · Cited by 409
Microenvironment design considerations for cellular scale studies
Walker, G. M., Zeringue, H. C., & Beebe, D. J. (2004) · Lab on a Chip · doi:10.1039/b311214d · Cited by 388
Calcium Signaling by HBx Protein in Hepatitis B Virus DNA Replication
Bouchard, M. J., Wang, L.-H., & Schneider, R. J. (2001) · Science · doi:10.1126/science.294.5550.2376 · Cited by 385
Self-citationThe woodchuck hepatitis virus X gene is important for establishment of virus infection in woodchucks
Chen, H. S., Kaneko, S., Girones, R., Anderson, R. W., Hornbuckle, W. E., Tennant, B. C., Cote, P. J., Gerin, J. L., Purcell, R. H., & Miller, R. H. (1993) · Journal of Virology · doi:10.1128/jvi.67.3.1218-1226.1993 · Cited by 370
Differentiation-on-a-chip: A microfluidic platform for long-term cell culture studies
Tourovskaia, A., Figueroa-Masot, X., & Folch, A. (2005) · Lab on a Chip · doi:10.1039/b405719h · Cited by 363
Tilles, A. W., Baskaran, H., Roy, P., Yarmush, M. L., & Toner, M. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1071 · Cited by 330
Patterned cell culture inside microfluidic devices
Rhee, S. W., Taylor, A. M., Tu, C. H., Cribbs, D. H., Cotman, C. W., & Jeon, N. L. (2005) · Lab on a Chip · doi:10.1039/b403091e · Cited by 283
Hung, P. J., Lee, P. J., Sabounchi, P., Aghdam, N., Lin, R., & Lee, L. P. (2005) · Lab on a Chip · doi:10.1039/b410743h · Cited by 259
Hepatitis B Virus Infection of Tupaia Hepatocytes In Vitro And In Vivo
Walter, E., Keist, R., Niederöst, B., Pult, I., & Blum, H. E. (1996) · Hepatology · doi:10.1002/hep.510240101 · Cited by 238
Melegari, M., Scaglioni, P. P., & Wands, J. R. (1998) · Journal of Virology · doi:10.1128/jvi.72.3.1737-1743.1998 · Cited by 220
Chang, C. M., Jeng, K. S., Hu, C. P., Lo, S. J., Su, T. S., Ting, L. P., Chou, C. K., Han, S. H., Pfaff, E., & Salfeld, J. (1987) · The EMBO Journal · doi:10.1002/j.1460-2075.1987.tb04807.x · Cited by 177
Integration of Technologies for Hepatic Tissue Engineering
Nahmias, Y., Berthiaume, F., & Yarmush, M. L. (2006) · Springer eBooks · doi:10.1007/10_029 · Cited by 165
Embryonic development in the mouse is enhanced via microchannel culture
Raty, S., Walters, E. M., Davis, J., Zeringue, H., Beebe, D. J., Rodriguez-Zas, S. L., & Wheeler, M. B. (2004) · Lab on a Chip · doi:10.1039/b316437c · Cited by 163
Sprinzl, M. F., Oberwinkler, H., Schaller, H., & Protzer, U. (2001) · Journal of Virology · doi:10.1128/jvi.75.11.5108-5118.2001 · Cited by 150
Study of hepatocyte differentiation using embryonic stem cells
Lavon, N., & Benvenisty, N. (2005) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20590 · Cited by 134
Zhou, T., Guo, H., Guo, J., Cuconati, A., Mehta, A. S., & Block, T. M. (2006) · Antiviral Research · doi:10.1016/j.antiviral.2006.05.006 · Cited by 116
Romøren, K., Thu, B. J., Bols, N. C., & Evensen, Ø. (2004) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2004.02.007 · Cited by 112
Handling individual mammalian embryos using microfluidics
Glasgow, I. K., Zeringue, H. C., Beebe, D. J., Choi, S., Lyman, J. T., Chan, N. G., & Wheeler, M. B. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.918596 · Cited by 109
Evaluation of effects of shear stress on hepatocytes by a microchip-based system
Tanaka, Y., Yamato, M., Okano, T., Kitamori, T., & Sato, K. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/s08 · Cited by 107
Use of Electroporation to Introduce Biologically Active Foreign Genes into Primary Rat Hepatocytes
Tur‐Kaspa, R., Teicher, L., Levine, B. J., Skoultchi, A. I., & Shafritz, D. A. (1986) · Molecular and Cellular Biology · doi:10.1128/mcb.6.2.716 · Cited by 100
Bouchard, M. J., Wang, L., & Schneider, R. J. (2006) · Journal of Virology · doi:10.1128/jvi.80.9.4406-4414.2006 · Cited by 99
Self-citationCell infection within a microfluidic device using virus gradients
Walker, G. M. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.10.014 · Cited by 90
Cationic lipid-mediated transfection of liver cels in primary culture
Jarnagin, W. R., Debs, R. J., Wang, S.-S., & Bissell, D. M. (1992) · Nucleic Acids Research · doi:10.1093/nar/20.16.4205 · Cited by 65
Association of hepatitis viruses with hepatocellular carcinoma in Thailand
Tangkijvanich, P., Hirsch, P., Theamboonlers, A., Nuchprayoon, I., & Poovorawan, Y. (1999) · Journal of Gastroenterology · doi:10.1007/s005350050248 · Cited by 61
Long-term microfluidic cultures of myotube microarrays for high-throughput focal stimulation
Tourovskaia, A., Figueroa, X. A., & Folch, A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.123 · Cited by 56
Electrotransfection of Mammalian Cells Using Microchannel-Type Electroporation Chip
Shin, Y. S., Cho, K., Kim, J. K., Lim, S. H., Park, C. H., Lee, K. B., Park, Y., Chung, C., Han, D.-C., & Chang, J. K. (2004) · Analytical Chemistry · doi:10.1021/ac0496291 · Cited by 56
Cell culture and life support system for microbioreactor and bioassay
Tanaka, Y., Sato, K., Yamato, M., Okano, T., & Kitamori, T. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.06.053 · Cited by 35
Cell Culture and Animal Models of Viral Hepatitis. Part I: Hepatitis B
Guha, C., Mohan, S., Roy‐Chowdhury, N., & Roy‐Chowdhury, J. (2004) · Lab Animal · doi:10.1038/laban0704-37 · Cited by 35
Wang, C.-Y. J., GIAMBRONE, J. J., & Smith, B. F. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.7.2584-2590.2002 · Cited by 27
Diot, C., Gripon, P., Rissel, M., & Guguen‐Guillouzo, C. (1992) · Journal of Medical Virology · doi:10.1002/jmv.1890360206 · Cited by 11
Dickinson, M. E., Murray, B. A., Waters, C. W., Haynes, S. M., & Longmuir, K. J. (2002) · Differentiation · doi:10.1046/j.1432-0436.2002.700407.x · Cited by 10
Exogenous DNA expression in eukaryotic cells following microinjection
Boyd, A. L. (2002) · Methods in Cell Science · doi:10.1023/a:1024401924835 · Cited by 5
Yao, Y. Q., Zhang, D. F., Luo, Y., Zhang, D. Z., Huang, A. L., Wang, B., Zhou, W. P., Ren, H., & Guo, S. H. (2002) · PubMed · Cited by 2
Crossing the Membrane: Nonviral and Viral Delivery Methods for Use In Vitro and In Vivo
Bogoyevitch, M. A. (2002) · DNA and Cell Biology · doi:10.1089/104454902762053819 · Cited by 1
Research works printed but not linked: 6
- Y. Nahmias, F. Berthiaume, M.L. Yarmush, Adv. Biochem. Eng. Biotechnol 103, 309 (2007)
- C. Seeger, F. Zoulin, W.S. Mason, Fields Virology: Hepadnaviruses D.M. Knipe, P.M. Howley (Lippincott Williams & Wilkins, Philadelphia (2007), p 2977
- P.O. Seglen, Methods Toxicol 1, 231 (1993)
- G.M. Walker, D.J. Beebe, M.S. Ozers 4, 161 (2002)
- Y.Q. Yao, D.F. Zhang, Y. Luo, D.Z. Zhang, A.L. Huang, B. Wang, W.P. Zhou, H. Ren, S.H. Guo, Zhonghua Gan Zang Bing Za Zhi 10, 275 (2002)
- J.H. Yeon, J.-K. Park, Biochip J 1, 17 (2007)
Cited by
Engineered In Vitro Disease Models
Benam, K. H., Dauth, S., Hassell, B., Herland, A., Jain, A., Jang, K.-J., Karalis, K., Kim, H. J., MacQueen, L., Mahmoodian, R., et al. (2015) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-012414-040418 · Cited by 554
“Other microfluidic systems have been used to study virus infection (188, 399); however, they have not yet been used to gain new mechanistic insight into viral pathogenesis or host-pathogen interactions.”
BackgroundMethodZhang, C., Zhao, Z., Abdul Rahim, N. A., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b915147h · Cited by 340
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
A microfluidic platform for complete mammalian cell culture
Barbulovic-Nad, I., Au, S. H., & Wheeler, A. R. (2010) · Lab on a Chip · doi:10.1039/c002147d · Cited by 249
Microfluidic organ-on-a-chip models of human liver tissue
Moradi, E., Jalili-Firoozinezhad, S., & Solati-Hashjin, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.08.041 · Cited by 204
Metadata
- Authors
- Sodunke, T. R., Bouchard, M. J., & Noh, H. (.
- Affiliations
- Drexel University (US)
- Corresponding author
- Noh, Hongseok (Moses)
- ORCID
- Bouchard, Michael J.
- Venue
- Biomedical Microdevices
- Published
- 2007-12-29
- Volume
- 10
- Issue
- 3
- Pages
- 393-402
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2018980642
- Cited by
- 38
- References
- 39
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 4 · 2022: 3 · 2021: 5 · 2020: 2 · 2019: 1 · 2018: 2 · 2017: 1 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 3
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institute on Alcohol Abuse and Alcoholism (R21 AA017458)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Epidemiology › Hepatitis B Virus Studies
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- hepatitis B virus, HBV replication, microfluidic cell culture, hepatocytes, primary rat hepatocytes, HepG2 cells, polydimethylsiloxane microchannel, soft lithography, adenovirus infection, DNA transfection, liver cancer
- MeSH terms
- Animals, Cell Separation, Cells, Cultured, Equipment Design, Flow Cytometry, Hepatitis B virus, Humans, Virus Cultivation, Cell Culture Techniques, Equipment Failure Analysis, Hepatocytes, Microfluidic Analytical Techniques, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.