Measurement of protein using bicinchoninic acid
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Bicinchoninic acid, sodium salt, is a stable, water-soluble compound capable of forming an intense purple complex with cuprous ion (Cu1+) in an alkaline environment. This reagent forms the basis of an analytical method capable of monitoring cuprous ion produced in the reaction of protein with alkaline Cu2+ (biuret reaction). The color produced from this reaction is stable and increases in a proportional fashion over a broad range of increasing protein concentrations. When compared to the method of Lowry et al., the results reported here demonstrate a greater tolerance of the bicinchoninate reagent toward such commonly encountered interferences as nonionic detergents and simple buffer salts. The stability of the reagent and resulting chromophore also allows for a simplified, one-step analysis and an enhanced flexibility in protocol selection. This new method maintains the high sensitivity and low protein-to-protein variation associated with the Lowry technique.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the BCA method, sensitive to cysteine, tyrosine, and tryptophan, typically reports higher values [27]”
From Functional and Bioactive Characterization of Hemp Cake Proteins and Polyphenols from Non-Psychoactive Cannabis sativa (2025) · cites this paper as [27]
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
DETERMINATION OF SERUM PROTEINS BY MEANS OF THE BIURET REACTION
Gornall, A. G., Bardawill, C. J., & David, M. M. (1949) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)57021-6 · Cited by 16,158
Weichselbaum, C. T. E. (1946) · American Journal of Clinical Pathology · doi:10.1093/ajcp/16.3_ts.40 · Cited by 1,591
Review of the folin phenol protein quantitation method of lowry, rosebrough, farr and randall
Peterson, G. L. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90222-7 · Cited by 1,147
Highly reactive impurities in Triton X-100 and Brij 35: Partial characterization and removal
Ashani, Y., & Catravas, G. N. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90009-3 · Cited by 138
Chang, H. W., & Bock, E. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90283-3 · Cited by 122
Utilization of Alkoxy Ketones in the Synthesis of Quinolines by the Pfitzinger Reaction. II1
Lesesne, S. D., & Henze, H. R. (1942) · Journal of the American Chemical Society · doi:10.1021/ja01260a041 · Cited by 35
Postcolumn detection of serum proteins with the biuret and Lowry reactions
Schlabach, T. D. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90009-5 · Cited by 14
(1970) · Clinical Chemistry · doi:10.1093/clinchem/16.6.519 · Cited by 6
Research works printed but not linked: 2
- Tikhonov, 1965, Zh. Anal. Khim, 20, 390
- Gindler, 1970, Clin. Chem, 16, 536
Cited by
Items 1,101–1,145 of 1,145
A Dictyostelium Mutant with Reduced Lysozyme Levels Compensates by Increased Phagocytic Activity
Müller, I., Šubert, N., Otto, H., Herbst, R., Rühling, H., Maniak, M., & Leippe, M. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m411445200 · Cited by 35
Cahova, J., Blahova, J., Marsalek, P., Doubkova, V., Franc, A., Garajová, M., Tichy, F., Mares, J., & Svobodova, Z. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.145570 · Cited by 34
Dimitrijevic, D., Fabian, E., Nicol, B., Funk-Weyer, D., & Landsiedel, R. (2022) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.2c00128 · Cited by 34
Ramírez, C. M., Torrecilla-Parra, M., Pardo-Marqués, V., de-Frutos, M. F., Pérez-García, A., Tabraue, C., de la Rosa, J. V., Martín-Rodriguez, P., Díaz-Sarmiento, M., Nuñez, U., et al. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.635923 · Cited by 34
“An aliquot of each extract was preserved for protein quantification by bicinchoninic acid assay (32).”
MethodRegulation of reconstituted high density lipoprotein structure and remodeling by apolipoprotein E
Rye, K.-A., Bright, R., Psaltis, M., & Barter, P. J. (2006) · Journal of Lipid Research · doi:10.1194/jlr.m500525-jlr200 · Cited by 33
“Protein concentrations were determined by the bicinchoninic acid assay (24).”
MethodMeasuring Mitochondrial Protein Thiol Redox State
Requejo, R., Chouchani, E. T., Hurd, T. R., Menger, K. E., Hampton, M. B., & Murphy, M. P. (2010) · Methods in Enzymology · doi:10.1016/s0076-6879(10)74008-8 · Cited by 31
Maltsev, Y., Gusev, E., Maltseva, I., Kulikovskiy, M., Namsaraev, Z., Petrushkina, M., Filimonova, A., Sorokin, B., Golubeva, A., Butaeva, G., et al. (2018) · Algal Research · doi:10.1016/j.algal.2018.06.008 · Cited by 29
Brinza, I., Ayoub, I. M., Eldahshan, O. A., & Hritcu, L. (2021) · Plants · doi:10.3390/plants10061245 · Cited by 29
Bacteriomimetic invasin-functionalized nanocarriers for intracellular delivery
Labouta, H. I., Menina, S., Kochut, A., Gordon, S., Geyer, R., Dersch, P., & Lehr, C.-M. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.10.052 · Cited by 29
“This assay is suitable to measure even proteins covalently bound to surfaces [13].”
Spectroscopic Studies of Cobalt(II) Binding to Escherichia coli Bacterioferritin
Keech, A. M., Brun, N. E. L., Wilson, M. T., Andrews, S. C., Moore, G. R., & Thomson, A. J. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.1.422 · Cited by 29
Hydrolytic Enzyme Protease in Sludge: Recovery and Its Application
Karn, S. K., & Kumar, A. (2015) · Biotechnology and Bioprocess Engineering · doi:10.1007/s12257-015-0161-6 · Cited by 27
“Triton and EDTA which are used for protein and enzyme extraction [5,49] show stronger interference towards Lowry measurements compared to bicinchoninic acid (BCA) method [50].”
ResultJourová, L., Anzenbacher, P., Lišková, B., Matušková, Z., Hermanová, P., Hudcovic, T., Kozáková, H., Hrnčířová, L., & Anzenbacherová, E. (2017) · Folia Microbiologica · doi:10.1007/s12223-017-0517-8 · Cited by 26
Wang, S., Gopinath, T., Larsen, E. K., Weber, D. K., Walker, C., Uddigiri, V. R., Mote, K. R., Sahoo, S. K., Periasamy, M., & Veglia, G. (2021) · Science Advances · doi:10.1126/sciadv.abi7154 · Cited by 26
“The yield of SERCA was evaluated by a bicinchoninic acid protein assay (63).”
MethodArchitecture of the RNF1 complex that drives biological nitrogen fixation
Zhang, L., & Einsle, O. (2024) · Nature Chemical Biology · doi:10.1038/s41589-024-01641-1 · Cited by 25
Architecture of the NADH:ferredoxin oxidoreductase RNF that drives Biological Nitrogen Fixation
Zhang, L., & Einsle, O. (2022) · doi:10.1101/2022.07.08.499327 · Cited by 25
Rodrigues, J. V., Victor, B. L., Huber, H., Saraiva, L. M., Soares, C. M., Cabelli, D. E., & Teixeira, M. (2008) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-007-0313-z · Cited by 24
Circadian regulation of macromolecular complex turnover and proteome renewal
(2024) · doi:10.1038/s44318-024-00121-5 · Cited by 24
“For determination of protein concentration, Pierce bicinchoninic acid assay (BCA, Thermo Scienti fi c, 23225) (Smith et al, 1985) was performed in microplate format according to manufacturer ’ s instructions, with bovine serum albumin (BSA) protein standards diluted in the same lysis buffer as…”
Øverbye, A., Sætre, F., Hagen, L. K., Johansen, H. T., & Seglen, P. O. (2011) · Autophagy · doi:10.4161/auto.7.9.16436 · Cited by 23
Guadalupe‐Grau, A., Rodríguez‐García, L., Torres‐Peralta, R., Morales‐Álamo, D., Ponce‐González, J. G., Pérez‐Suarez, I., Santana, A., & Calbet, J. A. (2016) · European Journal of Sport Science · doi:10.1080/17461391.2015.1063701 · Cited by 22
Castoldi, A., Empting, M., De Rossi, C., Mayr, K., Dersch, P., Hartmann, R., Müller, R., Gordon, S., & Lehr, C.-M. (2019) · Pharmaceutical Research · doi:10.1007/s11095-018-2521-3 · Cited by 22
Rubin, E. J., O'Brien, J. P., Ivanov, P. L., Brodbelt, J. S., & Trent, M. S. (2014) · Molecular Microbiology · doi:10.1111/mmi.12501 · Cited by 21
“Protein concentration was determined by the bicinchoninic acid assay method using bovine serum albumin as the standard (Smith et al., 1985).”
MethodLi, Q., Chang, R., Sun, Y., & Li, B. (2016) · PLOS ONE · doi:10.1371/journal.pone.0166876 · Cited by 19
Turk, H. (2021) · Plants · doi:10.3390/plants10071326 · Cited by 16
“[32] by using the bicinchoninic procedure.”
Sierri, G., Dal Magro, R., Vergani, B., Leone, B. E., Formicola, B., Taiarol, L., Fagioli, S., Kravicz, M., Tremolizzo, L., Calabresi, L., et al. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms23010102 · Cited by 16
“The amount of Aβ1-42 in the samples was measured by Bradford assay [36].”
MethodTremblay-Bourgeois, S., Le François, N. R., Roy, R. L., Benfey, T. J., & Imsland, A. K. (2009) · Aquaculture Research · doi:10.1111/j.1365-2109.2009.02405.x · Cited by 16
Lauer, A. A., Mett, J., Janitschke, D., Thiel, A., Stahlmann, C. P., Bachmann, C. M., Ritzmann, F., Schrul, B., Müller, U. C., Stein, R., et al. (2020) · Aging Cell · doi:10.1111/acel.13264 · Cited by 15
“Bicinchoninic acid assay was used for determination of the protein concentrations in samples according to Smith et al. (1985) as described in detail earlier.”
MethodCa2+-independent syntaxin binding to the C2B effector region of synaptotagmin
Masumoto, T., Suzuki, K., Ohmori, I., Michiue, H., Tomizawa, K., Fujimura, A., Nishiki, T.-I., & Matsui, H. (2012) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2011.09.007 · Cited by 14
“Protein concentrations were determined to be 2 mg/mL by the bicinchoninic acid method using bovine serum albumin as a reference protein (Smith et al., 1985).”
Cho, W.-H., Park, J.-C., Kim, D.-H., Kim, M.-S., Lee, S.-Y., Park, H., Kang, J.-H., Yeon, S.-W., & Han, J.-S. (2014) · Neuroscience Letters · doi:10.1016/j.neulet.2014.09.036 · Cited by 13
Sex‐Dependent Effects of CYP2D6 on the Pharmacokinetics of Berberine in Humans
Blöcher, J. A., Meyer‐Tönnies, M. J., Morof, F., Rönnpagel, V., Bethmann, J., Vollmer, M., Engeli, S., & Tzvetkov, M. V. (2025) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.3454 · Cited by 16
Igartua, M., Hernández, R. M., Gutierro, I., Gascón, A. R., & Pedraz, J. L. (2001) · Pharmaceutical Development and Technology · doi:10.1081/pdt-120000299 · Cited by 12
“Total extract loading was estimated using the microBCA assay (21) after disruption of the microspheres with 2.”
MethodGbu Glycine Betaine Porter and Carnitine Uptake in Osmotically Stressed Listeria monocytogenes Cells
Mendum, M. L., & Smith, L. T. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.11.5647-5655.2002 · Cited by 12
Ouellet, J.-F., Guillemette, M., & Blier, P. U. (2008) · Canadian Journal of Zoology · doi:10.1139/z08-021 · Cited by 12
Stettler, P., Schimanski, B., Aeschlimann, S., & Schneider, A. (2024) · PLOS Pathogens · doi:10.1371/journal.ppat.1012635 · Cited by 10
“The final eluate was concentrated using a 3 kDa size filter (Millipore) to approximately 1 μ g/ μ l as determined by the BCA test (Thermo Scientific) [44].”
Hayashi, R., Kamata, K., Gerdol, M., Fujii, Y., Hayashi, T., Onoda, Y., Kobayashi, N., Furushima, S., Ishiwata, R., Ohkawa, M., et al. (2024) · Marine Drugs · doi:10.3390/md22090400 · Cited by 7
“…a micro-BCA protein assay kit (Thermo Fisher/Pierce, Waltham, MA, USA) based on the principle of bicinchoninic acid for colorimetric detection [37,38], using bovine serum albumin as a standard by measuring A570 (reference: A600) with a microplate reader (model iMark; Bio-Rad Laboratories,…”
MethodBarahona, E., Collantes-García, J. A., Rosa-Núñez, E., Xiong, J., Jiang, X., Jiménez-Vicente, E., Echávarri-Erasun, C., Guo, Y., Rubio, L. M., & González-Guerrero, M. (2024) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2024.107900 · Cited by 7
Barre, A., Sénéchal, H., Nguyen, C., Granier, C., Poncet, P., & Rougé, P. (2023) · Allergies · doi:10.3390/allergies3010002 · Cited by 7
“The protein content of the protein extract was evaluated using the bicinchoninic acid kit reagent (Pierce) [27], with the banana TLP Mus a 4 [28] as a standard.”
MethodDevelopment of an Affinity-Based Probe to Profile Endogenous Human Adenosine A 3 Receptor Expression
Beerkens, B. L. H., Snijders, I. M., Snoeck, J., Liu, R., Tool, A. T. J., Le Dévédec, S. E., Jespers, W., Kuijpers, T. W., van Westen, G. J. P., Heitman, L. H., et al. (2023) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.3c00854 · Cited by 6
Quinteros, M., Wilcaso, P., Ribadeneira, C., & Vilcacundo, E. (2025) · Processes · doi:10.3390/pr13103184 · Cited by 3
Xiong, Y., Qu, Y., Min, Z., Wu, J., Zhang, S., & Xue, Z. (2022) · International Journal of Nanomedicine · doi:10.2147/ijn.s351830 · Cited by 4
“This method can quantitatively measure solution levels by comparing optical densities (ODs) between unknown and known proteins.(17)”
MethodBertsova, Y. V., Serebryakova, M. V., Baykov, A. A., & Bogachev, A. V. (2026) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2025.130886 · Cited by 2
Petsevа, Y., Mladenova, K., Ganeva, M., Radeva, V., Videv, P., Doumanov, J., & Petrova, S. (2025) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2025.110351 · Cited by 2
Campos Farias, B. J., Makoto Kayano, A., Barros Luiz, M., Maciel DE Lima, A., Suelen da Silva Morais, M., Moreira Mendes, L., Mota Santana, H., Reis Prado, N. D., Andrade Roberto, S., Martins Soares, A., et al. (2024) · Toxicon · doi:10.1016/j.toxicon.2024.107837 · Cited by 1
Fundamental Methods in Molecular Biology
Ijaz, S., & Hassan, S. (2026) · Molecular Biology Methods · doi:10.1007/978-981-92-2642-9_1
Karakaya, S., & Hassas, E. (2025) · International Journal of Food Science and Technology · doi:10.1093/ijfood/vvae062
(2024) · doi:10.1101/2024.10.03.616434
Metadata
- Authors
- Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C.
- Corresponding author
- Smith, P.K.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 1985-10
- Volume
- 150
- Issue
- 1
- Pages
- 76-85
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W4232534952
- Cited by
- 18,482
- References
- 9
- Citations by year
- 2026: 341 · 2025: 420 · 2024: 426 · 2023: 448 · 2022: 477 · 2021: 524 · 2020: 479 · 2019: 534 · 2018: 477 · 2017: 487 · 2016: 485 · 2015: 486 · 2014: 504 · 2013: 505 · 2012: 499
- FWCI
- 78.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Analytical Biochemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Interaction Studies and Fluorescence Analysis
- Keywords
- protein quantification, Lowry method, biuret reaction, cuprous ions, chromogenic assay, reagent stability, detergent interference
- MeSH terms
- Hydrogen-Ion Concentration, Indicators and Reagents, Proteins, Quinolines, Solubility, Spectrophotometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.