Biphasic indentation of articular cartilage—I. Theoretical analysis
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
A mathematical solution has been obtained for the indentation creep and stress-relaxation behavior of articular cartilage where the tissue is modeled as a layer of linear KLM biphasic material of thickness h bonded to an impervious, rigid bony substrate. The circular (radius = a), plane-ended indenter is assumed to be rigid, porous, free-draining, and frictionless. Double Laplace and Hankel transform techniques were used to solve the partial differential equations. The transformed equations and boundary conditions yielded an integral equation of the Fredholm type which was analyzed asymptotically and solved numerically. Our asymptotic analyses showed that the linear KLM biphasic material behaves like an incompressible (v = 0.5) single-phase elastic solid at t = 0+; the instantaneous response of the material is governed by the shear modulus (mu s) of the solid matrix. The linear KLM biphasic material behaves like a compressible elastic solid with material properties defined by those of the solid matrix, i.e. (lambda s, mu s) or (mu s, v s) as t----infinity. The transient viscoelastic creep and stress-relaxation behavior, 0 less than t less than infinity, of this material is controlled by the frictional drag (which is inversely proportional to the permeability k) associated with the flow of the interstitial fluid through the porous-permeable solid matrix. For given values of the Poisson's ratio of the solid matrix v s and the aspect ratio a/h, where a is the radius of the indenter and h is the thickness of the layer, the creep behavior with respect to the dimensionless time H Akt/a2 is completely controlled by the load parameter P/2 mu sa2 and the stress relaxation behavior is completely controlled by the rate of compression parameter R0 = kH A/V0h where H A = lambda s + 2 mu s and the equilibrium strain u0/h. This mathematical solution may now be used to describe an indentation experiment on articular cartilage to determine the intrinsic material properties of the tissue, i.e. permeability k, and the elastic coefficients of the solid phase (lambda s, mu s) or (mu s, v s).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ueber die Berührung fester elastischer Körper.
Hertz, H. (1882) · crll · doi:10.1515/crll.1882.92.156 · Cited by 4,789
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Self-citationFluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024
Self-citationCell biology of extracellular matrix
(1992) · Cell · doi:10.1016/0092-8674(92)90608-f · Cited by 1,010
A mathematical analysis for indentation tests of articular cartilage
Hayes, W. C., Keer, L. M., Herrmann, G., & Mockros, L. F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90010-3 · Cited by 967
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770
Self-citationBalance between swelling pressure and collagen tension in normal and degenerate cartilage
MAROUDAS, A. (1976) · Nature · doi:10.1038/260808a0 · Cited by 726
Uber die Beruhrung fester elastischer Korper
Hertz, H. G. (1882) · Medical Entomology and Zoology · Cited by 719
The frictional properties of animal joints
McCutchen, C. W. (1962) · Wear · doi:10.1016/0043-1648(62)90176-x · Cited by 640
Akizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040401 · Cited by 504
Self-citation
Cited by
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage
Athanasiou, K. A., Rosenwasser, M. P., Buckwalter, J. A., Malinin, T. I., & Mow, V. C. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090304 · Cited by 750
Self-citationDepth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646
Mechanical characterisation of hydrogel materials
Oyen, M. L. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000022 · Cited by 635
The role of interstitial fluid pressurization in articular cartilage lubrication
Ateshian, G. A. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.04.040 · Cited by 533
Biphasic indentation of articular cartilage—II. A numerical algorithm and an experimental study
Mow, V. C., Gibbs, M. C., Lai, W. M., Zhu, W. B., & Athanasiou, K. A. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90069-9 · Cited by 509
Self-citationNanoindentation of biological materials
Ebenstein, D. M., & Pruitt, L. A. (2006) · Nano Today · doi:10.1016/s1748-0132(06)70077-9 · Cited by 479
Stolz, M., Raiteri, R., Daniels, A. U., VanLandingham, M. R., Baschong, W., & Aebi, U. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74375-1 · Cited by 454
Recent Progress in Cartilage Lubrication
Lin, W., & Klein, J. (2021) · Advanced Materials · doi:10.1002/adma.202005513 · Cited by 446
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Setton, L. A., Elliott, D. M., & Mow, V. C. (1999) · Osteoarthritis and Cartilage · doi:10.1053/joca.1998.0170 · Cited by 378
Self-citationComposition and Dynamics of Articular Cartilage: Structure, Function, and Maintaining Healthy State
Cohen, N. P., Foster, R. J., & Mow, V. C. (1998) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1998.28.4.203 · Cited by 352
Self-citationAn asymptotic solution for the contact of two biphasic cartilage layers
Ateshian, G. A., Lai, W. M., Zhu, W. B., & Mow, V. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90044-2 · Cited by 350
Self-citationOptical and mechanical determination of poisson's ratio of adult bovine humeral articular cartilage
Jurvelin, J. S., Buschmann, M. D., & Hunziker, E. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00133-9 · Cited by 344
Athanasiou, K. A., Agarwal, A., & Dzida, F. J. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120306 · Cited by 343
Soltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330
Setton, L. A., Zhu, W., & Mow, V. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90019-b · Cited by 316
Self-citationMechanical Properties of Natural Cartilage and Tissue-Engineered Constructs
Little, C. J., Bawolin, N. K., & Chen, X. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0572 · Cited by 314
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
Kleemann, R. U., Krocker, D., Cedraro, A., Tuischer, J., & Duda, G. N. (2005) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2005.06.008 · Cited by 283
Costa, K. D., & Yin, F. C. P. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835074 · Cited by 265
Biomechanics of Articular Cartilage and Determination of Material Properties
LU, X. L., & MOW, V. C. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815cb1fc · Cited by 253
Self-citationA practical guide for analysis of nanoindentation data
Oyen, M. L., & Cook, R. F. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.10.002 · Cited by 251
Single‐Cell Elastography: Probing for Disease with the Atomic Force Microscope
Costa, K. D. (2004) · Disease Markers · doi:10.1155/2004/482680 · Cited by 233
Setton, L. A., Mow, V. C., Müller, F. J., Pita, J. C., & Howell, D. S. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120402 · Cited by 227
Self-citationAn ultrasound indentation system for biomechanical properties assessment of soft tissues in-vivo
Zheng, Y.-P., & Mak, A. F. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.532125 · Cited by 218
Self-citationBiomechanical topography of human ankle cartilage
Athanasiou, K. A., Niederauer, G. G., & Schenck, R. C. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584467 · Cited by 216
Biomechanical properties of knee articular cartilage
Laasanen, M. S., Töyräs, J., Korhonen, R. K., Rieppo, J., Saarakkala, S., Nieminen, M. T., Hirvonen, J., & Jurvelin, J. S. (2003) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2003040001003020 · Cited by 212
“As a next step the isotropic biphasic solution [25,29] could also explain the time dependence of the cartilage mechanical behaviour.”
Li, G., Lopez, O., & Rubash, H. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1385841 · Cited by 210
Ateshian, G. A., & Wang, H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00008-6 · Cited by 206
Herberhold, C., Faber, S., Stammberger, T., Steinlechner, M., Putz, R., Englmeier, K. H., Reiser, M., & Eckstein, F. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00130-x · Cited by 204
“These results are consistent with previous theoretical analyses (Mak et al., 1987; Ateshian et al., 1994), showing that there is little time for #uid to escape initially and therefore little change in the cartilage volume, due to the low permeability of the cartilage.”
ResultHuang, C.-Y., Soltz, M. A., Kopacz, M., Mow, V. C., & Ateshian, G. A. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1531656 · Cited by 198
Self-citationZheng, Y. P., Choi, Y. K. C., Wong, K., Chan, S., & Mak, A. F. T. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00163-5 · Cited by 171
Self-citationImmunochemical and Mechanical Characterization of Cartilage Subtypes in Rabbit
Naumann, A., Dennis, J. E., Awadallah, A., Carrino, D. A., Mansour, J. M., Kastenbauer, E., & Caplan, A. I. (2002) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540205000807 · Cited by 170
“By curve-fitting the experimental creep curves with the master solution via a nonlinear regression procedure, the intrinsic material properties (aggregate modulus, Poisson’s ratio, and permeability) of the different cartilage subtypes were calculated (Mak et al. 1987; Mow et al. 1989).”
MethodFroimson, M. I., Ratcliffe, A., Gardner, T. R., & Mow, V. C. (1997) · Osteoarthritis and Cartilage · doi:10.1016/s1063-4584(97)80042-8 · Cited by 163
Self-citationWayne, J. S., McDowell, C. L., Shields, K. J., & Tuan, R. S. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.953 · Cited by 162
Li, W.-J., Chiang, H., Kuo, T.-F., Lee, H.-S., Jiang, C.-C., & Tuan, R. S. (2009) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.127 · Cited by 160
“The tensile stress-relaxation property of each specimen was determined by an unconfined uniaxial indentation test using a custom-designed mechanical tester (Mak et al., 1987; Mow et al., 1989) as described previously (Chiang et al., 2005).”
MethodGasik, M., Zühlke, A., Haaparanta, A.-M., Muhonen, V., Laine, K., Bilotsky, Y., Kellomäki, M., & Kiviranta, I. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00187 · Cited by 24
Metadata
- Authors
- Mak, A. F., Lai, W. M., & Mow, V. C.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1987
- Volume
- 20
- Issue
- 7
- Pages
- 703-714
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2042167236
- Cited by
- 478
- References
- 39
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.