Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/ polyglycolic acid copolymers
The DOI matches its Crossref record; 103 of the 104 references it cites were found in a registry or an index.
Abstract
This is a review of salient studies of sterilization, toxicity, biocompatibility, clinical applications and current work in the field of orthopaedics, using implants made of polylactic acid (PLA), polyglycolic acid (PGA) and their copolymers. The intrinsic nature of these biomaterials renders them suitable for applications where temporally slow releases of bioactive agents in situ may be required. They are also desirable as fixation devices of bone, because they can virtually eliminate osteopenia associated with stress shielding or additional surgery. The majority of currently available sterilization techniques are not suitable for these thermoplastic materials and it may be desirable to develop new sterilization standards, which can account for the special character of PLA-PGA materials. Biocompatibility and toxicity studies suggest that, overall, PLA-PGA biomaterials may be suitable for orthopaedic applications, although certain problems, especially pertaining to reduction in cell proliferation, have been reported. Clinical applications are also promising, albeit not without problems usually associated with transient tissue inflammation. The future of these materials appears bright, especially in soft tissues. They may be used to address the exceedingly complex problem of osteochondral repair, but also as a means to enhance fixation and repair processes in tendons and ligaments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PLA has been used in combination with PGA as effective clinical scaffolds since the 1960s, with varying FBR responses depending on the type of host, material concentrations, and implantation site.[ 197 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [197]
In the citing paper
“The degradation of polylactic acid is contingent on many factors, including time, temperature, low-molecular-weight impurities, and catalyst concentration [27,55,56].”
From Synthesis and Biological Application of Polylactic Acid (2020) · cites this paper as [27]
Citations
Cites
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Neocartilage formation in vitro and in vivo using cells cultured on synthetic biodegradable polymers
Freed, L. E., Marquis, J. C., Nohria, A., Emmanual, J., Mikos, A. G., & Langer, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270104 · Cited by 952
Polylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Biodegradable poly(lactic acid) polymers
Kulkarni, R. K., Moore, E. G., Hegyeli, A. F., & Leonard, F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050305 · Cited by 799
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Laminated three-dimensional biodegradable foams for use in tissue engineering
Mikos, A. G., Sarakinos, G., Leite, S. M., Vacant, J. P., & Langer, R. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90049-8 · Cited by 666
Preparation of poly(glycolic acid) bonded fiber structures for cell attachment and transplantation
Mikos, A. G., Bao, Y., Cima, L. G., Ingber, D. E., Vacanti, J. P., & Langer, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270207 · Cited by 606
Frazza, E. J., & Schmitt, E. E. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050207 · Cited by 572
Bergsma, E. J., Rozema, F. R., Bos, R. R. M., & Bruijn, W. C. D. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80267-8 · Cited by 541
Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
Bostman, O., Hirvensalo, E., Makinen, J., & Rokkanen, P. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b4.2199452 · Cited by 526
Research works printed but not linked: 6
- van Sliedregt, 1990, The effect of the molecular weight of polylactic acid on in vitro biocompatibility, Adv Biomater, 9, 207
- Athanasiou, 1992, The use of biodegradable implants for repairing large articular cartilage defects in the rabbit, Trans Orthop Res Soc, 17, 172
- Athanasiou, 1993, Biodegradable carriers of TGF-β in rabbit osteochondral defects, Trans Orthop Res Soc, 18, 288
- Hirvensalo, 1988, Biodegradable fixation in intraarticulate fractures of the elbow joint, Acta Orthop Scand Suppl, 227, 78
- Hoffmann, 1989, Die distale Radiusfraktur. Frakturstabilisierung mit biodegradablen Osteosynthes Stiften (Biofix), Exper Unters Klinische Erfahrungen, 92, 430
- Agrawal, 1994, In vitro protein release characteristics of a bioabsorbable carrier of BMP for fracture non-unions, Trans ORS, 19, 602
Cited by
Items 101–200 of 1,004
Porous magnesium/PLGA composite scaffolds for enhanced bone regeneration following tooth extraction
Brown, A., Zaky, S., Ray, H., & Sfeir, C. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.09.008 · Cited by 217
Hile, D. D., Amirpour, M. L., Akgerman, A., & Pishko, M. V. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00268-0 · Cited by 210
Polyglycolic Acid-Induced Inflammation: Role of Hydrolysis and Resulting Complement Activation
Ceonzo, K., Gaynor, A., Shaffer, L., Kojima, K., Vacanti, C. A., & Stahl, G. L. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.301 · Cited by 209
“17,29 For example, approximately 10% of patients treated with rods made of PGA or polylactic acid (PLA) developed an inflammatory response requiring draining, with drainage consisting of a sterile fluid containing degraded PGA or PLA and inflammatory cells.”
Zhang, H., Mao, X., Du, Z., Jiang, W., Han, X., Zhao, D., Han, D., & Li, Q. (2016) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2016.1145532 · Cited by 208
Degradation Behaviors of Electrospun Resorbable Polyester Nanofibers
Dong, Y., Liao, S., Ngiam, M., Chan, C. K., & Ramakrishna, S. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0619 · Cited by 200
Shekhar, N., & Mondal, A. (2024) · Polymer Bulletin · doi:10.1007/s00289-024-05252-7 · Cited by 174
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Marijnissen, W. J. C. M., van Osch, G. J. V. M., Aigner, J., van der Veen, S. W., Hollander, A. P., Verwoerd-Verhoef, H. L., & Verhaar, J. A. N. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00281-2 · Cited by 206
“Degradation of E210 is, like all scaffolds made up by PGA/PLA, by hydrolysis [4,32,33], which is probably the reason why the biomaterial is degraded equally throughout the graft and led to a homogenous tissue.”
BackgroundVascular Tissue Engineering: Polymers and Methodologies for Small Caliber Vascular Grafts
Leal, B. B. J., Wakabayashi, N., Oyama, K., Kamiya, H., Braghirolli, D. I., & Pranke, P. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.592361 · Cited by 191
Strategic Design and Fabrication of Engineered Scaffolds for Articular Cartilage Repair
Izadifar, Z., Chen, X., & Kulyk, W. (2012) · Journal of Functional Biomaterials · doi:10.3390/jfb3040799 · Cited by 203
“volume of the engineered cartilage tissue construct [11–14].”
BackgroundPresent and future of tissue engineering scaffolds for dentin‐pulp complex regeneration
Moussa, D. G., & Aparicio, C. (2018) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2769 · Cited by 203
Polymeric drug delivery systems for localized cancer chemotherapy
De Souza, R., Zahedi, P., Allen, C. J., & Piquette-Miller, M. (2010) · Drug Delivery · doi:10.3109/10717541003762854 · Cited by 197
“While these polymers have been criticized for acidic degradation products that can cause local irritation and instability of the drugs being delivered (Taylor et al., 1994; Athanasiou et al., 1996; Fu et al., 2000), polyester-based polymers such as PLGA are considered biocompatible and biodegradable, and are therefore…”
BackgroundIn vitro evaluation of a chitosan membrane cross-linked with genipin
Mi, F.-L., Tan, Y.-C., Liang, H.-C., Huang, R.-N., & Sung, H.-W. (2001) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856201753113051 · Cited by 198
Strategies for overcoming protein and peptide instability in biodegradable drug delivery systems
Shi, M., & McHugh, K. J. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114904 · Cited by 184
Zhang, J. Y., Beckman, E. J., Piesco, N. P., & Agarwal, S. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00005-3 · Cited by 202
Biocomposites and hybrid biomaterials based on calcium orthophosphates
Dorozhkin, S. V. (2011) · Biomatter · doi:10.4161/biom.1.1.16782 · Cited by 198
New Pulsatile Bioreactor for In Vitro Formation of Tissue Engineered Heart Valves
Hoerstrup, S. P., Sodian, R., Sperling, J. S., Vacanti, J. P., & Mayer, J. E. (2000) · Tissue Engineering · doi:10.1089/107632700320919 · Cited by 200
Mendes, S. C., Reis, R. L., Bovell, Y. P., Cunha, A. M., van Blitterswijk, C. A., & de Bruijn, J. D. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00395-1 · Cited by 203
Small-diameter biodegradable scaffolds for functional vascular tissue engineering in the mouse model
Roh, J. D., Nelson, G. N., Brennan, M. P., Mirensky, T. L., Yi, T., Hazlett, T. F., Tellides, G., Sinusas, A. J., Pober, J. S., Saltzman, W. M., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.041 · Cited by 192
“However, prior reports using scaffolds constructed from similar polymers have demonstrated no evidence of an adaptive immune response to the biomaterials used in our scaffolds [26,27].”
ResultHaider, A., Haider, S., Rao Kummara, M., Kamal, T., Alghyamah, A.-A. A., Jan Iftikhar, F., Bano, B., Khan, N., Amjid Afridi, M., Soo Han, S., et al. (2020) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2020.01.002 · Cited by 188
“To achieve this goal as described above, synchronization (the friendlier relationship of cells with their mimic environment including material/scaffolds) of the materials/scaffolds and the cells is given pivotal importance [23,24,25,26,27].”
Tran, V.-T., Benoît, J.-P., & Venier-Julienne, M.-C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.01.027 · Cited by 188
Multilayered silk scaffolds for meniscus tissue engineering
Mandal, B. B., Park, S.-H., Gil, E. S., & Kaplan, D. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.115 · Cited by 193
Intrathecal delivery of a polymeric nanocomposite hydrogel after spinal cord injury
Baumann, M. D., Kang, C. E., Tator, C. H., & Shoichet, M. S. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.07.004 · Cited by 191
“Composite HAMC was of particular interest because PLGA can elicit a transient inflammatory response [50].”
BackgroundBarrioni, B. R., de Carvalho, S. M., Oréfice, R. L., de Oliveira, A. A. R., & Pereira, M. D. M. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.03.027 · Cited by 189
Hybrid fluorescent curcumin loaded zein electrospun nanofibrous scaffold for biomedical applications
Brahatheeswaran, D., Mathew, A., Aswathy, R. G., Nagaoka, Y., Venugopal, K., Yoshida, Y., Maekawa, T., & Sakthikumar, D. (2012) · Biomedical Materials · doi:10.1088/1748-6041/7/4/045001 · Cited by 185
Bone Tissue Engineering via Carbon‐Based Nanomaterials
Peng, Z., Zhao, T., Zhou, Y., Li, S., Li, J., & Leblanc, R. M. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901495 · Cited by 187
Li, J., Rothstein, S. N., Little, S. R., Edenborn, H. M., & Meyer, T. Y. (2012) · Journal of the American Chemical Society · doi:10.1021/ja306866w · Cited by 186
Cartilage-like Tissue Engineering Using Silk Scaffolds and Mesenchymal Stem Cells
Hofmann, S., Knecht, S., Langer, R., Kaplan, D. L., Vunjak-Novakovic, G., Merkle, H. P., & Meinel, L. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2729 · Cited by 182
Hirota, K., Hasegawa, T., Hinata, H., Ito, F., Inagawa, H., Kochi, C., Soma, G.-I., Makino, K., & Terada, H. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.01.013 · Cited by 178
Stayshich, R. M., & Meyer, T. Y. (2010) · Journal of the American Chemical Society · doi:10.1021/ja102670n · Cited by 178
Yu, L., Zhang, Z., Zhang, H., & Ding, J. (2010) · Biomacromolecules · doi:10.1021/bm100549q · Cited by 179
Biocompatibility of Resorbable Polymers: A Historical Perspective and Framework for the Future
Pappalardo, D., Mathisen, T., & Finne-Wistrand, A. (2019) · Biomacromolecules · doi:10.1021/acs.biomac.9b00159 · Cited by 177
In vitro degradation and cell attachment of a PLGA coated biodegradable Mg–6Zn based alloy
Li, J. N., Cao, P., Zhang, X. N., Zhang, S. X., & He, Y. H. (2010) · Journal of Materials Science · doi:10.1007/s10853-010-4688-9 · Cited by 177
Bini, T. B., Gao, S., Tan, T. C., Wang, S., Lim, A., Hai, L. B., & Ramakrishna, S. (2004) · Nanotechnology · doi:10.1088/0957-4484/15/11/014 · Cited by 175
Karp, J. M., Shoichet, M. S., & Davies, J. E. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10420 · Cited by 176
“PLGA undergoes bulk (autocatalytic) degradation by simple hydrolysis into lactic acid and glycolic acid.(23) After the initial in vitro culture period described for tissue-engineering applications, which was the focus of our experiments, the degradation process would be accelerated upon transplantation in vivo by enzy…”
MethodStem cell‐based composite tissue constructs for regenerative medicine
Rahaman, M. N., & Mao, J. J. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20292 · Cited by 173
“…of PGA and PLA can be crosslinked, woven, or braided to increase the mechanical strength of the resulting tissue-engineered tendons and ligaments (Athanasiou et al., 1996; Cavallaro et al., 1994; Chvapil et al., 1993; Davis et al., 1992; Dunn et al., 1992, 1997; Gentleman et al., 2003; Sato et…”
BackgroundPLA architectures: the role of branching
Corneillie, S., & Smet, M. (2015) · Polymer Chemistry · doi:10.1039/c4py01572j · Cited by 169
In Vivo Applications of Electrospun Tissue-Engineered Vascular Grafts: A Review
Rocco, K. A., Maxfield, M. W., Best, C. A., Dean, E. W., & Breuer, C. K. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0123 · Cited by 165
Xiong, X.-B., Uludağ, H., & Lavasanifar, A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.09.025 · Cited by 168
“Polyesters are proven biodegradable polymers and have a history of safe application in absorbable biomedical devices such as sutures [21,22].”
BackgroundŘíhová, B. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(96)00404-8 · Cited by 162
Kowalczewski, C. J., & Saul, J. M. (2018) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.00513 · Cited by 170
“Synthetic polymers have been reported to cause immunogenicity and toxicity due to chemical crosslinkers and polymerizers used in their production (Athanasiou et al., 1996; Williams et al., 2005).”
BackgroundMatrices and scaffolds for drug delivery in dental, oral and craniofacial tissue engineering
Moioli, E. K., Clark, P. A., Xin, X., Lal, S., & Mao, J. J. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.019 · Cited by 168
John, G., Nagarajan, S., Vemula, P. K., Silverman, J. R., & Pillai, C. K. S. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.02.008 · Cited by 162
Microporous nanofibrous fibrin-based scaffolds for bone tissue engineering
Osathanon, T., Linnes, M. L., Rajachar, R. M., Ratner, B. D., Somerman, M. J., & Giachelli, C. M. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.030 · Cited by 166
“However, the toxicity of the acidic degradation products of poly(lactide-co-glycolide) has limited their potential uses in bone tissue engineering [4].”
Flanagan, T. C., Sachweh, J. S., Frese, J., Schnöring, H., Gronloh, N., Koch, S., Tolba, R. H., Schmitz-Rode, T., & Jockenhoevel, S. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0018 · Cited by 160
“However, synthetic biodegradable polymers have a number of drawbacks, including the absence of natural cell attachment points, and the potential to release toxic degradation products if rapidly degrading formulations are employed, which can adversely affect the surrounding cells and host tissue.(4,5) Cell remnants wit…”
Olson, H. E., Rooney, G. E., Gross, L., Nesbitt, J. J., Galvin, K. E., Knight, A., Chen, B., Yaszemski, M. J., & Windebank, A. J. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0364 · Cited by 163
Engineering Three-Dimensional Pulmonary Tissue Constructs
Mondrinos, M. J., Koutzaki, S., Jiwanmall, E., Li, M., Dechadarevian, J.-P., Lelkes, P. I., & Finck, C. M. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.717 · Cited by 163
“36 The ability to engineer a scaffold that provides architecture and the possibility of controlled release of morphogenetic signals in a spatially and temporally controlled manner would be valuable for recapitulating lung development.”
Enzymatic degradation behavior and mechanism of Poly(lactide-co-glycolide) foams by trypsin
Cai, Q. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00377-0 · Cited by 161
Controlled Delivery of the Anti-VEGF Aptamer EYE001 with Poly(lactic-co-glycolic)Acid Microspheres
Carrasquillo, K. G., Ricker, J. A., Rigas, I. K., Miller, J. W., Gragoudas, E. S., & Adamis, A. P. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.01-1156 · Cited by 163
“Overall, it was determined that satisfactory biocompatibility was exhibited.(52,53)”
Wei, Z., Wang, C., Zou, S., Liu, H., & Tong, Z. (2012) · Polymer · doi:10.1016/j.polymer.2012.02.015 · Cited by 169
Processing, annealing and sterilisation of poly-l-lactide
Weir, N. A., Buchanan, F. J., Orr, J. F., Farrar, D. F., & Boyd, A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.076 · Cited by 160
Applications of Biocompatible Scaffold Materials in Stem Cell-Based Cartilage Tissue Engineering
Zhao, X., Hu, D. A., Wu, D., He, F., Wang, H., Huang, L., Shi, D., Liu, Q., Ni, N., Pakvasa, M., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.603444 · Cited by 174
Ex vivo synthesis of articular cartilage
LeBaron, R. G., & Athanasiou, K. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00125-3 · Cited by 161
“[19] Athanasiou KA, Niederauer GG, Agrawal CM.”
BackgroundSelf-citationPolymers in Drug Delivery—State of the Art and Future Trends
Grund, S., Bauer, M., & Fischer, D. (2011) · Advanced Engineering Materials · doi:10.1002/adem.201080088 · Cited by 169
Synthesis of poly(L-lactide) and polyglycolide by ring-opening polymerization
Kaihara, S., Matsumura, S., Mikos, A. G., & Fisher, J. P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.391 · Cited by 175
“thermal unzipping reaction and (3) ring-opening polymerization”
Kim, H., Yu, H., & Lee, H. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31677 · Cited by 155
In vitro degradation rate of apatitic calcium phosphate cement with incorporated PLGA microspheres
Lanao, R. P. F., Leeuwenburgh, S. C. G., Wolke, J. G. C., & Jansen, J. A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.036 · Cited by 173
Clinical Applications of Naturally Derived Biopolymer-Based Scaffolds for Regenerative Medicine
Stoppel, W. L., Ghezzi, C. E., McNamara, S. L., Black, L. D., & Kaplan, D. L. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1206-2 · Cited by 164
Yamaguchi, Y., Takenaga, M., Kitagawa, A., Ogawa, Y., Mizushima, Y., & Igarashi, R. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00060-3 · Cited by 153
Development of polyurethanes for bone repair
Marzec, M., Kucińska‐Lipka, J., Kalaszczyńska, I., & Janik, H. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.07.047 · Cited by 154
Shape-Memory Polymers for Biomedical Applications
Yakacki, C. M., & Gall, K. (2009) · Advances in polymer science · doi:10.1007/12_2009_23 · Cited by 168
Mesh biocompatibility: effects of cellular inflammation and tissue remodelling
Junge, K., Binnebösel, M., von Trotha, K., Rosch, R., Klinge, U., Neumann, U., & Jansen, P. L. (2012) · Langenbeck's archives of surgery (Print) · doi:10.1007/s00423-011-0780-0 · Cited by 145
Challenges in delivering therapeutic peptides and proteins: A silk-based solution
Wu, J., Sahoo, J. K., Li, Y., Xu, Q., & Kaplan, D. L. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.02.011 · Cited by 151
Flanagan, T. C., Cornelissen, C. G., Koch, S., Tschoeke, B., Sachweh, J. S., Schmitz‐Rode, T., & Jockenhoevel, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.012 · Cited by 149
Localized insulin-like growth factor I delivery to enhance new bone formation
Meinel, L., Zoidis, E., Zapf, J., Hassa, P. O., Hottiger, M. O., Auer, J. A., Schneider, R., Gander, B. A., Luginbuehl, V., Bettschart‐Wolfensberger, R., et al. (2003) · Bone · doi:10.1016/s8756-3282(03)00207-2 · Cited by 169
“It has been described that implantation of PLGA causes moderate local inflammation, which was related to the release of lactic and glycolic acid upon polymer biodegradation [40].”
BackgroundDowding, P. J., Atkin, R., Vincent, B., & Bouillot, P. (2004) · Langmuir · doi:10.1021/la048561h · Cited by 147
Papadimitriou, S. A., & Bikiaris, D. Ν. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.013 · Cited by 158
Effect of Scaffold Design on Bone Morphology In Vitro
Uebersax, L., Hagenmüller, H., Hofmann, S., Gruenblatt, E., Müller, R., Vunjaknovakovic, G., Kaplan, D. L., Merkle, H. P., & Meinel, L. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3417 · Cited by 143
“,6–9 Collagens remain problematic owing to concerns with bioburdens as well as rapid degradation.”
Synthesis and Properties of Star-Shaped Polylactide Attached to Poly(Amidoamine) Dendrimer
Cai, Q., Zhao, Y., Bei, J., Xi, F., & Wang, S. (2003) · Biomacromolecules · doi:10.1021/bm034051a · Cited by 144
Composite scaffolds for cartilage tissue engineering
Moutos, F. T., & Guilak, F. (2008) · Biorheology · doi:10.3233/bir-2008-0491 · Cited by 139
Fabrication of a novel porous PGA-chitosan hybrid matrix for tissue engineering
Wang, Y.-C., Lin, M.-C., Wang, D., & Hsieh, H. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00434-9 · Cited by 154
Fibrin-polylactide-based tissue-engineered vascular graft in the arterial circulation
Koch, S., Flanagan, T. C., Sachweh, J. S., Tanios, F., Schnoering, H., Deichmann, T., Ellä, V., Kellomäki, M., Gronloh, N., Gries, T., et al. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.051 · Cited by 158
“However, synthetic polymers alone lack native attachment sites for cell spreading, proliferation and differentiation, and the products released by rapid bulk degradation of some synthetic polymersmay cause adverse effects in the surrounding host tissue [8,9].”
BackgroundComparative chondrogenesis of human cell sources in 3D scaffolds
Seda Tıǧlı, R., Ghosh, S., Laha, M. M., Shevde, N. K., Daheron, L., Gimble, J., Gümüşderelioǧlu, M., & Kaplan, D. L. (2009) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.169 · Cited by 131
“…due to elevated acidity during polymer hydrolysis, there may be local tissue degeneration, processing difficulties may lead to inconsistent biodegradation rates and tissue response profiles or degradation profiles do not match the rate of tissue regeneration (Athanasiou et al., 1996; Suh, 1998).”
Biomaterial-guided delivery of gene vectors for targeted articular cartilage repair
Cucchiarini, M., & Madry, H. (2018) · Nature Reviews Rheumatology · doi:10.1038/s41584-018-0125-2 · Cited by 137
Todd, E. A., Mirsky, N. A., Silva, B. L. G., Shinde, A. R., Arakelians, A. R. L., Nayak, V. V., Marcantonio, R. A. C., Gupta, N., Witek, L., & Coelho, P. G. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15100280 · Cited by 150
Biodegradable Polymers in Bone Tissue Engineering
Kroeze, R. J., Helder, M. N., Govaert, L. E., & Smit, T. H. (2009) · Materials · doi:10.3390/ma2030833 · Cited by 152
“The T g of many polymers would be exceeded during hospital steam sterilization and their physical and mechanical properties thus altered, making this technique unsuitable for resorbable polymers [83].”
Bilayered Scaffolds for Osteochondral Tissue Engineering
O’Shea, T. M., & Miao, X. (2008) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2008.0327 · Cited by 152
Danoux, C. B., Barbieri, D., Yuan, H.-P., de Bruijn, J., van Blitterswijk, C. V., & Habibović, P. (2014) · Biomatter · doi:10.4161/biom.27664 · Cited by 126
“In vivo, although some cases of inflammatory response were reported upon PLA implantation, this polymer is considered to have an overall satisfactory biocompatibility.(44) In our in vivo study, the thin dense fibrous capsule observed around both PLA and PLA/HA implants after 12 wk of intramuscular implantation in dogs…”
BackgroundAlmoustafa, H. A., Alshawsh, M. A., & Chik, Z. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.09.054 · Cited by 140
“The more of the L enantiomer the more the degree of crystallinity, and since this enantiomer occurs naturally in the body, it is more biocompatible (Athanasiou et al., 1996).”
BackgroundChen, R., Curran, S. J., Curran, J. M., & Hunt, J. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.011 · Cited by 131
Bradburne, C. E., Delehanty, J. B., Gemmill, K. B., Mei, B. C., Mattoussi, H. M., Susumu, K., Blanco‐Canosa, J. B., Dawson, P. E., & Medintz, I. L. (2013) · Bioconjugate Chemistry · doi:10.1021/bc4001917 · Cited by 146
Recent Development in Therapeutic Cardiac Patches
Mei, X., & Cheng, K. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.610364 · Cited by 134
“Although it has been confirmed in animal models, the biocompatibility of current cardiac patches is still far below satisfaction and unable to meet the clinical requirement (148).”
BackgroundChen, F., Zhao, Y., Wu, H., Deng, Z., Wang, Q., Zhou, W. J., Liu, Q., Dong, G., Li, K., Wu, Z., et al. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.05.014 · Cited by 142
Articular Cartilage Tissue Engineering
Athanasiou, K. A., Darling, E. M., & Hu, J. C. Y. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02578-5 · Cited by 137
Self-citationPoly(lactic acid)-based particulate systems are promising tools for immune modulation
Peres, C., Matos, A. I., Conniot, J., Sainz, V., Zupančič, E., Silva, J. M., Graça, L., Gaspar, R. S., Préat, V., & Florindo, H. F. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.012 · Cited by 136
Synthesis and characterization of poly(lactic acid) based graft copolymers
Maharana, T., Pattanaik, S., Routaray, A., Nath, N., & Sutar, A. K. (2015) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2015.05.006 · Cited by 116
Shape dependent cytotoxicity of PLGA-PEG nanoparticles on human cells
Zhang, B., Sai Lung, P., Zhao, S., Chu, Z., Chrzanowski, W., & Li, Q. (2017) · Scientific Reports · doi:10.1038/s41598-017-07588-9 · Cited by 124
Bioresorbable polymers: heading for a new generation of spinal cages
Wuisman, P. I. J. M., & Smit, T. H. (2005) · European Spine Journal · doi:10.1007/s00586-005-1003-6 · Cited by 138
“However, factors not described in their study, such as the processing and fabricating technique, type of sterilization, and material-related parameters may have played a role in the premature degradation of their cage and the concomitant tissue reactions [4, 49, 108].”
BackgroundImproved cell adhesion by plasma-induced grafting of l-lactide onto polyurethane surface
Hsu, S., & Chen, W.-C. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00191-x · Cited by 128
Bittner, B., Mäder, K., Kroll, C., Borchert, H.-H., & Kissel, T. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(98)00170-9 · Cited by 136
Ryan, A. J., & O’Brien, F. J. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.09.003 · Cited by 136
Effects of 3D-Printed Polycaprolactone/β-Tricalcium Phosphate Membranes on Guided Bone Regeneration
Shim, J., Won, J.-Y., Park, J.-H., Bae, J.-H., Ahn, G., Kim, C., Lim, D.-H., Cho, D., Yun, W., Bae, E., et al. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18050899 · Cited by 125
Maksimenko, O., Malinovskaya, J. A., Шипуло, Е. В., Osipova, N., Razzhivina, V., Arantseva, D., Yarovaya, O. V., Леонидовна, М. У., Khalansky, A. S., Федосеева, В. В., et al. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118733 · Cited by 128
Polylactic acid (PLA) membrane—significance, synthesis, and applications: a review
More, N., Avhad, M. S., Utekar, S., & More, A. P. (2022) · Polymer Bulletin · doi:10.1007/s00289-022-04135-z · Cited by 130
Devices for periodontal regeneration
Tatakis, D. N., Promsudthi, A., & Wikesjö, U. M. E. (1999) · Periodontology 2000 · doi:10.1111/j.1600-0757.1999.tb00147.x · Cited by 145
Wang, Z., Yu, L., Ding, M., Tan, H., Li, J., & Fu, Q. (2011) · Polym. Chem. · doi:10.1039/c0py00235f · Cited by 119
Extended Release of Bevacizumab by Thermosensitive Biodegradable and Biocompatible Hydrogel
Wang, C., Hwang, Y., Chiang, P.-R., Shen, C., Hong, W.-H., & Hsiue, G. (2011) · Biomacromolecules · doi:10.1021/bm2009558 · Cited by 128
Gelmi, A., Cieslar‐Pobuda, A., de Muinck, E., Los, M., Rafat, M., & Jager, E. W. H. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600307 · Cited by 120
Chen, H., Yang, X., Chen, L., Wang, Y., & Sun, Y. (2016) · Scientific Reports · doi:10.1038/srep19207 · Cited by 123
Reduction of surface-induced inflammatory reaction on PLGA/MPC polymer blend.
Iwasaki, Y., Sawada, S., Ishihara, K., Khang, G., & Lee, H. B. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00135-7 · Cited by 116
Metadata
- Authors
- Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M.
- Affiliations
- The University of Texas at San Antonio Health Science Center (US)
- Corresponding author
- Athanasiou, Kyriacos A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 17
- Issue
- 2
- Pages
- 93-102
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2015639818
- Cited by
- 1,497
- References
- 104
- Citations by year
- 2026: 19 · 2025: 36 · 2024: 43 · 2023: 57 · 2022: 53 · 2021: 57 · 2020: 66 · 2019: 60 · 2018: 56 · 2017: 91 · 2016: 87 · 2015: 62 · 2014: 75 · 2013: 81 · 2012: 81
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- polylactic acid, polyglycolic acid, sterilization, biocompatibility, toxicity, orthopedic implants, bone fixation, stress shielding, osteopenia, cell proliferation, tissue inflammation, osteochondral repair
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Biocompatible Materials, Cell Division, Humans, Ligaments, Orthopedics, Polyglycolic Acid, Polymers, Sterilization, Sutures, Tendons, Lactic Acid, Prostheses and Implants, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.