Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/ polyglycolic acid copolymers
The DOI matches its Crossref record; 103 of the 104 references it cites were found in a registry or an index.
Abstract
This is a review of salient studies of sterilization, toxicity, biocompatibility, clinical applications and current work in the field of orthopaedics, using implants made of polylactic acid (PLA), polyglycolic acid (PGA) and their copolymers. The intrinsic nature of these biomaterials renders them suitable for applications where temporally slow releases of bioactive agents in situ may be required. They are also desirable as fixation devices of bone, because they can virtually eliminate osteopenia associated with stress shielding or additional surgery. The majority of currently available sterilization techniques are not suitable for these thermoplastic materials and it may be desirable to develop new sterilization standards, which can account for the special character of PLA-PGA materials. Biocompatibility and toxicity studies suggest that, overall, PLA-PGA biomaterials may be suitable for orthopaedic applications, although certain problems, especially pertaining to reduction in cell proliferation, have been reported. Clinical applications are also promising, albeit not without problems usually associated with transient tissue inflammation. The future of these materials appears bright, especially in soft tissues. They may be used to address the exceedingly complex problem of osteochondral repair, but also as a means to enhance fixation and repair processes in tendons and ligaments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PLA has been used in combination with PGA as effective clinical scaffolds since the 1960s, with varying FBR responses depending on the type of host, material concentrations, and implantation site.[ 197 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [197]
In the citing paper
“The degradation of polylactic acid is contingent on many factors, including time, temperature, low-molecular-weight impurities, and catalyst concentration [27,55,56].”
From Synthesis and Biological Application of Polylactic Acid (2020) · cites this paper as [27]
Citations
Cites
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Neocartilage formation in vitro and in vivo using cells cultured on synthetic biodegradable polymers
Freed, L. E., Marquis, J. C., Nohria, A., Emmanual, J., Mikos, A. G., & Langer, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270104 · Cited by 952
Polylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Biodegradable poly(lactic acid) polymers
Kulkarni, R. K., Moore, E. G., Hegyeli, A. F., & Leonard, F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050305 · Cited by 799
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Laminated three-dimensional biodegradable foams for use in tissue engineering
Mikos, A. G., Sarakinos, G., Leite, S. M., Vacant, J. P., & Langer, R. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90049-8 · Cited by 666
Preparation of poly(glycolic acid) bonded fiber structures for cell attachment and transplantation
Mikos, A. G., Bao, Y., Cima, L. G., Ingber, D. E., Vacanti, J. P., & Langer, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270207 · Cited by 606
Frazza, E. J., & Schmitt, E. E. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050207 · Cited by 572
Bergsma, E. J., Rozema, F. R., Bos, R. R. M., & Bruijn, W. C. D. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80267-8 · Cited by 541
Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
Bostman, O., Hirvensalo, E., Makinen, J., & Rokkanen, P. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b4.2199452 · Cited by 526
Daniels, A. U., Chang, M. K. O., Andriano, K. P., & Heller, J. (1990) · Journal of Applied Biomaterials · doi:10.1002/jab.770010109 · Cited by 483
Six bioabsorbable polymers: In vitro acute toxicity of accumulated degradation products
Taylor, M. S., Daniels, A. U., Andriano, K. P., & Heller, J. (1994) · Journal of Applied Biomaterials · doi:10.1002/jab.770050208 · Cited by 473
Absorbable implants for the fixation of fractures.
Böstman, O. M. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173010-00022 · Cited by 459
Resorbable materials of poly(l-lactide)
Leenslag, J. W., Pennings, A. J., Bos, R. R. M., Rozema, F. R., & Boering, G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90121-9 · Cited by 329
Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures
Bos, R. R. M., Boering, G., Rozema, F. R., & Leenslag, J. W. (1987) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(87)90194-7 · Cited by 324
Resorbable materials of poly(l-lactide). VI. Plates and screws for internal fracture fixation
Leenslag, J. W., Pennings, A. J., Bos, R. R. M., Rozema, F. R., & Boering, G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90034-2 · Cited by 295
Osteolytic changes accompanying degradation of absorbable fracture fixation implants
Bostman, O. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.1649195 · Cited by 294
BIODEGRADABLE IMPLANTS IN FRACTURE FIXATION: EARLY RESULTS OF TREATMENT OF FRACTURES OF THE ANKLE
Rokkanen, P., Vainionpää, S., Törmälä, P., Kilpikari, J., Böstman, O., Vihtonen, K., Laiho, J., & Tamminmäki, M. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91847-1 · Cited by 293
Brady, J. M., Cutright, D. E., Miller, R. A., Battistone, G. C., & Hunsuck, E. E. (1973) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820070204 · Cited by 281
Fixation with bioabsorbable screws for the treatment of fractures of the ankle.
Bucholz, R. W., Henry, S., & Henley, M. B. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199403000-00001 · Cited by 271
Hollinger, J. O. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170107 · Cited by 247
Polymer-hydroxyapatite composites for biodegradable bone fillers
Higashi, S., Yamamuro, T., Nakamura, T., Ikada, Y., Hyon, S.-H., & Jamshidi, K. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90099-2 · Cited by 228
Cooper, M. L., Hansbrough, J. F., Spielvogel, R. L., Cohen, R., Bartel, R. L., & Naughton, G. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90207-q · Cited by 221
Biological response of intramedullary bone to poly‐L‐lactic acid
Suganuma, J., & Alexander, H. (1993) · Journal of Applied Biomaterials · doi:10.1002/jab.770040103 · Cited by 213
Biomaterials and Biomechanics 1983
Peppas, N. A. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90013-4 · Cited by 211
Törmälä, P., Vasenius, J., Vainionpää, S., Laiho, J., Pohjonen, T., & Rokkanen, P. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250102 · Cited by 210
In vitro and in vivo studies on bioabsorbable ultra‐high‐strength poly(L‐lactide) rods
Matsusue, Y., Yamamuro, T., Oka, M., Shikinami, Y., Hyon, S., & Ikada, Y. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261203 · Cited by 200
Evaluation of hydroxylapatite/poly(l‐lactide) composites: Mechanical behavior
Verheyen, C. C. P. M., De Wijn, J. R., Van Blitterswijk, C. A., & De Groot, K. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261003 · Cited by 197
Fracture reduction using a biodegradable material, polylactic acid.
Cutright, D. E., Hunsuck, E. E., & Beasley, J. D. (1971) · PubMed · Cited by 195
BÖSTMAN, O. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199205000-00031 · Cited by 185
Kenley, R., Marden, L., Turek, T., Jin, L., Ron, E., & Hollinger, J. O. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281004 · Cited by 183
Ankle Fractures Treated Using Biodegradable Internal Fixation
BÖSTMAN, O., HIRENSALO, E., VAINIONPÄÄ, S., MÄKELÄ, A., VIHTONEN, K., TÖRMÄLÄ, P., & ROKKANEN, P. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198901000-00028 · Cited by 182
The use of bone morphogenetic protein in the treatment of non-union in a canine model.
Heckman, J. D., Boyan, B. D., Aufdemorte, T. B., & Abbott, J. T. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173050-00015 · Cited by 181
Biomaterials in reconstructive surgery
(1985) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(85)90211-3 · Cited by 170
Healing of large segmental defects in rat femurs is aided by RhBMP‐2 in PLGA matrix
Lee, S. C., Shea, M., Battle, M. A., Kozitza, K., Ron, E., Turek, T., Schaub, R. G., & Hayes, W. C. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281005 · Cited by 167
Biodegradable internal fixation for malleolar fractures. A prospective randomised trial
Bostman, O., Vainionpaa, S., Hirvensalo, E., Makela, A., Vihtonen, K., Tormala, P., & Rokkanen, P. (1987) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.69b4.3611169 · Cited by 161
Immune response to polyglycolic acid implants
Santavirta, S., Konttinen, Y., Saito, T., Gronblad, M., Partio, E., Kemppinen, P., & Rokkanen, P. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b4.2166048 · Cited by 160
Tissue reaction to the biodegradable polylactic acid suture
Cutright, D. E., & Hunsuck, E. E. (1971) · Oral Surgery Oral Medicine Oral Pathology · doi:10.1016/0030-4220(71)90044-2 · Cited by 144
Vainionpää, S., Kilpikari, J., Laiho, J., Helevirta, P., Rokkanen, P., & Törmälä, P. O. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90028-7 · Cited by 135
Li, F., Wu, Z., Chen, S., Huang, Z., Liang, C., & Lee, S. J. (2025) · International Review of Cell and Molecular Biology · doi:10.1016/bs.ircmb.2025.11.005 · Cited by 131
Enzymatic activity toward poly(L‐lactic acid) implants
Schakenraad, J. M., Hardonk, M. J., Feijen, J., Molenaar, I., & Nieuwenhuis, P. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240502 · Cited by 130
Biomaterials in Reconstructive Surgery
Rubin, L. R. (1987) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198707000-00035 · Cited by 125
Majola, A., Vainionpää, S., Vihtonen, K., MERO, M., Vasenius, J., Törmälä, P. O., & Rokkanen, P. (1991) · PubMed · Cited by 123
Biodegradable hollow fibres for the controlled release of drugs
Schakenraad, J. M., Oosterbaan, J. A., Nieuwenhuis, P., Molenaar, I., Olijslager, J., Potman, W., Eenink, M. J. D., & Feijén, J. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90082-8 · Cited by 119
von Schroeder, H. P., Kwan, M., Amiel, D., & Coutts, R. D. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250305 · Cited by 118
Böstman, O., Päivärinta, U., Partio, E., Vasenius, J., Manninen, M., & Rokkanen, P. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274070-00008 · Cited by 118
Foreign-body reactions to polyglycolide screws: Observations in 24/216 malleolar fracture cases
Böstman, O., Partio, E., Hirvensalo, E., & Rokkanen, P. (1992) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679209154817 · Cited by 116
Porous polymer implant for repair of meniscal lesions: a preliminary study in dogs
Klompmaker, J., Jansen, H. W. B., Veth, R. P. H., de Groot, J. H., Nijenhuis, A. J., & Pennings, A. J. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90066-j · Cited by 115
Histologic comparison of polylactic and polyglycolic acid sutures
Cutright, D. E., Beasley, J. D., & Perez, B. (1971) · Oral Surgery, Oral Medicine, Oral Pathology · doi:10.1016/0030-4220(71)90265-9 · Cited by 115
Fracture fixation with biodegradable rods Forty-one cases of severe ankle fractures
Hirvensalo, E. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909150131 · Cited by 112
Törmälä, P. O., Vainionpää, S., Kilpikari, J., & Rokkanen, P. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90027-5 · Cited by 111
The effect of phagocytosis of poly(L‐lactic acid) fragments on cellular morphology and viability
Lam, K. H., Schakenraad, J. M., Esselbrugge, H., Feijen, J., & Nieuwenhuis, P. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271214 · Cited by 109
Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial
Casteleyn, P., Handelberg, F., & Haentjens, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b6.1332974 · Cited by 108
In vivo and in vitro degradation of glycine/DL‐lactic acid copolymers
Schakenraad, J. M., Nieuwenhuis, P., Molenaar, I., Helder, J., Dijkstra, P. J., & Feijen, J. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231105 · Cited by 101
Polyglycolic Acid Surgical Suture: R. W. Postlethwait, MD, Durham, NC
Postlethwait, R. W. (1970) · Archives of Surgery · doi:10.1001/archsurg.1970.01340280041011 · Cited by 99
The effect of gamma irradiation on the enzymatic degradation of polyglycolic acid absorbable sutures
Chu, C. C., & Williams, D. F. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170612 · Cited by 95
Biodegradation of and tissue reaction to poly( DL ‐lactide) microcapsules
Visscher, G. E., Robison, R. L., Maulding, H. V., Fong, J. W., Pearson, J. E., & Argentieri, G. J. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200510 · Cited by 93
P�iv�rinta, U., B�stman, O., Majola, A., Toivonen, T., T�rm�l�, P. O., & Rokkanen, P. (1993) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00420258 · Cited by 88
Biodegradable pin fixation of elbow fractures in children. A randomised trial
Hope, P., Williamson, D., Coates, C., & Cole, W. (1991) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.73b6.1659570 · Cited by 88
Toxicity test of biodegradable polymers by implantation in rabbit cornea
Kobayashi, H., Shiraki, K., & Ikada, Y. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261106 · Cited by 87
Evaluation and comparisons of biodegradable substances as osteogenic agents
Nelson, J. F., Stanford, H. G., & Cutright, D. E. (1977) · Oral Surgery, Oral Medicine, Oral Pathology · doi:10.1016/0030-4220(77)90075-5 · Cited by 80
Degradation Phenomena on Polymeric Biomaterials
Planck, H., Dauner, M., & Renardy, M. (1992) · Springer eBooks · doi:10.1007/978-3-642-77563-5 · Cited by 79
Laitinen, O., Törmälä, P., Taurio, R., Skutnabb, K., Saarelainen, K., Iivonen, T., & Vainionpää, S. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90152-e · Cited by 77
Osteolysis after biodegradable pin fixation of fractures in children
Fraser, R., & Cole, W. (1992) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.74b6.1332975 · Cited by 75
Schmitz, J. P., & Hollinger, J. O. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198812000-00036 · Cited by 71
In vitro biocompatibility testing of polylactides Part I Proliferation of different cell types
van Sliedregt, A., Radder, A. M., de Groot, K., & van Blitterswijk, C. (1992) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00705369 · Cited by 69
Aeration of ethylene oxide-sterilized polymers
Vink, P., & Pleijsier, K. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90108-0 · Cited by 66
Transphyseal fracture fixation using biodegradable pins
Böstman, O. M., Ea, M., Törmälä, P. O., & Rokkanen, P. (1989) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.71b4.2549074 · Cited by 66
Robert, P. M., Mauduit, J., Frank, R. M., & Vert, M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90054-6 · Cited by 64
Galgut, P. N., Pitrola, R., Waite, I. M., Doyle, C., & Smith, R. (1991) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.1991.tb00093.x · Cited by 61
Absorbable polyglycolide pins in internal fixation of fractures in children.
Böstman, O. M., Mäkelä, E. A., Södergård, J., Hirvensalo, E., Törmälä, P., & Rokkanen, P. (1993) · PubMed · Cited by 59
The effects of different steam‐sterilization programs on material properties of poly(L‐lactide)
Rozema, F. R., Bos, R. R. M., Boering, G., van Asten, J. A. A. M., Nijenhuis, A. J., & Pennings, A. J. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020104 · Cited by 57
Degradable polyglycolide rods for the internal fixation of displaced bimalleolar fractures
B�stman, O., Hirvensalo, E., Vainionp��, S., Vihtonen, K., T�rm�l�, P. O., & Rokkanen, P. (1990) · International Orthopaedics · doi:10.1007/bf00183354 · Cited by 54
A Multiphase System Bone Implant for Regenerating the Calvaria
Kleinschmidt, J. C., Marden, L. J., Kent, D., Quigley, N. C., & Hollinger, J. O. (1993) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199304000-00002 · Cited by 53
(2017) · Focus on Catalysts · doi:10.1016/j.focat.2017.10.004 · Cited by 51
Böstman, O. M., Päivärinta, U., Partio, E. K., Manninen, M. J., Vasenius, J., Majola, A., & Rokkanen, P. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199212000-00036 · Cited by 50
Verheyen, C. C. P. M., De Wijn, J. R., van Blitterswijk, C. A., Rozing, P. M., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270817 · Cited by 50
Restoration of bone discontinuities in dogs using a biodegradable implant
Hollinger, J. O., & Schmitz, J. P. (1987) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(87)90269-2 · Cited by 49
Effectiveness of absorbable fixation devices in Austin bunionectomies
Gerbert, J. (1992) · Journal of the American Podiatric Medical Association · doi:10.7547/87507315-82-4-189 · Cited by 45
Effect of a Bioresorbable Film on Regeneration of Cranial Bone
Levy, F. E., Hollinger, J. O., & Szachowicz, E. H. (1994) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199402000-00011 · Cited by 44
Racey, G. L., Wallace, W. R., Cj, C., & Marguard, J. V. (1978) · PubMed · Cited by 42
Primary vascular anastomosis in growing pigs
Pae, W. E., Waldhausen, J. A., Prophet, G. A., & Pierce, W. S. (1981) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)39428-0 · Cited by 42
Hollinger, J. O. (1983) · Journal of Bone and Mineral Research · Cited by 41
Vicryl synthetic absorbable sutures.
Horton, C. E., Adamson, J. E., Mladick, R. A., & Carraway, J. H. (1974) · PubMed · Cited by 40
Degradation Phenomena on Polymeric Biomaterials
Planck, H., Dauner, M., & Renardy, M. (1992) · Medical Entomology and Zoology · Cited by 38
Athanasiou, K. A., Singhal, A. R., Agrawal, C. M., & Boyan, B. D. (1995) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199506000-00033 · Cited by 36
Self-citationBiodegradable rods versus Kirschner wire fixation of wrist fractures
Casteleyn, P., Handelberg, F., & Haentjens, P. (1993) · VUBIR (Vrije Universiteit Brussel) · Cited by 36
Tissue Response to Resorbable Synthetic Polymers
Gibbons, D. F. (1992) · Degradation Phenomena on Polymeric Biomaterials · doi:10.1007/978-3-642-77563-5_8 · Cited by 31
External fixation of fractures in children
Schranz, P. J., Gultekin, C., & Colton, C. L. (1992) · Injury · doi:10.1016/0020-1383(92)90036-r · Cited by 30
Induction of leukocyte activation by meshes surgically implanted in the peritoneal cavity
Devereux, D. F., O’Connell, S. M., Liesch, J. B., Weinstein, M. P., & Robertson, F. M. (1991) · The American Journal of Surgery · doi:10.1016/0002-9610(91)90078-r · Cited by 27
BIODEGRADABLE PIN FIXATION OF ELBOW FRACTURES IN CHILDREN
Hope, P., Williamson, D., & Coates, C. J. (1992) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199205000-00068 · Cited by 27
Enhanced Healing of Large Cranial Defects by an Osteoinductive Protein in Rabbits
Turk, A. E., Ishida, K., Jensen, J. A., Wollman, J. S., & Miller, T. A. (1993) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199309001-00006 · Cited by 27
Vicryl, synthetic absorbable sutures
Fischer, J. C. (1975) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-197509000-00071 · Cited by 26
Controlled trial of polyglycolic acid versus catgut and nylon for appendicectomy wound closure
Wetter, L. A., Dinneen, M. D., Levitt, M. D., & Motson, R. W. (1991) · British journal of surgery · doi:10.1002/bjs.1800780830 · Cited by 26
Enhanced healing of large cranial defects by an osteoinductive protein in rabbits.
Turk, A. E., Ishida, K., Jensen, J. A., et al. (1993) · PubMed · Cited by 26
The Role of Polyglycolic Acid Rods in the Regeneration of Cartilage from Perichondrium in Rabbits
Ruuskanen, M. M., Kallioinen, M. J., Kaarela, O. I., Laiho, J., Törmälä, P. O., & Waris, T. J. (1991) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844319109034917 · Cited by 23
Matthews, I. P., Gibson, C., & Samuel, A. H. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230202 · Cited by 21
Further Studies with Polyglycolic Acid (Dexon) and Other Sutures in Infected Experimental Wounds
Varma, S., Lumb, W. V., Johnson, L. W., & Ferguson, H. L. (1981) · American Journal of Veterinary Research · doi:10.2460/ajvr.1981.42.04.571 · Cited by 21
Tissue Response to Pre-Degraded Poly(L-Lactide)
Rozema, F. R., Bos, R. R. M., Boering, G., Nijenhuis, A. J., Pennings, A. J., Jansen, H. W. B., & de Bruijn, W. C. (1992) · Springer eBooks · doi:10.1007/978-3-642-77563-5_10 · Cited by 17
Development of polylactic/glycolic acid delivery systems for use in treatment of narcotic addiction.
Schwope, A. D., Wise, D. L., & Howes, J. F. (1975) · PubMed · Cited by 16
Infrared spectroscopic study of polymers exposed to ethylene oxide
Saalman, E. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90017-1 · Cited by 8
Devereux, D. F., O’Connell, S. M., Spain, D. A., & Robertson, F. M. (1991) · Diseases of the Colon & Rectum · doi:10.1007/bf02050348 · Cited by 5
[Treatment of fractures of the ankle].
Kaem (1953) · PubMed · Cited by 2
Research works printed but not linked: 6
- van Sliedregt, 1990, The effect of the molecular weight of polylactic acid on in vitro biocompatibility, Adv Biomater, 9, 207
- Athanasiou, 1992, The use of biodegradable implants for repairing large articular cartilage defects in the rabbit, Trans Orthop Res Soc, 17, 172
- Athanasiou, 1993, Biodegradable carriers of TGF-β in rabbit osteochondral defects, Trans Orthop Res Soc, 18, 288
- Hirvensalo, 1988, Biodegradable fixation in intraarticulate fractures of the elbow joint, Acta Orthop Scand Suppl, 227, 78
- Hoffmann, 1989, Die distale Radiusfraktur. Frakturstabilisierung mit biodegradablen Osteosynthes Stiften (Biofix), Exper Unters Klinische Erfahrungen, 92, 430
- Agrawal, 1994, In vitro protein release characteristics of a bioabsorbable carrier of BMP for fracture non-unions, Trans ORS, 19, 602
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Electrospun nanofibrous structure: A novel scaffold for tissue engineering
Li, W., Laurencin, C. T., Caterson, E. J., Tuan, R. S., & Ko, F. K. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10167 · Cited by 2,427
Controlled Ring-Opening Polymerization of Lactide and Glycolide
Dechy-Cabaret, O., Martin-Vaca, B., & Bourissou, D. (2004) · Chemical Reviews · doi:10.1021/cr040002s · Cited by 2,257
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204
Metadata
- Authors
- Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M.
- Affiliations
- The University of Texas at San Antonio Health Science Center (US)
- Corresponding author
- Athanasiou, Kyriacos A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 17
- Issue
- 2
- Pages
- 93-102
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2015639818
- Cited by
- 1,497
- References
- 104
- Citations by year
- 2026: 19 · 2025: 36 · 2024: 43 · 2023: 57 · 2022: 53 · 2021: 57 · 2020: 66 · 2019: 60 · 2018: 56 · 2017: 91 · 2016: 87 · 2015: 62 · 2014: 75 · 2013: 81 · 2012: 81
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- polylactic acid, polyglycolic acid, sterilization, biocompatibility, toxicity, orthopedic implants, bone fixation, stress shielding, osteopenia, cell proliferation, tissue inflammation, osteochondral repair
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Biocompatible Materials, Cell Division, Humans, Ligaments, Orthopedics, Polyglycolic Acid, Polymers, Sterilization, Sutures, Tendons, Lactic Acid, Prostheses and Implants, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.