Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/ polyglycolic acid copolymers
The DOI matches its Crossref record; 103 of the 104 references it cites were found in a registry or an index.
Abstract
This is a review of salient studies of sterilization, toxicity, biocompatibility, clinical applications and current work in the field of orthopaedics, using implants made of polylactic acid (PLA), polyglycolic acid (PGA) and their copolymers. The intrinsic nature of these biomaterials renders them suitable for applications where temporally slow releases of bioactive agents in situ may be required. They are also desirable as fixation devices of bone, because they can virtually eliminate osteopenia associated with stress shielding or additional surgery. The majority of currently available sterilization techniques are not suitable for these thermoplastic materials and it may be desirable to develop new sterilization standards, which can account for the special character of PLA-PGA materials. Biocompatibility and toxicity studies suggest that, overall, PLA-PGA biomaterials may be suitable for orthopaedic applications, although certain problems, especially pertaining to reduction in cell proliferation, have been reported. Clinical applications are also promising, albeit not without problems usually associated with transient tissue inflammation. The future of these materials appears bright, especially in soft tissues. They may be used to address the exceedingly complex problem of osteochondral repair, but also as a means to enhance fixation and repair processes in tendons and ligaments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PLA has been used in combination with PGA as effective clinical scaffolds since the 1960s, with varying FBR responses depending on the type of host, material concentrations, and implantation site.[ 197 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [197]
In the citing paper
“The degradation of polylactic acid is contingent on many factors, including time, temperature, low-molecular-weight impurities, and catalyst concentration [27,55,56].”
From Synthesis and Biological Application of Polylactic Acid (2020) · cites this paper as [27]
Citations
Cites
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Neocartilage formation in vitro and in vivo using cells cultured on synthetic biodegradable polymers
Freed, L. E., Marquis, J. C., Nohria, A., Emmanual, J., Mikos, A. G., & Langer, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270104 · Cited by 952
Polylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Biodegradable poly(lactic acid) polymers
Kulkarni, R. K., Moore, E. G., Hegyeli, A. F., & Leonard, F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050305 · Cited by 799
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Laminated three-dimensional biodegradable foams for use in tissue engineering
Mikos, A. G., Sarakinos, G., Leite, S. M., Vacant, J. P., & Langer, R. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90049-8 · Cited by 666
Preparation of poly(glycolic acid) bonded fiber structures for cell attachment and transplantation
Mikos, A. G., Bao, Y., Cima, L. G., Ingber, D. E., Vacanti, J. P., & Langer, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270207 · Cited by 606
Frazza, E. J., & Schmitt, E. E. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050207 · Cited by 572
Bergsma, E. J., Rozema, F. R., Bos, R. R. M., & Bruijn, W. C. D. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80267-8 · Cited by 541
Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
Bostman, O., Hirvensalo, E., Makinen, J., & Rokkanen, P. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b4.2199452 · Cited by 526
Research works printed but not linked: 6
- van Sliedregt, 1990, The effect of the molecular weight of polylactic acid on in vitro biocompatibility, Adv Biomater, 9, 207
- Athanasiou, 1992, The use of biodegradable implants for repairing large articular cartilage defects in the rabbit, Trans Orthop Res Soc, 17, 172
- Athanasiou, 1993, Biodegradable carriers of TGF-β in rabbit osteochondral defects, Trans Orthop Res Soc, 18, 288
- Hirvensalo, 1988, Biodegradable fixation in intraarticulate fractures of the elbow joint, Acta Orthop Scand Suppl, 227, 78
- Hoffmann, 1989, Die distale Radiusfraktur. Frakturstabilisierung mit biodegradablen Osteosynthes Stiften (Biofix), Exper Unters Klinische Erfahrungen, 92, 430
- Agrawal, 1994, In vitro protein release characteristics of a bioabsorbable carrier of BMP for fracture non-unions, Trans ORS, 19, 602
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Electrospun nanofibrous structure: A novel scaffold for tissue engineering
Li, W., Laurencin, C. T., Caterson, E. J., Tuan, R. S., & Ko, F. K. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10167 · Cited by 2,427
Controlled Ring-Opening Polymerization of Lactide and Glycolide
Dechy-Cabaret, O., Martin-Vaca, B., & Bourissou, D. (2004) · Chemical Reviews · doi:10.1021/cr040002s · Cited by 2,257
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204
Suchanek, W., & Yoshimura, M. (1998) · Journal of Materials Research · doi:10.1557/jmr.1998.0015 · Cited by 2,028
Application of chitosan-based polysaccharide biomaterials in cartilage tissue engineering: a review
Francis Suh, J.-K., & Matthew, H. W. T. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00126-5 · Cited by 1,997
“[38] Athanasiou KA, Niederauer GG, Agrawal CM.”
An Overview of Poly(lactic-co-glycolic) Acid (PLGA)-Based Biomaterials for Bone Tissue Engineering
Gentile, P., Chiono, V., Carmagnola, I., & Hatton, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15033640 · Cited by 1,593
“Poly (L-lactideco-glycolide) 10/90 [39,40]”
Recent Developments in Ring Opening Polymerization of Lactones for Biomedical Applications
Albertsson, A.-C., & Varma, I. K. (2003) · Biomacromolecules · doi:10.1021/bm034247a · Cited by 1,582
Polymeric Scaffolds for Bone Tissue Engineering
Liu, X., & Ma, P. X. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000017544.36001.8e · Cited by 1,345
Therapeutic efficacy of nanoparticles and routes of administration
Chenthamara, D., Subramaniam, S., Ramakrishnan, S. G., Krishnaswamy, S., Essa, M. M., Lin, F.-H., & Qoronfleh, M. W. (2019) · Biomaterials Research · doi:10.1186/s40824-019-0166-x · Cited by 1,055
Synthetic nano-scale fibrous extracellular matrix
Ma, P. X., & Zhang, R. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1<60::aid-jbm7>3.0.co;2-h · Cited by 1,049
Regenerative Endodontics: A Review of Current Status and a Call for Action
Murray, P. E., Garcia-Godoy, F., & Hargreaves, K. M. (2007) · Journal of Endodontics · doi:10.1016/j.joen.2006.09.013 · Cited by 1,000
Biodegradable polymeric scaffolds for musculoskeletal tissue engineering
Agrawal, C. M., & Ray, R. B. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<141::aid-jbm1000>3.0.co;2-j · Cited by 1,052
Self-citationMethods for the Preparation and Manufacture of Polymeric Nanoparticles
Vauthier, C., & Bouchemal, K. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9800-3 · Cited by 929
Stem cell-based tissue engineering with silk biomaterials
Wang, Y., Kim, H.-J., Vunjak-Novakovic, G., & Kaplan, D. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.008 · Cited by 968
“Most synthetic polymers used in cartilage tissue engineering, especially the widely used polyesters like poly(lactide) (PLA), poly(glycolide) (PGA), or the copolymer poly(lactide-co-glycolide) (PLGA), induce some inflammation in vivo [161,162].”
BackgroundBiocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Current advances in research and clinical applications of PLGA-based nanotechnology
Lü, J.-M., Wang, X., Marin-Muller, C., Wang, H., Lin, P. H., Yao, Q., & Chen, C. (2009) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.09.15 · Cited by 903
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
“Biodegradation, no aggregation and lack of cytotoxic response are the main advantages of using PGA as a degradable biomaterial [231,232].”
BackgroundThe inflammatory responses to silk films in vitro and in vivo
Meinel, L., Hofmann, S., Karageorgiou, V., Kirker-Head, C., McCool, J., Gronowicz, G., Zichner, L., Langer, R., Vunjak-Novakovic, G., & Kaplan, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.047 · Cited by 786
Biodegradable Polymers-A Review on Recent Trends and Emerging Perspectives
Luckachan, G. E., & Pillai, C. K. S. (2011) · Journal of Polymers and the Environment · doi:10.1007/s10924-011-0317-1 · Cited by 767
Desmet, T., Morent, R., De Geyter, N., Leys, C., Schacht, E., & Dubruel, P. (2009) · Biomacromolecules · doi:10.1021/bm900186s · Cited by 689
Collagen-Hydroxyapatite Composites for Hard Tissue Repair
Department of Materials, U. O. O., Wahl, D., & Czernuszka, J. (2006) · European Cells and Materials · doi:10.22203/ecm.v011a06 · Cited by 675
“The reader is referred to Athanasiou et al. (1996) for a review in the biocompatibility of such polymeric materials.”
BackgroundA review on biodegradable polymeric materials for bone tissue engineering applications
Sabir, M. I., Xu, X., & Li, L. (2009) · Journal of Materials Science · doi:10.1007/s10853-009-3770-7 · Cited by 645
Saito, N., Okada, T., Toba, S., Miyamoto, S., & Takaoka, K. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199910)47:1<104::aid-jbm15>3.0.co;2-7 · Cited by 78
Porous biodegradable polymeric scaffolds prepared by thermally induced phase separation
Nam, Y. S., & Park, T. G. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199910)47:1<8::aid-jbm2>3.0.co;2-l · Cited by 650
Biocompatibility and safety of PLA and its copolymers
Ramot, Y., Haim-Zada, M., Domb, A. J., & Nyska, A. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.012 · Cited by 576
Nanomedicine for implants: A review of studies and necessary experimental tools
Liu, H., & Webster, T. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.049 · Cited by 579
“That is, while the natural tissue regenerates, these polymers degrade in vivo by hydrolysis into nontoxic, natural metabolites (specifically, lactic acid, and glycolic acid) which enter into normal metabolic pathways of the tricarboxylic acid cycle to be eventually eliminated from the body in the form of carbon dioxid…”
BackgroundBiomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
“Numerous synthetic polymeric materials have been employed as coating materials, e.g., poly(lactic-acid) and poly(lactic co-glycolic acid) (PLGA) ( 57 ,58), poly(ethylene-glycol), 2-hydroxyethyl methacrylate (59), poly(ethylene glycol) (PEG) (60), and poly(vinylalcohol)(PVA)(61,62).Knowledgeof thephysicalandchemical pr…”
BackgroundIn vivo biocompatibility and degradability of a novel injectable-chitosan-based implant
Mi, F.-L., Tan, Y.-C., Liang, H.-F., & Sung, H.-W. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00094-1 · Cited by 545
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Poly(lactic acid) nanofibrous scaffolds for tissue engineering
Santoro, M., Shah, S. R., Walker, J. L., & Mikos, A. G. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.019 · Cited by 485
Synthesis and Biological Application of Polylactic Acid
Li, G., Zhao, M., Xu, F., Yang, B., Li, X., Meng, X., Teng, L., Sun, F., & Li, Y. (2020) · Molecules · doi:10.3390/molecules25215023 · Cited by 492
“Only a few manufacturers use this method due to the expensive raw materials [27].”
BackgroundMethodTendon healing in a bone tunnel. Part II
Weiler, A., Hoffmann, R. F. G., Bail, H. J., Rehm, O., & Südkamp, N. P. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30657 · Cited by 481
Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering
Brydone, A. S., Meek, D., & Maclaine, S. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim770 · Cited by 456
Polylactide-co-glycolide nanoparticles for controlled delivery of anticancer agents
Dinarvand, R., Sepehri, N., Manouchehri, Rouhani, & Atyabi, F. (2011) · International Journal of Nanomedicine · doi:10.2147/ijn.s18905 · Cited by 453
Polylactic acid (PLA): Research, development and industrialization
Pang, X., Zhuang, X., Tang, Z., & Chen, X. (2010) · Biotechnology Journal · doi:10.1002/biot.201000135 · Cited by 435
“Moreover, the ultimate degradation product of PLA is lactic acid, which is then incorporated into tricarboxylic acid cycle and excreted, showing non-toxicity [74].”
BackgroundIn vivo bioresponses to silk proteins
Thurber, A. E., Omenetto, F. G., & Kaplan, D. L. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.039 · Cited by 453
Biodegradable Materials for Bone Repairs: A Review
Tan, L., Yu, X., Wan, P., & Yang, K. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.002 · Cited by 431
Mano, J. F., Sousa, R. A., Boesel, L. F., Neves, N. M., & Reis, R. L. (2004) · Composites Science and Technology · doi:10.1016/j.compscitech.2003.09.001 · Cited by 450
“poly(dl-lactic-co-glycolic acid) (PLGA) are among the few synthetic polymers approved for human clinical uses, including those for small load-bearing applications [118,119].”
BackgroundWang, Y., Kim, U.-J., Blasioli, D. J., Kim, H.-J., & Kaplan, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.022 · Cited by 436
Linhart, W., Peters, F., Lehmann, W., Schwarz, K., Schilling, A. F., Amling, M., Rueger, J. M., & Epple, M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200102)54:2<162::aid-jbm2>3.0.co;2-3 · Cited by 181
Ma, P. X., Zhang, R., Xiao, G., & Franceschi, R. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200102)54:2<284::aid-jbm16>3.0.co;2-w · Cited by 429
Comparing Microfluidic Performance of Three-Dimensional (3D) Printing Platforms
Macdonald, N. P., Cabot, J. M., Smejkal, P., Guijt, R. M., Paull, B., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00136 · Cited by 425
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
Formation of highly porous biodegradable scaffolds for tissue engineering
Mikos, A. G., & Temenoff, J. S. (2000) · Electronic Journal of Biotechnology · doi:10.2225/vol3-issue2-fulltext-5 · Cited by 426
Scaffolds for Tissue Engineering and 3D Cell Culture
Carletti, E., Motta, A., & Migliaresi, C. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-60761-984-0_2 · Cited by 387
Zhou, H., Liang, B., Jiang, H., Deng, Z., & Yu, K. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.03.004 · Cited by 377
Ilyas, R., Zuhri, M., Aisyah, H., Asyraf, M., Hassan, S., Zainudin, E., Sapuan, S., Sharma, S., Bangar, S., Jumaidin, R., et al. (2022) · Polymers · doi:10.3390/polym14010202 · Cited by 369
“PLA is broken down into α-hydroxy acid when implanted in living organisms and is then merged into the tricarboxylic acid cycle before being excreted [68,69].”
BackgroundMethodApproaches to neural tissue engineering using scaffolds for drug delivery
Willerth, S. M., & Sakiyama-Elbert, S. E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.014 · Cited by 392
Issues in long-term protein delivery using biodegradable microparticles
Ye, M., Kim, S., & Park, K. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.05.011 · Cited by 386
Alizadeh-Osgouei, M., Li, Y., & Wen, C. (2019) · Bioactive Materials · doi:10.1016/j.bioactmat.2018.11.003 · Cited by 356
Klämpfl, T. G., Isbary, G., Shimizu, T., Li, Y.-F., Zimmermann, J. L., Stolz, W., Schlegel, J., Morfill, G. E., & Schmidt, H.-U. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.00583-12 · Cited by 367
“This can influence the physical and biological performance of the medical device (36), leading to material failure (2).”
BackgroundXin, X., Hussain, M., & Mao, J. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.042 · Cited by 377
“Poly(D,L-lactide-co-glycolide) (PLGA) has been approved for several biomedical applications in humans and widely used as scaffold materials in tissue engineering [47–49].”
Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353
Biodegradable 3D printed polymer microneedles for transdermal drug delivery
Luzuriaga, M. A., Berry, D. R., Reagan, J. C., Smaldone, R. A., & Gassensmith, J. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00098k · Cited by 356
Silk-based biomaterials for sustained drug delivery
Yucel, T., Lovett, M. L., & Kaplan, D. L. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.059 · Cited by 359
Ouyang, H. W., Goh, J. C. H., Thambyah, A., Teoh, S. H., & Lee, E. H. (2003) · Tissue Engineering · doi:10.1089/107632703322066615 · Cited by 356
“10 Our previous work showed that bone marrow stromal cells (bMSCs) adhered to and grew faster on poly-lactide-co-glycolide (PLGA) film than on polycaprolactone (PCL), polylactic acid (PLA), or their copolymer films.”
Engineering bone‐like tissue in vitro using human bone marrow stem cells and silk scaffolds
Meinel, L., Karageorgiou, V., Hofmann, S., Fajardo, R., Snyder, B., Li, C., Zichner, L., Langer, R., Vunjak‐Novakovic, G., & Kaplan, D. L. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30117 · Cited by 349
“Polymeric scaffolds used for bone tissue engineering, such as poly(lactic-co-glycolic acid) or poly-L-lactic acid can induce inflammation due to the acidity of their hydrolysis products.(9,10) Moreover, matching mechanical properties of native bone remains an issue with most polyesters.”
BackgroundAn overview of the suitability of hydrogel-forming polymers for extrusion-based 3D-printing
Kirchmajer, D. M., Gorkin III, R., & in het Panhuis, M. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00393h · Cited by 337
PLA Nano‐ and Microparticles for Drug Delivery: An Overview of the Methods of Preparation
Lassalle, V., & Ferreira, M. L. (2007) · Macromolecular Bioscience · doi:10.1002/mabi.200700022 · Cited by 340
Cuiffo, M. A., Snyder, J., Elliott, A. M., Romero, N., Kannan, S., & Halada, G. P. (2017) · Applied Sciences · doi:10.3390/app7060579 · Cited by 324
Hydroxyapatite Based Materials for Bone Tissue Engineering: A Brief and Comprehensive Introduction
Shi, H., Zhou, Z., Li, W., Fan, Y., Li, Z., & Wei, J. (2021) · Crystals · doi:10.3390/cryst11020149 · Cited by 310
“Polylactic acid (PLA) is a kind of linear aliphatic thermoplastic biodegradable polyester with good mechanical properties, thermoplastic and biocompatibility, and is easy to prepare [90].”
BackgroundEvolution of Bioinks and Additive Manufacturing Technologies for 3D Bioprinting
Jose, R. R., Rodriguez, M. J., Dixon, T. A., Omenetto, F., & Kaplan, D. L. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00088 · Cited by 302
Pan, R., Xuan, W., Chen, J., Dong, S., Jin, H., Wang, X., Li, H., & Luo, J. (2018) · Nano Energy · doi:10.1016/j.nanoen.2017.12.048 · Cited by 308
Engineering cartilage‐like tissue using human mesenchymal stem cells and silk protein scaffolds
Meinel, L., Hofmann, S., Karageorgiou, V., Zichner, L., Langer, R., Kaplan, D., & Vunjak‐Novakovic, G. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20252 · Cited by 310
“Although frequently used for tissue engineering, polyesters can induce inflammation due to the acidity of their hydrolysis products (Athanasiou et al., 1996; Hollinger et al., 1996).”
BackgroundCalcium orthophosphate-based biocomposites and hybrid biomaterials
Dorozhkin, S. V. (2009) · Journal of Materials Science · doi:10.1007/s10853-008-3124-x · Cited by 300
Rizzi, S. C., Heath, D. J., Coombes, A. G. A., Bock, N., Textor, M., & Downes, S. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20010615)55:4<475::aid-jbm1039>3.0.co;2-q · Cited by 302
Cohen-Sela, E., Chorny, M., Koroukhov, N., Danenberg, H. D., & Golomb, G. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.09.073 · Cited by 285
Three-dimensional printing surgical instruments: are we there yet?
Rankin, T. M., Giovinco, N. A., Cucher, D. J., Watts, G., Hurwitz, B., & Armstrong, D. G. (2014) · Journal of Surgical Research · doi:10.1016/j.jss.2014.02.020 · Cited by 275
“when compared with other chemical sterilants [11].”
Liao, C., Chen, C., Chen, J., Chiang, S., Lin, Y., & Chang, K. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10030 · Cited by 283
Preparation and characterization of sterile and freeze-dried sub-200 nm nanoparticles
Konan, Y. N., Gurny, R., & Allémann, E. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00944-9 · Cited by 279
Dong, J., Sun, Q., & Wang, J.-Y. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.084 · Cited by 272
Iodinated blood pool contrast media for preclinical X-ray imaging applications – A review
Hallouard, F., Anton, N., Choquet, P., Constantinesco, A., & Vandamme, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.066 · Cited by 265
Xu, C., Yang, F., Wang, S., & Ramakrishna, S. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30143 · Cited by 267
Bhattarai, D. P., Aguilar, L. E., Park, C. H., & Kim, C. S. (2018) · Membranes · doi:10.3390/membranes8030062 · Cited by 261
“PGA and PLA have been copolymerized to control over the degradation rate for a specific application in bone tissue engineering [134].”
BackgroundCalvert, J. W., Marra, K. G., Cook, L., Kumta, P. N., DiMilla, P. A., & Weiss, L. E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<279::aid-jbm6>3.0.co;2-8 · Cited by 107
Synthetic nano-fibrillar extracellular matrices with predesigned macroporous architectures
Zhang, R., & Ma, P. X. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<430::aid-jbm25>3.0.co;2-l · Cited by 264
Recent Trends in the Development of Bone Regenerative Biomaterials
Tang, G., Liu, Z., Liu, Y., Yu, J., Wang, X., Tan, Z., & Ye, X. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.665813 · Cited by 242
“…(PCL), and poly(lactic-co-glycolic acid) (PLGA) are widely used in the form of scaffold materials, but their degradation products may cause the proliferation of degradation rate and the occurrence of inflammatory reaction (Athanasiou, 1996; Woodruff and Hutmacher, 2010; Danhier et al., 2012).”
BackgroundDrug delivery vehicles on a nano-engineering perspective
Felice, B., Prabhakaran, M. P., Rodríguez, A. P., & Ramakrishna, S. (2014) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.04.049 · Cited by 253
Surface Modification of 3D Printed PLA Objects by Fused Deposition Modeling: A Review
Baran, E. H., & Erbil, H. Y. (2019) · Colloids and Interfaces · doi:10.3390/colloids3020043 · Cited by 248
“It does not produce toxic or carcinogenic effects in local tissues and the degradation products should not interfere with tissue healing [2,4,17,23].”
BackgroundToxicological considerations when creating nanoparticle-based drugs and drug delivery systems
Sharma, A., Madhunapantula, S. V., & Robertson, G. P. (2012) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425255.2012.637916 · Cited by 242
Recent Advances in Biodegradable Metals for Medical Sutures: A Critical Review
Seitz, J., Durisin, M., Goldman, J., & Drelich, J. W. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500189 · Cited by 243
Application of montmorillonite in bentonite as a pharmaceutical excipient in drug delivery systems
Park, J.-H., Shin, H.-J., Kim, M. H., Kim, J.-S., Kang, N., Lee, J.-Y., Kim, K.-T., Lee, J. I., & Kim, D.-D. (2016) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-016-0258-8 · Cited by 229
“Polyesters, including polyglycolic acid, polylactic acid, polycaprolactone, and poly(lactic-co-glycolic acid) are biodegradable, biocompatible, and thermoplastic polymers that can be prepared by ring-opening polymerization of cyclic diesters (Athanasiou et al.”
BackgroundTendon healing in a bone tunnel. Part I
Weiler, A., Peine, R., Pashmineh-Azar, A., Abel, C., Südkamp, N. P., & Hoffmann, R. F. G. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30656 · Cited by 243
Oliveira, J. E., Mattoso, L. H. C., Orts, W. J., & Medeiros, E. S. (2013) · Advances in Materials Science and Engineering · doi:10.1155/2013/409572 · Cited by 242
“Selection of the PLA stereochemistry can have a major effect on the polymer properties, processability, and biodegradability [45].”
BackgroundImmune system targeting by biodegradable nanoparticles for cancer vaccines
Silva, J. M., Videira, M., Gaspar, R., Préat, V., & Florindo, H. F. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.03.010 · Cited by 233
Perka, C., Schultz, O., Spitzer, R.-S., Lindenhayn, K., Burmester, G.-R., & Sittinger, M. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00280-x · Cited by 241
Synthesis and Characterization of Poly(D,L-Lactide-co-Glycolide) Copolymer
D’Avila Carvalho Erbetta, C. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.32027 · Cited by 233
“The use of (D,LPLA) is preferred in a DDS system, as the drug can be more homogeneously distributed through the polymer matrix [29].”
MethodDevelopment of biodegradable electrospun scaffolds for dermal replacement
Blackwood, K. A., McKean, R., Canton, I., Freeman, C. O., Franklin, K. L., Cole, D., Brook, I., Farthing, P., Rimmer, S., Haycock, J. W., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.037 · Cited by 229
Silk based biomaterials to heal critical sized femur defects
Meinel, L., Betz, O., Fajardo, R., Hofmann, S., Nazarian, A., Cory, E., Hilbe, M., McCool, J., Langer, R., Vunjak-Novakovic, G., et al. (2006) · Bone · doi:10.1016/j.bone.2006.04.019 · Cited by 234
“Polymeric scaffolds used for bone tissue engineering, such as poly(lactic-co-glycolic acid) or poly-Llactic acid, can induce inflammation due to the acidity of their hydrolysis products [6,17].”
Biodegradable Implants in Sports Medicine: The Biological Base
Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., Helling, H.-J., & Südkamp, N. P. (2000) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(00)90055-0 · Cited by 236
Naturally derived and synthetic scaffolds for skeletal muscle reconstruction
Wolf, M. T., Dearth, C. L., Sonnenberg, S. B., Loboa, E. G., & Badylak, S. F. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.08.011 · Cited by 230
“lactic acid and glycolic acid) [75,76], PLGA is a popular source for an implantable material used in devices such as biodegradable sutures in addition to tissue engineering scaffolds [77].”
BackgroundDeng, Y., Zhao, K., Zhang, X.-F., Hu, P., & Chen, G.-Q. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00136-9 · Cited by 230
“Both natural and synthetic scaffolds for tissue engineering provide a matrix onto which cells may adhere and aid in shaping and defining in vivo cell growth [30–31].”
BackgroundPorous Biodegradable Metals for Hard Tissue Scaffolds: A Review
Yusop, A. H., Bakir, A. A., Shaharom, N. A., Abdul Kadir, M. R., & Hermawan, H. (2012) · International Journal of Biomaterials · doi:10.1155/2012/641430 · Cited by 225
“in concert with tissue regeneration [18–21].”
Walter, E., Dreher, D., Kok, M., Thiele, L., Kiama, S. G., Gehr, P., & Merkle, H. P. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00413-8 · Cited by 230
Carrier-free nanodrugs for safe and effective cancer treatment
Karaosmanoglu, S., Zhou, M., Shi, B., Zhang, X., Williams, G. R., & Chen, X. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.10.014 · Cited by 222
Control of Crystal Morphology in Poly(l-lactide) by Adding Nucleating Agent
Bai, H., Zhang, W., Deng, H., Zhang, Q., & Fu, Q. (2011) · Macromolecules · doi:10.1021/ma102439t · Cited by 221
Scaffolds for the manufacture of cultured meat
Seah, J. S. H., Singh, S., Tan, L. P., & Choudhury, D. (2022) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2021.1931803 · Cited by 209
Biodegradable polymeric microspheres and nanospheres for drug delivery in the peritoneum
Kohane, D. S., Tse, J. Y., Yeo, Y., Padera, R., Shubina, M., & Langer, R. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30654 · Cited by 217
Metadata
- Authors
- Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M.
- Affiliations
- The University of Texas at San Antonio Health Science Center (US)
- Corresponding author
- Athanasiou, Kyriacos A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 17
- Issue
- 2
- Pages
- 93-102
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2015639818
- Cited by
- 1,497
- References
- 104
- Citations by year
- 2026: 19 · 2025: 36 · 2024: 43 · 2023: 57 · 2022: 53 · 2021: 57 · 2020: 66 · 2019: 60 · 2018: 56 · 2017: 91 · 2016: 87 · 2015: 62 · 2014: 75 · 2013: 81 · 2012: 81
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- polylactic acid, polyglycolic acid, sterilization, biocompatibility, toxicity, orthopedic implants, bone fixation, stress shielding, osteopenia, cell proliferation, tissue inflammation, osteochondral repair
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Biocompatible Materials, Cell Division, Humans, Ligaments, Orthopedics, Polyglycolic Acid, Polymers, Sterilization, Sutures, Tendons, Lactic Acid, Prostheses and Implants, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.