Position and orientation in space of bones during movement: experimental artefacts
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This paper deals with the experimental problems related to the reconstruction of the position and orientation of the lower limb bones in space during the execution of locomotion and physical exercises. The inaccuracies associated with the relative movement between markers and underlying bone are analysed. Quantitative information regarding this movement was collected by making experiments on subjects who had suffered fractures and were wearing either femoral or tibial external fixators. These latter devices provided frames that were reliably rigid with the bone involved, and hence the possibility of assessing the relative movement between markers mounted on the skin and this bone. Anatomical frames associated with thigh and shank were reconstructed using technical frames based on different clusters of skin markers and their rotation with respect to the relevant bone evaluated. Marker movement was also assessed in subjects with intact musculoskeletal structures using digital videofluoroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Self-citationDetermining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735
Rigid body motion calculated from spatial co-ordinates of markers
Spoor, C. W., & Veldpaus, F. E. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90020-2 · Cited by 579
A least-squares algorithm for the equiform transformation from spatial marker co-ordinates
Veldpaus, F. E., Woltring, H. J., & Dortmans, L. J. M. G. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90190-x · Cited by 422
Cappozzo, A. (1984) · Human Movement Science · doi:10.1016/0167-9457(84)90004-6 · Cited by 361
Self-citation3-D attitude representation of human joints: A standardization proposal
Woltring, H. J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90191-0 · Cited by 251
A solidification procedure to facilitate kinematic analyses based on video system data
Chèze, L., Fregly, B. J., & Dimnet, J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95278-d · Cited by 222
D'Amico, M., & Ferrigno, G. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441963 · Cited by 162
Biomechanics of human movement: Applications in rehabilitation, sports and ergonomics
Kadaba, M. P. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90011-b · Cited by 114
Cited by
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Self-citationLu, T.-W., & O’Connor, J. J. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00158-4 · Cited by 924
Hicks, J. L., Uchida, T. K., Seth, A., Rajagopal, A., & Delp, S. L. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029304 · Cited by 748
Abnormal Rotational Knee Motion during Running after Anterior Cruciate Ligament Reconstruction
Tashman, S., Collon, D., Anderson, K., Kolowich, P., & Anderst, W. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261709 · Cited by 722
Colyer, S. L., Evans, M., Cosker, D. P., & Salo, A. I. T. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0139-y · Cited by 629
Dynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study
Karduna, A. R., McClure, P. W., Michener, L. A., & Sennett, B. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1351892 · Cited by 622
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Human movement analysis using stereophotogrammetry
Della Croce, U., Leardini, A., Chiari, L., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.003 · Cited by 544
Self-citationDorn, T. W., Schache, A. G., & Pandy, M. G. (2012) · Journal of Experimental Biology · doi:10.1242/jeb.064527 · Cited by 535
A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics
Andriacchi, T. P., Alexander, E. J., Toney, M. K., Dyrby, C., & Sum, J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834888 · Cited by 495
Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo
Benoit, D. L., Ramsey, D. K., Lamontagne, M., Xu, L., Wretenberg, P., & Renström, P. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.04.012 · Cited by 489
Effect of skin movement on the analysis of skeletal knee joint motion during running
Reinschmidt, C., van den Bogert, A. J., Nigg, B. M., Lundberg, A., & Murphy, N. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00001-8 · Cited by 475
Surface-marker cluster design criteria for 3-D bone movement reconstruction
Cappozzo, A., Cappello, A., Croce, U. D., & Pensalfini, F. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649988 · Cited by 456
Self-citationEffect of Gender and Defensive Opponent on the Biomechanics of Sidestep Cutting
MCLEAN, S. G., LIPFERT, S. W., & VAN DEN BOGERT, A. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128180.51443.83 · Cited by 449
OpenCap: Human movement dynamics from smartphone videos
Uhlrich, S. D., Falisse, A., Kidziński, Ł., Muccini, J., Ko, M., Chaudhari, A. S., Hicks, J. L., & Delp, S. L. (2023) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1011462 · Cited by 449
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
Self-citationMündermann, L., Corazza, S., & Andriacchi, T. P. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-6 · Cited by 387
Wade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022) · PeerJ · doi:10.7717/peerj.12995 · Cited by 384
New least squares solutions for estimating the average centre of rotation and the axis of rotation
Gamage, S. S. H. U., & Lasenby, J. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00160-9 · Cited by 376
Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review
Peters, A., Galna, B., Sangeux, M., Morris, M., & Baker, R. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.09.004 · Cited by 367
Harrington, M. E., Zavatsky, A. B., Lawson, S. E. M., Yuan, Z., & Theologis, T. N. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.003 · Cited by 365
Data management in gait analysis for clinical applications
Benedetti, M., Catani, F., Leardini, A., Pignotti, E., & Giannini, S. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00041-7 · Cited by 326
Self-citationMuscle and Joint Function in Human Locomotion
Pandy, M. G., & Andriacchi, T. P. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105259 · Cited by 325
Corazza, S., Mündermann, L., Chaudhari, A. M., Demattio, T., Cobelli, C., & Andriacchi, T. P. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9122-8 · Cited by 325
Tashman, S., & Anderst, W. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1559896 · Cited by 305
Gait analysis in children with cerebral palsy
Armand, S., Decoulon, G., & Bonnefoy-Mazure, A. (2016) · EFORT Open Reviews · doi:10.1302/2058-5241.1.000052 · Cited by 298
Manal, K., McClay, I., Stanhope, S., Richards, J., & Galinat, B. (2000) · Gait & Posture · doi:10.1016/s0966-6362(99)00042-9 · Cited by 284
Stagni, R., Fantozzi, S., Cappello, A., & Leardini, A. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.11.012 · Cited by 283
Self-citationFern'ndez-Baena, A., Susin, A., & Lligadas, X. (2012) · 2012 Fourth International Conference on Intelligent Networking and Collaborative Systems · doi:10.1109/incos.2012.66 · Cited by 281
Capturing human motion using body‐fixed sensors: outdoor measurement and clinical applications
Aminian, K., & Najafi, B. (2004) · Computer Animation and Virtual Worlds · doi:10.1002/cav.2 · Cited by 280
An optimized protocol for hip joint centre determination using the functional method
Camomilla, V., Cereatti, A., Vannozzi, G., & Cappozzo, A. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.02.008 · Cited by 269
Self-citationTibiofemoral and tibiocalcaneal motion during walking: external vs. skeletal markers
Reinschmidt, C., van den Bogert, A. J., Lundberg, A., Nigg, B. M., Murphy, N., Stacoff, A., & Stano, A. (1997) · Gait & Posture · doi:10.1016/s0966-6362(97)01110-7 · Cited by 257
An anatomically based protocol for the description of foot segment kinematics during gait
Leardini, A., Benedetti, M. G., Catani, F., Simoncini, L., & Giannini, S. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00008-x · Cited by 257
Self-citationDella Croce, U., Cappozzo, A., & Kerrigan, D. C. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513282 · Cited by 256
Self-citationStudies of human locomotion: past, present and future
Andriacchi, T. P., & Alexander, E. J. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00061-0 · Cited by 253
Correcting for deformation in skin-based marker systems
Alexander, E. J., & Andriacchi, T. P. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00192-5 · Cited by 253
Effects of hip joint centre mislocation on gait analysis results
Stagni, R., Leardini, A., Cappozzo, A., Grazia Benedetti, M., & Cappello, A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00093-2 · Cited by 241
Self-citationAkbarshahi, M., Schache, A. G., Fernandez, J. W., Baker, R., Banks, S., & Pandy, M. G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.002 · Cited by 232
“…most often used intrusive techniques for their analyses, such as bone pins (Fuller et al., 1997; Reinschmidt et al., 1997; Benoit et al., 2006), external fixators (Cappozzo et al., 1996) and percutaneous tracking devices (Holden et al., 1997; Manal et al., 2000) to quantify joint motion in vivo.”
BackgroundRistanis, S., Giakas, G., Papageorgiou, C. D., Moraiti, T., Stergiou, N., & Georgoulis, A. D. (2003) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-003-0428-x · Cited by 227
“Nevertheless, our results should be viewed in light of the general gait analysis limitations [6, 22].”
Effect of foot orthoses on the kinematics and kinetics of normal walking gait
Nester, C. J., van der Linden, M. L., & Bowker, P. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00065-6 · Cited by 221
“An additional factor influencing the data is the use of segmental wands, skin mounted markers and their documented effects on the eventual kinematic and joint moment data [27,38].”
BackgroundBiomechanics of human movement and its clinical applications
Lu, T., & Chang, C. (2012) · The Kaohsiung Journal of Medical Sciences · doi:10.1016/j.kjms.2011.08.004 · Cited by 218
“In order to reduce the effects of STA, several techniques in the literature have been used for measuring 3D skeletal kinematics, including the use of external fixators [39], intracortical pins [40] and percutaneous tracking devices [41], medical imaging methods [42e44], as well as model-based registration methods [45e…”
BackgroundMethodResearch approaches to describe the mechanisms of injuries in sport: limitations and possibilities
Krosshaug, T., Andersen, T. E., Olsen, O.-E. O., Myklebust, G., & Bahr, R. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.018358 · Cited by 215
Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics
Lucchetti, L., Cappozzo, A., Cappello, A., & Croce, U. D. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00083-9 · Cited by 211
“The artefacts affecting a BTF during movement, mostly originate from the rotations of the adjacent joints and are strongly correlated with them (Cappozzo et al., 1996).”
BackgroundSelf-citationAnalysis of squat and stoop dynamic liftings: muscle forces and internal spinal loads
Bazrgari, B., Shirazi-Adl, A., & Arjmand, N. (2007) · European Spine Journal · doi:10.1007/s00586-006-0240-7 · Cited by 202
“brae themselves [14, 56, 60, 87, 106].”
Inter-segment foot motion and ground reaction forces over the stance phase of walking
Hunt, A. E., M. Smith, R., Torode, M., & Keenan, A.-M. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00040-7 · Cited by 190
Dejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189
A model-based method for the reconstruction of total knee replacement kinematics
Zuffi, S., Leardini, A., Catani, F., Fantozzi, S., & Cappello, A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811310 · Cited by 185
“Recent papers from some of the authors have shown that the errors involved can be as large as few centimeters for joint translations and several degrees for rotations [4], [ 5 ].”
BackgroundSelf-citationKinematic analysis of over-determinate biomechanical systems
Andersen, M. S., Damsgaard, M., & Rasmussen, J. (2009) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840802459412 · Cited by 179
“Clinical assessment of the nature of STA has been subject to a lot of research in recent years (Cappozzo et al. 1996; Manal et al. 2000; Tayler et al. 2005; Stagni et al. 2005; Benoit et al. 2006).”
BackgroundOn the influence of soft tissue coverage in the determination of bone kinematics using skin markers
Taylor, W. R., Ehrig, R. M., Duda, G. N., Schell, H., Seebeck, P., & Heller, M. O. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2005.02.006 · Cited by 177
“may be measured using a variety of techniques such as percutaneous tracking markers combined with digital videofluroscopy [6,21] and bone pins [6,19], for example, the applicability of these methods is limited due to their invasive nature.”
BackgroundEffort-Shape and kinematic assessment of bodily expression of emotion during gait
Gross, M. M., Crane, E. A., & Fredrickson, B. L. (2012) · Human Movement Science · doi:10.1016/j.humov.2011.05.001 · Cited by 176
Charbonnier, C., Kolo, F. C., Duthon, V. B., Magnenat-Thalmann, N., Becker, C. D., Hoffmeyer, P., & Menetrey, J. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510386002 · Cited by 175
Stergiou, N., Ristanis, S., Moraiti, C., & Georgoulis, A. D. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00004 · Cited by 175
“As a result, error is introduced [22, 31-35] and unfortunately this error is difficult to be removed with low-pass filtering, since its frequency content is close to that of the motion.”
BackgroundTibiocalcaneal motion during running, measured with external and bone markers
Reinschmidt, C., van den Bogert, A., Murphy, N., Lundberg, A., & Nigg, B. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(96)00046-0 · Cited by 161
Multiple anatomical landmark calibration for optimal bone pose estimation
Cappello, A., Cappozzo, A., La Palombara, P. F., Lucchetti, L., & Leardini, A. (1997) · Human Movement Science · doi:10.1016/s0167-9457(96)00055-3 · Cited by 161
Self-citationUse of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
Chamroukhi, F., Mohammed, S., Trabelsi, D., Oukhellou, L., & Amirat, Y. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.04.003 · Cited by 88
“Other sensors are also used to recognize human activities such as videobased systems [9,10,3], goniometers [28], electromyography (EMG) [23], etc.”
BackgroundMethodBergmann, J. H., Mayagoitia, R. E., & Smith, I. C. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-3 · Cited by 88
Buganè, F., Benedetti, M., D’Angeli, V., & Leardini, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-146 · Cited by 54
Self-citationQuantification of Pelvic Soft Tissue Artifact in Multiple Static Positions
Hara, R., Sangeux, M., Baker, R., & McGinley, J. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.10.001 · Cited by 43
“Although many studies have investigated STA of the thigh, shank, or foot [4–13], knowledge of STA at the pelvis is particularly scarce.”
BackgroundWalicka-Cupryś, K., Wyszyńska, J., Podgórska-Bednarz, J., & Drzał-Grabiec, J. (2018) · European Spine Journal · doi:10.1007/s00586-017-5409-8 · Cited by 31
Buchman-Pearle, J. M., & Acker, S. M. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110659 · Cited by 10
Metadata
- Authors
- Cappozzo, A., Catani, F., Leardini, A., Benedetti, M., & Della Croce, U.
- Venue
- Clinical Biomechanics
- Publisher
- Elsevier BV
- Published
- 1996-03
- Volume
- 11
- Issue
- 2
- Pages
- 90-100
- ISSN
- 0268-0033 (ISSN-L)
- OpenAlex
- W2021407054
- Cited by
- 756
- References
- 12
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.