The use of power images to perform quantitative analysis on low SNR MR images
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Echo-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Cited by
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
MRI segmentation: Methods and applications
Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J. J., Vaidyanathan, M., Hall, L. O., Thatcher, R. W., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00124-l · Cited by 695
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Deistung, A., Schäfer, A., Schweser, F., Biedermann, U., Turner, R., & Reichenbach, J. R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.055 · Cited by 442
“…relaxation rate, R2⁎, were obtained using the powermethod, i.e., by fitting the squaredmagnitude signal decay, S2, of the 3D multi-echo GRE scan, according to McGibney and Smith (1993) and Miller and Joseph (1993): S2 TEð Þ ¼ S20 exp −2⋅TE⋅R 2 ; ð1Þ where S0 is the signal intensity at TE=0.”
Maximum-likelihood estimation of Rician distribution parameters
Sijbers, J., den Dekker, A. J., Scheunders, P., & Van Dyck, D. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712125 · Cited by 393
Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
Koay, C. G., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.01.016 · Cited by 312
Estimation of the Noise in Magnitude MR Images
Sijbers, J., den Dekker, A. J., Van Audekerke, J., Verhoye, M., & Van Dyck, D. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00199-9 · Cited by 277
Dietrich, O., Raya, J. G., Reeder, S. B., Ingrisch, M., Reiser, M. F., & Schoenberg, S. O. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.02.001 · Cited by 254
Diffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211
Gibbs, P., Tozer, D. J., Liney, G. P., & Turnbull, L. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1298 · Cited by 199
“Since the images acquired at high b-values exhibited low signalto-noise the diffusion data was modified prior to fitting by utilizing the noise correction scheme proposed by Miller and Joseph (21).”
MethodMagnetic resonance microimaging of intraaxonal water diffusion in live excised lamprey spinal cord
Takahashi, M., Hackney, D. B., Zhang, G., Wehrli, S. L., Wright, A. C., O'Brien, W. T., Uematsu, H., Wehrli, F. W., & Selzer, M. E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.252249999 · Cited by 189
He, T., Gatehouse, P. D., Smith, G. C., Mohiaddin, R. H., Pennell, D. J., & Firmin, D. N. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21744 · Cited by 175
Hametner, S., Endmayr, V., Deistung, A., Palmrich, P., Prihoda, M., Haimburger, E., Menard, C., Feng, X., Haider, T., Leisser, M., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.007 · Cited by 172
“R2* maps were calculated by mono-exponential fitting of the squared signal decay of the multi-echo GRE magnitude data using logarithmic calculus (McGibney and Smith, 1993; Miller and Joseph, 1993).”
Optic nerve diffusion tensor imaging in optic neuritis
Trip, S. A., Wheeler-Kingshott, C., Jones, S. J., Li, W.-Y., Barker, G. J., Thompson, A. J., Plant, G. T., & Miller, D. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.024 · Cited by 167
“Intraorbital slice from a 36-year-old female patient 2 years after left sided map, (D) principal eigenvalue k \\ map, and (E) one of two orthogonal eigenvalue noise correction of the signal intensity, before DT calculations (Miller and Joseph, 1993; Wheeler-Kingshott et al., 2002a).”
MethodLori, N. F., Akbudak, E., Shimony, J. S., Cull, T. S., Snyder, A. Z., Guillory, R. K., & Conturo, T. E. (2002) · NMR in Biomedicine · doi:10.1002/nbm.779 · Cited by 164
“However, the rms noise level in WM is not necessarily 1/ 10 1 in the 10frame averaged I0 or DWI images due to noise bias in low signal intensities(64) that occurs particularly in DWI.(76,77)”
BackgroundRaya, J. G., Dietrich, O., Horng, A., Weber, J., Reiser, M. F., & Glaser, C. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22178 · Cited by 163
Machann, J., Thamer, C., Schnoedt, B., Stefan, N., Haring, H., Claussen, C. D., Fritsche, A., & Schick, F. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20825 · Cited by 162
“where S ROI is the mean signal intensity of the chosen ROI, and S N is the mean signal from the object-free part (noise) (18).”
BackgroundA signal transformational framework for breaking the noise floor and its applications in MRI
Koay, C. G., Özarslan, E., & Basser, P. J. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.11.015 · Cited by 159
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10255 · Cited by 73
“Mean values were corrected for noise (33).”
Joseph, G. B., Nevitt, M. C., McCulloch, C. E., Neumann, J., Lynch, J. A., Heilmeier, U., Lane, N. E., & Link, T. M. (2018) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2018.04.019 · Cited by 29
Metadata
- Authors
- Miller, A. J., & Joseph, P. M.
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 1993-01
- Volume
- 11
- Issue
- 7
- Pages
- 1051-1056
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W2074373813
- Cited by
- 244
- References
- 4
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.