The DOI matches its Crossref record; 135 of the 135 references it cites were found in a registry or an index.
Osseointegration and current interpretations of the bone-implant interface
Open accessAbstract
Complex physical and chemical interactions take place in the interface between the implant surface and bone. Various descriptions of the ultrastructural arrangement to various implant design features, ranging from solid and macroporous geometries to surface modifications on the micron-, submicron-, and nano- levels, have been put forward. Here, the current knowledge regarding structural organisation of the bone-implant interface is reviewed with a focus on solid devices, mainly metal (or alloy) intended for permanent anchorage in bone. Certain biomaterials that undergo surface and bulk degradation are also considered. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin. In the published literature, as many as eight distinct arrangements of the bone-implant interface ultrastructure have been described. The interpretation is influenced by the in vivo model and species-specific characteristics, healing time point(s), physico-chemical properties of the implant surface, implant geometry, sample preparation route(s) and associated artefacts, analytical technique(s) and their limitations, and non-compromised vs compromised local tissue conditions. The understanding of the ultrastructure of the interface under experimental conditions is rapidly evolving due to the introduction of novel techniques for sample preparation and analysis. Nevertheless, the current understanding of the interface zone in humans in relation to clinical implant performance is still hampered by the shortcomings of clinical methods for resolving the finer details of the bone-implant interface. STATEMENT OF SIGNIFICANCE: Being a hierarchical material by design, the overall strength of bone is governed by composition and structure. Understanding the structure of the bone-implant interface is essential in the development of novel bone repair materials and strategies, and their long-term success. Here, the current knowledge regarding the eventual structural organisation of the bone-implant interface is reviewed, with a focus on solid devices intended for permanent anchorage in bone, and certain biomaterials that undergo surface and bulk degradation. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2 retracted
Interventions for replacing missing teeth: different types of dental implants
Esposito, M., Ardebili, Y., & Worthington, H. V. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003815.pub5 · Cited by 243
RetractedInterventions for replacing missing teeth: different types of dental implants
Esposito, M., Ardebili, Y., & Worthington, H. V. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003815.pub4 · Cited by 218
RetractedForeign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,800
Third-Generation Biomedical Materials
Hench, L. L., & Polak, J. M. (2002) · Science · doi:10.1126/science.1067404 · Cited by 2,789
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Bone Quality — The Material and Structural Basis of Bone Strength and Fragility
Seeman, E., & Delmas, P. D. (2006) · New England Journal of Medicine · doi:10.1056/nejmra053077 · Cited by 2,080
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
Evidence for osteocyte regulation of bone homeostasis through RANKL expression
Nakashima, T., Hayashi, M., Fukunaga, T., Kurata, K., Oh-hora, M., Feng, J. Q., Bonewald, L. F., Kodama, T., Wutz, A., Wagner, E. F., et al. (2011) · Nature Medicine · doi:10.1038/nm.2452 · Cited by 1,778
Donath, K., & Breuner, G. (1982) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1982.tb00172.x · Cited by 1,636
Bone structure and formation: A new perspective
Olszta, M. J., Cheng, X., Jee, S. S., Kumar, R., Kim, Y.-Y., Kaufman, M. J., Douglas, E. P., & Gower, L. B. (2007) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.05.001 · Cited by 1,563
Mechanical Stimulation of Bone in Vivo Reduces Osteocyte Expression of Sost/Sclerostin
Robling, A. G., Niziolek, P. J., Baldridge, L. A., Condon, K. W., Allen, M. R., Alam, I., Mantila, S. M., Gluhak-Heinrich, J., Bellido, T. M., Harris, S. E., et al. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m705092200 · Cited by 1,350
Understanding and controlling the bone–implant interface
Puleo, D. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00160-x · Cited by 1,342
Esposito, M., Hirsch, J., Lekholm, U., & Thomsen, P. (1998) · European Journal of Oral Sciences · doi:10.1046/j.0909-8836..t01-2-.x · Cited by 1,274
Self-citationNudelman, F., Pieterse, K., George, A., Bomans, P. H. H., Friedrich, H., Brylka, L. J., Hilbers, P. A. J., de With, G., & Sommerdijk, N. A. J. M. (2010) · Nature Materials · doi:10.1038/nmat2875 · Cited by 1,185
Understanding Peri‐Implant Endosseous Healing
Davies, J. E. (2003) · Journal of Dental Education · doi:10.1002/j.0022-0337.2003.67.8.tb03681.x · Cited by 1,063
Hench, L. L., & Wilson, J. (1984) · Science · doi:10.1126/science.6093253 · Cited by 982
Corrosion of Metal Orthopaedic Implants*
Jacobs, J. J., Gilbert, J. L., & Urban, R. M. (1998) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199802000-00015 · Cited by 967
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
The soft tissue barrier at implants and teeth
Berglundh, T., Lindhe, J., Ericsson, I., Marinello, C. P., Liljenberg, B., & Thornsen, P. (1991) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1991.020206.x · Cited by 901
Matsuno, H. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00275-1 · Cited by 828
Bone hierarchical structure in three dimensions
Reznikov, N., Shahar, R., & Weiner, S. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.05.024 · Cited by 698
Fractal-like hierarchical organization of bone begins at the nanoscale
Reznikov, N., Bilton, M., Lari, L., Stevens, M. M., & Kröger, R. (2018) · Science · doi:10.1126/science.aao2189 · Cited by 661
Donath, K. (1982) · Medical Entomology and Zoology · Cited by 643
Wang, Y., Azaïs, T., Robin, M., Vallée, A., Catania, C., Legriel, P., Pehau-Arnaudet, G., Babonneau, F., Giraud-Guille, M.-M., & Nassif, N. (2012) · Nature Materials · doi:10.1038/nmat3362 · Cited by 605
Regulatory mechanisms of osteoblast and osteoclast differentiation
Katagiri, T., & Takahashi, N. (2002) · Oral Diseases · doi:10.1034/j.1601-0825.2002.01829.x · Cited by 596
Bosshardt, D. D., Chappuis, V., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12179 · Cited by 574
Elliott, J. C. (1990) · FEBS Letters · doi:10.1016/0014-5793(90)80912-3 · Cited by 553
Osteocytes: master orchestrators of bone
Schaffler, M. B., Cheung, W.-Y., Majeska, R., & Kennedy, O. (2014) · Calcified Tissue International · doi:10.1007/s00223-013-9790-y · Cited by 514
Spatially resolved transcriptomics and beyond
Crosetto, N., Bienko, M., & van Oudenaarden, A. (2015) · Nature Reviews Genetics · doi:10.1038/nrg3832 · Cited by 509
The interface zone of inorganic implantsIn vivo: Titanium implants in bone
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., Kasemo, B., Larsson, K., Lundström, I., McQueen, D. H., & Skalak, R. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363944 · Cited by 436
Porter, A. E., Patel, N., Skepper, J. N., Best, S. M., & Bonfield, W. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00355-7 · Cited by 412
Osteocyte-Driven Bone Remodeling
Bellido, T. (2014) · Calcified Tissue International · doi:10.1007/s00223-013-9774-y · Cited by 384
Biomineralization : Chemical and Biochemical Perspectives
Mann, S., Webb, J. M., & Williams, R. J. (1989) · Medical Entomology and Zoology · Cited by 382
Titanium surface roughness alters responsiveness of MG63 osteoblast-like cells to 1?,25-(OH)2D3
Boyan, B. D., Batzer, R., Kieswetter, K., Liu, Y., Cochran, D. L., Szmuckler-Moncler, S., Dean, D. D., & Schwartz, Z. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199801)39:1<77::aid-jbm10>3.0.co;2-l · Cited by 370
Organization of hydroxyapatite crystals within collagen fibrils
Weiner, S., & Traub, W. (1986) · FEBS Letters · doi:10.1016/0014-5793(86)80993-0 · Cited by 325
OsteoMacs: Key players around bone biomaterials
Miron, R. J., & Bosshardt, D. D. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.12.017 · Cited by 321
Landis, W. J., Hodgens, K. J., Song, M. J., Arena, J., Kiyonaga, S., Marko, M., Owen, C., & McEwen, B. F. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0066 · Cited by 310
Bone bonding at natural and biomaterial surfaces
Davies, J. E. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.049 · Cited by 309
Red blood cell and platelet interactions with titanium implant surfaces
Park, J. Y., & Davies, J. E. (2000) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2000.011006530.x · Cited by 299
Burr, D. B., Schaffler, M. B., & Frederickson, R. G. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90132-7 · Cited by 298
Bone regeneration performance of surface-treated porous titanium
Amin Yavari, S., van der Stok, J., Chai, Y. C., Wauthle, R., Tahmasebi Birgani, Z., Habibovic, P., Mulier, M., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.054 · Cited by 297
Molecular and cellular biology of alveolar bone
SODEK, J., & MCKEE, M. D. (2000) · Periodontology 2000 · doi:10.1034/j.1600-0757.2000.2240106.x · Cited by 283
Titanium oral implants: surface characteristics, interface biology and clinical outcome
Palmquist, A., Omar, O. M., Esposito, M., Lausmaa, J., & Thomsen, P. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0118.focus · Cited by 258
Self-citationPorter, A. E., Patel, N., Skepper, J. N., Best, S. M., & Bonfield, W. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.006 · Cited by 250
Skedros, J. G., Holmes, J. L., Vajda, E. G., & Bloebaum, R. D. (2005) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20214 · Cited by 244
Effect of surface finish on the osseointegration of laser-treated titanium alloy implants
Götz, H. E., Müller, M., Emmel, A., Holzwarth, U., Erben, R. G., & Stangl, R. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.002 · Cited by 240
Effects of implant surface microtopography on osteoblast gene expression
Masaki, C., Schneider, G. B., Zaharias, R., Seabold, D., & Stanford, C. (2005) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01170.x · Cited by 239
Reznikov, N., Shahar, R., & Weiner, S. (2014) · Bone · doi:10.1016/j.bone.2013.10.023 · Cited by 232
The nanocomposite nature of bone drives its strength and damage resistance
Tertuliano, O. A., & Greer, J. R. (2016) · Nature Materials · doi:10.1038/nmat4719 · Cited by 227
Matrix Proteins and Mineralization: An Overview
Boskey, A. L. (1996) · Connective Tissue Research · doi:10.3109/03008209609029212 · Cited by 215
Implant Surface Roughness Affects Osteoblast Gene Expression
Schneider, G. B., Perinpanayagam, H., Clegg, M., Zaharias, R., Seabold, D., Keller, J., & Stanford, C. (2003) · Journal of Dental Research · doi:10.1177/154405910308200509 · Cited by 209
A Model for the Ultrastructure of Bone Based on Electron Microscopy of Ion-Milled Sections
McNally, E. A., Schwarcz, H. P., Botton, G. A., & Arsenault, A. L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029258 · Cited by 206
Osteopontin: An Interfacial Extracellular Matrix Protein in Mineralized Tissues
Mckee, M. D., & Nanci, A. (1996) · Connective Tissue Research · doi:10.3109/03008209609029192 · Cited by 202
Shah, F. A., Snis, A., Matic, A., Thomsen, P., & Palmquist, A. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.013 · Cited by 193
Self-citationInterface analysis of titanium and zirconium bone implants
Albrektsson, T. O., Hansson, H., & Ivarsson, B. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90070-5 · Cited by 188
Thormann, U., Ray, S., Sommer, U., ElKhassawna, T., Rehling, T., Hundgeburth, M., Henß, A., Rohnke, M., Janek, J., Lips, K. S., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.036 · Cited by 181
Ultrastructural characterization of the implant/bone interface of immediately loaded dental implants
Meyer, U., Joos, U., Mythili, J., Stamm, T., Hohoff, A., Fillies, T., Stratmann, U., & Wiesmann, H. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.070 · Cited by 175
Tan, K. S., Qian, L., Rosado, R., Flood, P. M., & Cooper, L. F. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.002 · Cited by 163
Surface immobilized bisphosphonate improves stainless-steel screw fixation in rats
Tengvall, P., Skoglund, B., Askendal, A., & Aspenberg, P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.049 · Cited by 158
Alexander, B., Daulton, T. L., Genin, G. M., Lipner, J., Pasteris, J. D., Wopenka, B., & Thomopoulos, S. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0880 · Cited by 158
Micromotion-induced strain fields influence early stages of repair at bone–implant interfaces
Wazen, R. M., Currey, J. A., Guo, H., Brunski, J., Helms, J. A., & Nanci, A. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.01.014 · Cited by 153
Shah, F. A., Omar, O., Suska, F., Snis, A., Matic, A., Emanuelsson, L., Norlindh, B., Lausmaa, J., Thomsen, P., & Palmquist, A. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.03.033 · Cited by 150
Self-citationListgarten, M. A., Buser, D., Steinemann, S. G., Donath, K., Lang, N. P., & Weber, H. P. (1992) · Journal of Dental Research · doi:10.1177/00220345920710020401 · Cited by 146
Palmquist, A., Snis, A., Emanuelsson, L., Browne, M., & Thomsen, P. (2011) · Journal of Biomaterials Applications · doi:10.1177/0731684411431857 · Cited by 144
Self-citationEarly tissue response to titanium implants inserted in rabbit cortical bone
Sennerby, L., Thomsen, P., & Ericson, L. E. (1993) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00120129 · Cited by 135
Self-citationBohner, M., Baroud, G., Bernstein, A., Döbelin, N., Galea, L., Hesse, B., Heuberger, R., Meille, S., Michel, P., von Rechenberg, B., et al. (2017) · Materials Today · doi:10.1016/j.mattod.2017.02.002 · Cited by 132
Futami, T., Fujii, N., Ohnishi, H., Taguchi, N., Kusakari, H., Ohshima, H., & Maeda, T. (2000) · Journal of Periodontology · doi:10.1902/jop.2000.71.2.287 · Cited by 131
Haïat, G., Wang, H., & Brunski, J. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104854 · Cited by 131
Minerals Form a Continuum Phase in Mature Cancellous Bone
Chen, P., Toroian, D., Price, P. A., & McKittrick, J. M. (2011) · Calcified Tissue International · doi:10.1007/s00223-011-9462-8 · Cited by 128
Biological fixation of endosseous implants
Franchi, M., Fini, M., Martini, D., Orsini, E., Leonardi, L., Ruggeri, A., Giavaresi, G., & Ottani, V. (2005) · Micron · doi:10.1016/j.micron.2005.05.010 · Cited by 127
Early detachment of titanium particles from various different surfaces of endosseous dental implants
Franchi, M., Bacchelli, B., Martini, D., Pasquale, V. D., Orsini, E., Ottani, V., Fini, M., Giavaresi, G., Giardino, R., & Ruggeri, A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.017 · Cited by 125
Davies, J. E., Ajami, E., Moineddin, R., & Mendes, V. C. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.024 · Cited by 124
Multiscale Analyses of the Bone-implant Interface
Cha, J., Pereira, M. D., Smith, A. A., Houschyar, K. S., Yin, X., Mouraret, S., Brunski, J., & Helms, J. A. (2015) · Journal of Dental Research · doi:10.1177/0022034514566029 · Cited by 122
Giant cells around bone biomaterials: Osteoclasts or multi-nucleated giant cells?
Miron, R. J., Zohdi, H., Fujioka‐Kobayashi, M., & Bosshardt, D. D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.029 · Cited by 119
The histopathology of different foreign-body reactions in oral soft tissue and bone tissue
Donath, K., Laaß, M., & Günzl, H.-J. (1992) · Archiv für Pathologische Anatomie und Physiologie und für Klinische Medicin · doi:10.1007/bf02358804 · Cited by 115
Surface modifications of a titanium implant by a picosecond Nd:YAG laser operating at 1064 and 532nm
Trtica, M. S., Gaković, B. M., Batani, D., Desai, T., Panjan, P., & Radak, B. B. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.05.024 · Cited by 115
Effect of carbonate substitution on the ultrastructural characteristics of hydroxyapatite implants
Porter, A. E., Patel, N., Brooks, R. A., Best, S. M., Rushton, N., & Bonfield, W. (2005) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-005-4424-1 · Cited by 114
Grünewald, T. A., Rennhofer, H., Hesse, B., Burghammer, M. C., Stanzl‐Tschegg, S. E., Cotte, M., Löffler, J. F., Weinberg, A., & Lichtenegger, H. C. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.10.054 · Cited by 107
Schwarcz, H. P., McNally, E. A., & Botton, G. A. (2014) · Journal of Structural Biology · doi:10.1016/j.jsb.2014.10.005 · Cited by 106
Wermelin, K., Suska, F., Tengvall, P., Thomsen, P., & Aspenberg, P. (2007) · Bone · doi:10.1016/j.bone.2007.10.013 · Cited by 101
Self-citationShah, F. A., Johansson, M. L., Omar, O., Hanna, S., Palmquist, A., & Thomsen, P. (2016) · PLoS ONE · doi:10.1371/journal.pone.0157504 · Cited by 101
Self-citationClinical Evaluation of Laser Microtexturing for Soft Tissue and Bone Attachment to Dental Implants
Pecora, G. E., Ceccarelli, R., Bonelli, M., Alexander, H., & Ricci, J. L. (2009) · Implant Dentistry · doi:10.1097/id.0b013e31818c5a6d · Cited by 100
Luklinska, Z. B., & Bonfield, W. (1997) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1018589018205 · Cited by 97
Grandfield, K., Vuong, V., & Schwarcz, H. P. (2018) · Calcified Tissue International · doi:10.1007/s00223-018-0454-9 · Cited by 91
Deposition of calcium ions on rutile (110): a first-principles investigation
Svetina, M., Ciacchi, L. C., Sbaizero, O., Meriani, S., & Vita, A. D. (2001) · Acta Materialia · doi:10.1016/s1359-6454(01)00136-7 · Cited by 90
Noyama, Y., Nakano, T., Ishimoto, T., Sakai, T., & Yoshikawa, H. (2012) · Bone · doi:10.1016/j.bone.2012.11.005 · Cited by 88
A Review of the Impact of Implant Biomaterials on Osteocytes
Shah, F. A., Thomsen, P., & Palmquist, A. (2018) · Journal of Dental Research · doi:10.1177/0022034518778033 · Cited by 86
Self-citationPalmquist, A., Lindberg, F., Emanuelsson, L., Brånemark, R., Engqvist, H., & Thomsen, P. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32439 · Cited by 82
Self-citationGiannuzzi, L. A., Phifer, D., Giannuzzi, N. J., & Capuano, M. J. (2007) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2006.10.025 · Cited by 79
Omar, O., Lennerås, M., Suska, F., Emanuelsson, L., Hall, J., Palmquist, A., & Thomsen, P. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.011 · Cited by 79
Self-citationThe Effects of Laser Microtextured Collars Upon Crestal Bone Levels of Dental Implants
Weiner, S., Simon, J., Ehrenberg, D. S., Zweig, B. E., & Ricci, J. L. (2008) · Implant Dentistry · doi:10.1097/id.0b013e3181779016 · Cited by 77
In vivo gene expression in response to anodically oxidized versus machined titanium implants
Omar, O., Svensson, S., Zoric, N., Lennerås, M., Suska, F., Wigren, S., Hall, J., Nannmark, U., & Thomsen, P. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32475 · Cited by 76
Self-citationRole of the Osteoclast at the Bone-Implant Interface
Minkin, C., & Marinho, V. C. (1999) · Advances in Dental Research · doi:10.1177/08959374990130011401 · Cited by 76
Dépalle, B., Zhao Qin, A., Shefelbine, S. J., & Buehler, M. J. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2705 · Cited by 75
Bone tissue aging affects mineralization of cement lines
Milovanovic, P. D., Scheidt, A. V., Mletzko, K., Sarau, G., Püschel, K., Djuric, M. P., Amling, M., Christiansen, S. H., & Busse, B. (2018) · Bone · doi:10.1016/j.bone.2018.02.004 · Cited by 73
Harmankaya, N., Karlsson, J. E., Palmquist, A., Halvarsson, M., Igawa, K., Andersson, M., & Tengvall, P. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.02.040 · Cited by 71
Self-citationTopographic scale-range synergy at the functional bone/implant interface
Davies, J. E., Mendes, V. C., Ko, J. C.-H., & Ajami, E. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.09.072 · Cited by 71
The bone-implant interface – nanoscale analysis of clinically retrieved dental implants
Shah, F. A., Nilson, B., Brånemark, R., Thomsen, P., & Palmquist, A. (2014) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2014.05.015 · Cited by 68
Self-citationSurface-dimpled commercially pure titanium implant and bone ingrowth
Li, J., Liao, H., Fartash, B., Hermansson, L., & Johnsson, T. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00185-8 · Cited by 65
Bisphosphonate coating on titanium screws increases mechanical fixation in rat tibia after two weeks
Wermelin, K., Aspenberg, P., Linderbäck, P., & Tengvall, P. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31583 · Cited by 65
Scanning transmission electron microscopic tomography of cortical bone using Z-contrast imaging
McNally, E. A., Nan, F., Botton, G. A., & Schwarcz, H. P. (2013) · Micron · doi:10.1016/j.micron.2013.03.002 · Cited by 64
Engqvist, H., Botton, G. A., Couillard, M., Mohammadi, S., Malmström, J., Emanuelsson, L., Hermansson, L., Phaneuf, M. W., & Thomsen, P. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30696 · Cited by 63
Self-citationPalmquist, A., Emanuelsson, L., Brånemark, R., & Thomsen, P. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31814 · Cited by 61
Self-citationKuroshima, S., Nakano, T., Ishimoto, T., Sasaki, M., Inoue, M., Yasutake, M., & Sawase, T. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.021 · Cited by 61
Applicability of ToF-SIMS for monitoring compositional changes in bone in a long-term animal model
Henß, A., Rohnke, M., Khassawna, T. E., Govindarajan, P., Schlewitz, G., Heiß, C., & Janek, J. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0332 · Cited by 59
Shah, F. A., Wang, X., Thomsen, P., Grandfield, K., & Palmquist, A. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/ab500127y · Cited by 58
Self-citationThe bone-implant interface of dental implants in humans on the atomic scale
Sundell, G., Dahlin, C., Andersson, M., & Thuvander, M. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.044 · Cited by 57
Microstimulation at the bone–implant interface upregulates osteoclast activation pathways
Stadelmann, V. A., Terrier, A., & Pioletti, D. P. (2007) · Bone · doi:10.1016/j.bone.2007.09.055 · Cited by 56
Where bone meets implant: the characterization of nano-osseointegration
Grandfield, K., Gustafsson, S., & Palmquist, A. (2013) · Nanoscale · doi:10.1039/c3nr00826f · Cited by 54
Self-citationXu, R., Shi, G., Xu, L., Gu, Q., Fu, Y., Zhang, P., Cheng, J., & Jiang, H. (2018) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2652 · Cited by 54
Atomically Resolved Tissue Integration
Karlsson, J. E., Sundell, G., Thuvander, M., & Andersson, M. (2014) · Nano Letters · doi:10.1021/nl501564f · Cited by 48
Osseointegration Enhancement by Zr doping of Co-Cr-Mo Implants Fabricated by Electron Beam Melting
Stenlund, P., Kurosu, S., Koizumi, Y., Suska, F., Matsumoto, H., Chiba, A., & Palmquist, A. (2015) · Additive manufacturing · doi:10.1016/j.addma.2015.02.002 · Cited by 48
Self-citationA multiscale analytical approach to evaluate osseointegration
Palmquist, A. (2018) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-018-6068-y · Cited by 48
Self-citationBone healing and the effect of implant surface topography on osteoconduction in hyperglycemia
Ajami, E., Mahno, E., Mendes, V. C., Bell, S., Moineddin, R., & Davies, J. E. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.09.020 · Cited by 47
Effects of mechanical repetitive load on bone quality around implants in rat maxillae
Uto, Y., Kuroshima, S., Nakano, T., Ishimoto, T., Inaba, N., Uchida, Y., & Sawase, T. (2017) · PLoS ONE · doi:10.1371/journal.pone.0189893 · Cited by 45
Forearm bone-anchored amputation prosthesis: A case study on the osseointegration
Palmquist, A., Jarmar, T., Emanuelsson, L., Brånemark, R., Engqvist, H., & Thomsen, P. (2008) · Acta Orthopaedica · doi:10.1080/17453670710014806 · Cited by 43
Self-citationLennerås, M., Palmquist, A., Norlindh, B., Emanuelsson, L., Thomsen, P., & Omar, O. (2014) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12276 · Cited by 43
Self-citationBone, implants, and their interfaces
Grandfield, K. (2015) · Physics Today · doi:10.1063/pt.3.2748 · Cited by 38
Shah, F. A., Zanghellini, E., Matic, A., Thomsen, P., & Palmquist, A. (2015) · Calcified Tissue International · doi:10.1007/s00223-015-0072-8 · Cited by 34
Self-citationThe Ultrastructural Relationship Between Osteocytes and Dental Implants Following Osseointegration
Du, Z., Ivanovski, S., Hamlet, S. M., Feng, J. Q., & Xiao, Y. (2014) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12257 · Cited by 33
Palmquist, A., Emanuelsson, L., & Sjövall, P. (2012) · Applied Surface Science · doi:10.1016/j.apsusc.2012.03.065 · Cited by 33
Self-citationShah, F. A., Stenlund, P., Martinelli, A., Thomsen, P., & Palmquist, A. (2016) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-016-5779-1 · Cited by 33
Self-citationUltrastructural alterations of osteocyte morphology via loaded implants in rabbit tibiae
Sasaki, M., Kuroshima, S., Aoki, Y., Inaba, N., & Sawase, T. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.10.025 · Cited by 32
Pazzaglia, U. E., Congiu, T., Marchese, M., & Dell’Orbo, C. (2010) · Cell and Tissue Research · doi:10.1007/s00441-010-0970-z · Cited by 31
Elgali, I., Igawa, K., Palmquist, A., Lennerås, M., Xia, W., Choi, S.-J., Chung, U., Omar, O., & Thomsen, P. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.12.084 · Cited by 31
Self-citationWang, X., Shah, F. A., Palmquist, A., & Grandfield, K. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00519 · Cited by 30
Self-citationGrandfield, K., Palmquist, A., Ericson, F., Malmström, J., Emanuelsson, L., Slotte, C., Adolfsson, E., Botton, G. A., Thomsen, P., & Engqvist, H. (2010) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2009.00270.x · Cited by 27
Self-citationBiomineralization at Titanium Revealed by Correlative 4D Tomographic and Spectroscopic Methods
Wang, X., Langelier, B., Shah, F. A., Korinek, A., Bugnet, M., Hitchcock, A. P., Palmquist, A., & Grandfield, K. (2018) · Advanced Materials Interfaces · doi:10.1002/admi.201800262 · Cited by 27
Self-citationAdvances in Multiscale Characterization Techniques of Bone and Biomaterials Interfaces
Binkley, D. M., & Grandfield, K. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00420 · Cited by 26
Shah, F. A., Jergéus, E., Chiba, A., & Palmquist, A. (2018) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36366 · Cited by 21
Self-citationShah, F. A., & Palmquist, A. (2017) · Calcified Tissue International · doi:10.1007/s00223-017-0283-2 · Cited by 20
Self-citationSayardoust, S., Omar, O., Norderyd, O. M., & Thomsen, P. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13351 · Cited by 15
Self-citationFIB, SEM, and TEM of Bone/Dental Implant Interfaces
Giannuzzi, L. A., Giannuzzi, N. J., & Capuano, M. J. (2005) · Microscopy and Microanalysis · doi:10.1017/s1431927605508225 · Cited by 9
On a novel technique for preparation and analysis of the implant surface and its interface to bone
Palmquist, A. (2008) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 5
Self-citation
Cited by
Synthetic bone: Design by additive manufacturing
Barba, D., Alabort, E., & Reed, R. C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.049 · Cited by 316
Titanium–Tissue Interface Reaction and Its Control With Surface Treatment
Hanawa, T. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00170 · Cited by 284
Biomechanical behaviours of the bone–implant interface: a review
Gao, X., Fraulob, M., & Haïat, G. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0259 · Cited by 263
Design, printing, and engineering of regenerative biomaterials for personalized bone healthcare
Jia, Z., Xu, X., Zhu, D., & Zheng, Y. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101072 · Cited by 176
Shah, F. A., Ruscsák, K., & Palmquist, A. (2019) · Bone Research · doi:10.1038/s41413-019-0053-z · Cited by 115
Self-citation
Metadata
- Authors
- Shah, F. A., Thomsen, P., & Palmquist, A.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 84
- Pages
- 1-15
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2901341767
- Cited by
- 381
- References
- 135
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.