The DOI matches its Crossref record; 141 of the 143 references it cites were found in a registry or an index.
Top Down proteomics: Facts and perspectives
Open accessAbstract
The rise of the "Top Down" method in the field of mass spectrometry-based proteomics has ushered in a new age of promise and challenge for the characterization and identification of proteins. Injecting intact proteins into the mass spectrometer allows for better characterization of post-translational modifications and avoids several of the serious "inference" problems associated with peptide-based proteomics. However, successful implementation of a Top Down approach to endogenous or other biologically relevant samples often requires the use of one or more forms of separation prior to mass spectrometric analysis, which have only begun to mature for whole protein MS. Recent advances in instrumentation have been used in conjunction with new ion fragmentation using photons and electrons that allow for better (and often complete) protein characterization on cases simply not tractable even just a few years ago. Finally, the use of native electrospray mass spectrometry has shown great promise for the identification and characterization of whole protein complexes in the 100 kDa to 1 MDa regime, with prospects for complete compositional analysis for endogenous protein assemblies a viable goal over the coming few years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This approach is well-known for its high-throughput performance; however, critical information about PTMs and subunit protein assemblies (via non-covalent interactions) is generally lost after proteolysis14,31.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961 · cited 1×
“The most common electrophoretic method is SDS-PAGE, in which SDS-coated protein molecules migrate through a polyacrylamide gel matrix in an electric field achieving separation based largely on molecular weight [40].”
MethodSchägger, H., & von Jagow, G. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90587-2 · Cited by 11,420 · cited 1×
“Using a Tris-tricine [48] variant of the original separation, the authors were able to identify 35 unique proteins from a single GELFrEE separation of HeLa cells.”
MethodMass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M. S., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,996 · cited 8×
“Strong anion exchange (SAX) coupled to RPLC-MS for intact protein separations has also been reported for the study of E. coli [34].”
MethodInfluentialElectrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955 · cited 4×
“Proteomic experiments can be used for the annotation and correction of genome sequences, quantitation of protein abundance, detection of posttranslational modifications (PTMs), and identification of protein-protein interactions [2].”
BackgroundMethodInfluentialLaser desorption ionization of proteins with molecular masses exceeding 10,000 daltons.
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,145 · cited 7×
“Wall DB, Kachman MT, Gong SY, Hinderer R, Parus S, Misek DE, Hanash SM, Lubman DM. Isoelectric focusing nonporous RP HPLC: A two-dimensional liquid-phase separation method for mapping of cellular proteins with identification using MALDI-TOF mass spectrometry.”
MethodInfluentialWessel, D., & Flügge, U. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90782-6 · Cited by 3,997 · cited 1×
“The GELFrEE device was first applied to a Top Down study in 2009, utilizing SDS which was then removed using methanol/chloroform/water precipitation [47] prior to online nanoLC-MS [23].”
MethodProtein and polymer analyses up to m/z 100 000 by laser ionization time-of-flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,005 · cited 7×
“Wall DB, Kachman MT, Gong SY, Hinderer R, Parus S, Misek DE, Hanash SM, Lubman DM. Isoelectric focusing nonporous RP HPLC: A two-dimensional liquid-phase separation method for mapping of cellular proteins with identification using MALDI-TOF mass spectrometry.”
MethodInfluentialPeptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1 · Cited by 2,045
Zone electrophoresis in open-tubular glass capillaries
Jorgenson, J. W., & Lukacs, K. D. A. (1981) · Analytical Chemistry · doi:10.1021/ac00231a037 · Cited by 1,942 · cited 1×
“The small capillaries (<100 μm inner diameter) used within CE allow for high separation voltages (10–30 kV) without Joule heating, thereby reducing separation time and increasing peak capacity by limiting longitudinal diffusion [56,57,58].”
MethodElectron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881 · cited 10×
“The LTQ-Orbitrap was also used to distinguish several glycoforms from intact recombinant antibodies (~150 kDa) and fragment the reduced light and heavy chains using CID [106].”
MethodResultInfluentialSelf-citationElectrospray ion source: another variation on the free-jet theme
Yamashita, M., & Fenn, J. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 1,800 · cited 9×
“ESI generates multiply charged ions and is the preferred method for the analysis of both peptides and intact proteins, especially on a proteomics wide-scale.”
MethodInfluentialFemtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry
Wilm, M., Shevchenko, A., Houthaeve, T., Breit, S., Schweigerer, L., Fotsis, T., & Mann, M. (1996) · Nature · doi:10.1038/379466a0 · Cited by 1,674 · cited 8×
“Strong anion exchange (SAX) coupled to RPLC-MS for intact protein separations has also been reported for the study of E. coli [34].”
MethodInfluentialProteoform: a single term describing protein complexity
The Consortium for Top Down Proteomics, Smith, L. M., & Kelleher, N. L. (2013) · Nature Methods · doi:10.1038/nmeth.2369 · Cited by 1,528 · cited 1×
“This approach routinely allows for 100% sequence coverage and full characterization of proteoforms, the specific molecular form of the protein resulting from combinations of genetic variation, alternative splicing, and post-translational modifications [5].”
Self-citationElectrospray interface for liquid chromatographs and mass spectrometers.
Whitehouse, C., Dreyer, R., Yamashita, M., & Fenn, J. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,368 · cited 1×
“In many cases, liquid chromatography can often be coupled to electrospray ionization (ESI), proving an effective method for on-line analysis [14].”
BackgroundEvaluation of two-dimensional gel electrophoresis-based proteome analysis technology
Gygi, S. P., Corthals, G. L., Zhang, Y., Rochon, Y. P., & Aebersold, R. H. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.160270797 · Cited by 1,311 · cited 1×
“This approach can be extended to two-dimensional gel electrophoresis (2-DE) in which isoelectric focusing (IEF) is used as the first dimension of separation to separate proteins according to their pI, which can be useful for resolving modified proteins, and then SDS-PAGE is performed as the second dimension [39,43].”
BackgroundFourier transform ion cyclotron resonance spectroscopy
Comisarow, M. B., & Marshall, A. G. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)89137-2 · Cited by 1,038 · cited 1×
“Fourier transform ion cyclotron resonance mass spectrometry relies on the excitation of an ion at its cyclotron frequency within a strong magnetic field [77,78,79].”
BackgroundHigher-energy C-trap dissociation for peptide modification analysis
Olsen, J. V., Maček, B., Lange, O., Makarov, A., Horning, S. R., & Mann, M. (2007) · Nature Methods · doi:10.1038/nmeth1060 · Cited by 1,032
Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 991 · cited 1×
“A new type of Fourier transform mass spectrometer was described in 2000, the Orbitrap mass analyzer [101].”
MethodA Census of Human Soluble Protein Complexes
Havugimana, P. C., Hart, T., Nepusz, T., Yang, H., Turinsky, A. L., Li, Z., Wang, P. I., Boutz, D. R., Fong, V., Phanse, S., et al. (2012) · Cell · doi:10.1016/j.cell.2012.08.011 · Cited by 869
Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer.
Makarov, A., Denisov, E. V., Kholomeev, A., Balschun, W., Lange, O., Strupat, K., & Horning, S. (2006) · Analytical Chemistry · doi:10.1021/ac0518811 · Cited by 771 · cited 1×
“accuracy with AGC, and enabling efficient fragmentation [102].”
MethodNative mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
High-resolution separations based on electrophoresis and electroosmosis
Jorgenson, J. W., & Lukacs, K. D. A. (1981) · doi:10.1016/s0021-9673(00)82057-9 · Cited by 743 · cited 1×
“The small capillaries (<100 μm inner diameter) used within CE allow for high separation voltages (10–30 kV) without Joule heating, thereby reducing separation time and increasing peak capacity by limiting longitudinal diffusion [56,57,58].”
MethodRabilloud, T. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200201)2:1 · Cited by 725
Mapping intact protein isoforms in discovery mode using top-down proteomics
Tran, J. C., Zamdborg, L., Ahlf, D. R., Lee, J. E., Catherman, A. D., Durbin, K. R., Tipton, J. D., Vellaichamy, A., Kellie, J. F., Li, M., et al. (2011) · Nature · doi:10.1038/nature10575 · Cited by 665 · cited 3×
“ProSightPC has also been implemented on a computing cluster for processing large amount of Top Down data.[50] More recently, an online database search and retrieval has been paired with ProSight with a resulting 42 orders of magnitude gain in protein characterization[124].”
BackgroundMethodSelf-citationHjertén, S. (1967) · Chromatographic Reviews · doi:10.1016/0009-5907(67)80003-6 · Cited by 619 · cited 1×
“The small capillaries (<100 μm inner diameter) used within CE allow for high separation voltages (10–30 kV) without Joule heating, thereby reducing separation time and increasing peak capacity by limiting longitudinal diffusion [56,57,58].”
MethodIon activation methods for tandem mass spectrometry
Sleno, L., & Volmer, D. A. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.703 · Cited by 559 · cited 1×
“In ECD bond-cleavage occurs before energy can be redistributed throughout the molecule, often attributed to the process being “non-ergodic” and can be utilized to achieve significantly different fragmentation patterns than collisional methods [86,87].”
BackgroundAutomated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
A dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
Detection of noncovalent receptor-ligand complexes by mass spectrometry
Ganem, B., Li, Y., & Henion, J. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00016a069 · Cited by 464
Mass Spectrometry: Bottom-Up or Top-Down?
Chait, B. T. (2006) · Science · doi:10.1126/science.1133987 · Cited by 464 · cited 1×
“Mass spectrometry-based proteomics has traditionally been carried out in a Bottom Up approach [3,4].”
MethodSenko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. ‐., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 461 · cited 1×
“Significant advances to FT-ICR technology, often focused on improving the analysis of intact proteins, included increases in magnetic field [88,89], addition of a resolving quadrupole for mass selection [90], and an accumulation octupole for ion storage before transmission to the ICR cell [91,92].”
Peer Reviewed: Top-Down Proteomics
Kelleher, N. (2004) · Analytical Chemistry · doi:10.1021/ac0415657 · Cited by 386
Self-citationJournal of The American Society for Mass Spectrometry
(1997) · doi:10.1016/s1044-0305(97)80047-5 · Cited by 381 · cited 1×
“Significant advances to FT-ICR technology, often focused on improving the analysis of intact proteins, included increases in magnetic field [88,89], addition of a resolving quadrupole for mass selection [90], and an accumulation octupole for ion storage before transmission to the ICR cell [91,92].”
Adaptation of the equipment for high-performance electrophoresis to isoelectric focusing
Hjertén, S., & Zhu, M.-D. (1985) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90512-0 · Cited by 373 · cited 1×
“Capillary isoelectric focusing (cIEF), another common CE separation mode, provides a high resolution separation within an open capillary tube which has typically been coated with polyacrylamide to reduce electroosmotic flow and protein adsorption [63,64].”
BackgroundMichalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Syka, J. E. P., Marto, J. A., Bai, D. L., Horning, S. R., Senko, M. W., Schwartz, J. C., Ueberheide, B. M., Garcia, B. A., Busby, S. A., Muratore‐Schroeder, T. L., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 349 · cited 1×
“The construction of a linear quadrupole ion trap/FT-ICR mass spectrometer was first reported in 2004 [95].”
MethodFrequency-sweep fourier transform ion cyclotron resonance spectroscopy
Comisarow, M. B., & Marshall, A. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)80397-0 · Cited by 324 · cited 1×
“Fourier transform ion cyclotron resonance mass spectrometry relies on the excitation of an ion at its cyclotron frequency within a strong magnetic field [77,78,79].”
BackgroundYates, J. R., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac401484r · Cited by 324 · cited 3×
“The detection and identification of intact proteins, especially on a proteome-wide level, depends on high performance mass spectrometers [3].”
BackgroundMethodSelf-citationHigh-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309 · cited 1×
“8 Tesla (T) instrument, allowing for accurate mass determination [81,82].”
BackgroundComprehensive on-line LC/LC/MS of proteins.
Opiteck, G., Lewis, K. C., Jorgenson, J. W., & Anderegg, R. (1997) · Analytical Chemistry · doi:10.1021/ac961155l · Cited by 277 · cited 1×
“reported the use of cation exchange coupled to on-line RPLC for the two dimensional separation of the Escherichia coli proteome [33].”
MethodOrigin of asymmetric charge partitioning in the dissociation of gas-phase protein homodimers.
Jurchen, J., & Williams, E. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0211508 · Cited by 262
Senko, M. W., Canterbury, J. D., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14 · Cited by 257
Zamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Self-citationPervasive combinatorial modification of histone H3 in human cells
Garcia, B. A., Pesavento, J. J., Mizzen, C. A., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1052 · Cited by 243 · cited 1×
“[28,29] HILIC has also been extensively applied for the separation of modified histone forms prior to Top Down mass spectrometry [30,31,32].”
MethodSelf-citationOn the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243 · cited 2×
“Sensitivity is also vital, as high molecular weight species such as proteins will have broad isotopic distributions, distributing the signal from a single protein across many peaks [71].”
BackgroundSelf-citationKonermann, L., & Douglas, D. J. (1997) · Biochemistry · doi:10.1021/bi971266u · Cited by 238
Zubarev, R., Haselmann, K., Budnik, B., Kjeldsen, F., & Jensen, F. (2002) · European Journal of Mass Spectrometry · doi:10.1255/ejms.517 · Cited by 215 · cited 2×
“CID and other collisional methods are based upon vibrational excitation, where vibrational energy can be distributed throughout the molecule, often causing the fragmentation of the weakest bonds [86].”
BackgroundWall, D. B., Kachman, M. T., Gong, S., Hinderer, R., Parus, S., Misek, D. E., Hanash, S., & Lubman, D. M. (2000) · Analytical Chemistry · doi:10.1021/ac991332t · Cited by 211 · cited 3×
“Isoelectric focusing (IEF) for Top Down proteomics is generally considered more difficult as proteins tend to precipitate at their isoelectric point, significantly reducing their recovery from the gel media [18].”
BackgroundMethodInformatics and multiplexing of intact protein identification in bacteria and the archaea
Meng, F., Cargile, B. J., Miller, L. M., Forbes, A. J., Johnson, J. R., & Kelleher, N. L. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-952 · Cited by 210
Self-citationTran, J. C., & Doucette, A. A. (2008) · Analytical Chemistry · doi:10.1021/ac702197w · Cited by 206
Maček, B., Waanders, L. F., Olsen, J. V., & Mann, M. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500042-mcp200 · Cited by 201
MALDI imaging mass spectrometry of human tissue: method challenges and clinical perspectives
Seeley, E. H., & Caprioli, R. M. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.12.002 · Cited by 197
Zhang, J., Guy, M. J., Norman, H. S., Chen, Y.-C., Xu, Q., Dong, X., Guner, H., Wang, S., Kohmoto, T., Young, K. H., et al. (2011) · Journal of Proteome Research · doi:10.1021/pr200258m · Cited by 194 · cited 1×
“The potential for achieving full protein characterization has made the Top Down mass spectrometry approach extremely useful for analysis of single proteins or simple mixtures of significant biological interest [6,7,8,9,10,11].”
BackgroundFourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences of the United States of America · doi:10.1073/pnas.86.23.9075 · Cited by 193 · cited 1×
“ESI-FT-ICR was first used for the analysis of intact proteins in 1989, with the detection of multiple charge states on a single protein, allowing for intact mass determination [80].”
MethodLeDuc, R. D., Taylor, G. K., Kim, Y.-B., Januszyk, T. E., Bynum, L., Solà, J., Garavelli, J., & Kelleher, N. (2004) · Nucleic Acids Res. · doi:10.1093/nar/gkh447 · Cited by 192
Self-citationJensen, P. K., Paša-Tolić, L., Anderson, G. A., Horner, J. A., Lipton, M., Bruce, J. E., & Smith, R. D. (1999) · Analytical Chemistry · doi:10.1021/ac990196p · Cited by 190 · cited 1×
“Improvements to the cIEF separation and data acquisition, as well as the use of isotopically-depleted growth media for improved sensitivity, allowed for the detection of 1,000 polypeptides/proteins from ~300 ng of protein [66,67].”
Method博一, 長., Bullock, C. R., LeDuc, R. D., Mizzen, C. A., & Kelleher, N. L. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m709796200 · Cited by 186 · cited 1×
“[28,29] HILIC has also been extensively applied for the separation of modified histone forms prior to Top Down mass spectrometry [30,31,32].”
MethodSelf-citationLee, S., Berger, S. J., Martinović, S., Paša‐Tolić, L., Anderson, G., Shen, Y., Zhao, R., & Smith, R. D. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082119899 · Cited by 185 · cited 1×
“For intact proteins, RPLC is typically employed as a second dimension of separation, but it has often been successfully applied as the sole separation strategy [13,15,22,25].”
MethodCapillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185 · cited 1×
“CZE has been the most common CE mode applied to the mass spectrometry of intact proteins [59].”
MethodProcessing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183 · cited 3×
“Additionally, many reports have been published using derivatized nonporous silica (NPS) particles, which offer increased speed and protein recovery, but suffer from limited loading capacity and high back pressure [15,16,17,18,19,20].”
BackgroundMethodSelf-citationHigh-performance mass spectrometry: Fourier transform ion cyclotron resonance at 14.5 Tesla.
Schaub, T. M., Hendrickson, C., Horning, S., Quinn, J. P., Senko, M., & Marshall, A. (2008) · Analytical Chemistry · doi:10.1021/ac800386h · Cited by 178 · cited 1×
“5 T version of the LTQ-FT-ICR instrument has also been reported, featuring approximately 4-fold higher mass accuracy and twice the resolving power of the 7T instrument [99].”
MethodMcAlister, G. C., Phanstiel, D., Good, D. M., Berggren, W. T., & Coon, J. J. (2007) · Analytical Chemistry · doi:10.1021/ac070020k · Cited by 176
Mass spectrometry of membrane transporters reveals subunit stoichiometry and interactions
Barrera, N. P., Isaacson, S. C., Zhou, M., Bavro, V. N., Welch, A., Schaedler, T. A., Seeger, M., Miguel, R., Korkhov, V. M., van Veen, H. V., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1347 · Cited by 175 · cited 1×
“The potential for achieving full protein characterization has made the Top Down mass spectrometry approach extremely useful for analysis of single proteins or simple mixtures of significant biological interest [6,7,8,9,10,11].”
BackgroundBelov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175
Self-citationKilár, F., & Hjertén, S. (1989) · Electrophoresis · doi:10.1002/elps.1150100107 · Cited by 164 · cited 1×
“Capillary isoelectric focusing (cIEF), another common CE separation mode, provides a high resolution separation within an open capillary tube which has typically been coated with polyacrylamide to reduce electroosmotic flow and protein adsorption [63,64].”
BackgroundZhang, H., Cui, W., Wen, J., Blankenship, R. E., & Gross, M. L. (2011) · Analytical Chemistry · doi:10.1021/ac200695d · Cited by 163
Dual-Pressure Linear Ion Trap Mass Spectrometer Improving the Analysis of Complex Protein Mixtures
Second, T. P., Blethrow, J. D., Schwartz, J. C., Merrihew, G. E., MacCoss, M. J., Swaney, D. L., Russell, J. D., Coon, J. J., & Zabrouskov, V. (2009) · Analytical Chemistry · doi:10.1021/ac901278y · Cited by 160
Kaddis, C. S., Lomeli, S. H., Yin, S., Berhane, B., Apostol, M., Kickhoefer, V., Rome, L. H., & Loo, J. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.02.015 · Cited by 159
Analysis of Intact Monoclonal Antibody IgG1 by Electron Transfer Dissociation Orbitrap FTMS
Fornelli, L., Damoc, E., Thomas, P. M., Kelleher, N. L., Aizikov, K., Denisov, E. V., Makarov, A., & Tsybin, Y. O. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.019620 · Cited by 159
Self-citationCatherman, A. D., Durbin, K. R., Ahlf, D. R., Early, B. P., Fellers, R. T., Tran, J. C., Thomas, P. M., & Kelleher, N. L. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.030114 · Cited by 157
Self-citationBondarenko, P. V., Second, T. P., Zabrouskov, V., Makarov, A., & Zhang, Z. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.020 · Cited by 151
Collisions or Electrons? Protein Sequence Analysis in the 21st Century
Coon, J. J. (2009) · Analytical Chemistry · doi:10.1021/ac802330b · Cited by 149
McAlister, G. C., Berggren, W. T., Griep‐Raming, J., Horning, S. R., Makarov, A., Phanstiel, D., Stafford, G. C., Swaney, D. L., Syka, J. E. P., Zabrouskov, V., et al. (2008) · Journal of Proteome Research · doi:10.1021/pr800264t · Cited by 145
Wilcox, B., Hendrickson, C., & Marshall, A. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00622-0 · Cited by 139 · cited 1×
“Significant advances to FT-ICR technology, often focused on improving the analysis of intact proteins, included increases in magnetic field [88,89], addition of a resolving quadrupole for mass selection [90], and an accumulation octupole for ion storage before transmission to the ICR cell [91,92].”
Hogan, C. J., Ruotolo, B., Robinson, C., & de la Mora, J. F. (2011) · Journal of Physical Chemistry B · doi:10.1021/jp109172k · Cited by 127
Cation-exchange chromatography of peptides on poly(2-sulfoethyl aspartamide)-silica.
Alpert, A. J., & Andrews, P. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)94785-x · Cited by 127 · cited 1×
“In contrast with RPLC, HILIC utilizes a polar stationary phase and gradients of increasing water content, resulting in the elution of more hydrophobic species first [26,27].”
BackgroundParks, B. A., Jiang, L., Thomas, P. M., Wenger, C. D., Roth, M. J., Boyne, M. T., Burke, P. V., Kwast, K. E., & Kelleher, N. L. (2007) · Analytical Chemistry · doi:10.1021/ac070553t · Cited by 123 · cited 2×
“proteome [36] and a variety of membrane proteins [96,97].”
BackgroundMethodSelf-citationMultiplexed Size Separation of Intact Proteins in Solution Phase for Mass Spectrometry
Tran, J. C., & Doucette, A. A. (2009) · Analytical Chemistry · doi:10.1021/ac900729r · Cited by 122 · cited 1×
“It was shown that the device could be used as a first dimension of separation prior to a multiplexed version of GELFrEE, analogous to a twodimensional gel separation [55].”
MethodWeb and database software for identification of intact proteins using "top down" mass spectrometry.
Taylor, G. K., Kim, Y.-B., Forbes, A. J., Meng, F.-Y., McCarthy, R. T., & Kelleher, N. (2003) · Analytical Chemistry · doi:10.1021/ac0341721 · Cited by 119
Self-citationBalaguer, E., & Neusüß, C. (2006) · Analytical Chemistry · doi:10.1021/ac060376g · Cited by 117 · cited 1×
“Notable examples include the detection of the α and β subunits of hemoglobin from a single erythrocyte [60] and the detection of various protein glycoforms of erythropoietin, fetuin, and α1-acid glycoprotein [61].”
BackgroundGene-Specific Characterization of Human Histone H2B by Electron Capture Dissociation
Siuti, N., Roth, M. J., Mizzen, C. A., Kelleher, N. L., & Pesavento, J. J. (2006) · Journal of Proteome Research · doi:10.1021/pr050268v · Cited by 112 · cited 1×
“The potential for achieving full protein characterization has made the Top Down mass spectrometry approach extremely useful for analysis of single proteins or simple mixtures of significant biological interest [6,7,8,9,10,11].”
BackgroundSelf-citationA robust two-dimensional separation for top-down tandem mass spectrometry of the low-mass proteome
Lee, J. E., Kellie, J. F., Tran, J. C., Tipton, J. D., Catherman, A. D., Thomas, H. M., Ahlf, D. R., Durbin, K. R., Vellaichamy, A., Ntai, I., et al. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.08.001 · Cited by 108 · cited 3×
“Polymeric reversed-phase materials, offering increased mechanical strength, uniform hydrophobicity, and high recovery, have also been utilized for the separation of intact proteins [13,22,23,24].”
BackgroundMethodSelf-citationHigh-resolution tandem mass spectrometry of large biomolecules.
Loo, J., Quinn, J. P., Ryu, S. I., Henry, K. D., Senko, M., & McLafferty, F. (1992) · Proceedings of the National Academy of Sciences of the United States of America · doi:10.1073/pnas.89.1.286 · Cited by 105 · cited 1×
“The same instrument was also utilized to perform collision-induced dissociation (CID) and nozzle-skimmer dissociation (NSD) of ubiquitin, using the high resolving power of the instrument to determine charge state and identity of the fragment ions [83].”
MethodRoth, M. J., Forbes, A. J., Boyne, M. T., Kim, Y. B., Robinson, D. E., & Kelleher, N. L. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500064-mcp200 · Cited by 103 · cited 1×
“has been utilized for a variety of Top Down proteomic studies [16,38,45,94].”
MethodSelf-citationAnalysis of Intact Protein Isoforms by Mass Spectrometry
Tipton, J. D., Tran, J. C., Catherman, A. D., Ahlf, D. R., Durbin, K. R., & Kelleher, N. L. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r111.239442 · Cited by 102 · cited 1×
“Extremely high resolution may be required to distinguish disulfide bridges (Δm = 2 Da), deamidation (Δm = 1 Da), trimethylation versus acetylation (Δm = 39 mDa), and phosphorylation versus sulfation (Δm = 10 mDa) [70].”
BackgroundSelf-citationZhang, D., Sweredoski, M. J., Graham, R. L. J., Hess, S. Y., & Shan, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011585 · Cited by 101
Vellaichamy, A., Tran, J. C., Catherman, A. D., Lee, J. E., Kellie, J. F., Sweet, S. M. M., Zamdborg, L., Thomas, P. M., Ahlf, D. R., Durbin, K. R., et al. (2010) · Analytical Chemistry · doi:10.1021/ac9021083 · Cited by 100 · cited 2×
“Polymeric reversed-phase materials, offering increased mechanical strength, uniform hydrophobicity, and high recovery, have also been utilized for the separation of intact proteins [13,22,23,24].”
BackgroundSelf-citationKellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99 · cited 1×
“The great complexity within most proteomic samples requires that they be fractionated prior to introduction to the mass spectrometer [12].”
BackgroundSelf-citationCapriotti, A. L., Cavaliere, C., Foglia, P., Samperi, R., & Laganà, A. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.05.094 · Cited by 95 · cited 6×
“While a variety of liquid chromatography methods have been developed, reversed-phase liquid chromatography (RPLC), hydrophobic interaction liquid chromatography (HILIC), and ion exchange chromatography (IEX) are three of the most common liquid chromatography approaches applied to intact proteins [13].”
BackgroundMethodInfluentialPatrie, S. M., Charlebois, J. P., Whipple, D., Kelleher, N., Hendrickson, C., Quinn, J. P., Marshall, A., & Mukhopadhyay, B. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.031 · Cited by 93
Self-citationDefinition of the mitochondrial proteome by measurement of molecular masses of membrane proteins
Carroll, J., Fearnley, I., & Walker, J. (2006) · Proceedings of the National Academy of Sciences of the United States of America · doi:10.1073/pnas.0607719103 · Cited by 92 · cited 2×
“Membrane proteins extracted from bovine heart mitochondria have been fractionated using HILIC.”
MethodRyan, C., Souda, P., Bassilian, S., Ujwal, R., Zhang, J., Abramson, J., Ping, P., Durazo, A., Bowie, J., Hasan, S., et al. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900516-mcp200 · Cited by 91 · cited 1×
“proteome [36] and a variety of membrane proteins [96,97].”
BackgroundHenry, K. D., & McLafferty, F. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210250912 · Cited by 91 · cited 1×
“8 Tesla (T) instrument, allowing for accurate mass determination [81,82].”
BackgroundEvaluation of the Compact High-Field Orbitrap for Top-Down Proteomics of Human Cells
Ahlf, D. R., Compton, P. D., Tran, J. C., Early, B. P., Thomas, P. M., & Kelleher, N. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3004216 · Cited by 89 · cited 2×
“proteins from the H1299 human cancer cell line [51], followed by the identification of 1976 unique proteins from an H1299 cell line used to probe the proteome-wide difference in cellular senescence[118].”
BackgroundSelf-citationMazur, M. T., Cardasis, H. L., Spellman, D. S., Liaw, A., Yates, N. A., & Hendrickson, R. C. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910776107 · Cited by 87
Mass spectrometric studies on noncovalent dimers of leucine zipper peptides
Li, Y., Hsieh, Y.-L., Henion, J., Senko, M., McLafferty, F., & Ganem, B. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00071a058 · Cited by 84
Improved fourier-transform ion-cyclotron-resonance mass spectrometry of large biomolecules
Beu, S. C., Senko, M. W., Quinn, J. P., & McLafferty, F. W. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85077-b · Cited by 84
Symmetrical gas-phase dissociation of noncovalent protein complexes via surface collisions.
Jones, C. M., Beardsley, R. L., Galhena, A. S., Dagan, S., Cheng, G., & Wysocki, V. (2006) · Journal of the American Chemical Society · doi:10.1021/ja064586m · Cited by 81
Chong, B. E., Yan, F., Lubman, D., & Miller, F. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.227 · Cited by 81 · cited 2×
“variant of IEX which uses a change in pH rather than ionic strength to achieve elution, has been coupled to off-line RPLC for fractionation of intact proteins from breast cancer [17] and Methanosarcina acetivorans [38].”
BackgroundProteomic profiling of intact proteins using WAX-RPLC 2-D separations and FTICR mass spectrometry.
Sharma, S., Simpson, D., Toliċ, N., Jaitly, N., Mayampurath, A., Smith, R. D., & Paša-Tolić, L. (2007) · Journal of Proteome Research · doi:10.1021/pr060354a · Cited by 77 · cited 1×
“Anion exchange-RPLC has been utilized for the Top Down study of Shewanella oneidensis [35], yeast [36], and human leukocytes [37].”
MethodTop Down Proteomics of Human Membrane Proteins from Enriched Mitochondrial Fractions
Catherman, A. D., Li, M., Tran, J. C., Durbin, K. R., Compton, P. D., Early, B. P., Thomas, P. M., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac3031527 · Cited by 76 · cited 2×
“It should also be noted that the LTQ Velos has also been coupled to a 12 T FT-ICR mass spectrometer for Top Down analysis [52], however the instrument has not been commercialized and no other uses of such an instrument have been reported.”
BackgroundMethodSelf-citationEdwards, R., Griffiths, P., Bunch, J., & Cooper, H. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0477-9 · Cited by 75
Resemann, A., Wunderlich, D., Rothbauer, U., Warscheid, B., Leonhardt, H., Fuchser, J., Kuhlmann, K., & Suckau, D. (2010) · Analytical Chemistry · doi:10.1021/ac1000515 · Cited by 68 · cited 1×
“The potential for achieving full protein characterization has made the Top Down mass spectrometry approach extremely useful for analysis of single proteins or simple mixtures of significant biological interest [6,7,8,9,10,11].”
BackgroundMillea, K. M., Krull, I. S., Cohen, S. A., Gebler, J. C., & Berger, S. J. (2005) · Journal of Proteome Research · doi:10.1021/pr050278w · Cited by 66
“Proteotyping”: Population Proteomics of Human Leukocytes Using Top Down Mass Spectrometry
Roth, M. J., Parks, B. A., Ferguson, J. T., Boyne, M. T., & Kelleher, N. L. (2008) · Analytical Chemistry · doi:10.1021/ac800141g · Cited by 65 · cited 2×
“A 12 T version of the instrument has been utilized for increased throughput studies using the automated on-line/offline RPLC-MS platform for the study of HeLa nuclei [22], human leukocytes [37], and M.”
MethodSelf-citationYang, L.-Y., Lee, C. S., Hofstadler, S., Paša-Tolić, L., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac980224o · Cited by 64
Kellie, J. F., Catherman, A. D., Durbin, K. R., Tran, J. C., Tipton, J. D., Norris, J. L., Witkowski, C. E., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac202384v · Cited by 62 · cited 1×
“In the last few years, several papers have been published using GELFrEE for molecular-weight based fractionation for Top Down proteomics, allowing for increased throughput and number of identifications [24,49,50,51,52].”
BackgroundSelf-citationPatrie, S. M., Ferguson, J. T., Robinson, D. E., Whipple, D., Rother, M., Metcalf, W. W., & Kelleher, N. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500219-mcp200 · Cited by 62 · cited 2×
“variant of IEX which uses a change in pH rather than ionic strength to achieve elution, has been coupled to off-line RPLC for fractionation of intact proteins from breast cancer [17] and Methanosarcina acetivorans [38].”
BackgroundMethodSelf-citationWall, D. B., Berger, S. J., Finch, J. W., Cohen, S. A., Richardson, K., Chapman, R. L., Drabble, D., Brown, J. M., & Gostick, D. (2002) · Electrophoresis · doi:10.1002/1522-2683(200209)23:18 · Cited by 62
Self-citationPesavento, J. J., Garcia, B., Streeky, J. A., Kelleher, N., & Mizzen, C. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600404-mcp200 · Cited by 61 · cited 1×
“[28,29] HILIC has also been extensively applied for the separation of modified histone forms prior to Top Down mass spectrometry [30,31,32].”
MethodSelf-citationIdentification of membrane proteins by tandem mass spectrometry of protein ions
Carroll, J., Altman, M. C., Fearnley, I., & Walker, J. (2007) · Proceedings of the National Academy of Sciences of the United States of America · doi:10.1073/pnas.0706817104 · Cited by 60 · cited 2×
“Membrane proteins extracted from bovine heart mitochondria have been fractionated using HILIC.”
MethodPrecursor ion independent algorithm for top-down shotgun proteomics
Tsai, Y. S., Scherl, A., Shaw, J. L., Mackay, C. L., Shaffer, S. A., Langridge‐Smith, P. R. R., & Goodlett, D. R. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.07.024 · Cited by 59
Wall, D., Kachman, M. T., Gong, S.-Y., Parus, S., Long, M. W., & Lubman, D. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.421 · Cited by 57 · cited 2×
“A preparative-scale Rotofor, capable of separating ~1 g of protein within 55 mL of buffer, and the mini-Rotofor, a smaller version of the device which can hold ~15 mL of solution, have been used for the fractionation of the human erythroleukemia cell line proteome prior to NPS-RPLC-MS [18,19,20].”
BackgroundMethodAnalysis of 953 Human Proteins from a Mitochondrial HEK293 Fraction by Complexome Profiling
Wessels, H. J. C. T., Vogel, R. O., Lightowlers, R. N., Spelbrink, J. N., Rodenburg, R. J., van den Heuvel, L. P., van Gool, A. J., Gloerich, J., Smeitink, J. A. M., & Nijtmans, L. G. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068340 · Cited by 55
Zhou, F., & Johnston, M. (2004) · Analytical Chemistry · doi:10.1021/ac035446n · Cited by 54 · cited 1×
“cIEF has also been coupled to RPLC-MS, which allowed for a second dimension of separation and the removal of ampholytes which can cause significant ionization suppression [68].”
MethodBereszczak, J. Z., Barbu, I., Tan, M., Xia, M., Jiang, X., van Duijn, E., & Heck, A. J. R. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.01.005 · Cited by 53
Théberge, R., Infusini, G., Tong, W., McComb, M. E., & Costello, C. E. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.08.012 · Cited by 44
Moini, M., & Huang, H.-Y. (2004) · Electrophoresis · doi:10.1002/elps.200305906 · Cited by 42
Tipton, J. D., Tran, J. C., Catherman, A. D., Ahlf, D. R., Durbin, K. R., Lee, J. E., Kellie, J. F., Kelleher, N. L., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac202651v · Cited by 42 · cited 1×
“This instrument was also utilized for analysis of GELFrEE fractions, using the improvement in sensitivity and resolution for the detection and identification of higher molecular weight proteins [23,100].”
MethodSelf-citationRoth, M. J., Plymire, D. A., Chang, A. N., Kim, J., Maresh, E. M., Larson, S. E., & Patrie, S. M. (2011) · Analytical Chemistry · doi:10.1021/ac202339x · Cited by 42 · cited 1×
“Use of superficially porous particles, which contain a nonporous silica core and a porous shell, has been reported for protein separations, offering similar efficiency to that of nonporous columns but with reduced back pressure and improved loading capacity [21].”
BackgroundThangaraj, B., Ryan, C., Souda, P., Krause, K., Faull, K. F., Weber, A. P. M., Fromme, P., & Whitelegge, J. P. (2010) · Proteomics · doi:10.1002/pmic.201000190 · Cited by 41 · cited 1×
“proteome [36] and a variety of membrane proteins [96,97].”
BackgroundTop-down proteomics reveals novel protein forms expressed in methanosarcina acetivorans
Ferguson, J. T., Wenger, C. D., Metcalf, W. W., & Kelleher, N. L. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.05.014 · Cited by 41 · cited 1×
“acetivorans [98] as well as the GELFrEE platform for the analysis of S.”
MethodSelf-citationZhou, F., Hanson, T. E., & Johnston, M. (2007) · Analytical Chemistry · doi:10.1021/ac071147c · Cited by 40 · cited 1×
“Using this platform, 1200 polypeptides/proteins from Chlorobium tepidum were detected over an eight hour separation [69].”
MethodDoerr, A. (2008) · Nature Methods · doi:10.1038/nmeth1162 · Cited by 40
Belov, M. E., Nikolaev, E. N., Anderson, G., Auberry, K., Harkewicz, R., & Smith, R. D. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00198-7 · Cited by 40 · cited 1×
“Significant advances to FT-ICR technology, often focused on improving the analysis of intact proteins, included increases in magnetic field [88,89], addition of a resolving quadrupole for mass selection [90], and an accumulation octupole for ion storage before transmission to the ICR cell [91,92].”
Structural characterization of intact antibodies by high‐resolution LTQ Orbitrap mass spectrometry
Zhang, J., Liu, H., & Katta, V. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1700 · Cited by 40
Tran, J. C., & Doucette, A. (2008) · Journal of Proteome Research · doi:10.1021/pr700677u · Cited by 37 · cited 1×
“Another variant of solution isoelectric focusing (sIEF) for protein fractionation was reported in 2008 [54].”
BackgroundErales, J., Gontero, B., Whitelegge, J. P., & Halgand, F. (2008) · Biochemical Journal · doi:10.1042/bj20082004 · Cited by 36 · cited 1×
“The potential for achieving full protein characterization has made the Top Down mass spectrometry approach extremely useful for analysis of single proteins or simple mixtures of significant biological interest [6,7,8,9,10,11].”
BackgroundAlpert, A. J. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)94030-0 · Cited by 35 · cited 1×
“In contrast with RPLC, HILIC utilizes a polar stationary phase and gradients of increasing water content, resulting in the elution of more hydrophobic species first [26,27].”
BackgroundDurbin, K. R., Fellers, R. T., Ntai, I., Kelleher, N. L., & Compton, P. D. (2014) · Analytical Chemistry · doi:10.1021/ac402904h · Cited by 34
Self-citationVersatile Online−Offline Engine for Automated Acquisition of High-Resolution Tandem Mass Spectra
Wenger, C. D., Boyne, M. T., Ferguson, J. T., Robinson, D. E., & Kelleher, N. L. (2008) · Analytical Chemistry · doi:10.1021/ac8010704 · Cited by 33 · cited 4×
“Polymeric reversed-phase materials, offering increased mechanical strength, uniform hydrophobicity, and high recovery, have also been utilized for the separation of intact proteins [13,22,23,24].”
BackgroundMethodInfluentialSelf-citationDavidsson, P., & Nilsson, C. L. (1999) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(99)00197-x · Cited by 32 · cited 1×
“Proteins can be electroeluted from SDS-PAGE gels using an orthogonally applied electric field to the gel; however few studies have been reported, likely due to poor recovery [44].”
BackgroundDu, Y., Meng, F.-Y., Patrie, S. M., Miller, L. M., & Kelleher, N. (2004) · Journal of Proteome Research · doi:10.1021/pr0499489 · Cited by 27 · cited 2×
“An improvement to this original separation used a mini prep-cell, featuring a 7 mm gel column, rather than a 37 mm column, coupled to a 320 μm C4 column allowing for 15 to 300-fold less sample loading as well some on-line analysis [45].”
MethodSelf-citationUse of rotofor preparative isoelectrofocusing cell in protein purification procedure
Ayala, A., Parrado, J., & Machado, A. (1998) · Applied Biochemistry and Biotechnology · doi:10.1007/bf02786017 · Cited by 26 · cited 1×
“The Rotofor device uses an IEF separation but within an open channel, where the pH gradient is formed through the use of carrier ampholytes in solution between an acidic anode and a basic cathode [53].”
MethodWu, S., Brown, R. N., Payne, S., Meng, D., Zhao, R., Tolić, N., Cao, L., Shukla, A. K., Monroe, M. E., Moore, R. J., et al. (2013) · International Journal of Proteomics · doi:10.1155/2013/279590 · Cited by 22
Global histone profiling by LC–FTMS after inhibition and knockdown of deacetylases in human cells
Li, M., Jiang, L., & Kelleher, N. L. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.09.042 · Cited by 21 · cited 1×
“The potential for achieving full protein characterization has made the Top Down mass spectrometry approach extremely useful for analysis of single proteins or simple mixtures of significant biological interest [6,7,8,9,10,11].”
BackgroundSelf-citationHofstadler, S., Severs, J., Smith, R. D., Swanek, F., & Ewing, A. (1996) · doi:10.1002/jhrc.1240191105 · Cited by 17 · cited 1×
“Notable examples include the detection of the α and β subunits of hemoglobin from a single erythrocyte [60] and the detection of various protein glycoforms of erythropoietin, fetuin, and α1-acid glycoprotein [61].”
BackgroundWall, D., Parus, S., & Lubman, D. (2001) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(01)00382-6 · Cited by 12 · cited 2×
“A preparative-scale Rotofor, capable of separating ~1 g of protein within 55 mL of buffer, and the mini-Rotofor, a smaller version of the device which can hold ~15 mL of solution, have been used for the fractionation of the human erythroleukemia cell line proteome prior to NPS-RPLC-MS [18,19,20].”
BackgroundMethodSeparation of polymerase chain reaction amplified bird genes by capillary electrophoresis
Lesaicherre, M.-L., Li, S. F. Y., & Lee, H. K. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:7 · Cited by 1
Research works printed but not linked: 2
- Cox, 2007, Is proteomics the new genomics?, Cell, 130, 395, 10.1016/j.cell.2007.07.032 · DOI
- Perkins, 1999, Probability-based protein identification by searching sequence databases using mass spectrometry data, Electrophoresis, 20, 3551, 10.1002/(SICI)1522-2683(19991201)20:18<3551::AID-ELPS3551>3.0.CO;2-2 · DOI
Cited by
Sorted by citations
Gutiérrez, J. M., Calvete, J. J., Habib, A. G., Harrison, R. A., Williams, D. J., & Warrell, D. A. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.63 · Cited by 1,036
The growing role of precision and personalized medicine for cancer treatment
Krzyszczyk, P., Acevedo, A., Davidoff, E. J., Timmins, L. M., Marrero-Berríos, I., Patel, M., White, C., Lowe, C., Sherba, J. J., Hartmanshenn, C., et al. (2018) · TECHNOLOGY · doi:10.1142/s2339547818300020 · Cited by 759
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Quantitative Proteomic Analysis of Histone Modifications
Huang, H., Lin, S., Garcia, B. A., & Zhao, Y. (2015) · Chemical Reviews · doi:10.1021/cr500491u · Cited by 383
Gillet, L. C., Leitner, A., & Aebersold, R. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041535 · Cited by 323
Metadata
- Authors
- Catherman, A. D., Skinner, O. S., & Kelleher, N. L.
- Affiliations
- Northwestern University (US)
- Corresponding author
- Kelleher, Neil L.
- Venue
- Biochemical and Biophysical Research Communications
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 445
- Issue
- 4
- Pages
- 683-693
- ISSN
- 0006-291X (ISSN-L)
- PMC
- PMC4103433
- OpenAlex
- W2070948666
- Cited by
- 507
- References
- 143
- Citations by year
- 2026: 21 · 2025: 32 · 2024: 31 · 2023: 37 · 2022: 48 · 2021: 49 · 2020: 49 · 2019: 46 · 2018: 41 · 2017: 59 · 2016: 38 · 2015: 42 · 2014: 14
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biochemical and Biophysical Research Communications (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of General Medical Sciences (R01GM067193)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- top-down proteomics, post-translational modification, protein characterization, protein separation, protein complex identification
- MeSH terms
- Amino Acid Sequence, Animals, Chromatography, Liquid, Electrophoresis, Equipment Design, Humans, Molecular Sequence Data, Proteins, Mass Spectrometry, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review