Photoacoustic imaging of living mouse brain vasculature using hollow gold nanospheres
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Photoacoustic tomography (PAT) also referred to as optoacoustic tomography (OAT) is a hybrid imaging modality that employs nonionizing optical radiation and ultrasonic detection. Here, we describe the application of a new class of optical contrast agents based on mesoscopic hollow gold nanospheres (HAuNS) to PAT. HAuNS are ~40 nm in diameter with a hollow interior and consist of a thin gold wall. They display strong resonance absorption tuned to the near infrared (NIR) range, with an absorption peak at 800 nm, whose photoacoustic efficiency is significantly greater than that of blood. Following surface conjugation with thiolated poly(ethylene glycol), the pegylated HAuNS (PEG-HAuNS) had distribution and elimination half-lives of 1.38±0.38 and 71.82±30.46 h, respectively. Compared with PAT images based on the intrinsic optical contrast in nude mice, the PAT images acquired within 2 h after intravenous administration of PEG-HAuNS showed the brain vasculature with greater clarity and detail. The image depicted brain blood vessels as small as ~100 µm in diameter using PEG-HAuNS as contrast agents. Preliminary results showed no acute toxicity to the liver, spleen, or kidneys in mice following a single imaging dose of PEG-HAuNS. Our results indicate that PEG-HAuNS are promising contrast agents for PAT, with high spatial resolution and enhanced sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen
Mie, G. (1908) · Annalen der Physik · doi:10.1002/andp.19083300302 · Cited by 11,537 · cited 1×
“This assumption allowed us to apply standard Mie theory [37] to our calculations, as well as to use the following expressions for absorption (sabs) and scattering (sscat) crosssections [38]:”
MethodA clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
The Scattering of Light and Other Electromagnetic Radiation
(1969) · Elsevier eBooks · doi:10.1016/c2013-0-06195-6 · Cited by 3,816
Some Interesting Properties of Metals Confined in Time and Nanometer Space of Different Shapes
El-Sayed, M. A. (2001) · Accounts of Chemical Research · doi:10.1021/ar960016n · Cited by 2,773
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationGold Nanoparticles Are Taken Up by Human Cells but Do Not Cause Acute Cytotoxicity
Connor, E. E., Mwamuka, J., Gole, A., Murphy, C. J., & Wyatt, M. D. (2005) · Small · doi:10.1002/smll.200400093 · Cited by 2,406
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationGold Nanoparticles in Biology: Beyond Toxicity to Cellular Imaging
Murphy, C. J., Gole, A. M., Stone, J. W., Sisco, P. N., Alkilany, A. M., Goldsmith, E. C., & Baxter, S. C. (2008) · Accounts of Chemical Research · doi:10.1021/ar800035u · Cited by 1,807
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationCarbon nanotubes as photoacoustic molecular imaging agents in living mice
De La Zerda, A., Zavaleta, C., Keren, S., Vaithilingam, S., Bodapati, S., Liu, Z., Levi, J., Smith, B. R., Ma, T.-J., Oralkan, O., et al. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.231 · Cited by 1,271
Vo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
Stealth Me. PEG‐PLA Nanoparticles Avoid Uptake by the Mononuclear Phagocytes System
Bazile, D., Prud'homme, C., Bassoullet, M., Marlard, M., Spenlehauer, G., & Veillard, M. (1995) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600840420 · Cited by 635
(2003) · CRC Press eBooks · doi:10.1201/9780203008997 · Cited by 605
Optical absorption of hemoglobin
Prahl, S. A. (1999) · Medical Entomology and Zoology · Cited by 579
Zhang, G., Yang, Z., Lu, W., Zhang, R., Huang, Q., Tian, M., Li, L., Liang, D., & Li, C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.038 · Cited by 563
Self-citationSynthesis, Characterization, and Tunable Optical Properties of Hollow Gold Nanospheres
Schwartzberg, A. M., Olson, T. Y., Talley, C. E., & Zhang, J. Z. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp062136a · Cited by 508
Wang, X., Xie, X., Ku, G., Wang, L. V., & Stoica, G. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2192804 · Cited by 505
Self-citationLaser optoacoustic imaging system for detection of breast cancer
Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3086616 · Cited by 493
Self-citationThree-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Yang, X., Skrabalak, S. E., Li, Z.-Y., Xia, Y., & Wang, L. V. (2007) · Nano Letters · doi:10.1021/nl072349r · Cited by 407
Self-citationMelancon, M. P., Lu, W., Yang, Z., Zhang, R., Cheng, Z., Elliot, A. M., Stafford, J., Olson, T., Zhang, J. Z., & Li, C. (2008) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-08-0016 · Cited by 392
Self-citationSong, K. H., Kim, C., Cobley, C. M., Xia, Y., & Wang, L. V. (2009) · Nano Letters · doi:10.1021/nl802746w · Cited by 377
Self-citationHigh Sensitivity of In Vivo Detection of Gold Nanorods Using a Laser Optoacoustic Imaging System
Eghtedari, M., Oraevsky, A., Copland, J. A., Kotov, N. A., Conjusteau, A., & Motamedi, M. (2007) · Nano Letters · doi:10.1021/nl070557d · Cited by 374
Self-citationLi, M.-L., Oh, J.-T., Xie, X., Ku, G., Wang, W., Li, C., Lungu, G., Stoica, G., & Wang, L. V. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2007.913515 · Cited by 352
Self-citationLu, W., Xiong, C., Zhang, G., Huang, Q., Zhang, R., Zhang, J. Z., & Li, C. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-1480 · Cited by 322
Self-citationManohar, S., Vaartjes, S. E., van Hespen, J. C. G., Klaase, J. M., van den Engh, F. M., Steenbergen, W., & van Leeuwen, T. G. (2007) · Optics Express · doi:10.1364/oe.15.012277 · Cited by 287
Li, P.-C., Shieh, D.-B., Wang, C.-R., Wei, C.-W., Liao, C.-K., Ding, A.-A., Wu, Y.-N., Poe, C., & Jhan, S. (2008) · Nature Precedings · doi:10.1038/npre.2008.1687.1 · Cited by 259
Eghtedari, M., Liopo, A. V., Copland, J. A., Oraevsky, A. A., & Motamedi, M. (2009) · Nano Letters · doi:10.1021/nl802915q · Cited by 226
Self-citationWang, B., Yantsen, E., Larson, T., Karpiouk, A. B., Sethuraman, S., Su, J. L., Sokolov, K., & Emelianov, S. Y. (2009) · Nano Letters · doi:10.1021/nl801852e · Cited by 208
Lu, W., Wan, J., She, Z., & Jiang, X. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.11.015 · Cited by 193
Self-citationPhotoacoustic imaging of early inflammatory response using gold nanorods
Kim, K., Huang, S.-W., Ashkenazi, S., O’Donnell, M., Agarwal, A., Kotov, N. A., Denny, M. F., & Kaplan, M. J. (2007) · Applied Physics Letters · doi:10.1063/1.2743752 · Cited by 159
Photoacoustic Imaging of Multiple Targets Using Gold Nanorods
Li, P.-C., Wei, C.-W., Liao, C.-K., et al. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.435 · Cited by 125
In-vivo photoacoustic microscopy of nanoshell extravasation from solid tumor vasculature
Li, M., Wang, J. C., Schwartz, J. A., Gill‐Sharp, K. L., Stoica, G., & Wang, L. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3081556 · Cited by 124
Self-citationChamberland, D. L., Agarwal, A., Kotov, N. A., Fowlkes, J. B., Carson, P. L., & Wang, X. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/9/095101 · Cited by 115
In vivo imaging and characterization of hypoxia-induced neovascularization and tumor invasion
Lungu, G. F., Li, M., Xie, X., Wang, L. V., & Stoica, G. (2007) · International Journal of Oncology · doi:10.3892/ijo.30.1.45 · Cited by 98
Self-citationMolecular Photoacoustic Tomography with Colloidal Nanobeacons
Pan, D., Pramanik, M., Senpan, A., Yang, X., Song, K. H., Scott, M. J., Zhang, H., Gaffney, P. J., Wickline, S. A., Wang, L. V., et al. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805947 · Cited by 95
Self-citationGold-Speckled Multimodal Nanoparticles for Noninvasive Bioimaging
Sharma, P., Brown, S. C., Bengtsson, N. E., Zhang, Q., Walter, G. A., Grobmyer, S. R., Santra, S., Jiang, H., Scott, E. W., & Moudgil, B. M. (2008) · Chemistry of Materials · doi:10.1021/cm801020s · Cited by 82
Splenic Trapping of Nanoparticles: Complementary Approaches for In Situ Studies
Demoy, M., Gibaud, S., Andreux, J. P., Weingarten, C., Gouritin, B., & Couvreur, P. (1997) · Pharmaceutical Research · doi:10.1023/a:1012095431931 · Cited by 62
Cited by
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El-Sayed, M. A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15237h · Cited by 3,550
Synthesis, Properties, and Applications of Hollow Micro-/Nanostructures
Wang, X., Feng, J., Bai, Y., Zhang, Q., & Yin, Y. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00731 · Cited by 1,456
Nanomaterials for Theranostics: Recent Advances and Future Challenges
Lim, E.-K., Kim, T., Paik, S., Haam, S., Huh, Y.-M., & Lee, K. (2015) · Chemical Reviews · doi:10.1021/cr300213b · Cited by 1,233
The unique role of nanoparticles in nanomedicine: imaging, drug delivery and therapy
Doane, T. L., & Burda, C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15260f · Cited by 1,098
The Smart Drug Delivery System and Its Clinical Potential
Liu, D., Yang, F., Xiong, F., & Gu, N. (2016) · Theranostics · doi:10.7150/thno.14858 · Cited by 1,066
Metadata
- Authors
- Lu, W., Huang, Q., Ku, G., Wen, X., Zhou, M., Guzatov, D., Brecht, P., Su, R., Oraevsky, A., Wang, L. V., & Li, C.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 31
- Issue
- 9
- Pages
- 2617-2626
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2148332810
- Cited by
- 325
- References
- 38
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.