The relationship between glial cell mechanosensitivity and foreign body reactions in the central nervous system
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Devices implanted into the body become encapsulated due to a foreign body reaction. In the central nervous system (CNS), this can lead to loss of functionality in electrodes used to treat disorders. Around CNS implants, glial cells are activated, undergo gliosis and ultimately encapsulate the electrodes. The primary cause of this reaction is unknown. Here we show that the mechanical mismatch between nervous tissue and electrodes activates glial cells. Both primary rat microglial cells and astrocytes responded to increasing the contact stiffness from physiological values (G' ∼ 100 Pa) to shear moduli G' ≥ 10 kPa by changes in morphology and upregulation of inflammatory genes and proteins. Upon implantation of composite foreign bodies into rat brains, foreign body reactions were significantly enhanced around their stiff portions in vivo. Our results indicate that CNS glial cells respond to mechanical cues, and suggest that adapting the surface stiffness of neural implants to that of nervous tissue could minimize adverse reactions and improve biocompatibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploration, normalization, and summaries of high density oligonucleotide array probe level data
Irizarry, R. A. (2003) · Biostatistics · doi:10.1093/biostatistics/4.2.249 · Cited by 10,603
Microglia: a sensor for pathological events in the CNS
Kreutzberg, G. W. (1996) · Trends in Neurosciences · doi:10.1016/0166-2236(96)10049-7 · Cited by 4,396 · cited 1×
“1B) [23].”
Kettenmann, H., Hanisch, U.-K., Noda, M., & Verkhratsky, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00011.2010 · Cited by 3,547
Regeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1326 · Cited by 3,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Astrocyte activation and reactive gliosis
Pekny, M., & Nilsson, M. (2005) · Glia · doi:10.1002/glia.20207 · Cited by 1,611
A Pericyte Origin of Spinal Cord Scar Tissue
Göritz, C., Dias, D. O., Tomilin, N., Barbacid, M., Shupliakov, O., & Frisén, J. (2011) · Science · doi:10.1126/science.1203165 · Cited by 858 · cited 1×
“It is possible that glial reactions tomechanical cues and/or distributions of other cells which may contribute to glial scarring, such as pericytes [25], are cortical layer-specific.”
BackgroundNeurite branching on deformable substrates
Flanagan, L. A., Ju, Y.-E., Marg, B., Osterfield, M., & Janmey, P. A. (2002) · NeuroReport · doi:10.1097/00001756-200212200-00007 · Cited by 759
Georges, P. C., Miller, W. J., Meaney, D. F., Sawyer, E. S., & Janmey, P. A. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.073114 · Cited by 724
Viscoelastic properties of individual glial cells and neurons in the CNS
Lu, Y.-B., Franze, K., Seifert, G., Steinhäuser, C., Kirchhoff, F., Wolburg, H., Guck, J., Janmey, P., Wei, E.-Q., Käs, J., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606150103 · Cited by 578
Self-citation
Cited by
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Engineered biomaterials for in situ tissue regeneration
Gaharwar, A. K., Singh, I., & Khademhosseini, A. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0209-x · Cited by 859
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Self-citationMechanically activated ion channel Piezo1 modulates macrophage polarization and stiffness sensing
Atcha, H., Jairaman, A., Holt, J. R., Meli, V. S., Nagalla, R. R., Veerasubramanian, P. K., Brumm, K. T., Lim, H. E., Othy, S., Cahalan, M. D., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23482-5 · Cited by 644
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“Improved softness— Stiff substrates, including silicon, exacerbate the activation of both astrocytes and microglia compared with softer materials 158 .”
InfluentialEmerging flexible and wearable physical sensing platforms for healthcare and biomedical applications
Kenry, Yeo, J. C., & Lim, C. T. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.43 · Cited by 550
The soft mechanical signature of glial scars in the central nervous system
Moeendarbary, E., Weber, I. P., Sheridan, G. K., Koser, D. E., Soleman, S., Haenzi, B., Bradbury, E. J., Fawcett, J., & Franze, K. (2017) · Nature Communications · doi:10.1038/ncomms14787 · Cited by 406
Self-citationBiological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., A. Heyward, C., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 391
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Questions and (some) answers on reactive astrocytes
Escartin, C., Guillemaud, O., & Carrillo‐de Sauvage, M. (2019) · Glia · doi:10.1002/glia.23687 · Cited by 275
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
“facilitating differences in the foreign body response (37).”
BackgroundKozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
“For instance, a recent study showed that neural immune cells respond to mechanical cues in vitro as well as in vivo, where the ‘stiff’ probes used in the study had an elastic modulus of 10–30 kPa and ‘flexible’ probes a modulus of 100 Pa [45].”
BackgroundThe Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201
Implant Fibrosis and the Underappreciated Role of Myofibroblasts in the Foreign Body Reaction
Noskovicova, N., Hinz, B., & Pakshir, P. (2021) · Cells · doi:10.3390/cells10071794 · Cited by 184
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J., & Meng, E. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 184
“Elevated GFAP levels indicate the presence of activated astrocytic cells, which suggests that mechanical mismatch between electrodes and nervous tissue may enhance unfavorable tissue reactions to the implant that impair its performance [27].”
BackgroundCNS Cell Distribution and Axon Orientation Determine Local Spinal Cord Mechanical Properties
Koser, D. E., Moeendarbary, E., Hanne, J., Kuerten, S., & Franze, K. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.03.039 · Cited by 177
“Accordingly, after introducing implants into the CNS, whose stiffness is orders of magnitude higher than that of the tissue, cells respond to the mechanical signals generated by the implant with an inflammatory reaction, culminating in a foreign body reaction (12).”
Self-citationMechanical Mapping of Spinal Cord Growth and Repair in Living Zebrafish Larvae by Brillouin Imaging
Schlüßler, R., Möllmert, S., Abuhattum, S., Cojoc, G., Müller, P., Kim, K., Möckel, C., Zimmermann, C., Czarske, J., & Guck, J. (2018) · Biophysical Journal · doi:10.1016/j.bpj.2018.07.027 · Cited by 170
“phenotype and increase expression of inflammatory genes and proteins, which is indicative of reactive gliosis, when exposed to a mechanical stimulus that deviates from their physiological mechanical environment (12).”
BackgroundSelf-citationKozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Conformable polyimide-based μECoGs: Bringing the electrodes closer to the signal source
Vomero, M., Porto Cruz, M. F., Zucchini, E., Ciarpella, F., Delfino, E., Carli, S., Boehler, C., Asplund, M., Ricci, D., Fadiga, L., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120178 · Cited by 95
Tang, Y., Zhao, C., Zhuang, Y., Zhong, A., Wang, M., Zhang, W., & Zhu, L. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1149336 · Cited by 67
“Thus, microglia are attracted to stiff regions in vitro and activated by implantation of stiff foreign bodies in vivo, implying the presence of specific mechanosensors in microglia (51, 52).”
BackgroundPrevention of the foreign body response to implantable medical devices by inflammasome inhibition
Barone, D. G., Carnicer-Lombarte, A., Tourlomousis, P., Hamilton, R. S., Prater, M., Rutz, A. L., Dimov, I. B., Malliaras, G. G., Lacour, S. P., Robertson, A. A. B., et al. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2115857119 · Cited by 67
Self-citationHigh Density, Double-Sided, Flexible Optoelectronic Neural Probes With Embedded μLEDs
Reddy, J. W., Kimukin, I., Stewart, L. T., Ahmed, Z., Barth, A. L., Towe, E., & Chamanzar, M. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00745 · Cited by 55
Carnicer-Lombarte (2019) · doi:10.1101/829648 · Cited by 46
The Role of Macrophages in the Foreign Body Response to Implanted Biomaterials
Yu, T., Tutwiler, V. J., & Spiller, K. (2015) · Biomaterials in Regenerative Medicine and the Immune System · doi:10.1007/978-3-319-18045-8_2 · Cited by 39
Physics and Physiology of Cell Spreading in Two and Three Dimensions
Janmey, P. A., Hinz, B., & McCulloch, C. A. (2021) · Physiology · doi:10.1152/physiol.00020.2021 · Cited by 23
NeuroBus - Architecture for an Ultra-Flexible Neural Interface
Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3354785 · Cited by 13
Metadata
- Authors
- Moshayedi, P., Ng, G., Kwok, J. C. F., Yeo, G. S. H., Bryant, C. E., Fawcett, J. W., Franze, K., & Guck, J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2014-04
- Volume
- 35
- Issue
- 13
- Pages
- 3919-3925
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2001379153
- Cited by
- 394
- References
- 33
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.