Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Stable interconnection to neurons in vivo over long time-periods is critical for the success of future advanced neuroelectronic applications. The inevitable foreign body reaction towards implanted materials challenges the stability and an active intervention strategy would be desirable to treat inflammation locally. Here, we investigate whether controlled release of the anti-inflammatory drug Dexamethasone from flexible neural microelectrodes in the rat hippocampus has an impact on probe-tissue integration over 12 weeks of implantation. The drug was stored in a conducting polymer coating (PEDOT/Dex), selectively deposited on the electrode sites of neural probes, and released on weekly basis by applying a cyclic voltammetry signal in three electrode configuration in fully awake animals. Dex-functionalized probes provided stable recordings and impedance characteristics over the entire chronic study. Histological evaluation after 12 weeks of implantation revealed an overall low degree of inflammation around all flexible probes whereas electrodes exposed to active drug release protocols did have neurons closer to the electrode sites compared to controls. The combination of flexible probe technology with anti-inflammatory coatings accordingly offers a promising approach for enabling long-term stable neural interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343
Self-citationLudwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230
Kozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
Winslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Azemi, E., Lagenaur, C. F., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.033 · Cited by 164
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
Bhardwaj, U., Sura, R., Papadimitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100103 · Cited by 99
Ward, W. K., Hansen, J. C., Massoud, R. G., Engle, J. M., Takeno, M. M., & Hauch, K. D. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32651 · Cited by 26
Cited by
Recent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Long-term functionality of transversal intraneural electrodes is improved by dexamethasone treatment
de la Oliva, N., del Valle, J., Delgado-Martinez, I., Mueller, M., Stieglitz, T., & Navarro, X. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2897256 · Cited by 26
Self-citation
Metadata
- Authors
- Boehler, C., Kleber, C., Martini, N., Xie, Y., Dryg, I., Stieglitz, T., Hofmann, U. G., & Asplund, M.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2017-06
- Volume
- 129
- Pages
- 176-187
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2595239703
- Cited by
- 196
- References
- 19
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.