Long-term functionality of transversal intraneural electrodes is improved by dexamethasone treatment
Open accessAbstract
Neuroprostheses aimed to restore lost functions after a limb amputation are based on the interaction with the nervous system by means of neural interfaces. Among the different designs, intraneural electrodes implanted in peripheral nerves represent a good strategy to stimulate nerve fibers to send sensory feedback and to record nerve signals to control the prosthetic limb. However, intraneural electrodes, as any device implanted in the body, induce a foreign body reaction (FBR) that results in the tissue encapsulation of the device. The FBR causes a progressive decline of the electrode functionality over time due to the physical separation between the electrode active sites and the axons to interface. Modulation of the inflammatory response has arisen as a good strategy to reduce the FBR and maintain electrode functionality. In this study transversal intraneural multi-channel electrodes (TIMEs) were implanted in the rat sciatic nerve and tested for 3 months to evaluate stimulation and recording capabilities under chronic administration of dexamethasone. Dexamethasone treatment significantly reduced the threshold for evoking muscle responses during the follow-up compared to saline-treated animals, without affecting the selectivity of stimulation. However, dexamethasone treatment did not improve the signal-to-noise ratio of the recorded neural signals. Dexamethasone treatment allowed to maintain more working active sites along time than saline treatment. Thus, systemic administration of dexamethasone appears as a useful treatment in chronically implanted animals with neural electrodes as it increases the number of functioning contacts of the implanted TIME and reduces the intensity needed to stimulate the nerve.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dexamethasone administered systemically has been shown to improve electrical stimulation properties using TIME implants over a 3-month implantation period.
“Dexamethasone administered systemically has also been shown to improve the electrical stimulation properties using TIME implants over a 3-month implantation period (Oliva et al., 2019).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Oliva et al., 2019
The Results report improved stimulation measures with dexamethasone-treated TIME implants, but state that electrophysiological comparisons were possible only through one month because some wiring systems were damaged. Animals were followed for three months, but the Conclusion limits the demonstrated stimulation benefit to the first month of implantation. (LLM, conf=0.93)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Dose translation from animal to human studies revisited.
Reagan‐Shaw, S., Nihal, M., & Ahmad, N. (2008) · The FASEB Journal · doi:10.1096/fj.07-9574lsf · Cited by 6,524 · see citing works
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1× · see citing works
“(FBR) triggered after the implantation of the device [6], [7].”
BackgroundCoutinho, A. E., & Chapman, K. E. (2011) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2010.04.005 · Cited by 1,815 · see citing works
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · see citing works
Self-citationNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2× · see citing works
“Peripheral nerve electrodes are a key component of neuroprostheses, as they are the active part that will interact with the nervous tissue [1].”
BackgroundSelf-citationA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · cited 1× · see citing works
“The electrode used was a transversal intrafascicular multichannel electrode (TIME version 3H; developed by the Department of Microsystems Engineering-IMTEK, University of Freiburg, Germany) [29], [30].”
MethodSelf-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · see citing works
Ward, W. K. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200504 · Cited by 328 · see citing works
Oddo, C. M., Raspopović, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F. M., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 328 · see citing works
Zhong, Y., & Bellamkonda, R. V. (2007) · Brain Research · doi:10.1016/j.brainres.2007.02.024 · Cited by 321 · see citing works
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · see citing works
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Self-citationIn vivo impedance spectroscopy of deep brain stimulation electrodes
Lempka, S. F., Miocinovic, S., Johnson, M. D., Vitek, J. L., & McIntyre, C. C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046001 · Cited by 226 · see citing works
Spataro, L. E., Dilgen, J., Retterer, S. T., Spence, A. J., Isaacson, M. S., Turner, J. N., & Shain, W. G. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215 · see citing works
Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study
Boehler, C., Kleber, C., Martini, N., Xie, Y., Dryg, I., Stieglitz, T., Hofmann, U., & Asplund, M. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.019 · Cited by 198 · see citing works
Self-citationLong-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176 · see citing works
Self-citationThe foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135 · see citing works
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128 · see citing works
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103 · see citing works
Self-citationMicera, S., Citi, L., Rigosa, J., Carpaneto, J., Raspopović, S., Pino, G. D., Rossini, L., Yoshida, K., Denaro, L., Dario, P., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038726 · Cited by 100 · see citing works
Steroids as pain relief adjuvants.
Vyvey, M. (2010) · PubMed · Cited by 97 · see citing works
A three-dimensional self-opening intraneural peripheral interface (SELINE)
Cutrone, A., Valle, J. D., Santos, D., Badia, J., Filippeschi, C., Micera, S., Navarro, X., & Bossi, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016016 · Cited by 82 · see citing works
Self-citationOn the use of Parylene C polymer as substrate for peripheral nerve electrodes
de la Oliva, N., Mueller, M. C., Stieglitz, T., Navarro, X., & del Valle, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-24502-z · Cited by 82 · see citing works
Self-citationRaspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81 · see citing works
Self-citationAC impedance of the perineurium of the frog sciatic nerve
Weerasuriya, A., Spangler, R. A., Рапопорт, С. И., & Taylor, R. E. (1984) · Biophysical Journal · doi:10.1016/s0006-3495(84)84009-6 · Cited by 80 · see citing works
Boddupalli, A., Zhu, L., & Bratlie, K. M. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600532 · Cited by 77 · see citing works
Badia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2440768 · Cited by 65 · see citing works
Self-citationSkousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61 · see citing works
de la Oliva, N., Navarro, X., & del Valle, J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36274 · Cited by 58 · see citing works
Self-citationKastellorizios, M., Papadimitrakopoulos, F., & Burgess, D. J. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.07.021 · Cited by 55 · see citing works
Noorisafa, F., Razmjou, A., Emami, N., et al. (2016) · Journal of Experimental Nanoscience · doi:10.1080/17458080.2016.1188223 · Cited by 51 · see citing works
Material considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47 · see citing works
Sommakia, S., Lee, H. C., Gaire, J., & Otto, K. J. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.005 · Cited by 47 · see citing works
Park, S. J., Lee, Y. J., Heo, D. N., Kwon, I. K., Yun, K., Kang, J. Y., & Lee, S. H. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.036 · Cited by 37 · see citing works
de la Oliva, N., Navarro, X., & del Valle, J. (2018) · The Anatomical Record · doi:10.1002/ar.23920 · Cited by 34 · see citing works
Self-citationProspects of common biomolecules as coating substances for polymeric biomaterials
Balaji, A., Jaganathan, S. K., Vellayappan, M. V., et al. (2015) · RSC Advances · doi:10.1039/c5ra12693b · Cited by 28 · see citing works
Suppression of scarring in peripheral nerve implants by drug elution
FitzGerald, J. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026006 · Cited by 27 · see citing works
Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring
Mueller, M. C., de la Oliva, N., del Valle, J., Delgado-Martínez, I., Navarro, X., & Stieglitz, T. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7eea · Cited by 24 · see citing works
Self-citationExtracellular matrix-based materials for neural interfacing
Chen, S., & Allen, M. G. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.120 · Cited by 22 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- International Organization for Standardization, Biological evaluation of medical devices, vol. 3. 2009.
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“Dexamethasone administered systemically has also been shown to improve the electrical stimulation properties using TIME implants over a 3-month implantation period (Oliva et al., 2019).”
BackgroundA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
“A study with TIME electrodes showed positive effects of systemic dexamethasone administration on decreasing foreign body reaction, further ensuring the chronic functionality [190].”
Method
- Authors
- de la Oliva, N., del Valle, J., Delgado-Martinez, I., Mueller, M., Stieglitz, T., & Navarro, X.
- Affiliations
- University of Freiburg (DE)
- Universitat Autònoma de Barcelona (ES)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2019-03
- Volume
- 27
- Issue
- 3
- Pages
- 457-464
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2911370961
- Cited by
- 26
- References
- 40
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 7 · 2019: 1
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- green
- ddd.uab.cat
- Licence
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Dipòsit Digital de Documents de la UAB (Universitat Autònoma de Barcelona) (submittedVersion, public-domain)
- DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, public-domain)
- Funders
- FP7 Information and Communication Technologies (FP7-611687, EPIONE (FP7-602547))
- European Union’s Horizon 2020 Graphene Flagship Core Project 2 (785219)
- H2020 Future and Emerging Technologies
- TERCEL (RD12/0019/0011)
- CIBERNED (CB06/05/1105)
- Instituto de Salud Carlos III
- Fundación Ramón Areces (CIVP18A3897)
- ICN2
- Ministerio de Economía y Competitividad (SEV-2013-0295)
- Generalitat de Catalunya
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- dexamethasone, foreign body reaction, peripheral nerve stimulation, neural recording, sciatic nerve, chronic implantation, neural prostheses, amputation, anti-inflammatory therapy, signal-to-noise ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review