The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Lactate biosensing: The emerging point-of-care and personal health monitoring
Abstract
Lactate plays a crucial role in the anaerobic metabolic pathway of humans. In situations of oxygen deficit, its production increases; leading to several life-threatening conditions such as hemorrhage, respiratory failure, trauma or ischemia from lactate acidosis. Lactate level detection and point-of-care (POC) monitoring in a fast, accurate and non-invasive manner is ultimately important for many health care applications. Optical and electrochemical techniques are employed in lactate sensing to achieve high sensitivity and selectivity, miniaturization, portability, simplicity, and low cost. To improve the selectivity and sensitivity, two important enzymes, lactate oxidase (LOx) and lactate dehydrogenese (LDH) are employed. Conventional methods for lactate detection are not fast enough to be used in point-of-care or personal health monitoring settings. Moreover, the existing point-of-care lactate sensing tools follow invasive or partially invasive sampling protocols such as finger pricking. In this review, a comprehensive overview of different lactate biosensing devices is presented. Particularly, the state-of-the-art and prospects of wearable, non-invasive lactate sensing from different biofluids are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Saliva Composition and Exercise
Chicharro, J. L., Lucía, A., Pérez, M., Vaquero, A. F., & Ureña, R. (1998) · Sports Medicine · doi:10.2165/00007256-199826010-00002 · Cited by 345
Epidermal Biofuel Cells: Energy Harvesting from Human Perspiration
Jia, W., Valdés‐Ramírez, G., Bandodkar, A. J., Windmiller, J. R., & Wang, J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201302922 · Cited by 324
Eyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311
Disposable electrochemiluminescent biosensor for lactate determination in saliva
Ballesta Claver, J., Valencia Mirón, M. C., & Capitán-Vallvey, L. F. (2009) · The Analyst · doi:10.1039/b821922b · Cited by 93
Cai, X., Yan, J., Chu, H., Wu, M., & Tu, Y. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.10.002 · Cited by 71
Effects of a 30-km race upon salivary lactate correlation with blood lactate
Santos, R. V. T., Almeida, A. L. R., Caperuto, E. C., Martins, E., & Costa Rosa, L. F. B. P. (2006) · Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology · doi:10.1016/j.cbpb.2006.07.001 · Cited by 51
Wearable near Infrared Sensor for Determining an Athlete's Lactate Threshold during Exercise
Driller, M., Plews, D., & Borges, N. (2016) · NIR news · doi:10.1255/nirn.1609 · Cited by 9
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Energy metabolism in health and diseases
Liu, H., Wang, S., Wang, J., Guo, X., Song, Y., Fu, K., Gao, Z., Liu, D., He, W., & Yang, L.-L. (2025) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-025-02141-x · Cited by 399
Nanozymes in Point-of-Care Diagnosis: An Emerging Futuristic Approach for Biosensing
Das, B., Franco, J. L., Logan, N., Balasubramanian, P., Kim, M. I., & Cao, C. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00717-0 · Cited by 263
Recent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187
Metadata
- Authors
- Alam, F., RoyChoudhury, S., Jalal, A. H., Umasankar, Y., Forouzanfar, S., Akter, N., Bhansali, S., & Pala, N.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 117
- Pages
- 818-829
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2810788601
- Cited by
- 199
- References
- 16
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.