Microneedle-based biosensor for minimally-invasive lactate detection
Abstract
Here we report the first mediated microneedles-based biosensor for minimally invasive continuous sensing of lactate in the dermal interstitial fluid (ISF). To further demonstrate the capability of microneedle arrays as second generation biosensors we have functionalized gold microneedles with nanocarbons at which mediated electron transfer of lactate oxidase takes place. In particular the gold surface of the microneedles electrode has been modified in 3 subsequent steps: i) electrodeposition of Au-multiwalled carbon nanotubes (MWCNTs); ii) electropolymerization of the mediator, methylene blue (MB); iii) immobilization of the enzyme lactate oxidase (LOX) by drop-casting procedure. The resulting microneedle-based LOX biosensor displays an interference-free lactate detection without compromising its sensitivity, stability, selectivity and response time. The performance of the microneedle array, second generation biosensor for lactate detection was assessed in artificial interstitial fluid and in human serum, both spiked with lactate. The results reveal that the new microneedles lactate sensor holds interesting promise for the development of a real-time monitoring device to be used in sport medicine and clinical care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lactate: A Metabolic Key Player in Cancer
Hirschhaeuser, F., Sattler, U. G. A., & Mueller-Klieser, W. (2011) · Cancer Research · doi:10.1158/0008-5472.can-11-1457 · Cited by 1,090
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Electrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes
Gupta, V. K., Ganjali, M. R., Norouzi, P., Khani, H., Nayak, A., & Agarwal, S. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.589773 · Cited by 580
Blood Lactate Measurements and Analysis during Exercise: A Guide for Clinicians
Goodwin, M. L., Harris, J. E., Hernández, A., & Gladden, L. B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100414 · Cited by 554
Anaerobic threshold: review of the concept and directions for future research
BROOKS, G. A. (1985) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198502000-00005 · Cited by 553
Karthikeyan, S., Gupta, V. K., Boopathy, R., Titus, A., & Sekaran, G. (2012) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2012.06.022 · Cited by 546
Thiazole Schiff base turn-on fluorescent chemosensor for Al3+ ion
Gupta, V. K., Singh, A. K., & Kumawat, L. K. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.12.092 · Cited by 460
Dehghani, M. H., Sanaei, D., Ali, I., & Bhatnagar, A. (2016) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2015.12.057 · Cited by 459
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Yola, M. L., Gupta, V. K., Eren, T., Şen, A. E., & Atar, N. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2013.12.086 · Cited by 417
Karimi-Maleh, H., Tahernejad-Javazmi, F., Atar, N., Yola, M. L., Gupta, V. K., & Ensafi, A. A. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/ie504438z · Cited by 412
Gupta, V. K., Sethi, B., Sharma, R. A., Agarwal, S., & Bharti, A. (2013) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2012.10.008 · Cited by 374
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Biosensors based on electrochemical lactate detection: A comprehensive review
Rathee, K., Dhull, V., Dhull, R., & Singh, S. (2016) · Biochemistry and Biophysics Reports · doi:10.1016/j.bbrep.2015.11.010 · Cited by 362
Gupta, V. K., Singh, L. P., Singh, R., Upadhyay, N., Kaur, S. P., & Sethi, B. (2012) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2012.07.016 · Cited by 361
Caesium PVC–crown (dibenzo-24-crown-8) based membrane sensor
Srivastava, S. K., Gupta, V. K., Dwivedi, M. K., & Jain, S. (1995) · Anal. Proc. · doi:10.1039/ai9953200021 · Cited by 285
Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays
Mohan, A. M. V., Windmiller, J. R., Mishra, R. K., & Wang, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.016 · Cited by 274
Lactate physiology in health and disease
Phypers, B., & Pierce, J. T. (2006) · Continuing Education in Anaesthesia Critical Care & Pain · doi:10.1093/bjaceaccp/mkl018 · Cited by 253
Bench-to-bedside review: lactate and the kidney.
Bellomo, R. (2002) · Critical Care · doi:10.1186/cc1518 · Cited by 237
Microneedles for Transdermal Biosensing: Current Picture and Future Direction
Ventrelli, L., Marsilio Strambini, L., & Barillaro, G. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500450 · Cited by 235
A contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Lactate biosensors: current status and outlook
Rassaei, L., Olthuis, W., Tsujimura, S., Sudhölter, E. J. R., & van den Berg, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7307-1 · Cited by 195
Lactate Production by the Lungs in Acute Lung Injury
DE BACKER, D., CRETEUR, J., ZHANG, H., NORRENBERG, M., & VINCENT, J.-L. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.4.9701048 · Cited by 190
Microneedle-based self-powered glucose sensor
Valdés-Ramírez, G., Li, Y.-C., Kim, J., Jia, W., Bandodkar, A. J., Nuñez-Flores, R., Miller, P. R., Wu, S.-Y., Narayan, R., Windmiller, J. R., et al. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.07.014 · Cited by 188
Systemic lactate kinetics during graded exercise in man
Stanley, W. C., Gertz, E. W., Wisneski, J. A., Morris, D. L., Neese, R. A., & Brooks, G. A. (1985) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1985.249.6.e595 · Cited by 163
Hickey, D. P., Reid, R. C., Milton, R. D., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.013 · Cited by 160
Microneedle array-based carbon paste amperometric sensors and biosensors
Windmiller, J. R., Zhou, N., Chuang, M.-C., Valdés-Ramírez, G., Santhosh, P., Miller, P. R., Narayan, R., & Wang, J. (2011) · The Analyst · doi:10.1039/c1an00012h · Cited by 160
Nikolaus, N., & Strehlitz, B. (2007) · Microchimica Acta · doi:10.1007/s00604-007-0834-8 · Cited by 142
Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring
Sharma, S., Huang, Z., Rogers, M. L., Boutelle, M. G., & Cass, A. E. G. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9961-6 · Cited by 140
Self-citationMicroneedle-based sensors for medical diagnosis
Miller, P. R., Narayan, R. J., & Polsky, R. (2016) · Journal of Materials Chemistry B · doi:10.1039/c5tb02421h · Cited by 137
Use of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
El-Laboudi, A. H., Oliver, N. S., Cass, A. E. G., & Johnston, D. G. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0188 · Cited by 135
Self-citationMultiplexed microneedle-based biosensor array for characterization of metabolic acidosis
Miller, P. R., Skoog, S. A., Edwards, T. L., et al. (2011) · Talanta · doi:10.1016/j.talanta.2011.11.046 · Cited by 134
Lactate as a marker of energy failure in critically ill patients: hypothesis.
Valenza, F., Aletti, G., Fossali, T., Chevallard, G., Sacconi, F., Irace, M., & Gattinoni, L. (2005) · Critical Care · doi:10.1186/cc3818 · Cited by 130
Influence of Electrode Roughness on Cyclic Voltammetry
Menshykau, D., Streeter, I., & Compton, R. G. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp8047423 · Cited by 121
Significance of blood lactate levels in critically III patients with liver disease
Kruse, J. A., Zaidi, S. A., & Carlson, R. W. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90500-6 · Cited by 116
Bendable Electro-chemical Lactate Sensor Printed with Silver Nano-particles
Abrar, M. A., Dong, Y., Lee, P. K., & Kim, W. S. (2016) · Scientific Reports · doi:10.1038/srep30565 · Cited by 105
Lactate/Pyruvate Ratio as a Marker of Tissue Hypoxia in Circulatory and Septic Shock
Rimachi, R., Carvahlo, F. B., Orellano-Jimenez, C., COTTON, F. J., Vincent, J., & Backer, D. D. (2012) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1204000307 · Cited by 102
Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring
Sharma, S., Saeed, A., Johnson, C., Gadegaard, N., & Cass, A. E. G. (2016) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.10.004 · Cited by 102
Self-citationLamas‐Ardisana, P. J., Loaiza, Ó. A., Añorga, L., Jubete, E., Borghei, M., Ruiz, V., Ochoteco, E., Cabañero, G., & Grande, H. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.01.047 · Cited by 101
Diagnostic opportunities based on skin biomarkers
Paliwal, S., Hwang, B. H., Tsai, K. Y., & Mitragotri, S. (2012) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2012.10.009 · Cited by 82
Development of a disposable biosensor for lactate monitoring in saliva
Πετρόπουλος, Κ., Piermarini, S., Bernardini, S., Palleschi, G., & Moscone, D. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.06.068 · Cited by 79
Nanoparticle-modified electrodes
Belding, S. R., Campbell, F. W., Dickinson, E. J. F., & Compton, R. G. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/c0cp00233j · Cited by 69
Chronoamperometric determination of d-lactate using screen-printed enzyme electrodes
Vasilescu, A., Noguer, T., Magearu, V., & Marty, J. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)01386-6 · Cited by 60
Chen, Q., Sun, T. P., Song, X., Ran, Q., Yu, C., Yang, J., Feng, H., Yu, L., & Wei, D. (2017) · Nanotechnology · doi:10.1088/1361-6528/aa78bc · Cited by 60
Ghamouss, F., Ledru, S., Ruillé, N., Lantier, F., & Boujtita, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.022 · Cited by 58
High-performance liquid chromatographic assay of (±)-lactic acid and its enantiomers in calf serum
Omole, O. O., Brocks, D. R., Nappert, G., Naylor, J. Μ., & Zello, G. A. (1999) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00072-9 · Cited by 50
Microneedle Enzyme Sensor Arrays for Continuous In Vivo Monitoring
Cass, A. E. G., & Sharma, S. (2017) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2017.02.002 · Cited by 42
Self-citationKarlsson, J., Willerson, J. T., Leshin, S. J., Mullins, C. B., & Mitchell, J. H. (1975) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365517509068008 · Cited by 36
Collier, W. A., Lovejoy, P., & Hart, A. L. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00011-0 · Cited by 33
Ren, J., Sherry, A. D., & Malloy, C. R. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24526 · Cited by 20
Saito, N., Adachi, H., Tanaka, H., Nakata, S., Kawada, N., Oofusa, K., & Yoshizato, K. (2017) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2017.06.019 · Cited by 14
Cited by
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Goud, K. Y., Moonla, C., Mishra, R. K., Yu, C., Narayan, R., Litvan, I., & Wang, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01127 · Cited by 354
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Nanomaterials for Healthcare Biosensing Applications
Pirzada, M., & Altintas, Z. (2019) · Sensors · doi:10.3390/s19235311 · Cited by 253
Metadata
- Authors
- Bollella, P., Sharma, S., Cass, A. E. G., & Antiochia, R.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 123
- Pages
- 152-159
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2885161568
- Cited by
- 267
- References
- 51
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.