The DOI matches its Crossref record; 128 of the 128 references it cites were found in a registry or an index.
Detection of COVID-19: A review of the current literature and future perspectives
Open accessAbstract
The rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has led to the coronavirus disease 2019 (COVID-19) worldwide pandemic. This unprecedented situation has garnered worldwide attention. An effective strategy for controlling the COVID-19 pandemic is to develop highly accurate methods for the rapid identification and isolation of SARS-CoV-2 infected patients. Many companies and institutes are therefore striving to develop effective methods for the rapid detection of SARS-CoV-2 ribonucleic acid (RNA), antibodies, antigens, and the virus. In this review, we summarize the structure of the SARS-CoV-2 virus, its genome and gene expression characteristics, and the current progression of SARS-CoV-2 RNA, antibodies, antigens, and virus detection. Further, we discuss the reasons for the observed false-negative and false-positive RNA and antibody detection results in practical clinical applications. Finally, we provide a review of the biosensors which hold promising potential for point-of-care detection of COVID-19 patients. This review thereby provides general guidelines for both scientists in the biosensing research community and for those in the biosensor industry to develop a highly sensitive and accurate point-of-care COVID-19 detection system, which would be of enormous benefit for controlling the current COVID-19 pandemic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A pneumonia outbreak associated with a new coronavirus of probable bat origin
Zhou, P., Yang, X.-L., Wang, X.-G., Hu, B., Zhang, L., Zhang, W., Si, H.-R., Zhu, Y., Li, B., Huang, C.-L., et al. (2020) · Nature · doi:10.1038/s41586-020-2012-7 · Cited by 21,969
Self-citationHoffmann, M., Kleine-Weber, H., Schroeder, S., Krüger, N., Herrler, T., Erichsen, S., Schiergens, T. S., Herrler, G., Wu, N.-H., Nitsche, A., et al. (2020) · Cell · doi:10.1016/j.cell.2020.02.052 · Cited by 20,286
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344
Lauer, S. A., Grantz, K. H., Bi, Q., Jones, F. K., Zheng, Q., Meredith, H. R., Azman, A. S., Reich, N. G., & Lessler, J. (2020) · Annals of Internal Medicine · doi:10.7326/m20-0504 · Cited by 5,970
Detection of SARS-CoV-2 in Different Types of Clinical Specimens
Wang, W., Xu, Y., Gao, R., Lu, R., Han, K., Wu, G., & Tan, W. (2020) · JAMA · doi:10.1001/jama.2020.3786 · Cited by 5,028
Li, R., Pei, S., Chen, B., Song, Y., Zhang, T., Yang, W., & Shaman, J. (2020) · Science · doi:10.1126/science.abb3221 · Cited by 3,633
Self-citationTo, K. K.-W., Tsang, O. T.-Y., Leung, W.-S., Tam, A. R., Wu, T.-C., Lung, D. C., Yip, C. C.-Y., Cai, J.-P., Chan, J. M.-C., Chik, T. S.-H., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30196-1 · Cited by 3,066
Self-citationChan, J. F.-W., Kok, K.-H., Zhu, Z., Chu, H., To, K. K.-W., Yuan, S., & Yuen, K.-Y. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1719902 · Cited by 3,059
Antibody responses to SARS-CoV-2 in patients with COVID-19
Long, Q.-X., Liu, B.-Z., Deng, H.-J., Wu, G.-C., Deng, K., Chen, Y.-K., Liao, P., Qiu, J.-F., Lin, Y., Cai, X.-F., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0897-1 · Cited by 2,876
Self-citationCRISPR–Cas12-based detection of SARS-CoV-2
Broughton, J. P., Deng, X., Yu, G., Fasching, C. L., Servellita, V., Singh, J., Miao, X., Streithorst, J. A., Granados, A., Sotomayor-Gonzalez, A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0513-4 · Cited by 2,717
Antibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease 2019
Zhao, J., Yuan, Q., Wang, H., Liu, W., Liao, X., Su, Y., Wang, X., Yuan, J., Li, T., Li, J., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa344 · Cited by 2,607
Feasibility of controlling COVID-19 outbreaks by isolation of cases and contacts
Hellewell, J., Abbott, S., Gimma, A., Bosse, N. I., Jarvis, C. I., Russell, T. W., Munday, J. D., Kucharski, A. J., Edmunds, W. J., Sun, F., et al. (2020) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30074-7 · Cited by 2,550
Characterization of a Novel Coronavirus Associated with Severe Acute Respiratory Syndrome
Rota, P. A., Oberste, M. S., Monroe, S. S., Nix, W. A., Campagnoli, R., Icenogle, J. P., Peñaranda, S., Bankamp, B., Maher, K., Chen, M.-H., et al. (2003) · Science · doi:10.1126/science.1085952 · Cited by 2,474
The Architecture of SARS-CoV-2 Transcriptome
Kim, D., Lee, J.-Y., Yang, J.-S., Kim, J. W., Kim, V. N., & Chang, H. (2020) · Cell · doi:10.1016/j.cell.2020.04.011 · Cited by 2,123
Coronavirus envelope protein: current knowledge
Schoeman, D., & Fielding, B. C. (2019) · Virology Journal · doi:10.1186/s12985-019-1182-0 · Cited by 2,074
Xie, X., Zhong, Z., Zhao, W., Zheng, C., Wang, F., & Liu, J. (2020) · Radiology · doi:10.1148/radiol.2020200343 · Cited by 1,960
Seo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837
Pan, L., Mu, M., Yang, P., Sun, Y., Wang, R., Yan, J., Li, P., Hu, B., Wang, J., Hu, C., et al. (2020) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000000620 · Cited by 1,823
Li, Z., Yi, Y., Luo, X., Xiong, N., Liu, Y., Li, S., Sun, R., Wang, Y., Hu, B., Chen, W., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25727 · Cited by 1,771
Coronaviruses post-SARS: update on replication and pathogenesis
Perlman, S., & Netland, J. (2009) · Nature Reviews Microbiology · doi:10.1038/nrmicro2147 · Cited by 1,764
Okba, N. M. A., Müller, M. A., Li, W., Wang, C., GeurtsvanKessel, C. H., Corman, V. M., Lamers, M. M., Sikkema, R. S., de Bruin, E., Chandler, F. D., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2607.200841 · Cited by 1,614
Profiling Early Humoral Response to Diagnose Novel Coronavirus Disease (COVID-19)
Guo, L., Ren, L., Yang, S., Xiao, M., Chang, D., Yang, F., Dela Cruz, C. S., Wang, Y., Wu, C., Xiao, Y., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa310 · Cited by 1,587
Backer, J. A., Klinkenberg, D., & Wallinga, J. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.5.2000062 · Cited by 1,500
Molecular Diagnosis of a Novel Coronavirus (2019-nCoV) Causing an Outbreak of Pneumonia
Chu, D. K. W., Pan, Y., Cheng, S. M. S., Hui, K. P. Y., Krishnan, P., Liu, Y., Ng, D. Y. M., Wan, C. K. C., Yang, P., Wang, Q., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa029 · Cited by 1,278
Tian, X., Li, C., Huang, A., Xia, S., Lu, S., Shi, Z., Lu, L., Jiang, S., Yang, Z., Wu, Y., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1729069 · Cited by 1,252
Self-citationSaliva or Nasopharyngeal Swab Specimens for Detection of SARS-CoV-2
Wyllie, A. L., Fournier, J., Casanovas-Massana, A., Campbell, M., Tokuyama, M., Vijayakumar, P., Warren, J. L., Geng, B., Muenker, M. C., Moore, A. J., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2016359 · Cited by 1,169
Qiu, G., Gai, Z., Tao, Y., Schmitt, J., Kullak-Ublick, G. A., & Wang, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c02439 · Cited by 1,059
Kimball, A., Hatfield, K. M., Arons, M., James, A., Taylor, J., Spicer, K., Bardossy, A. C., Oakley, L. P., Tanwar, S., Chisty, Z., et al. (2020) · MMWR. Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm6913e1 · Cited by 1,050
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Ultrasensitive and visual detection of SARS-CoV-2 using all-in-one dual CRISPR-Cas12a assay
Ding, X., Yin, K., Li, Z., Lalla, R. V., Ballesteros, E., Sfeir, M. M., & Liu, C. (2020) · Nature Communications · doi:10.1038/s41467-020-18575-6 · Cited by 919
Presymptomatic Transmission of SARS-CoV-2 — Singapore, January 23–March 16, 2020
Wei, W. E., Li, Z., Chiew, C. J., Yong, S. E., Toh, M. P., & Lee, V. J. (2020) · MMWR. Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm6914e1 · Cited by 891
Chan, J. F.-W., Yip, C. C.-Y., To, K. K.-W., Tang, T. H.-C., Wong, S. C.-Y., Leung, K.-H., Fung, A. Y.-F., Ng, A. C.-K., Zou, Z., Tsoi, H.-W., et al. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00310-20 · Cited by 880
Deployment of convalescent plasma for the prevention and treatment of COVID-19
Bloch, E. M., Shoham, S., Casadevall, A., Sachais, B. S., Shaz, B., Winters, J. L., van Buskirk, C., Grossman, B. J., Joyner, M., Henderson, J. P., et al. (2020) · Journal of Clinical Investigation · doi:10.1172/jci138745 · Cited by 799
Laboratory diagnosis of emerging human coronavirus infections – the state of the art
Loeffelholz, M. J., & Tang, Y.-W. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1745095 · Cited by 788
Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges
Farka, Z., Juřík, T., Kovář, D., Trnková, L., & Skládal, P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00037 · Cited by 694
Quantitative Detection and Viral Load Analysis of SARS-CoV-2 in Infected Patients
Yu, F., Yan, L., Wang, N., Yang, S., Wang, L., Tang, Y., Gao, G., Wang, S., Ma, C., Xie, R., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa345 · Cited by 680
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Yu, P., Zhu, J., Zhang, Z., & Han, Y. (2020) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiaa077 · Cited by 659
Saliva is a reliable tool to detect SARS-CoV-2
Azzi, L., Carcano, G., Gianfagna, F., Grossi, P., Gasperina, D. D., Genoni, A., Fasano, M., Sessa, F., Tettamanti, L., Carinci, F., et al. (2020) · Journal of Infection · doi:10.1016/j.jinf.2020.04.005 · Cited by 643
Serial Interval of COVID-19 among Publicly Reported Confirmed Cases
Du, Z., Xu, X., Wu, Y., Wang, L., Cowling, B. J., & Meyers, L. A. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2606.200357 · Cited by 636
Liu, W., Liu, L., Kou, G., Zheng, Y., Ding, Y., Ni, W., Wang, Q., Tan, L., Wu, W., Tang, S., et al. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00461-20 · Cited by 630
Lippi, G., Simundic, A.-M., & Plebani, M. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0285 · Cited by 617
Electrochemical immunosensors – A powerful tool for analytical applications
Felix, F. S., & Angnes, L. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.029 · Cited by 599
A Contemporary View of Coronavirus Transcription
Sawicki, S. G., Sawicki, D. L., & Siddell, S. G. (2007) · Journal of Virology · doi:10.1128/jvi.01358-06 · Cited by 598
Shen, Z., Xiao, Y., Kang, L., Ma, W., Shi, L., Zhang, L., Zhou, Z., Yang, J., Zhong, J., Yang, D., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa203 · Cited by 513 · cited 1×
“DNA sequencing technology can be used to explore novel mutations and the evolution of SARS-CoV-2 isolates (Shen et al., 2020).”
BackgroundYan, C., Cui, J., Huang, L., Du, B., Chen, L., Xue, G., Li, S., Zhang, W., Zhao, L., Sun, Y., et al. (2020) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2020.04.001 · Cited by 507
Huang, X., Aguilar, Z. P., Xu, H., Lai, W., & Xiong, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.032 · Cited by 499
RT‐LAMP for rapid diagnosis of coronavirus SARS‐CoV‐2
Huang, W. E., Lim, B., Hsu, C., Xiong, D., Wu, W., Yu, Y., Jia, H., Wang, Y., Zeng, Y., Ji, M., et al. (2020) · Microbial Biotechnology · doi:10.1111/1751-7915.13586 · Cited by 497
Self-citationKinetics of SARS-CoV-2 specific IgM and IgG responses in COVID-19 patients
Sun, B., Feng, Y., Mo, X., Zheng, P., Wang, Q., Li, P., Peng, P., Liu, X., Chen, Z., Huang, H., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1762515 · Cited by 473
Serology characteristics of SARS-CoV-2 infection after exposure and post-symptom onset
Lou, B., Li, T.-D., Zheng, S.-F., Su, Y.-Y., Li, Z.-Y., Liu, W., Yu, F., Ge, S.-X., Zou, Q.-D., Yuan, Q., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00763-2020 · Cited by 472
Self-citationCai, B., Wang, S., Huang, L., Ning, Y., Zhang, Z., & Zhang, G.-J. (2014) · ACS Nano · doi:10.1021/nn4063424 · Cited by 449
Neuman, B. W., Adair, B. D., Yoshioka, C., Quispe, J. D., Orca, G., Kuhn, P., Milligan, R. A., Yeager, M., & Buchmeier, M. J. (2006) · Journal of Virology · doi:10.1128/jvi.00645-06 · Cited by 438
Nalla, A. K., Casto, A. M., Huang, M.-L. W., Perchetti, G. A., Sampoleo, R., Shrestha, L., Wei, Y., Zhu, H., Jerome, K. R., & Greninger, A. L. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00557-20 · Cited by 434
Ultrasensitive detection of nucleic acids using deformed graphene channel field effect biosensors
Hwang, M. T., Heiranian, M., Kim, Y., You, S., Leem, J., Taqieddin, A., Faramarzi, V., Jing, Y., Park, I., van der Zande, A. M., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15330-9 · Cited by 433
Park, G.-S., Ku, K., Baek, S.-H., Kim, S.-J., Kim, S. I., Kim, B.-T., & Maeng, J.-S. (2020) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2020.03.006 · Cited by 404
Rapid Molecular Detection of SARS-CoV-2 (COVID-19) Virus RNA Using Colorimetric LAMP
Zhang, Y., Odiwuor, N., Xiong, J., Sun, L., Nyaruaba, R. O., Wei, H., & Tanner, N. A. (2020) · medRxiv · doi:10.1101/2020.02.26.20028373 · Cited by 355
Reboud, J., Xu, G., Garrett, A., Adriko, M., Yang, Z., Tukahebwa, E. M., Rowell, C., & Cooper, J. M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812296116 · Cited by 351
Lutz, S., Weber, P., Focke, M., Faltin, B., Hoffmann, J., Müller, C., Mark, D., Roth, G., Munday, P., Armes, N., et al. (2010) · Lab on a Chip · doi:10.1039/b921140c · Cited by 344
Xie, C., Jiang, L., Huang, G., Pu, H., Gong, B., Lin, H., Ma, S., Chen, X., Long, B., Si, G., et al. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.02.050 · Cited by 343
Impedance-Based Detection of Bacteria
Furst, A. L., & Francis, M. B. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00381 · Cited by 321
Baek, Y. H., Um, J., Antigua, K. J. C., Park, J.-H., Kim, Y., Oh, S., Kim, Y.-I., Choi, W.-S., Kim, S. G., Jeong, J. H., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1756698 · Cited by 314
Liang, W.-H., Guan, W.-J., Li, C.-C., Li, Y.-M., Liang, H.-R., Zhao, Y., Liu, X.-Q., Sang, L., Chen, R.-C., Tang, C.-L., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00562-2020 · Cited by 303
Qu, J., Wu, C., Li, X., Zhang, G., Jiang, Z., Li, X., Zhu, Q., & Liu, L. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa489 · Cited by 303
Coronavirus genomic RNA packaging
Masters, P. S. (2019) · Virology · doi:10.1016/j.virol.2019.08.031 · Cited by 261
Kim, K., Kim, M.-J., Kim, D. W., Kim, S. Y., Park, S., & Park, C. B. (2020) · Nature Communications · doi:10.1038/s41467-019-13901-z · Cited by 255
Recent advances in lab-on-a-chip technologies for viral diagnosis
Zhu, H., Fohlerová, Z., Pekárek, J., Basova, E., & Neužil, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112041 · Cited by 251
Pan, Y., Long, L., Zhang, D., Yuan, T., Cui, S., Yang, P., Wang, Q., & Ren, S. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa091 · Cited by 248
Fully Integrated Lab-on-a-Disc for Nucleic Acid Analysis of Food-Borne Pathogens
Kim, T.-H., Park, J., Kim, C.-J., & Cho, Y.-K. (2014) · Analytical Chemistry · doi:10.1021/ac403971h · Cited by 244
Development and evaluation of a rapid CRISPR-based diagnostic for COVID-19
Hou, T., Zeng, W., Yang, M., Chen, W., Ren, L., Ai, J., Wu, J., Liao, Y., Gou, X., Li, Y., et al. (2020) · PLOS Pathogens · doi:10.1371/journal.ppat.1008705 · Cited by 239
Reduced graphene oxide field-effect transistor for label-free femtomolar protein detection
Kim, D.-J., Sohn, I. Y., Jung, J.-H., Yoon, O. J., Lee, N.-E., & Park, J.-S. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.09.040 · Cited by 220
Recent Advances on Electrochemical Biosensing Strategies toward Universal Point‐of‐Care Systems
Dai, Y., & Liu, C. C. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901879 · Cited by 216
Lu, R., Wu, X., Wan, Z., Li, Y., Jin, X., & Zhang, C. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21082826 · Cited by 204
Diagnosis of Acute Respiratory Syndrome Coronavirus 2 Infection by Detection of Nucleocapsid Protein
Diao, B., Wen, K., Chen, J., Liu, Y., Yuan, Z., Han, C., Chen, J., Pan, Y., Chen, L., Dan, Y., et al. (2020) · medRxiv · doi:10.1101/2020.03.07.20032524 · Cited by 195
Self-citationIhling, C., Tänzler, D., Hagemann, S., Kehlen, A., Hüttelmaier, S., Arlt, C., & Sinz, A. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00280 · Cited by 195
Cai, X.-F., Chen, J., li Hu, J., Long, Q.-X., Deng, H.-J., Liu, P., Fan, K., Liao, P., Liu, B.-Z., Wu, G.-C., et al. (2020) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiaa243 · Cited by 186
Self-citationMicrofluidic devices for sample preparation and rapid detection of foodborne pathogens
Kant, K., Shahbazi, M.-A., Dave, V. P., Ngo, T. A., Chidambara, V. A., Than, L. Q., Bang, D. D., & Wolff, A. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.03.002 · Cited by 179
Hu, L.-M., Luo, K., Xia, J., Xu, G.-M., Wu, C.-H., Han, J.-J., Zhang, G.-G., Liu, M., & Lai, W.-H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.030 · Cited by 172
Label-free electrochemical DNA biosensor for zika virus identification
Faria, H. A. M., & Zucolotto, V. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.02.018 · Cited by 165
Lu, R., Wu, X., Wan, Z., Li, Y., Zuo, L., Qin, J., Jin, X., & Zhang, C. (2020) · Virologica Sinica · doi:10.1007/s12250-020-00218-1 · Cited by 165
Rhoads, D. D., Cherian, S., Roman, K. P., Stempak, L. M., Schmotzer, C. L., & Sadri, N. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.00760-20 · Cited by 153
Curti, L. A., Pereyra-Bonnet, F., & Giménez, C. A. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.02.29.971127 · Cited by 150
Bordi, L., Nicastri, E., Scorzolini, L., Di, A., Capobianchi, M. R., Castilletti, C., & Lalle, E. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.8.2000170 · Cited by 145
Oh, J., Yoo, G., Chang, Y. W., Kim, H. J., Jose, J., Kim, E., Pyun, J., & Yoo, K. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.07.004 · Cited by 143
A Scalable, Easy-to-Deploy Protocol for Cas13-Based Detection of SARS-CoV-2 Genetic Material
Rauch, J. N., Valois, E., Solley, S. C., Braig, F., Lach, R. S., Audouard, M., Ponce‐Rojas, J. C., Costello, M. S., Baxter, N. J., Kosik, K. S., et al. (2021) · Journal of Clinical Microbiology · doi:10.1128/jcm.02402-20 · Cited by 139
Nucleocapsid Protein as Early Diagnostic Marker for SARS
Che, X.-Y., Hao, W., Wang, Y., Di, B., Yin, K., Xu, Y.-C., Feng, C.-S., Wan, Z.-Y., Cheng, V. C., & Yuen, K. (2004) · Emerging infectious diseases · doi:10.3201/eid1011.040516 · Cited by 137
Current trends in nanomaterial embedded field effect transistor-based biosensor
Nehra, A., & Singh, K. P. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.030 · Cited by 131
A “sample-in-multiplex-digital-answer-out” chip for fast detection of pathogens
Yin, J., Zou, Z., Hu, Z., Zhang, S., Zhang, F., Wang, B., Lv, S., & Mu, Y. (2020) · Lab on a Chip · doi:10.1039/c9lc01143a · Cited by 130
Kim, J., Kwon, J.-H., Jang, J., Lee, H., Kim, S. K., Hahn, Y. K., Kim, S. K., Lee, K. H., Lee, S., Pyo, H., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.04.047 · Cited by 128
Woo, P. C. Y., Lau, S. K. P., Wong, B. H. L., Tsoi, H.-W., Fung, A. M. Y., Kao, R. Y. T., Chan, K., Peiris, M. J. S., & Yuen, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.7.3054-3058.2005 · Cited by 126
Phillips, E. A., Moehling, T. J., Ejendal, K. F. K., Hoilett, O. S., Byers, K., Basing, L. A., Jankowski, L., Bennett, J. B., Lin, L., Stanciu, L., et al. (2019) · Lab on a Chip · doi:10.1039/c9lc00506d · Cited by 125
Miniaturized devices for point of care molecular detection of HIV
Mauk, M. G., Song, J., Bau, H. H., Gross, R., Bushman, F. D., Collman, R. G., & Liu, C. (2016) · Lab on a Chip · doi:10.1039/c6lc01239f · Cited by 119
Emerging ultrafast nucleic acid amplification technologies for next-generation molecular diagnostics
Lee, S. H., Park, S.-M., Kim, B. N., Kwon, O. S., Rho, W. Y., & Jun, B. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111448 · Cited by 111
A sample-to-answer, portable platform for rapid detection of pathogens with a smartphone interface
Ma, Y.-D., Li, K.-H., Chen, Y.-H., Lee, Y.-M., Chou, S.-T., Lai, Y., Huang, P.-C., Ma, H., & Lee, G. (2019) · Lab on a Chip · doi:10.1039/c9lc00797k · Cited by 109
Self-citationFaye, O., Faye, O., Soropogui, B., Patel, P., Wahed, A. A. E., Loucoubar, C., Fall, G., Kiori, D. E., Magassouba, N., Keita, S., et al. (2015) · Eurosurveillance · doi:10.2807/1560-7917.es.2015.20.44.30053 · Cited by 108
He, H., Li, R., Chen, Y., Pan, P., Tong, W., Dong, X., Chen, Y., & Yu, D. (2017) · Scientific Reports · doi:10.1038/srep45199 · Cited by 105
Self-citationPurification of nucleic acids using isotachophoresis
Rogacs, A., Marshall, L. A., & Santiago, J. G. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.027 · Cited by 101
Immunosensor-based label-free and multiplex detection of influenza viruses: State of the art
Zhang, H., & Miller, B. L. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111476 · Cited by 100
Yip, C. C., Ho, C.-C., Chan, J. F., To, K. K., Chan, H. S., Wong, S. C. Y., Leung, K., Fung, A. Y.-F., Ng, A. C., Zou, Z., et al. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21072574 · Cited by 99
Electronic Detection of MicroRNA at Attomolar Level with High Specificity
Ramnani, P., Gao, Y., Özsöz, M., & Mulchandani, A. (2013) · Analytical Chemistry · doi:10.1021/ac4018346 · Cited by 98
Wahed, A. A. E., Patel, P., Heidenreich, D., Hufert, F. T., & Weidmann, M. (2013) · PLoS Currents · doi:10.1371/currents.outbreaks.62df1c7c75ffc96cd59034531e2e8364 · Cited by 97
Long-Term Persistence of IgG Antibodies in SARS-CoV Infected Healthcare WorkersPreprint
Guo, X., Guo, Z., Duan, C., Chen, Z., Wang, G., Lu, Y., Li, M., & Lu, J. (2020) · medRxiv · doi:10.1101/2020.02.12.20021386 · Cited by 92
Self-citationSteinmetz, M., Lima, D., Viana, A. G., Fujiwara, S. T., Pessôa, C. A., Etto, R. M., & Wohnrath, K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111351 · Cited by 91
Biosensor-based selective detection of Zika virus specific antibodies in infected individuals
Cabral‐Miranda, G., Cardoso, A. R. A., Ferreira, L. C. D. S., Sales, M. G. F., & Bachmann, M. F. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.04.058 · Cited by 84
Ai, J.-W., Zhang, Y., Zhang, H.-C., Xu, T., & Zhang, W. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1738905 · Cited by 84
Okba, N. M. A., Raj, V. S., Widjaja, I., GeurtsvanKessel, C. H., de Bruin, E., Chandler, F. D., Park, W. B., Kim, N. J., Farag, E., Al-Hajri, M., et al. (2019) · Emerging infectious diseases · doi:10.3201/eid2510.190051 · Cited by 79
Zhang, J., Zhang, X., Liu, J., Ban, Y., Li, N., Wu, Y., Liu, Y., Ye, R., Liu, J., Li, X., et al. (2020) · International Immunopharmacology · doi:10.1016/j.intimp.2020.106861 · Cited by 72
Near-Infrared Lanthanide-Doped Nanoparticles for a Low Interference Lateral Flow Immunoassay Test
Liu, Q., Cheng, S., Chen, R., Ke, J., Liu, Y., Li, Y., Feng, W., & Li, F. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22449 · Cited by 70
SARS Coronavirus Detection Methods
Lau, S. K. P., Che, X.-Y., Woo, P. C. Y., Wong, B. H. L., Cheng, V. C., Woo, G. K. S., Hung, I. F., Poon, R. W., Chan, K., Peiris, M. J. S., et al. (2005) · Emerging infectious diseases · doi:10.3201/eid1107.041045 · Cited by 69
Jin, C. E., Koo, B., Lee, T. Y., Han, K., Lim, S., Park, I. J., & Shin, Y. M. (2018) · Advanced Science · doi:10.1002/advs.201800614 · Cited by 67
Ouyang, W., & Han, J. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1904513116 · Cited by 64
Hu, C., Kalsi, S., Zeimpekis, I., Sun, K., Ashburn, P., Turner, C., Sutton, J. M., & Morgan, H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.016 · Cited by 63
Connelly, J. T., Kondapalli, S., Skoupi, M., Parker, J. S. L., Kirby, B. J., & Baeumner, A. J. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5381-9 · Cited by 62
Field‐Effect Biosensors for On‐Site Detection: Recent Advances and Promising Targets
Choi, J., Seong, T. W., Jeun, M., & Lee, K. H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700796 · Cited by 61
Jayakumar, K., Camarada, M. B., Venkatraman, D., Ju, H., Dey, R. S., & Wen, Y. (2017) · Nanoscale · doi:10.1039/c7nr06952a · Cited by 56
Xuan, C., Dong, T., Wei, X., Yang, Z., Pires, N. M. M., Ren, J., & Jiang, Z. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111453 · Cited by 54
Yang, H., Chen, Z., Cao, X., Li, Z., Stavrakis, S., Choo, J., deMello, A. J., Howes, P. D., & He, N. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1335-9 · Cited by 48
Son, M., Kim, D., Park, K. S., Hong, S., & Park, T. H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.029 · Cited by 45
Carbon Nanotube Thin Film Biosensors for Sensitive and Reproducible Whole Virus Detection
Mandal, H. S., Su, Z., Ward, A. R., & Tang, X. S. (2012) · Theranostics · doi:10.7150/thno.3726 · Cited by 44
Maity, A., Sui, X., Jin, B., Pu, H., Bottum, K. J., Huang, X., Chang, J., Zhou, G., Lu, G., & Chen, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03226 · Cited by 43
Generation of antibodies against COVID-19 virus for development of diagnostic toolsPreprint
Li, M., Jin, R., Peng, Y., Wang, C., Ren, W., Lv, F., Gong, S., Fang, F., Wang, Q., Li, J., et al. (2020) · medRxiv · doi:10.1101/2020.02.20.20025999 · Cited by 36
Ouyang, W., & Han, J. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201915788 · Cited by 34
Qu, Y., Marshall, L. A., & Santiago, J. G. (2014) · Analytical Chemistry · doi:10.1021/ac501299a · Cited by 30
Woo, P. C. Y., Lau, S. K. P., Chen, Y., Wong, E. Y. M., Chan, K., Chen, H., Zhang, L., Xia, N., & Yuen, K. (2018) · Emerging Microbes & Infections · doi:10.1038/s41426-017-0016-7 · Cited by 29
Self-citationKim, Y.-H., Abafogi, A. T., Tran, B. M., Kim, J., Lee, J., Chen, Z., Bae, P. K., Park, K., Shin, Y., van Noort, D., et al. (2020) · Micromachines · doi:10.3390/mi11020203 · Cited by 29
Jin, C. E., Lee, T. Y., Koo, B., Choi, K., Chang, S., Park, S. Y., Kim, J. Y., Kim, S., & Shin, Y. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01193 · Cited by 20
Electrical Lysis and RNA Extraction from Single Cells Fixed by Dithiobis(succinimidyl propionate)
Parimalam, S. S., Oguchi, Y., Abdelmoez, M. N., Tsuchida, A., Ozaki, Y., Yokokawa, R., Kotera, H., & Shintaku, H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02338 · Cited by 18
Lyu, L., Feng, R., Zhang, M., Gong, Q., Liao, Y., Zhou, Y., Guo, X., Su, B., Dorsett, Y., & Chen, L. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.04.16.043224 · Cited by 6
Self-citation
Cited by
Lessons learned 1 year after SARS-CoV-2 emergence leading to COVID-19 pandemic
To, K. K.-W., Sridhar, S., Chiu, K. H.-Y., Hung, D. L.-L., Li, X., Hung, I. F.-N., Tam, A. R., Chung, T. W.-H., Chan, J. F.-W., Zhang, A. J.-X., et al. (2021) · Emerging Microbes & Infections · doi:10.1080/22221751.2021.1898291 · Cited by 344
Two-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 303
Pang, B., Xu, J., Liu, Y., Peng, H., Feng, W., Cao, Y., Wu, J., Xiao, H., Pabbaraju, K., Tipples, G., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04047 · Cited by 265
Emerging Telemedicine Tools for Remote COVID-19 Diagnosis, Monitoring, and Management
Lukas, H., Xu, C., Yu, Y., & Gao, W. (2020) · ACS Nano · doi:10.1021/acsnano.0c08494 · Cited by 265
Narita, F., Wang, Z., Kurita, H., Li, Z., Shi, Y., Jia, Y., & Soutis, C. (2021) · Advanced Materials · doi:10.1002/adma.202005448 · Cited by 263
Metadata
- Authors
- Ji, T., Liu, Z., Wang, G., Guo, X., Akbar khan, S., Lai, C., Chen, H., Huang, S., Xia, S., Chen, B., Jia, H., Chen, Y., & Zhou, Q.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 166
- Pages
- 112455
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3044223324
- Cited by
- 383
- References
- 128
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.