CoChat

tDCS changes in motor excitability are specific to orientation of current flow

Open access
Rawji, Vishal, Ciocca, Matteo, Zacharia, André, Soares, David, Truong, Dennis, Bikson, Marom, Rothwell, John, Bestmann, Sven · 2018 · Brain Stimulation
Cited by 147

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Abstract Measurements and models of current flow in the brain during transcranial Direct Current Stimulation (tDCS) indicate stimulation of regions in-between electrodes. Moreover, the cephalic cortex result in local fluctuations in current flow intensity and direction, and animal studies suggest current flow direction relative to cortical columns determines response to tDCS. Here we test this idea by measuring changes in cortico-spinal excitability by Transcranial Magnetic Stimulation Motor Evoked Potentials (TMS-MEP), following tDCS applied with electrodes aligned orthogonal (across) or parallel to M1 in the central sulcus. Current flow models predicted that the orthogonal electrode montage produces consistently oriented current across the hand region of M1 that flows along cortical columns, while the parallel electrode montage produces none-uniform current directions across the M1 cortical surface. We find that orthogonal, but not parallel, orientated tDCS modulates TMS-MEPs. We also show modulation is sensitive to the orientation of the TMS coil (PA or AP), which is through to select different afferent pathways to M1. Our results are consistent with tDCS producing directionally specific neuromodulation in brain regions in-between electrodes, but shows nuanced changes in excitability that are presumably current direction relative to column and axon pathway specific. We suggest that the direction of current flow through cortical target regions should be considered for targeting and dose-control of tDCS. Highlights Direction of current flow is important for tDCS after-effects. tDCS modulates excitability between two electrodes. tDCS differentially modulates PA and AP inputs into M1. Abbreviations PA postero-anterior AP antero-posterior ML medio-lateral tDCS transcranial direct current stimulation MEP motor evoked potential M1 primary motor cortex TMS transcranial magnetic stimulation; AP-TMS-MEPs motor evoked potentials elicited with anterior-posterior directed TMS; PA-TMS-MEPs motor evoked potentials elicited with posterior-anterior directed TMS Funding This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.brs.2017.11.001

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 147

Metadata

Authors
Rawji, V., Ciocca, M., Zacharia, A., Soares, D., Truong, D., Bikson, M., Rothwell, J., & Bestmann, S.
Venue
Brain Stimulation
Publisher
Elsevier BV
Published
2018-03
Volume
11
Issue
2
Pages
289-298
ISSN
  • 1876-4754 (ISSN-L)
  • 1935-861X
OpenAlex
W2952991391
Cited by
147
References
11
FWCI
6.04
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.