Quasi-Static Ultrasound Elastography
Open accessThe DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Abstract
Elastography is a new imaging modality where elastic tissue parameters related to the structural organization of normal and pathological tissues are imaged. Basic principles underlying the quasi-static elastography concept and principles are addressed. The rationale for elastographic imaging is reinforced using data on elastic properties of normal and abnormal soft tissues. The several orders of magnitude difference between the elastic modulus of normal and abnormal tissues which is the primary contrast mechanism in elastographic imaging underlines the probability of success with this imaging modality. Recent advances enabling the clinical practice of elastographic imaging in real-time on clinical ultrasound systems is also discussed. In quasi-static elastography, radiofrequency echo signals acquired before and after a small (about 1%) of applied deformation are correlated to estimate tissue displacements. Local tissue displacement vector estimates between small segments of the pre- and post-deformation signals are estimated and the corresponding strain distribution imaged. Elastographic imaging techniques are based on the hypothesis that soft tissues deform more than stiffer tissue, and these differences can be quantified in images of the tissue strain tensor or the Young’s modulus. Clinical applications of quasi-static elastography have mushroomed over the last decade, with the most commonly imaged areas being the breast, prostate, thyroid, cardiac, treatment monitoring of ablation procedures and vascular imaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
LANDAU, L. D., & LIFSHITZ, E. M. (1951) · Cited by 5,903
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727 · cited 1×
“This is in contrast to dynamic methods for tissue elasticity measurement that utilize variations in the velocity of the shear waves generated in tissue to obtain modulus distributions [22,98,99].”
ResultElastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703 · cited 1×
“For example, breast scirrhous carcinomas on palpation are felt to be extremely hard nodules [31,32], while liver tissue with cirrhosis is also known to be significantly stiffer than normal healthy liver tissue [33].”
BackgroundElastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940 · cited 5×
“A second parameter referred to as the ‘size ratio’ derived from the ratio of the lesion dimensions derived from the strain and B-mode images was then proposed to differentiate between benign fibroadenomas from malignant tumors[13,15].”
BackgroundMethodResultInfluentialSuffoletto, M. S., Dohi, K., Cannesson, M., Saba, S., & Gorcsan, J. (2006) · Circulation · doi:10.1161/circulationaha.105.571455 · Cited by 815
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationGlobal longitudinal strain: a novel index of left ventricular systolic function
Reisner, S. A., Lysyansky, P., Agmon, Y., Mutlak, D., Lessick, J., & Friedman, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.02.011 · Cited by 735
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699 · cited 3×
“Displacement estimates from the multiple small deformations have been accumulated [8,9], averaged or compounded [6– 9] to improve strain and modulus images.”
BackgroundMethodQuantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Palmeri, M. L., Wang, M. H., Dahl, J. J., Frinkley, K. D., & Nightingale, K. R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.009 · Cited by 683 · cited 1×
“This is in contrast to dynamic methods for tissue elasticity measurement that utilize variations in the velocity of the shear waves generated in tissue to obtain modulus distributions [22,98,99].”
ResultSelected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671
OCT elastography: imaging microscopic deformation and strain of tissue
Schmitt, J. M. (1998) · Optics Express · doi:10.1364/oe.3.000199 · Cited by 620
A fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
Ultrasonic imaging of internal vibration of soft tissue under forced vibration
Yamakoshi, Y., Sato, J., & Sato, T. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.46969 · Cited by 474
Elastic modulus measurements of human liver and correlation with pathology
Yeh, W.-C., Li, P.-C., Jeng, Y.-M., Hsu, H.-C., Kuo, P.-L., Li, M.-L., Yang, P.-M., & Lee, P. H. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00489-1 · Cited by 458 · cited 2×
“[108], show that liver tissue stiffness increase with cirrhosis.”
BackgroundKonofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast In Vivo
Cespedes, I. (1993) · Ultrasonic Imaging · doi:10.1006/uimg.1993.1007 · Cited by 414
In vivo real-time freehand palpation imaging
Hall, T. J., Zhu, Y., & Spalding, C. S. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00733-0 · Cited by 394 · cited 4×
“[15], described an approach that coupled real-strain strain imaging (7 frames per second) and visualization with freehand deformations termed ‘palpation imaging’.”
BackgroundMethodInfluentialAn overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Krouskop, T. A., Dougherty, D. R., & Vinson, F. S. (1987) · PubMed · Cited by 362
A theoretical framework for performance characterization of elastography: the strain filter
Varghese, T., & Ophir, J. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.585212 · Cited by 338
Self-citationImaging and Estimation of Tissue Elasticity by Ultrasound
Garra, B. S. (2007) · Ultrasound Quarterly · doi:10.1097/ruq.0b013e31815b7ed6 · Cited by 331
Tissue elasticity reconstruction using linear perturbation method
Kallel, F., & Bertrand, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500139 · Cited by 329 · cited 5×
“[38] utilized a Newton-Raphson algorithm to find the modulus distribution that provides the best reproduction of the estimated axial displacement field using Tikhonov regularization to achieve convergence in 8–10 steps.”
BackgroundMethodInfluentialYoung's modulus measurements of soft tissues with application to elasticity imaging
Chen, E. J., Novakofski, J., Jenkins, W. K., & O'Brien, W. D. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.484478 · Cited by 312
Pesavento, A., Perrey, C., Krueger, M., & Ermert, H. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.796111 · Cited by 296
Differentiating Benign from Malignant Solid Breast Masses with US Strain Imaging
Burnside, E. S., Hall, T. J., Sommer, A. M., Hesley, G. K., Sisney, G. A., Svensson, W. E., Fine, J. P., Jiang, J., & Hangiandreou, N. J. (2007) · Radiology · doi:10.1148/radiol.2452061805 · Cited by 296
Measuring the elastic modulus of ex vivo small tissue samples
Samani, A., Bishop, J., Luginbuhl, C., & Plewes, D. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/310 · Cited by 295
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287 · cited 1×
“Displacement estimates from the multiple small deformations have been accumulated [8,9], averaged or compounded [6– 9] to improve strain and modulus images.”
BackgroundTime-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Myocardial elastography—a feasibility study in vivo
Konofagou, E. E., D’hooge, J., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00488-x · Cited by 264 · cited 2×
“Cardiac-elastography or myocardial strain imaging where the strain distribution is imaged over the entire contraction and relaxation of the heart (cardiac cycle) [36,37] is another clinical application that utilizes physiological stimuli.”
BackgroundMethodLung tissue viscoelasticity: a mathematical framework and its molecular basis
Suki, B., Barabási, A.-Ĺ., & Lutchen, K. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2749 · Cited by 264
Evaluation of an iterative reconstruction method for quantitative elastography
Doyley, M. M., Meaney, P. M., & Bamber, J. C. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/309 · Cited by 251
2-D companding for noise reduction in strain imaging
Chaturvedi, P., Insana, M. F., & Hall, T. J. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.646923 · Cited by 231 · cited 1×
“Displacement estimation in areas where the tissue continuity assumption does not hold namely for vascular tissue have also been developed [65,66], by processing data using a coarse to a fine approach in multiple estimation stages [48,50,51].”
MethodMaterial characterization of the brainstem from oscillatory shear tests
Arbogast, K. B., & Margulies, S. S. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00068-2 · Cited by 225
Becker, M., Bilke, E., Kühl, H., Katoh, M., Kramann, R., Franke, A., Bücker, A., Hanrath, P., & Hoffmann, R. (2006) · Heart · doi:10.1136/hrt.2005.077107 · Cited by 222
Fundamental limitations in passive time-delay estimation--Part II: Wide-band systems
Weinstein, E., & Weiss, A. (1984) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1984.1164429 · Cited by 222
Nonlinear viscoelastic effects in oscillatory shear deformation of brain tissue
Darvish, K. K., & Crandall, J. R. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00101-1 · Cited by 198
Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms
de Korte, C. L., Céspedes, E. I., van der Steen, A. F. W., et al. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00004-5 · Cited by 191 · cited 1×
“Intravascular ultrasound (IVUS) based strain imaging of coronary arteries using pulsations introduced due to cardiac activity has been widely described in the literature and is probably the most common clinical application involving physiological stimuli[9,18,45,92,93].”
BackgroundIntravascular Ultrasound Elastography in Human Arteries: Initial Experience In Vitro
de Korte, C. L., van der Steen, A. F. W., Céspedes, E. I., & Pasterkamp, G. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00280-9 · Cited by 190 · cited 1×
“Intravascular ultrasound (IVUS) based strain imaging of coronary arteries using pulsations introduced due to cardiac activity has been widely described in the literature and is probably the most common clinical application involving physiological stimuli[9,18,45,92,93].”
BackgroundMeasurement of soft tissue motion using correlation between A-scans
Dickinson, R. J., & Hill, C. R. (1982) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(82)90032-1 · Cited by 186 · cited 1×
“The success of elastographic imaging is predicated primarily on the several orders of the Young’s modulus contrast that exist between normal and abnormal tissue types [1,2,6].”
BackgroundUltrasound Elastography Based on Multiscale Estimations of Regularized Displacement Fields
Pellot-Barakat, C. J. M., Frouin, F., Insana, M. F., & Herment, A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.822825 · Cited by 184 · cited 1×
“Displacement estimation in areas where the tissue continuity assumption does not hold namely for vascular tissue have also been developed [65,66], by processing data using a coarse to a fine approach in multiple estimation stages [48,50,51].”
MethodCharacterization of plaque components and vulnerability with intravascular ultrasound elastography
Korte, C. L. D., Steen, A. F. W. V. D., Céspedes, E. I., Pasterkamp, G., Carlier, S. G., Mastik, F., Schoneveld, A. H., Serruys, P. W., & Bom, N. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/305 · Cited by 175
Breast Lesions: Evaluation with US Strain Imaging–Clinical Experience of Multiple Observers
Regner, D. M., Hesley, G. K., Hangiandreou, N. J., Morton, M. J., Nordland, M. R., Meixner, D. D., Hall, T. J., Farrell, M. A., Mandrekar, J. N., Harmsen, W. S., et al. (2006) · Radiology · doi:10.1148/radiol.2381041336 · Cited by 175
Ultrasonic measurement of small displacements and deformations of tissue
Wilson, L. (1982) · Ultrasonic Imaging · doi:10.1016/0161-7346(82)90006-2 · Cited by 172 · cited 1×
“The success of elastographic imaging is predicated primarily on the several orders of the Young’s modulus contrast that exist between normal and abnormal tissue types [1,2,6].”
BackgroundQuantitative elasticity imaging: what can and cannot be inferred from strain images
Barbone, P. E., & Bamber, J. C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/310 · Cited by 171 · cited 10×
“Bamber JC, Bush NL. Freehand elasticity imaging using speckle decorrelation rate.”
BackgroundMethodInfluentialVarghese, T., Zagzebski, J. A., & Lee, F. T. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00656-7 · Cited by 169 · cited 3×
“An interesting offshoot is the utilization of the radiofrequency or microwave electrode itself to introduce the quasi-static deformation for both strain [88] and modulus [91] imaging.”
BackgroundMethodSelf-citationVisualizing tissue compliance with MR imaging
Plewes, D. B., Betty, I., Urchuk, S. N., & Soutar, I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050620 · Cited by 166
Ophir, J., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., Righetti, R., & Varghese, T. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00156-3 · Cited by 166
Self-citationReal-Time Sonoelastography of the Cervix: Tissue Elasticity of the Normal and Abnormal Cervix
Thomas, A., Kümmel, S., Gemeinhardt, O., & Fischer, T. (2007) · Academic Radiology · doi:10.1016/j.acra.2006.11.010 · Cited by 166
Linear and nonlinear elasticity imaging of soft tissuein vivo: demonstration of feasibility
Oberai, A. A., Gokhale, N. H., Goenezen, S., Barbone, P. E., Hall, T. J., Sommer, A. M., & Jiang, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/006 · Cited by 162 · cited 1×
“Strain [13,15,75,76,128–130] and modulus [40] imaging of masses in the breast have been widely reported in the literature.”
BackgroundEffects of collagenase and elastase on the mechanical properties of lung tissue strips
Yuan, H., Kononov, S., Cavalcante, F. S. A., Lutchen, K. R., Ingenito, E. P., & Suki, B. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.3 · Cited by 161
Fundamental mechanical limitations on the visualization of elasticity contrast in elastography
Ponnekanti, H., Ophir, J., Huang, Y., & Céspedes, I. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00136-2 · Cited by 156
Probing the dynamics of tissue at low frequencies with the radiation force of ultrasound
Fatemi, M., & Greenleaf, J. F. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/304 · Cited by 155
An analysis of elastographic contrast-to-noise ratio
Varghese, T., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00047-7 · Cited by 154
Self-citationFundamental limitations on the contrast-transfer efficiency in elastography: An analytic study
Kallel, F., Bertrand, M., & Ophir, J. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02079-9 · Cited by 153
AAPM/RSNA Physics Tutorial for Residents: Topics in US
Hall, T. J. (2003) · Radiographics · doi:10.1148/rg.236035163 · Cited by 152
Ribbers, H., Lopata, R. G. P., Holewijn, S., Pasterkamp, G., Blankensteijn, J. D., & de Korte, C. L. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.09.009 · Cited by 149
Cédric Schmitt, A., Soulez, G., Maurice, R. L., Giroux, M.-F., & Cloutier, G. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.05.020 · Cited by 146
A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue
Han, L., Noble, J. A., & Burcher, M. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00776-7 · Cited by 146
Axial resolution in elastography
Righetti, R., Ophir, J., & Ktonas, P. Y. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00495-1 · Cited by 143
A unified view of imaging the elastic properties of tissue
Parker, K. J., Taylor, L. S., Gracewski, S. M., & Rubens, D. J. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1880772 · Cited by 142
Mechanical Imaging of the Breast
Egorov, V., & Sarvazyan, A. P. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.922192 · Cited by 136 · cited 1×
“Techniques to obtain the local stress distribution patterns using force sensor arrays during tissue deformation have been reported [81].”
BackgroundPoroelastography: imaging the poroelastic properties of tissues
Konofagou, E. E., Harrigan, T. P., Ophir, J., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00433-1 · Cited by 135 · cited 2×
“Quasi-static elastography has also been utilized for imaging the poroelastic properties of tissue that accumulate fluid, for example for evaluating lymphedema, which involves an abnormal interstitial accumulation of lymphatic fluid causing tissue swelling [39,77,151].”
BackgroundMethod3-D Correlation-Based Speckle Tracking
Chen, X., Xie, H., Erkamp, R., Kim, K., Jia, C., Rubin, J. M., & O’Donnell, M. (2005) · Ultrasonic Imaging · doi:10.1177/016173460502700102 · Cited by 131
Direct strain estimation in elastography using spectral cross-correlation
Varghese, T., Konofagou, E. E., Ophir, J., Alam, S. K., & Bilgen, M. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00316-1 · Cited by 127 · cited 1×
“Estimators that do not utilize phase information that include optical flow-based speckle tracking [12], analysis of envelope or B-mode signals [57], power spectral methods[45,58,59], and methods like sum amplitude or sum-squared difference that mimic cross-correlation [60,61].”
MethodSelf-citationMechanical properties of the human uterine cervix: An in vivo study
Mazza, E., Nava, A., Bauer, M., Winter, R., Bajka, M., & Holzapfel, G. A. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.06.001 · Cited by 117
Tradeoffs in Elastographic Imaging
Varghese, T., Ophir, J., Konofagou, E. E., Kallel, F., & Righetti, R. (2001) · Ultrasonic Imaging · doi:10.1177/016173460102300402 · Cited by 111
Self-citationBreast tumor classification using axial shear strain elastography: a feasibility study
Thitaikumar, A., Mobbs, L. M., Kraemer-Chant, C. M., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/022 · Cited by 103 · cited 3×
“Another parameter utilized in the differentiation is related to lesion mobility; since cancers are firmly attached to surrounding tissue, when compared to fibroadenomas that are more mobile and hence slip during the applied deformation [75,76].”
BackgroundMethodMagnetic‐resonance imaging techniques for detection of elasticity variation
Fowlkes, J. B., Emelianov, S., Pipe, J. G., Skovoroda, A. R., Carson, P. L., Adler, R. S., & Sarvazyan, A. P. (1995) · Medical Physics · doi:10.1118/1.597633 · Cited by 97
Elastography: A systems approach
Ophir, J., Kallel, F., Varghese, T., Bertrand, M., C�spedes, I., & Ponnekanti, H. (1997) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(1997)8:1<89::aid-ima11>3.0.co;2-g · Cited by 90
Self-citationSonographic Elasticity Imaging of Acute and Chronic Deep Venous Thrombosis in Humans
Rubin, J. M., Xie, H., Kim, K., Weitzel, W. F., Emelianov, S., Aglyamov, S. R., Wakefield, T. W., Urquhart, A. G., & O’Donnell, M. (2006) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2006.25.9.1179 · Cited by 89
Identifying the mechanical properties of tissue by ultrasound strain imaging
Turgay, E., Salcudean, S. E., & Rohling, R. N. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.09.015 · Cited by 87 · cited 1×
“Both wellcontrolled [24,34] and freehand-based [15] approaches have been described.”
Lateral resolution in elastography
Righetti, R., Srinivasan, S., & Ophir, J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00028-0 · Cited by 83
Trade-offs between the axial resolution and the signal-to-noise ratio in elastography
Srinivasan, S. S., Righetti, R., & Ophir, J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00037-1 · Cited by 81
New real-time strain imaging concepts using diagnostic ultrasound
Pesavento, A., Lorenz, A., Siebers, S., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/302 · Cited by 81 · cited 3×
“Both wellcontrolled [24,34] and freehand-based [15] approaches have been described.”
BackgroundMethodMultiresolution imaging in elastography
Varghese, T., Bilgen, M., & Ophir, J. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.646912 · Cited by 80 · cited 2×
“Tradeoffs in the displacement vector and strain tensor estimation process from the noisy preand post-deformed ultrasound radiofrequency signals has been described statistically using the ‘Strain Filter’ concept [11,47,118].”
BackgroundMethodSelf-citationUltrasonic biomechanical strain gauge based on speckle tracking
Bertrand, M., Meunier, J., Doucet, M., & Ferland, G. (2003) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1989.67110 · Cited by 77 · cited 1×
“Estimators that do not utilize phase information that include optical flow-based speckle tracking [12], analysis of envelope or B-mode signals [57], power spectral methods[45,58,59], and methods like sum amplitude or sum-squared difference that mimic cross-correlation [60,61].”
MethodRighetti, R., Garra, B. S., Mobbs, L. M., Kraemer-Chant, C. M., Jonathan Ophir, A., & Krouskop, T. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/013 · Cited by 74 · cited 3×
“Quasi-static elastography has also been utilized for imaging the poroelastic properties of tissue that accumulate fluid, for example for evaluating lymphedema, which involves an abnormal interstitial accumulation of lymphatic fluid causing tissue swelling [39,77,151].”
BackgroundMethodInternal deformation of a uniform elastic solid by acoustic radiation force
Walker, W. F. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426854 · Cited by 72
Acoustic shear-wave imaging using echo ultrasound compared to magnetic resonance elastography
Dutt, V., Kinnick, R. R., Muthupillai, R., Oliphant, T. E., Ehman, R. L., & Greenleaf, J. F. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00166-0 · Cited by 70
An Inverse Method for Imaging the Local Elasticity of Atherosclerotic Coronary Plaques
Baldewsing, R. A., Danilouchkine, M. G., Mastik, F., Schaar, J. A., Serruys, P. W. J. C., & van der Steen, A. F. W. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.907980 · Cited by 70 · cited 3×
“Investigators have utilized physiological stimuli to obtain both forward [35–37] and inverse problem [97] solutions for elastography.”
BackgroundMethodInfluentialA parallelizable real-time motion tracking algorithm with applications to ultrasonic strain imaging
Jiang, J., & Hall, T. J. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/13/008 · Cited by 69
Characterization of Elastographic Noise Using the Envelope of Echo Signals
Varghese, T., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00008-8 · Cited by 68 · cited 1×
“Estimators that do not utilize phase information that include optical flow-based speckle tracking [12], analysis of envelope or B-mode signals [57], power spectral methods[45,58,59], and methods like sum amplitude or sum-squared difference that mimic cross-correlation [60,61].”
MethodSelf-citationPower spectral strain estimators in elastography
Konofagou, E. E., Varghese, T., Ophir, J., & Alam, S. K. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00061-7 · Cited by 66 · cited 1×
“Estimators that do not utilize phase information that include optical flow-based speckle tracking [12], analysis of envelope or B-mode signals [57], power spectral methods[45,58,59], and methods like sum amplitude or sum-squared difference that mimic cross-correlation [60,61].”
MethodSelf-citationElastographic axial resolution criteria: an experimental study
Alam, S. K., Ophir, J., & Varghese, T. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.818775 · Cited by 57
Self-citationFreehand Elasticity Imaging Using Speckle Decorrelation Rate
Bamber, J. C., & Bush, N. L. (1996) · Acoustical imaging · doi:10.1007/978-1-4419-8772-3_45 · Cited by 57
Normal and shear strain estimation using beam steering on linear-array transducers
Rao, M., Chen, Q., Shi, H., Varghese, T., Madsen, E. L., Zagzebski, J. A., & Wilson, T. A. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.07.027 · Cited by 54 · cited 2×
“[72] to estimate components of the displacement vector, which was later adapted to linear array transducers with electronic beam steering [68].”
BackgroundSelf-citationJiang, J., Varghese, T., Brace, C. L., Madsen, E. L., Hall, T. J., Bharat, S., Hobson, M. A., Zagzebski, J. A., & Lee, F. T. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2015355 · Cited by 54 · cited 4×
“An interesting offshoot is the utilization of the radiofrequency or microwave electrode itself to introduce the quasi-static deformation for both strain [88] and modulus [91] imaging.”
BackgroundMethodInfluentialSelf-citationNoise Reduction Using Spatial-Angular Compounding for Elastography
Techavipoo, U., Chen, Q., Varghese, T., Zagzebski, J. A., & Madsen, E. L. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1320824 · Cited by 53
Self-citationde Korte, C. L., Schaar, J. A., Mastik, F., et al. (2003) · Journal of Interventional Cardiology · doi:10.1034/j.1600-0854.2003.8049.x · Cited by 34
3D prostate elastography: algorithm, simulations and experiments
Patil, A. V., Garson, C. D., & Hossack, J. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/019 · Cited by 34
Spatial‐angular compounding for elastography using beam steering on linear array transducers
Rao, M., Chen, Q., Shi, H., & Varghese, T. (2006) · Medical Physics · doi:10.1118/1.2168429 · Cited by 34
Self-citationLocal Elasticity Imaging of Vulnerable Atherosclerotic Coronary Plaques
Baldewsing, R. A., Schaar, J. A., Mastik, F., et al. (2006) · KARGER eBooks · doi:10.1159/000096719 · Cited by 33
In Vitro Uterine Strain Imaging: Preliminary Results
Hobson, M. A., Kiss, M. Z., Varghese, T., Sommer, A. M., Kliewer, M. A., Zagzebski, J. A., Hall, T. J., Harter, J. M., Hartenbach, E. M., & Madsen, E. L. (2007) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2007.26.7.899 · Cited by 32
Self-citationComparison of shift estimation strategies in spectral elastography
Hoyt, K., Forsberg, F., & Ophir, J. (2005) · Ultrasonics · doi:10.1016/j.ultras.2005.08.006 · Cited by 30 · cited 1×
“Estimators that do not utilize phase information that include optical flow-based speckle tracking [12], analysis of envelope or B-mode signals [57], power spectral methods[45,58,59], and methods like sum amplitude or sum-squared difference that mimic cross-correlation [60,61].”
MethodShear strain imaging using shear deformations
Rao, M., Varghese, T., & Madsen, E. L. (2008) · Medical Physics · doi:10.1118/1.2825621 · Cited by 20 · cited 1×
“The normal strain tensor components are also essential in the estimation of other important parameters such as the shear strains [68,73,74] and lateral to axial strain ratios (equivalent to the Poisson’s ratio under specific conditions) [39].”
BackgroundSelf-citation
Cited by
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Tang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14552 · Cited by 216
“, stress) [6].”
Metadata
- Authors
- Varghese, T.
- Venue
- Ultrasound Clinics
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 4
- Issue
- 3
- Pages
- 323-338
- ISSN
- 1556-858X (ISSN-L)
- OpenAlex
- W2168833460
- Cited by
- 169
- References
- 101
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.