Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Until now, high-sensitivity cardiac troponin (hs-cTn) assays were mainly developed for large central laboratory platforms. OBJECTIVES: This study aimed to assess the clinical performance of a point-of-care (POC)-hs-cTnI assay in patients with suspected myocardial infarction (MI). METHODS: This study enrolled patients presenting to the emergency department with symptoms suggestive of MI. Two cardiologists centrally adjudicated the final diagnosis using all clinical data including cardiac imaging. The primary objective was to directly compare diagnostic accuracy of POC-hs-cTnI-TriageTrue versus best-validated central laboratory assays. Secondary objectives included the derivation and validation of a POC-hs-cTnI-TriageTrue-specific 0/1-h algorithm. RESULTS: MI was the adjudicated final diagnosis in 178 of 1,261 patients (14%). The area under the curve (AUC) for POC-hs-cTnI-TriageTrue at presentation was 0.95 (95% confidence interval [CI]: 0.93 to 0.96) and was at least comparable to hs-cTnT-Elecsys (AUC: 0.94; 95% CI: 0.93 to 0.96; p = 0.213) and hs-cTnI-Architect (AUC: 0.92; 95% CI: 0.90 to 0.93; p < 0.001). A single cutoff concentration <3 ng/l at presentation identified 45% of patients at low risk with a negative predictive value (NPV) of 100% (95% CI: 99.4% to 100%). A single cutoff concentration >60 ng/l identified patients at high risk with a positive predictive value (PPV) of 76.8% (95% CI: 68.9% to 83.6%). The 0/1-h algorithm ruled out 55% of patients (NPV: 100%; 95% CI: 98.8% to 100%), and ruled in 18% of patients (PPV: 76.8%; 95% CI: 67.2% to 84.7%). Ruled-out patients had cumulative event rates of 0% at 30 days and 1.6% at 2 years. This study confirmed these findings in a secondary analysis including hs-cTnI-Architect for central adjudication. CONCLUSIONS: The POC-hs-cTnI-TriageTrue assay provides high diagnostic accuracy in patients with suspected MI with a clinical performance that is at least comparable to that of best-validated central laboratory assays. (Advantageous Predictors of Acute Coronary Syndromes Evaluation Study [APACE]; NCT00470587).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Self-citationLevey, A. S., Coresh, J., Greene, T., Stevens, L. A., Zhang, Y. (., Hendriksen, S., Kusek, J. W., & Van Lente, F. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-4-200608150-00004 · Cited by 5,725
Third universal definition of myocardial infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., the Writing Group on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction, Authors/Task Force Members Chairpersons, Thygesen, K., Alpert, J. S., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs184 · Cited by 3,058
Self-citationEarly Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900428 · Cited by 1,687 · cited 6×
“Peripheral artery disease 59 (5) 25 (14) 34 (3) <0.”
BackgroundMethodInfluentialSelf-citationAnalytical Validation of a High-Sensitivity Cardiac Troponin T Assay
Giannitsis, E., Kurz, K., Hallermayer, K., Jarausch, J., Jaffe, A. S., & Katus, H. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.132654 · Cited by 1,084 · cited 4×
“Above 30 ng/l, the cTnT interassay CV were between 1% and 5% (2).”
BackgroundMethodInfluentialSTARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.246280 · Cited by 984
Reichlin, T., Schindler, C., Drexler, B., Twerenbold, R., Reiter, M., Zellweger, C., Moehring, B., Ziller, R., Hoeller, R., Rubini Gimenez, M., et al. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2012.3698 · Cited by 551
Self-citationClinical Use of High-Sensitivity Cardiac Troponin in Patients With Suspected Myocardial Infarction
Twerenbold, R., Boeddinghaus, J., Nestelberger, T., Wildi, K., Rubini Gimenez, M., Badertscher, P., & Mueller, C. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.718 · Cited by 255
Self-citationChew, D. P., Lambrakis, K., Blyth, A., Seshadri, A., Edmonds, M. J. R., Briffa, T., Cullen, L. A., Quinn, S., Karnon, J., Chuang, A., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.042891 · Cited by 226
Outcome of Applying the ESC 0/1-hour Algorithm in Patients With Suspected Myocardial Infarction
Twerenbold, R., Costabel, J. P., Nestelberger, T., Campos, R., Wussler, D., Arbucci, R., Cortes, M., Boeddinghaus, J., Baumgartner, B., Nickel, C. H., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.05.046 · Cited by 201 · cited 4×
“Peripheral artery disease 59 (5) 25 (14) 34 (3) <0.”
MethodResultInfluentialSelf-citationBoeddinghaus, J., Twerenbold, R., Nestelberger, T., Badertscher, P., Wildi, K., Puelacher, C., du Fay de Lavallaz, J., Keser, E., Rubini Giménez, M., Wussler, D., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2018.286906 · Cited by 158 · cited 2×
“Therefore, the reference standard applied in this large diagnostic study of patients presenting with suspected MI seems to be very stringent and robust (15).”
BackgroundSelf-citationKrintus, M., Kozinski, M., Boudry, P., Capell, N. E., Köller, U., Lackner, K., Lefèvre, G., Lennartz, L., Lotz, J., Herranz, A. M., et al. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0107 · Cited by 153 · cited 2×
“Previous stroke 81 (6) 19 (11) 62 (6) 0.”
Point-of-Care Testing Reduces Length of Stay in Emergency Department Chest Pain Patients
Singer, A. J., Ardise, J., Gulla, J., & Cangro, J. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.11.020 · Cited by 149
Stoyanov, K. M., Hund, H., Biener, M., Gandowitz, J., Riedle, C., Lohr, J. M., Mueller‐Hennessen, M., Vafaie, M., Katus, H. A., & Giannitsis, E. (2019) · European Heart Journal Acute Cardiovascular Care · doi:10.1177/2048872619861911 · Cited by 111 · cited 1×
“With the clinical availability of a POC-hs-cTnI-TriageTrue assay with an at least comparable diagnostic accuracy to the best-validated central laboratory hs-cTnT/I assays and a very safe and highly efficacious POC-hscTnI-TriageTrue 0/1-h algorithm, the time to diagnosis and to discharge from the ED can be expected to…”
MethodAnand, A., Shah, A. S. V., Beshiri, A., Jaffe, A. S., & Mills, N. L. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2018.298059 · Cited by 107
Rapid rule out of acute myocardial infarction: novel biomarker-based strategies
Mueller, C. E., Giannitsis, E., Möckel, M., Huber, K., Mair, J. M., Plebani, M., Thygesen, K. A., Jaffe, A. S., & Lindahl, B. (2016) · European Heart Journal Acute Cardiovascular Care · doi:10.1177/2048872616653229 · Cited by 102
Self-citationDiagnostic Evaluation of a High-Sensitivity Troponin I Point-of-Care Assay
Sörensen, N. A., Neumann, J. T., Ojeda, F., Giannitsis, E., Spanuth, E., Blankenberg, S., Westermann, D., & Zeller, T. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2019.307405 · Cited by 91 · cited 2×
“7 inches) demonstrated high sensitivity (27) as well as diagnostic performance comparable to that of hscTnI-Architect (28).”
BackgroundPickering, J. W., Young, J. M., George, P. M., Watson, A. S., Aldous, S. J., Troughton, R. W., Pemberton, C. J., Richards, A. M., Cullen, L. A., & Than, M. P. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.3368 · Cited by 81 · cited 2×
“Our findings are supported by encouraging data from a recent pilot study of the new POC-I-Stat TnINx assay (Abbott Diagnostics), showing comparable AUC versus hs-cTnI-Architect (26).”
ResultAmundson, B. E., & Apple, F. S. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0837 · Cited by 75 · cited 2×
“Previous MI 280 (22) 71 (40) 209 (19) <0.”
BackgroundApple, F. S., Chung, A., Kogut, M. E., Bubany, S., & Murakami, M. M. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.02.011 · Cited by 75 · cited 1×
“Previous MI 280 (22) 71 (40) 209 (19) <0.”
A prospective randomized controlled trial of point-of-care testing on the coronary care unit
Collinson, P., John, C., Lynch, S., Rao, A., Canepa-Anson, R., Carson, E., & Cramp, D. (2004) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563041731547 · Cited by 62
Loten, C., Attia, J., Hullick, C., Marley, J., & McElduff, P. (2010) · Emergency Medicine Journal · doi:10.1136/emj.2008.069427 · Cited by 53
Diagnostic accuracy of the T-MACS decision aid with a contemporary point-of-care troponin assay
Body, R. M., Almashali, M., Morris, N., Moss, P., Jarman, H., Appelboam, A., Parris, R. J., Chan, L., Walker, A., Harrison, M., et al. (2019) · Heart · doi:10.1136/heartjnl-2018-313825 · Cited by 38 · cited 4×
“To overcome the lack of sensitivity, 1 strategy was to use POC-cTn in combination with a formal clinical risk score (24).”
MethodInfluentialChristenson, R. H., Mullins, K., & Duh, S. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.05.004 · Cited by 35 · cited 2×
“7 inches) demonstrated high sensitivity (27) as well as diagnostic performance comparable to that of hscTnI-Architect (28).”
Backgroundter Avest, E., Visser, A., Reitsma, B., Breedveld, R., & Wolthuis, A. M. (2015) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000000225 · Cited by 30
Cited by
Collet, J.-P., Thiele, H., Barbato, E., Barthélémy, O., Bauersachs, J., Bhatt, D. L., Dendale, P., Dorobantu, M., Edvardsen, T., Folliguet, T., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa575 · Cited by 5,037
Self-citationSkeletal Muscle Disorders: A Noncardiac Source of Cardiac Troponin T
du Fay de Lavallaz, J., Prepoudis, A., Wendebourg, M. J., Kesenheimer, E., Kyburz, D., Daikeler, T., Haaf, P., Wanschitz, J., Löscher, W. N., Schreiner, B., et al. (2022) · Circulation · doi:10.1161/circulationaha.121.058489 · Cited by 121
Self-citationBrisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Safety, Efficiency, and Cost Conflicts in Emergency Department Point of Care Troponin Testing
Grabinski, Z., Swartz, J. L., Wang, Y., Itani, A., Aguero-Rosenfeld, M., Sanchez, N., Gulati, R., Wittman, I. G., & Smith, S. W. (2026) · Quality Management in Health Care · doi:10.1097/qmh.0000000000000502
Metadata
- Authors
- Boeddinghaus, J., Nestelberger, T., Koechlin, L., Wussler, D., Lopez-Ayala, P., Walter, J. E., Troester, V., Ratmann, P. D., Seidel, F., Zimmermann, T., Badertscher, P., Wildi, K., Rubini Giménez, M., Potlukova, E., Strebel, I., Freese, M., Miró, Ò., Martin-Sanchez, F. J., Kawecki, D., Keller, D. I., Gualandro, D. M., Christ, M., Twerenbold, R., Mueller, C., Meier, M., Puelacher, C., du Fay de Lavallaz, J., Kozhuharov, N., Rentsch, K., Stelzig, C., Meissner, K., Kulangara, C., Hillinger, P., Michou, E., Flores, D., Reichlin, T., López, B., Fuenzalida, C., Adrada, E. R., Ganovská, E., Lohrmann, J., Huber, J., Steude, J., Buser, A., von Eckardstein, A., Morawiec, B., Nowalany-Kozielska, E., Muzyk, P., Bürgler, F., & Geigy, N.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 75
- Issue
- 10
- Pages
- 1111-1124
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W3010588636
- Cited by
- 171
- References
- 26
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.