The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Kinetics of skin resealing after insertion of microneedles in human subjects
Open accessAbstract
Over the past decade, microneedles have been shown to dramatically increase skin permeability to a broad range of compounds by creating reversible microchannels in the skin. However, in order to achieve sustained transdermal drug delivery, the extent and duration of skin‘s increased permeability needs to be determined. In this study, we used electrical impedance spectroscopy to perform the first experiments in human subjects to analyze the resealing of skin‘s barrier properties after insertion of microneedles. Microneedles having a range of geometries were studied in conjunction with the effect of occlusion to test the hypothesis that increasing microneedle length, number, and cross-sectional area together with occlusion leads to an increase in skin resealing time that can exceed one day. Results indicated that in the absence of occlusion, all microneedle treated sites recovered barrier properties within 2 h, while occluded sites resealed more slowly, with resealing windows ranging from 3-40 h depending on microneedle geometry. Upon subsequent removal of occlusion, the skin barrier resealed rapidly. Longer microneedles, increased number of needles, and larger cross-sectional area demonstrated slower resealing kinetics indicating that microneedle geometry played a significant role in the barrier resealing process. Overall, this study showed that pre-treatment of skin with microneedles before applying an occlusive transdermal patch can increase skin permeability for more than one day, but nonetheless allow skin to reseal rapidly after patch removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Self-citationMicrofabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346
Self-citationNonlinear Models for Repeated Measurement Data
Young, D. A., Davidian, M., & Giltinan, D. M. (1997) · Journal of the American Statistical Association · doi:10.2307/2965730 · Cited by 1,220
Dissolving polymer microneedle patches for influenza vaccination
Sullivan, S. P., Koutsonanos, D. G., del Pilar Martin, M., Lee, J. W., Zarnitsyn, V., Choi, S.-O., Murthy, N., Compans, R. W., Skountzou, I., & Prausnitz, M. R. (2010) · Nature Medicine · doi:10.1038/nm.2182 · Cited by 948
Self-citationMcAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationChemical and Physical Behavior of Human Hair
Robbins, C. R. (2012) · Springer eBooks · doi:10.1007/978-3-642-25611-0 · Cited by 857
Nonlinear Models for Repeated Measurement Data
Timm, N. H. (1996) · Technometrics · doi:10.1080/00401706.1996.10484472 · Cited by 810
Coated microneedles for transdermal delivery
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.017 · Cited by 765
Self-citationMicroneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Effect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701
Self-citation
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationMicroneedle technologies for (trans)dermal drug and vaccine delivery
van der Maaden, K., Jiskoot, W., & Bouwstra, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.042 · Cited by 651
Transdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Makvandi, P., Kirkby, M., Hutton, A. R. J., Shabani, M., Yiu, C. K. Y., Baghbantaraghdari, Z., Jamaledin, R., Carlotti, M., Mazzolai, B., Mattoli, V., et al. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00611-9 · Cited by 455
Microneedles: an emerging transdermal drug delivery system
Bariya, S. H., Gohel, M. C., Mehta, T. A., & Sharma, O. P. (2012) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.2011.01369.x · Cited by 455
A bio-inspired swellable microneedle adhesive for mechanical interlocking with tissue
Yang, S. Y., O'Cearbhaill, E. D., Sisk, G. C., Park, K. M., Cho, W. K., Villiger, M., Bouma, B. E., Pomahac, B., & Karp, J. M. (2013) · Nature Communications · doi:10.1038/ncomms2715 · Cited by 448
Microneedle for transdermal drug delivery: current trends and fabrication
Jung, J. H., & Jin, S. G. (2021) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-021-00512-4 · Cited by 416
Polymeric microneedles for transdermal protein delivery
Ye, Y., Yu, J., Wen, D., Kahkoska, A. R., & Gu, Z. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.01.015 · Cited by 324
Topical and Transdermal Drug Delivery: From Simple Potions to Smart Technologies
Benson, H. A. E., Grice, J. E., Mohammed, Y., Namjoshi, S., & Roberts, M. S. (2019) · Current Drug Delivery · doi:10.2174/1567201816666190201143457 · Cited by 303
Bhatnagar, S., Dave, K., & Venuganti, V. V. K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.05.029 · Cited by 297
Microneedle patches: Usability and acceptability for self-vaccination against influenza
Norman, J. J., Arya, J. M., McClain, M. A., Frew, P. M., Meltzer, M. I., & Prausnitz, M. R. (2014) · Vaccine · doi:10.1016/j.vaccine.2014.01.076 · Cited by 281
Self-citationLing, M.-H., & Chen, M.-C. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.029 · Cited by 280
Insulin delivery systems combined with microneedle technology
Jin, X., Zhu, D. D., Chen, B. Z., Ashfaq, M., & Guo, X. D. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.03.011 · Cited by 275
Fully embeddable chitosan microneedles as a sustained release depot for intradermal vaccination
Chen, M.-C., Huang, S.-F., Lai, K.-Y., & Ling, M.-H. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.12.041 · Cited by 271
Microneedle-mediated transdermal drug delivery for treating diverse skin diseases
Yang, D., Chen, M., Sun, Y., Jin, Y., Lu, C., Pan, X., Quan, G., & Wu, C. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.12.004 · Cited by 259
Song, Y., Li, J., & Wu, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01952-8 · Cited by 259
Chitosan Microneedle Patches for Sustained Transdermal Delivery of Macromolecules
Chen, M.-C., Ling, M.-H., Lai, K.-Y., & Pramudityo, E. (2012) · Biomacromolecules · doi:10.1021/bm301293d · Cited by 259
Microneedle-Based Delivery: An Overview of Current Applications and Trends
Guillot, A. J., Cordeiro, A. S., Donnelly, R. F., Montesinos, M. C., Garrigues, T. M., & Melero, A. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060569 · Cited by 254
Microneedling: A Review and Practical Guide
Alster, T. S., & Graham, P. M. (2018) · Dermatologic Surgery · doi:10.1097/dss.0000000000001248 · Cited by 235
Granulomatous Reactions From Microneedling: A Systematic Review of the Literature
Friedmann, D. P., Mehta, E., Verma, K. K., & Harris, R. (2025) · Dermatologic Surgery · doi:10.1097/dss.0000000000004450 · Cited by 8
Metadata
- Authors
- Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2011-09
- Volume
- 154
- Issue
- 2
- Pages
- 148-155
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2158003101
- Cited by
- 342
- References
- 40
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.