The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Kinetics of skin resealing after insertion of microneedles in human subjects
Open accessAbstract
Over the past decade, microneedles have been shown to dramatically increase skin permeability to a broad range of compounds by creating reversible microchannels in the skin. However, in order to achieve sustained transdermal drug delivery, the extent and duration of skin‘s increased permeability needs to be determined. In this study, we used electrical impedance spectroscopy to perform the first experiments in human subjects to analyze the resealing of skin‘s barrier properties after insertion of microneedles. Microneedles having a range of geometries were studied in conjunction with the effect of occlusion to test the hypothesis that increasing microneedle length, number, and cross-sectional area together with occlusion leads to an increase in skin resealing time that can exceed one day. Results indicated that in the absence of occlusion, all microneedle treated sites recovered barrier properties within 2 h, while occluded sites resealed more slowly, with resealing windows ranging from 3-40 h depending on microneedle geometry. Upon subsequent removal of occlusion, the skin barrier resealed rapidly. Longer microneedles, increased number of needles, and larger cross-sectional area demonstrated slower resealing kinetics indicating that microneedle geometry played a significant role in the barrier resealing process. Overall, this study showed that pre-treatment of skin with microneedles before applying an occlusive transdermal patch can increase skin permeability for more than one day, but nonetheless allow skin to reseal rapidly after patch removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Self-citationMicrofabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346
Self-citationNonlinear Models for Repeated Measurement Data
Young, D. A., Davidian, M., & Giltinan, D. M. (1997) · Journal of the American Statistical Association · doi:10.2307/2965730 · Cited by 1,220
Dissolving polymer microneedle patches for influenza vaccination
Sullivan, S. P., Koutsonanos, D. G., del Pilar Martin, M., Lee, J. W., Zarnitsyn, V., Choi, S.-O., Murthy, N., Compans, R. W., Skountzou, I., & Prausnitz, M. R. (2010) · Nature Medicine · doi:10.1038/nm.2182 · Cited by 948
Self-citationMcAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationChemical and Physical Behavior of Human Hair
Robbins, C. R. (2012) · Springer eBooks · doi:10.1007/978-3-642-25611-0 · Cited by 857
Nonlinear Models for Repeated Measurement Data
Timm, N. H. (1996) · Technometrics · doi:10.1080/00401706.1996.10484472 · Cited by 810
Coated microneedles for transdermal delivery
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.017 · Cited by 765
Self-citationMicroneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Effect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701
Self-citationElectrical properties of the epidermal stratum corneum
Yamamoto, T., & Yamamoto, Y. (1976) · Medical & Biological Engineering · doi:10.1007/bf02478741 · Cited by 436
Transepidermal water loss: the signal for recovery of barrier structure and function.
Grubauer, G., Elias, P. M., & Feingold, K. R. (1989) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)38361-9 · Cited by 411
Transdermal delivery of desmopressin using a coated microneedle array patch system
Cormier, M., Johnson, B. L., Ameri, M., Nyam, K., LIBIRAN, L., Zhang, D. D., & Daddona, P. E. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.04.003 · Cited by 388
Skin barrier : principles of percutaneous absorption
Schaefer, H. E., & Redelmeier, T. E. (1996) · Cited by 361
Van Damme, P., Oosterhuis-Kafeja, F., Van der Wielen, M., Almagor, Y., Sharon, O., & Levin, Y. (2009) · Vaccine · doi:10.1016/j.vaccine.2008.10.077 · Cited by 331
Clinical administration of microneedles: skin puncture, pain and sensation
Haq, M. I., Smith, E., John, D. N., Kalavala, M., Edwards, C., Anstey, A., Morrissey, A., & Birchall, J. C. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9208-1 · Cited by 329
Chemical and Physical Behavior of Human Hair
Robbins, C. R. (2002) · Springer eBooks · doi:10.1007/b97447 · Cited by 320
Microneedles permit transdermal delivery of a skin-impermeant medication to humans
Wermeling, D. P., Banks, S. L., Hudson, D. A., Gill, H. S., Gupta, J., Prausnitz, M. R., & Stinchcomb, A. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710355105 · Cited by 311
Self-citationIn vivo assessment of safety of microneedle arrays in human skin
Bal, S. M., Caussin, J., Pavel, S., & Bouwstra, J. A. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.06.016 · Cited by 303
Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone
Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R. (2011) · Small · doi:10.1002/smll.201001091 · Cited by 301
Self-citationSkin Barrier: Principles of Percutaneous Absorption
Potts, R. (1997) · Archives of Dermatology · doi:10.1001/archderm.1997.03890430146031 · Cited by 298
Bioengineering of the skin: Water and the stratum corneum
Edwards, D. A. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(95)90005-5 · Cited by 290
Lamellar Body Secretory Response to Barrier Disruption
Menon, G. K., Feingold, K. R., & Elias, P. M. (1992) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12497866 · Cited by 289
Holland, D., Booy, R., Looze, F. D., Eizenberg, P., McDonald, J., Karrasch, J., McKeirnan, M., Salem, H., Mills, G., Reid, J., et al. (2008) · The Journal of Infectious Diseases · doi:10.1086/590434 · Cited by 254
The effects of electric current applied to skin: A review for transdermal drug delivery
Prausnitz, M. R. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00081-h · Cited by 213
Self-citationMinimally Invasive Insulin Delivery in Subjects with Type 1 Diabetes Using Hollow Microneedles
Gupta, J., Felner, E. I., & Prausnitz, M. R. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0103 · Cited by 209
Self-citationClinical microneedle injection of methyl nicotinate: stratum corneum penetration
Sivamani, R. K., Stoeber, B., Wu, G. C., Zhai, H., Liepmann, D., & Maibach, H. (2005) · Skin Research and Technology · doi:10.1111/j.1600-0846.2005.00107.x · Cited by 171
Mikszta, J. A., Sullivan, V. J., Dean, C., Waterston, A. M., Alarcon, J. B., Dekker III, J. P., Brittingham, J. M., Huang, J., Hwang, C. R., Ferriter, M., et al. (2005) · The Journal of Infectious Diseases · doi:10.1086/426865 · Cited by 160
Microneedle arrays for the transcutaneous immunization of diphtheria and influenza in BALB/c mice
Ding, Z., Verbaan, F. J., Bivas‐Benita, M., Bungener, L. B., Huckriede, A. L. W., van den Berg, D., Kersten, G. F. A., & Bouwstra, J. A. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.01.025 · Cited by 155
Vaccines for Pandemic Influenza
Luke, C. J., & Subbarao, K. (2006) · Emerging infectious diseases · doi:10.3201/eid1201.051147 · Cited by 154
Cutaneous vaccination using microneedles coated with hepatitis C DNA vaccine
Gill, H. S., Söderholm, J., Prausnitz, M. R., & Sällberg, M. (2010) · Gene Therapy · doi:10.1038/gt.2010.22 · Cited by 152
Self-citationMicrofabricated silicon microneedles for nonviral cutaneous gene delivery
Chabri, F., Bouris, K., Jones, T., Barrow, D., Hann, A. C., Allender, C. J., Brain, K., & Birchall, J. C. (2004) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2004.05921.x · Cited by 152
Bioengineering of the skin : water and the stratum corneum
Fluhr, J. W., Elsner, P. U., Berardesca, E., & Maïbach, H. I. (1994) · Cited by 145
Coulman, S. A., Birchall, J. C., Alex, A., Pearton, M., Höfer, B., O’Mahony, C., Drexler, W., & Považay, B. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0167-x · Cited by 132
Mechanisms of Transdermal Drug Delivery
Walters, K. A. (1998) · The Journal of the British Menopause Society · doi:10.1177/136218079800400205 · Cited by 75
Banks, S. L., Reddy, P. R., Gill, H. S., Paudel, K. S., Crooks, P. A., Brogden, N. K., Prausnitz, M. R., & Stinchcomb, A. L. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22083 · Cited by 70
Self-citationCurdy, C., Naik, A., Kalia, Y. N., Alberti, I., & Guy, R. H. (2004) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2003.11.016 · Cited by 68
In vivovisualization of microneedle conduits in human skin using laser scanning microscopy
Bal, S. M., Kruithof, A. C., Liebl, H., Tomerius, M., Bouwstra, J. A., Lademann, J. M., & Meinke, M. C. (2010) · Laser Physics Letters · doi:10.1002/lapl.200910134 · Cited by 67
Microneedle pretreatment improves efficacy of cutaneous topical anesthesia
Li, X., Zhao, R., Qin, Z., et al. (2010) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2008.10.001 · Cited by 39
A ‘biorelevant’ system to investigate in vitro drug released from a naltrexone implant
Iyer, S. S., Barr, W. H., Dance, M. E., COLEMAN, P., & Karnes, H. T. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.03.032 · Cited by 30
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationMicroneedle technologies for (trans)dermal drug and vaccine delivery
van der Maaden, K., Jiskoot, W., & Bouwstra, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.042 · Cited by 651
Transdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Makvandi, P., Kirkby, M., Hutton, A. R. J., Shabani, M., Yiu, C. K. Y., Baghbantaraghdari, Z., Jamaledin, R., Carlotti, M., Mazzolai, B., Mattoli, V., et al. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00611-9 · Cited by 455
Metadata
- Authors
- Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2011-09
- Volume
- 154
- Issue
- 2
- Pages
- 148-155
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2158003101
- Cited by
- 342
- References
- 40
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.