Wavefront-optimized ablation profiles: Theoretical background
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
PURPOSE: To describe a method for calculating wavefront-optimized ablation profiles to precompensate for the spherical aberration and higher-order astigmatism induced by myopic, hyperopic, and astigmatic corneal laser corrections. SETTING: IROC-Institut für Refraktive und Ophthalmo-Chirurgie, and Institute for Biomedical Engineering, Swiss Federal Institute of Technology, Zürich, Switzerland. METHODS: The basic ablation profile for myopic, hyperopic, and astigmatic correction is derived from the 2nd-order Zernike representation of wavefront aberrations. Including 4th-order spherical aberration and higher-order astigmatism in the theoretical calculation of the ablation profile allows precompensation for the expected amount of higher-order aberrations (HOAs). The shapes of wavefront-optimized ablation profiles are compared with the shapes of "classic" ablation profiles for myopic and astigmatic corrections. RESULTS: The introduction of precompensating spherical aberration and higher-order astigmatism leads to a more aspheric ablation profile with a significant increase in ablation depth (up to 35%) in the midperiphery of the optical zone. The central ablation depth remains unchanged in the myopic correction but increases by 3% in cylinder correction. CONCLUSIONS: Wavefront-optimized ablation profiles provide a simple method to precompensate for the expected 4th-order spherical aberration and higher-order astigmatism in the average eye. Further clinical studies must be performed to prove the theoretical results; demonstrate the reduction in HOAs; and predict safety, predictability, and stability of wavefront-optimized ablation profiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards for Reporting the Optical Aberrations of Eyes
Thibos, L. N., Applegate, R. A., Schwiegerling, J. T., Webb, R., & Members, V. S. T. (2000) · Vision Science and its Applications · doi:10.1364/vsia.2000.suc1 · Cited by 824
Photorefractive keratectomy: A technique for laser refractive surgery
Munnerlyn, C. R., Koons, S. J., & Marshall, J. (1988) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(88)80063-4 · Cited by 763
Monochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
Moreno-Barriuso, E., Lloves, J. M., Marcos, S. C., Navarro, R., Llorente, L., & Barbero, S. (2001) · PubMed · Cited by 475
Accommodation-dependent model of the human eye with aspherics
Navarro, R., Santamaría, J., & Bescós, J. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001273 · Cited by 438
OSA trends in optics and photonics
Solli, McCormick, C., Popescu, S., Chiao, R. Y., & Hickman, J. (2003) · Cited by 388
The Cornea is Not a Piece of Plastic
Roberts, C. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000701-03 · Cited by 326
Corneal Aberrations and Visual Performance After Radial Keratotomy
Applegate, R. A., Howland, H. C., Sharp, R. P., Cottingham, A. J., & Yee, R. W. (1998) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19980701-05 · Cited by 307 · cited 3×
“2(n 1) (R 2 r (2)) (8) Z5 · 2 cos(2 ) (3)”
BackgroundGuirao, A., Williams, D. R., & Cox, I. G. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001003 · Cited by 292
Aberrations and Visual Performance Following Standard Laser Vision Correction
Marcos, S. C. (2001) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20010901-19 · Cited by 289 · cited 3×
“relDiff ( , ) aopt ( , ) aclass ( , ) aclass ( , ) · 100% (18)”
BackgroundMethodInfluentialOptical response to LASIK surgery for myopia from total and corneal aberration measurements.
Marcos, S. C., Barbero, S., Llorente, L., & Merayo-Llovés, J. (2001) · PubMed · Cited by 282
Mrochen, M., Kaemmerer, M., Mierdel, P., & Seiler, T. (2001) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(00)00806-3 · Cited by 280
Self-citationRegional elastic performance of the human cornea
Hjortdal, J. Ø. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00152-2 · Cited by 231
Vision Science and its Applications
Howland, H. C., Tyler, C. J., Birch, E. E., & Rosenberg, R. (1996) · Optics and Photonics News · Cited by 222
Thermal and Biomechanical Parameters of Porcine Cornea
Kampmeier, J., Radt, B., Birngruber, R., & Brinkmann, R. (2000) · Cornea · doi:10.1097/00003226-200005000-00020 · Cited by 210
Reinstein, D. Z., Silverman, R. H., Raevsky, T., Simoni, G. J., Lloyd, H. O., Najafi, D. J., Rondeau, M. J., & Coleman, D. J. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000701-04 · Cited by 203
Excimer Laser Ablation Rate and Corneal Hydration
Dougherty, P. J., Wellish, K. L., & Maloney, R. K. (1994) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)72896-x · Cited by 201
Reinstein, D. Z., Silverman, R. H., Sutton, H. F. S., & Coleman, D. J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90105-7 · Cited by 183
A Method to Predict Refractive Errors from Wave Aberration Data
Guirao, A., & Williams, A. (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01588.x · Cited by 162
Mathematical model of corneal surface smoothing after laser refractive surgery
Huang, D., Tang, M., & Shekhar, R. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01942-6 · Cited by 158
Visual Performance After Photorefractive Keratectomy
Verdon, W. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100140663003 · Cited by 151
Spadea, L., Fasciani, R., Necozione, S., & Balestrazzi, E. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000301-05 · Cited by 151
In vitro measurement of corneal strain, thickness, and curvature using digital image processing
Hjortdal, J. Ø., & Jensen, P. K. (1995) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.1995.tb00004.x · Cited by 133
The distribution of strain in the human cornea
Shin, T. J., Vito, R. P., Johnson, L. W., & McCarey, B. E. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)84433-8 · Cited by 129
Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablation
Bueeler, M., Mrochen, M., & Seiler, T. G. (2003) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(02)01638-3 · Cited by 126
Self-citationAblation profiles for wavefront-guided correction of myopia and primary spherical aberration
Manns, F., Ho, A., Parel, J.-M. A., & Culbertson, W. W. (2002) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(01)01322-0 · Cited by 122
Spot size and quality of scanning laser correction of higher-order wavefront aberrations
Huang, D., & Arif, M. (2002) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(01)01163-4 · Cited by 106
Improvement in photorefractive corneal laser surgery results using an active eye-tracking system
Mrochen, M., Eldine, M. S., Kaemmerer, M., Seiler, T. G., & Hütz, W. W. (2001) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(00)00884-1 · Cited by 82
Self-citationEffect of Beam Size on the Expected Benefit of Customized Laser Refractive Surgery
Guirao, A., Williams, D. R., & Macrae, S. M. (2003) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20030101-04 · Cited by 76
Epithelial Alterations Following Photorefractive Keratectomy for Myopia
Gauthier, C. A., Epstein, D., Holden, B. A., Tengroth, B., Fagerholm, P., Hamberg‐Nyström, H., & Sievert, R. (1995) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19950301-11 · Cited by 63
Anterior Corneal Optical Aberrations Induced by Photorefractive Keratectomy for Hyperopia
Oliver, K. M., O'Brart, D. P. S., Stephenson, C. G., Hemenger, R. P., Applegate, R. A., Tomlinson, A., & Marshall, J. (2001) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20010701-01 · Cited by 53 · cited 2×
“2(n 1) · (S C ) (7) notation (tabo angle notation).”
BackgroundMathematical Treatment of Ocular Aberrations: a User’s Guide
Atchison, D. A., Scott, D. H., & Cox, M. J. (2000) · Vision Science and its Applications (VSIA) · doi:10.1364/vsia.2000.nw2 · Cited by 31
Development of an algorithm for corneal reshaping with a scanning laser beam
Manns, F., Shen, J.-H., Söderberg, P. G., Matsui, T., & Parel, J.-M. A. (1995) · Applied Optics · doi:10.1364/ao.34.004600 · Cited by 17
Cited by
Wavefront Ablation Profiles in Refractive Surgery: Description, Results, and Limitations
Smadja, D., Reggiani-Mello, G., Santhiago, M. R., & Krueger, R. R. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20120217-01 · Cited by 58
Metadata
- Authors
- Mrochen, M., Donitzky, C., Wüllner, C., & Löffler, J.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2004-04
- Volume
- 30
- Issue
- 4
- Pages
- 775-785
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2141025744
- Cited by
- 209
- References
- 33
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.