Tutorial. Surface EMG detection in space and time: Best practices
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
This tutorial is aimed to non-engineers using, or planning to use, surface electromyography (sEMG) as an assessment tool in the prevention, monitoring and rehabilitation fields. Its first purpose is to address the issues related to the origin and nature of the signal and to its detection (electrode size, distance, location) by one-dimensional (bipolar and linear arrays) and two-dimensional (grids) electrode systems while avoiding advanced mathematical, physical or physiological issues. Its second purpose is to outline best practices and provide general guidelines for proper signal detection. Issues related to the electrode-skin interface, signal conditioning and interpretation will be discussed in subsequent tutorials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725
A method for positioning electrodes during surface EMG recordings in lower limb muscles
Rainoldi, A., Melchiorri, G., & Caruso, I. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.014 · Cited by 610
European recommendations for surface electromyography results of the SENIAM project
Hermens, H. J. (1999) · Cited by 581
Surface Electromyography : Physiology, Engineering, and Applications
(2016) · doi:10.1002/9781119082934 · Cited by 462
Self-citationInterpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Atlas of Muscle Innervation Zones
Barbero, M., Merletti, R., & Rainoldi, A. (2012) · Springer eBooks · doi:10.1007/978-88-470-2463-2 · Cited by 419
Self-citationInfluence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
Self-citationSurface myoelectric signal cross-talk among muscles of the leg
De Luca, C. J., & Merletti, R. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90169-1 · Cited by 339
Self-citationFuglevand, A. J., Winter, D. A., Patla, A. E., & Stashuk, D. (1992) · Biological Cybernetics · doi:10.1007/bf00201021 · Cited by 311
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285 · cited 1×
“The location of a pair of electrodes with respect to the innervation zone and to the muscle-tendon junctions of a fusiform muscle parallel to the skin surface, is critical (Farina et al., 2001; Merletti et al., 2003; Rainoldi et al., 2004, 2000) and its choice must be justified.”
BackgroundSelf-citationA novel approach for precise simulation of the EMG signal detected by surface electrodes
Farina, D., & Merletti, R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.923782 · Cited by 282
Self-citationEffects of electrode location on myoelectric conduction velocity and median frequency estimates
Roy, S. H., De Luca, C. J., & Schneider, J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.4.1510 · Cited by 260
A Surface EMG Generation Model With Multilayer Cylindrical Description of the Volume Conductor
Farina, D., Mesin, L., Martina, S., & Merletti, R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820998 · Cited by 230
Self-citationSurface EMG models: properties and applications
Stegeman, D. F., Blok, J. H., Hermens, H. J., & Roeleveld, K. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00023-7 · Cited by 209
Modeling of surface myoelectric signals. I. Model implementation
Merletti, R., Lo Conte, L., Avignone, E., & Guglielminotti, P. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771190 · Cited by 208
Self-citationSurface EMG: The issue of electrode location
Mesin, L., Merletti, R., & Rainoldi, A. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.07.006 · Cited by 200
Self-citationSurface EMG crosstalk between knee extensor muscles: Experimental and model results
Farina, D., Merletti, R., Indino, B., Nazzaro, M., & Pozzo, M. (2002) · Muscle & Nerve · doi:10.1002/mus.10256 · Cited by 199
Self-citationEffect of joint angle on EMG variables in leg and thigh muscles
Farina, D., Merletti, R., Nazzaro, M., & Caruso, I. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982277 · Cited by 197
Self-citationGeometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192
Self-citationDe Luca, C. J., Kuznetsov, M., Gilmore, L. D., & Roy, S. H. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.010 · Cited by 186
Probability density of the surface electromyogram and its relation to amplitude detectors
Clancy, E. A., & Hogan, N. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764949 · Cited by 181
Consensus for experimental design in electromyography (CEDE) project: Electrode selection matrix
Besomi, M., Hodges, P. W., Van Dieën, J., Carson, R. G., Clancy, E. A., Disselhorst-Klug, C., Holobar, A., Hug, F., Kiernan, M. C., Lowery, M., et al. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.07.008 · Cited by 165
Self-citationInfluence of electrode geometry on bipolar recordings of the surface electromyogram
Lynn, P. A., Bettles, N. D., Hughes, A., & Johnson, S. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442444 · Cited by 153
A multiple-layer finite-element model of the surface EMG signal
Lowery, M. M., Stoykov, N. S., Taflove, A., & Kuiken, T. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995683 · Cited by 152
Volume conduction models for surface EMG; confrontation with measurements
Roeleveld, K., Blok, J. H., Stegeman, D. F., & van Oosterom, A. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00009-6 · Cited by 141
Modeling of surface myoelectric signals. II. Model-based signal interpretation
Merletti, R., Roy, S. H., Kupa, E. J., Roatta, S., & Granata, A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771191 · Cited by 135
Self-citationA note on the probability distribution function of the surface electromyogram signal
Nazarpour, K., Al-Timemy, A. H., Bugmann, G., & Andrew, J. O. (2012) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2012.09.012 · Cited by 112
Selectivity of spatial filters for surface EMG detection from the tibialis anterior muscle
Farina, D., Arendt‐Nielsen, L., Merletti, R., Indino, B., & Graven‐Nielsen, T. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808830 · Cited by 89
Self-citationAfsharipour, B., Soedirdjo, S. D. H., & Merletti, R. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.12.001 · Cited by 87
Self-citationTemporary-tattoo for long-term high fidelity biopotential recordings
Bareket, L., Inzelberg, L., Rand, D., David-Pur, M., Rabinovich, D., Brandes, B., & Hanein, Y. (2016) · Scientific Reports · doi:10.1038/srep25727 · Cited by 86
Mesin, L., & Farina, D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827551 · Cited by 60
Specificity of surface EMG recordings for gastrocnemius during upright standing
Vieira, T., Botter, A., Muceli, S., & Farina, D. (2017) · Scientific Reports · doi:10.1038/s41598-017-13369-1 · Cited by 55
Self-citationThe spatial integration effect of surface electrode detecting myoelectric signal
Helal, J.-N., & Bouissou, P. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.168695 · Cited by 42
de Nooij, R., Kallenberg, L. A. C., & Hermens, H. J. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.03.013 · Cited by 31
Optimal spatio-temporal filter for the reduction of crosstalk in surface electromyogram
Mesin, L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f03 · Cited by 28
A multi-layer finite element model of the surface EMG signal
Lowery, M. M., Stoykov, N. S., Taflove, A., & Kuiken, T. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1020369 · Cited by 14
Cited by
Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
Del Vecchio, A., Holobar, A., Falla, D., Felici, F., Enoka, R. M., & Farina, D. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102426 · Cited by 372
Surface EMG in Clinical Assessment and Neurorehabilitation: Barriers Limiting Its Use
Campanini, I., Disselhorst-Klug, C., Rymer, W. Z., & Merletti, R. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00934 · Cited by 270
Self-citationTutorial. Surface EMG detection, conditioning and pre-processing: Best practices
Merletti, R., & Cerone, G. L. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102440 · Cited by 233
“Efforts in this direction are continuing with a series of consensus and tutorial papers (Besomi et al., 2019; Merletti and Muceli, 2019).”
BackgroundMethodSelf-citationMcManus, L., De Vito, G., & Lowery, M. M. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.576729 · Cited by 192
Gallina, A., Disselhorst-Klug, C., Farina, D., Merletti, R., Besomi, M., Holobar, A., Enoka, R. M., Hug, F., Falla, D., Søgaard, K., et al. (2022) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2022.102656 · Cited by 77
Self-citation
Metadata
- Authors
- Merletti, R., & Muceli, S.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 49
- Pages
- 102363
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2980412925
- Cited by
- 290
- References
- 39
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.