The DOI matches its Crossref record; 156 of the 159 references it cites were found in a registry or an index.
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Abstract
The physical basis for electrical stimulation of excitable tissue, as used by electrophysiological researchers and clinicians in functional electrical stimulation, is presented with emphasis on the fundamental mechanisms of charge injection at the electrode/tissue interface. Faradaic and non-Faradaic charge transfer mechanisms are presented and contrasted. An electrical model of the electrode/tissue interface is given. The physical basis for the origin of electrode potentials is given. Various methods of controlling charge delivery during pulsing are presented. Electrochemical reversibility is discussed. Commonly used electrode materials and stimulation protocols are reviewed in terms of stimulation efficacy and safety. Principles of stimulation of excitable tissue are reviewed with emphasis on efficacy and safety. Mechanisms of damage to tissue and the electrode are reviewed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, all data used in this study to fit and validate the model used symmetric, biphasic pulse trains, while other pulse shapes might lead to different neural or behavioral responses (Merrill et al., 2005).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Merrill et al., 2005
In the citing paper
“A critical aspect of electrical stimulation is its higher level of safety risk compared to recording electrical activity, which can result in both electrode and tissue damage.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [16]
In the citing paper
“Similarly, Merrill et al. noted that a narrow pulse is desirable to decrease occurrence of electrochemical reactions, and therefore reduce electrode degradation [2].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“In terms of electrode corrosion, however, slightly unbalanced biphasic pulses might be advantageous [2, 77].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“Charge injection at an electrode occurs through capacitive charge transfer, with no electron transfer across the electrodeelectrolyte interface, and Faradaic charge transfer, where electron transfer and reduction and oxidation (redox) reactions occur [101], [114].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“To minimise potentially toxic redox reaction products, biphasic stimulation reverses the charge injection in a second phase of a stimulation pulse aiming to reverse Faradaic reactions.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Faradaic reactions where products are not available for the reverse reaction are not reversed, for example hydrolysis of water or 'water window' which places safety limits on electrode-electrolyte interface potentials [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“In a biphasic pulse neuron activation occurs at a lower threshold for cathodic (sink) currents [101], [119], compared to positive anodic (source) currents.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Typical stimulation pulse widths range up to a few hundred μs , and current amplitudes vary from tens of μA to a few mA in peripheral nerve interfaces [9], [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Nitric oxide: physiology, pathophysiology, and pharmacology.
Moncada, S., Palmer, R. M., & Higgs, E. A. (1991) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06663-3 · Cited by 15,525
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,150
Bliss, T. V. P., & Gardner-Medwin, A. R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010274 · Cited by 7,424
Ionic channels of excitable membranes
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90172-7 · Cited by 7,134
Beckman, J. S., Beckman, T. W., Chen, J., Marshall, P. A., & Freeman, B. A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.4.1620 · Cited by 7,029
The Electrical Double Layer and the Theory of Electrocapillarity.
Grahame, D. C. (1947) · Chemical Reviews · doi:10.1021/cr60130a002 · Cited by 3,324
Inhibition of Cell Division in Escherichia coli by Electrolysis Products from a Platinum Electrode
Rosenberg, B., Camp, L. V., & Krigas, T. (1965) · Nature · doi:10.1038/205698a0 · Cited by 3,052
Reactive Oxygen Species and the Central Nervous System
Halliwell, B. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb10990.x · Cited by 2,947
(1981) · Handbook of exploration geochemistry · doi:10.1016/b978-0-444-41930-9.50014-3 · Cited by 2,903
Flagged first, then by citations
3 of the 159 references couldn’t be matched to a known paper.
Research works printed but not linked: 5
- Bhargava A. Long-term effects of quasi-trapezoidal pulses on the structure and function of sacral anterior roots. M.S. thesis, Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 1993.
- Guoy, 1910, Constitution of the electric charge at the surface of an electrolyte, J Physique, 9, 457
- Kennedy, 1999, Neural activity during acquisition of cursor control in a locked-in patient, Soc Neurosci Abstr, 25, 894
- Rall, 1977, vol.1/part 1
- Sevanian, 1988, Lipid peroxidation, membrane damage, and phospholipase A2 action: cellular antioxidant defense mechanisms, CRC Rev., II, 77
Cited by
Sorted by citations
Items 701–800 of 1,003
Plocksties, F. V., Kober, M., Niemann, C., Heller, J., Fauser, M., Nüssel, M., Uster, F., Franz, D., Zwar, M., Lüttig, A., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac23e1 · Cited by 24
Effects of nanostructuration on the electrochemical performance of metallic bioelectrodes
Mobini, S., González, M. U., Caballero‐Calero, O., Patrick, E. E., Martín‐González, M., & García‐Martín, J. M. (2022) · Nanoscale · doi:10.1039/d1nr06280h · Cited by 23
Recent advances in the analysis and control of large populations of neural oscillators
Wilson, D. D., & Moehlis, J. (2022) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2022.05.002 · Cited by 24
Spinal Cord Stimulation: Engineering Approaches to Clinical and Physiological Challenges
Moffitt, M. A., Lee, D. C., & Bradley, K. (2009) · Biological and medical physics series · doi:10.1007/978-0-387-77261-5_5 · Cited by 24
Zhou, Y., Bi, Z.-Y., Ji, M., Chen, S., Wang, W., Wang, K., Hu, B., Lü, X., & Wang, Z. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2980294 · Cited by 24
Does a coupling capacitor enhance the charge balance during neural stimulation? An empirical study
van Dongen, M. N., & Serdijn, W. A. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1312-9 · Cited by 23
Biodegradable stimulating electrodes for resident neural stem cell activation in vivo
Chen, T., Lau, K. S. K., Singh, A., Zhang, Y. X., Taromsari, S. M., Salari, M., Naguib, H. E., & Morshead, C. M. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2024.122957 · Cited by 24
Hobbs, T. G., Greenspon, C. M., Verbaarschot, C., Valle, G., Hughes, C. L., Boninger, M. L., Bensmaı̈a, S. J., & Gaunt, R. A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adc2d4 · Cited by 25
Potencial de ação: do estímulo à adaptação neural
Krueger, E., Scheeren, E. M., Neto, G. N. N., Button, V. L. D. S. N., Neves, E. B., & Nohama, P. (2011) · Fisioterapia em Movimento · doi:10.1590/s0103-51502011000300018 · Cited by 39
Methods for Specific Electrode Resistance Measurement During Transcranial Direct Current Stimulation
Khadka, N., Rahman, A., Sarantos, C. H., Truong, D. Q., & Bikson, M. (2014) · Brain stimulation · doi:10.1016/j.brs.2014.10.004 · Cited by 23
Self-citationJackson, N., & Stam, F. (2014) · Journal of Applied Polymer Science · doi:10.1002/app.41687 · Cited by 23
Su, S., Chai, G., Shu, X., Sheng, X., & Zhu, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5ee9 · Cited by 23
No functional TRPA1 in cardiomyocytes
Hoebart, C., Rojas‐Galvan, N. S., Ciotu, C. I., Aykac, I., Reissig, L. F., Weninger, W. J., Kiss, A., Podesser, B. K., Fischer, M. J. M., & Heber, S. (2021) · Acta Physiologica · doi:10.1111/apha.13659 · Cited by 23
Kwon, J., Lee, J. S., Lee, J.-J., Na, J., Sung, J., Lee, H., Kwak, H., Cheong, E., Cho, S., & Choi, H. (2021) · Nano Letters · doi:10.1021/acs.nanolett.0c04635 · Cited by 23
Chakraborty, B., Joshi‐Imre, A., & Cogan, S. F. (2021) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34906 · Cited by 24
In Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 25
Bielfeldt, M., Budde, K., Weis, N., Bünning, M., Staehlke, S., Zimmermann, J., Arbeiter, N., Mobini, S., González, M. U., Rebl, H., et al. (2023) · Journal of Biological Engineering · doi:10.1186/s13036-023-00393-1 · Cited by 23
Deciphering platinum dissolution in neural stimulation electrodes: Electrochemistry or biology?
Shah, D., Carter, P., Shivdasani, M. N., Fong, N., Duan, W., Esrafilzadeh, D., Poole-Warren, L. A., & Robles, U. A. A. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2024.122575 · Cited by 28
The Effects of Concentric Ring Electrode Electrical Stimulation on Rat Skin
Besio, W. G., Sharma, V., & Spaulding, J. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9891-y · Cited by 23
Safe direct current stimulator 2: Concept and design
Fridman, G. Y., & Santina, C. C. D. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610203 · Cited by 23
An Implantable Optical Stimulation Delivery System for Actuating an Excitable Biosubstrate
Paralikar, K. J., Cong, P., Yizhar, O., Fenno, L. E., Santa, W. A., Nielsen, C., Dinsmoor, D. A., Hocken, B., Munns, G. O., Giftakis, J., et al. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2074110 · Cited by 23
Electrical Impedance to Assess Facial Nerve Proximity During Robotic Cochlear Implantation
Ansó, J., Balmer, T. W., Jegge, Y., Kalvøy, H., Bell, B. J., Dür, C., Calvo, E. M., Williamson, T., Gerber, N., Ferrario, D., et al. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2830303 · Cited by 23
Khadka, N., Borges, H., Zannou, A. L., Jang, J., Kim, B., Lee, K.-W., & Bikson, M. (2018) · Brain stimulation · doi:10.1016/j.brs.2018.07.049 · Cited by 23
Self-citationSelf-supporting carbon nanotube films as flexible neural interfaces
Krukiewicz, K., Janas, D. W., Vallejo‐Giraldo, C., & Biggs, M. J. P. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.10.157 · Cited by 23
Krueger, E., Magri, L., Botelho, A. S., Bach, F. S., Rebellato, C. L. K., Fracaro, L., Fragoso, F. Y. I., Villanova, J. A., Brofman, P. R. S., & Popović‐Maneski, L. (2018) · Neuroscience Letters · doi:10.1016/j.neulet.2018.12.004 · Cited by 23
Khalifa, A., Zaeimbashi, M., Zhou, T. X., Abrishami, S. M. S., Sun, N., Park, S., Šumarac, T., Qu, J., Zohar, I., Yacoby, A., et al. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00320-8 · Cited by 23
Comparison of coil designs for peripheral magnetic muscle stimulation
Goetz, S. M., Herzog, H.-G., Gattinger, N., & Gleich, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056007 · Cited by 23
Biological–Machine Systems Integration: Engineering the Neural Interface
Lovell, N. H., Morley, J. W., Chen, S. C., Hallum, L. E., & Suaning, G. J. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2039030 · Cited by 23
Ackermann, D. M., Foldes, E. L., Bhadra, N., & Kilgore, K. L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332738 · Cited by 23
Piso, D., Veiga-Crespo, P., & Vecino, E. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322037 · Cited by 22
Abadijoo, H., Shakibi, R., Pouria, F. R., Manoochehri, N., Moharamipour, S., Hasanloo, M., Ghaderinia, M., Moosavi‐Movahedi, A. A., Abdolahad, M., & Khayamian, M. A. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.109157 · Cited by 23
Discrete Pattern of Burst Stimulation in the Ventrobasal Thalamus for Anti-Nociception
Huh, Y., & Cho, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067655 · Cited by 22
Biophysical Modeling for Brain Tissue Conductivity Estimation Using SEEG Electrodes
Carvallo, A., Modolo, J., Benquet, P., Lagarde, S., Bartoloméi, F., & Wendling, F. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2877931 · Cited by 22
Khadka, N., & Bikson, M. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abb7c1 · Cited by 22
Self-citationJiang, S., Song, J., Zhang, Y., Nie, M., Kim, J., Marcano, A. L., Kadlec, K. M., Mills, W. A., Yan, X., Liu, H., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c19187 · Cited by 20
Think big, see small—A review of nanomaterials for neural interfaces
Zeng, Q., Li, X., Zhang, S., Deng, C., & Wu, T. (2021) · Nano Select · doi:10.1002/nano.202100256 · Cited by 23
Schmidt, T., Jakešová, M., Đerek, V., Kornmueller, K., Tiapko, O., Bischof, H., Burgstaller, S., Waldherr, L., Nowakowska, M., Baumgärtner, C., et al. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202101159 · Cited by 24
The effects of electrical stimulation on glial cell behaviour
Tsui, C. T., Lal, P., Fox, K. V. R., Churchward, M. A., & Todd, K. G. (2022) · BMC Biomedical Engineering · doi:10.1186/s42490-022-00064-0 · Cited by 25
Mendes, A. X., do Nascimento, A. T., Duchi, S., Quigley, A. F., Aguilar, L. M. C., Dekiwadia, C. D., Kapsa, R. M. I., Silva, S. M., & Moulton, S. E. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb02387c · Cited by 22
State of the art: non-invasive electrical stimulation for the treatment of chronic tinnitus
Chen, S., Du, M., Wang, Y., Li, Y., Tong, B., Qiu, J., Wu, F., & Liu, Y. (2023) · Therapeutic Advances in Chronic Disease · doi:10.1177/20406223221148061 · Cited by 22
The future of brain–machine interfaces is optical
Ersaro, N. T., Yalcin, C., & Muller, R. (2023) · Nature Electronics · doi:10.1038/s41928-023-00926-y · Cited by 23
Flexible active electrode arrays with ASICs that fit inside the rat’s spinal canal
Giagka, V., Demosthenous, A., & Donaldson, N. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-0011-5 · Cited by 22
Extracellular matrix-based materials for neural interfacing
Chen, S., & Allen, M. G. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.120 · Cited by 23
Graded conducting titanium–iridium oxide coatings for bioelectrodes in neural systems
Cruz, A. M., & Casañ-Pastor, N. (2013) · Thin Solid Films · doi:10.1016/j.tsf.2013.02.031 · Cited by 22
Modification of surface/neuron interfaces for neural cell-type specific responses: a review
Chen, C., Kong, X., & Lee, I.-S. (2015) · Biomedical Materials · doi:10.1088/1748-6041/11/1/014108 · Cited by 22
Toward Adaptive Deep Brain Stimulation in Parkinson’s Disease: A Review
Mohammed, A., Bayford, R. H., & Demosthenous, A. (2018) · Neurodegenerative Disease Management · doi:10.2217/nmt-2017-0050 · Cited by 21
Zheng, Z., Huang, L., Yan, L., Yuan, F., Wang, L., Wang, K., Lawson, T., Lin, M., & Liu, Y. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20082013 · Cited by 22
Anderson, D. N., Anderson, C., Lanka, N., Sharma, R., Butson, C. R., Baker, B., & Dorval, A. D. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01152 · Cited by 22
Li, S., Alam, M., Ahmed, R. U., Zhong, H., Wang, X., Ng, S., & Zheng, Y. (2020) · Bioelectronic Medicine · doi:10.1186/s42234-020-00048-2 · Cited by 22
Chronic nerve health following implantation of femoral nerve cuff electrodes
Freeberg, M. J., Pinault, G. C. J., Tyler, D. J., Triolo, R. J., & Ansari, R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00720-3 · Cited by 22
A Goertzel Filter-Based System for Fast Simultaneous Multi-Frequency EIS
Regnacq, L., Wu, Y., Neshatvar, N., Jiang, D., & Demosthenous, A. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3092069 · Cited by 22
Malone, I. G., Nosacka, R. L., Nash, M. A., Otto, K. J., & Dale, E. A. (2021) · Journal of Neurophysiology · doi:10.1152/jn.00625.2020 · Cited by 25
Intensity Coding in Electric Hearing: Effects of Electrode Configurations and Stimulation Waveforms
Chua, T. E. H., Bachman, M., & Zeng, F. (2011) · Ear and Hearing · doi:10.1097/aud.0b013e31821a47df · Cited by 22
Practical considerations for the use of a Howland current source for neuro-stimulation
Pouliquen, P. O., Vogelstein, R. J., & Etienne‐Cummings, R. (2008) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2008.4696867 · Cited by 22
Design and fabrication of a multi-electrode array for spinal cord epidural stimulation
Chang, C.-W., Lo, Y., Gad, P. N., Edgerton, V. R., & Liu, W. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945198 · Cited by 20
Electrochemical Principles of Safe Charge Injection
Cogan, S. F., Garrett, D. J., & Green, R. A. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch3 · Cited by 24
Tessellation of artificial touch via microstimulation of human somatosensory cortexPreprint
Greenspon, C. M., Shelchkova, N. D., Valle, G., Hobbs, T. G., Berger-Wolf, E. I., Hutchison, B. C., Dogruoz, E., Verbaarschot, C., Callier, T., Sobinov, A. R., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.23.545425 · Cited by 22
Ghazavi, A., & Cogan, S. F. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9f31 · Cited by 21
Optogenetic stimulation: Understanding memory and treating deficits
Barnett, S. C., Perry, B. A. L., Dalrymple‐Alford, J. C., & Parr‐Brownlie, L. C. (2018) · Hippocampus · doi:10.1002/hipo.22960 · Cited by 23
Deep brain stimulation of the subthalamic nucleus for epilepsy
Yan, H., Ren, L., & Yu, T. (2022) · Acta Neurologica Scandinavica · doi:10.1111/ane.13707 · Cited by 21
Bringing new dimensions to drug discovery screening: impact of cellular stimulation technologies
Molokanova, E., Mercola, M. A., & Savchenko, A. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.01.015 · Cited by 21
Power amplifier circuits for functional electrical stimulation systems
de Souza, D. C., Gaiotto, M. D. C., Neto, G. N. N., Castro, M. C. F., & Nohama, P. (2017) · Research on Biomedical Engineering · doi:10.1590/2446-4740.07716 · Cited by 21
Krukiewicz, K., Kowalik, A., Czerwińska-Główka, D., & Biggs, M. J. P. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.02.023 · Cited by 21
Carpenter, C. W., Malinao, M. G., Rafeedi, T., Rodriquez, D., Tan, S. T. M., Root, N., Skelil, K., Ramírez, J., Polat, B., Root, S. E., et al. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201901119 · Cited by 21
Kosta, P., Mize, J. T., Warren, D. J., & Lazzi, G. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3038406 · Cited by 21
Eggers, T. E., Kilgore, J. A., Green, D., Vrabec, T. L., Kilgore, K. L., & Bhadra, N. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abebed · Cited by 21
Ullah, N., & Omanovic, S. (2015) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2015.03.061 · Cited by 21
Signal distortion from microelectrodes in clinical EEG acquisition systems
Stacey, W. C., Kellis, S., Patel, P. R., Greger, B. E., & Butson, C. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056007 · Cited by 21
Matter, L., Abdullaeva, O. S., Shaner, S. W., Leal, J., & Asplund, M. (2024) · Advanced Science · doi:10.1002/advs.202306244 · Cited by 21
neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications
Slater, K. D., Sinclair, N. C., Nelson, T. S., Blamey, P. J., & McDermott, H. J. (2015) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2015.2455507 · Cited by 22
Maciejasz, P., Badía, J., Boretius, T., Andreu, D., Stieglitz, T., Jensen, W., Navarro, X., & Guiraud, D. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1244-4 · Cited by 20
Wu, Y., Jiang, D., & Demosthenous, A. (2022) · UCL Discovery (University College London) · Cited by 20
Isaković, M. S., Malesevic, J. M., Kostic, M. D., Dosen, S. S., & Strbac, M. D. (2022) · IEEE Transactions on Haptics · doi:10.1109/toh.2022.3141187 · Cited by 23
Martínez, S., Veirano, F., Constandinou, T. G., & Silveira, F. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3228895 · Cited by 20
Transparent and Stretchable Au–Ag Nanowire Recording Microelectrode Arrays
Chen, Z., Nguyen, K., Kowalik, G., Shi, X., Tian, J., Doshi, M., Alber, B. R., Guan, X., Liu, X., Ning, X., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201716 · Cited by 20
Graphene-based cardiac sensors and actuators
Savchenko, A., Kireev, D., Yin, R. T., Efimov, I. R., & Molokanova, E. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1168667 · Cited by 20
Physical mechanisms of emerging neuromodulation modalities
Karatum, O., Han, M., Erdoğan, E. T., Karamürsel, S., & Nizamoğlu, S. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acd870 · Cited by 20
Matter, L., Harland, B. C., Raos, B. J., Svirskis, D. M., & Asplund, M. (2023) · APL Bioengineering · doi:10.1063/5.0152669 · Cited by 20
Wang, Z., Huang, Z., Lv, X., Zhou, Y., Wang, H., & Zong, S.-H. (2014) · Neural Regeneration Research · doi:10.4103/1673-5374.147938 · Cited by 20
Kim, B., Gutierrez, C. A., & Meng, E. F. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2420043 · Cited by 20
Selective Stimulation of the Spinal Cord Surface Using a Stretchable Microelectrode Array
Meacham, K., Guo, L., DeWeerth, S. P., & Hochman, S. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00005 · Cited by 20
Exploring the potential of ionic bipolar diodes for chemical neural interfaces
Tybrandt, K. (2017) · Soft Matter · doi:10.1039/c7sm01732d · Cited by 20
Vapor deposition of polyionic nanocoatings for reduction of microglia adhesion
Zhi, B., Song, Q., & Mao, Y. (2018) · RSC Advances · doi:10.1039/c7ra12728f · Cited by 20
A Carbon Slurry Separated Interface Nerve Electrode for Electrical Block of Nerve Conduction
Vrabec, T. L., Wainright, J. S., Bhadra, N., Shaw, L., Kilgore, K. L., & Bhadra, N. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2909165 · Cited by 20
A multiple modulation synthesis method with high spatial resolution for noninvasive neurostimulation
Xiao, Q., Zhong, Z., Lai, X., & Qin, H. (2019) · PLoS ONE · doi:10.1371/journal.pone.0218293 · Cited by 20
ReFaey, K., Chaichana, K. L., Feyissa, A. M., Vivas-Buitrago, T. G. M., Brinkmann, B. H., Middlebrooks, E. H., McKay, J. H., Lankford, D. J., Tripathi, S., Bojaxhi, E., et al. (2019) · Journal of neurosurgery · doi:10.3171/2019.4.jns19261 · Cited by 20
A Robust Encoding Scheme for Delivering Artificial Sensory Information via Direct Brain Stimulation
Bjånes, D. A., & Moritz, C. T. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2936739 · Cited by 20
GHz Ultrasonic Chip-Scale Device Induces Ion Channel Stimulation in Human Neural Cells
Balasubramanian, P. S., Singh, A., Xu, C., & Lal, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58133-0 · Cited by 21
Goetz, S. M., Howell, B. L., Wang, B., Li, Z., Sommer, M. A., Peterchev, A. V., & Grill, W. M. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.02.009 · Cited by 21
Ordelman, S. C. M. A., Kornet, L., Cornelussen, R. N., Buschman, H. P. J., & Veltink, P. H. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2214058 · Cited by 20
Negi, S., Bhandari, R., & Solzbacher, F. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347151 · Cited by 20
Kovach, K. M., Kumsa, D., Ali, A., Hudak, E. M., Untereker, D. F., Kelley, S. C., von Recum, H. A., & Capadona, J. R. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.07.018 · Cited by 19
Electrical stimulation of cells through photovoltaic microcell arrays
Vargas‐Estevez, C., Blanquer, A., Murillo, G., Duque, M., Barrios, L., Nogués, C., Ibáñez, E., & Estéve, J. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.07.012 · Cited by 19
Cisnal, A., Ihmig, F. R., Fraile, J. C., Turiel, J. P., & Muñoz-Martínez, V. F. (2019) · Sensors · doi:10.3390/s19122725 · Cited by 19
Yuan, Y., Zheng, L., Feng, Z., & Yang, G. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00862-y · Cited by 19
Balaguera, E. H. (2021) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2021.110768 · Cited by 19
Li, L., Jiang, C., & Li, L. (2021) · Bio-Design and Manufacturing · doi:10.1007/s42242-021-00160-5 · Cited by 19
MotiMove: Multi‐purpose transcutaneous functional electrical stimulator
Popović‐Maneski, L., & Mateo, S. (2022) · Artificial Organs · doi:10.1111/aor.14379 · Cited by 19
Neuronal Spiking Responses to Direct Electrical Microstimulation in the Human Cortex
Youssef, D., Wittig, J. H., Jackson, S. N., Inati, S. K., & Zaghloul, K. A. (2023) · Journal of Neuroscience · doi:10.1523/jneurosci.1666-22.2023 · Cited by 17
Biohybrid Soft Robots Powered by Myocyte: Current Progress and Future Perspectives
Yuan, Z., Guo, Q., Jin, D., Zhang, P., & Yang, W. (2023) · Micromachines · doi:10.3390/mi14081643 · Cited by 21
Metadata
- Authors
- Merrill, D. R., Bikson, M., & Jefferys, J. G. R.
- Affiliations
- University of Utah (US)
- City College of New York (US)
- University of Birmingham (GB)
- Corresponding author
- Merrill, Daniel R.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2005-02
- Volume
- 141
- Issue
- 2
- Pages
- 171-198
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2153787766
- Cited by
- 2,078
- References
- 159
- Citations by year
- 2026: 100 · 2025: 136 · 2024: 116 · 2023: 126 · 2022: 132 · 2021: 163 · 2020: 119 · 2019: 132 · 2018: 137 · 2017: 115 · 2016: 109 · 2015: 100 · 2014: 98 · 2013: 91 · 2012: 80
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Funders
- National Institutes of Health (5f32ns045454-03)
- National Institute of Neurological Disorders and Stroke (5F32NS045454)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- functional electrical stimulation, electrode-tissue interface, charge injection, Faradaic charge transfer, electrode potential, electrochemical reversibility, stimulation protocols, stimulation safety, tissue damage mechanisms, electrode damage, electrode materials
- MeSH terms
- Animals, Biomedical Engineering, Electric Stimulation, Electrochemistry, Electrodes, Electrolytes, Electrophysiology, Electric Stimulation Therapy, Equipment Design, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review