The DOI matches its Crossref record; 156 of the 159 references it cites were found in a registry or an index.
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Abstract
The physical basis for electrical stimulation of excitable tissue, as used by electrophysiological researchers and clinicians in functional electrical stimulation, is presented with emphasis on the fundamental mechanisms of charge injection at the electrode/tissue interface. Faradaic and non-Faradaic charge transfer mechanisms are presented and contrasted. An electrical model of the electrode/tissue interface is given. The physical basis for the origin of electrode potentials is given. Various methods of controlling charge delivery during pulsing are presented. Electrochemical reversibility is discussed. Commonly used electrode materials and stimulation protocols are reviewed in terms of stimulation efficacy and safety. Principles of stimulation of excitable tissue are reviewed with emphasis on efficacy and safety. Mechanisms of damage to tissue and the electrode are reviewed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, all data used in this study to fit and validate the model used symmetric, biphasic pulse trains, while other pulse shapes might lead to different neural or behavioral responses (Merrill et al., 2005).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Merrill et al., 2005
In the citing paper
“A critical aspect of electrical stimulation is its higher level of safety risk compared to recording electrical activity, which can result in both electrode and tissue damage.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [16]
In the citing paper
“Similarly, Merrill et al. noted that a narrow pulse is desirable to decrease occurrence of electrochemical reactions, and therefore reduce electrode degradation [2].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“In terms of electrode corrosion, however, slightly unbalanced biphasic pulses might be advantageous [2, 77].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“Charge injection at an electrode occurs through capacitive charge transfer, with no electron transfer across the electrodeelectrolyte interface, and Faradaic charge transfer, where electron transfer and reduction and oxidation (redox) reactions occur [101], [114].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“To minimise potentially toxic redox reaction products, biphasic stimulation reverses the charge injection in a second phase of a stimulation pulse aiming to reverse Faradaic reactions.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Faradaic reactions where products are not available for the reverse reaction are not reversed, for example hydrolysis of water or 'water window' which places safety limits on electrode-electrolyte interface potentials [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“In a biphasic pulse neuron activation occurs at a lower threshold for cathodic (sink) currents [101], [119], compared to positive anodic (source) currents.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Typical stimulation pulse widths range up to a few hundred μs , and current amplitudes vary from tens of μA to a few mA in peripheral nerve interfaces [9], [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Nitric oxide: physiology, pathophysiology, and pharmacology.
Moncada, S., Palmer, R. M., & Higgs, E. A. (1991) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06663-3 · Cited by 15,525
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,150
Bliss, T. V. P., & Gardner-Medwin, A. R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010274 · Cited by 7,424
Ionic channels of excitable membranes
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90172-7 · Cited by 7,134
Beckman, J. S., Beckman, T. W., Chen, J., Marshall, P. A., & Freeman, B. A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.4.1620 · Cited by 7,029
The Electrical Double Layer and the Theory of Electrocapillarity.
Grahame, D. C. (1947) · Chemical Reviews · doi:10.1021/cr60130a002 · Cited by 3,324
Inhibition of Cell Division in Escherichia coli by Electrolysis Products from a Platinum Electrode
Rosenberg, B., Camp, L. V., & Krigas, T. (1965) · Nature · doi:10.1038/205698a0 · Cited by 3,052
Reactive Oxygen Species and the Central Nervous System
Halliwell, B. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb10990.x · Cited by 2,947
(1981) · Handbook of exploration geochemistry · doi:10.1016/b978-0-444-41930-9.50014-3 · Cited by 2,903
Flagged first, then by citations
3 of the 159 references couldn’t be matched to a known paper.
Research works printed but not linked: 5
- Bhargava A. Long-term effects of quasi-trapezoidal pulses on the structure and function of sacral anterior roots. M.S. thesis, Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 1993.
- Guoy, 1910, Constitution of the electric charge at the surface of an electrolyte, J Physique, 9, 457
- Kennedy, 1999, Neural activity during acquisition of cursor control in a locked-in patient, Soc Neurosci Abstr, 25, 894
- Rall, 1977, vol.1/part 1
- Sevanian, 1988, Lipid peroxidation, membrane damage, and phospholipase A2 action: cellular antioxidant defense mechanisms, CRC Rev., II, 77
Cited by
Sorted by citations
Items 201–300 of 1,003
Activation of the central nervous system induced by micro-magnetic stimulation
Park, H.-J., Bonmassar, G., Kaltenbach, J. A., Machado, A. G., Manzoor, N. F., & Gale, J. T. (2013) · Nature Communications · doi:10.1038/ncomms3463 · Cited by 93
Goding, J. A., Gilmour, A. D., Robles, U. A. A., Hasan, E. A., & Green, R. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702969 · Cited by 94
Zhou, H., Cheng, X., Rao, L., Li, T., & Duan, Y. Y. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.01.042 · Cited by 93
Semiconductor Nanomembrane Tubes: Three-Dimensional Confinement for Controlled Neurite Outgrowth
Yu, M., Huang, Y., Ballweg, J., Shin, H.-C., Huang, M., Savage, D. E., Lagally, M. G., Dent, E. W., Blick, R. H., & Williams, J. C. (2011) · ACS Nano · doi:10.1021/nn103618d · Cited by 93
Iberite, F., Gruppioni, E., & Ricotti, L. (2022) · npj Regenerative Medicine · doi:10.1038/s41536-022-00216-9 · Cited by 99
Multifunctional Conductive Hydrogel Interface for Bioelectronic Recording and Stimulation
Tang, H., Li, Y., Liao, S., Liu, H., Qiao, Y., & Zhou, J. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202400562 · Cited by 91
Conducting polymers for neuronal microelectrode array recording and stimulation
Aqrawe, Z., Montgomery, J. M., Travaš‐Sejdić, J., & Svirskis, D. M. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.023 · Cited by 92
Nongenetic optical neuromodulation with silicon-based materials
Jiang, Y., Parameswaran, R., Li, X., Carvalho-de-Souza, J. L., Gao, X., Meng, L., Bezanilla, F., Shepherd, G. M., & Tian, B. (2019) · Nature Protocols · doi:10.1038/s41596-019-0135-9 · Cited by 87
Zaglia, T., Pianca, N., Borile, G., Broi, F. D., Richter, C., Campione, M., Lehnart, S. E., Luther, S., Corrado, D., Miquerol, L., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509380112 · Cited by 91
Surface-modified microelectrode array with flake nanostructure for neural recording and stimulation
Kim, J., Kang, G., Nam, Y., & Choi, Y. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/8/085303 · Cited by 96
Davidovics, N. S., Fridman, G. Y., Chiang, B., & Santina, C. C. D. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2065241 · Cited by 90
Gui, A. L., Luais, E., Peterson, J. R., & Gooding, J. J. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am400519m · Cited by 91
Eles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.043 · Cited by 86
Lu, Y., Liu, X., Hattori, R., Ren, C., Zhang, X., Komiyama, T., & Kuzum, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201800002 · Cited by 89
Bianchi, M., Salvo, A. D., Asplund, M., Carli, S., Lauro, M. D., Schulze‐Bonhage, A., Stieglitz, T., Fadiga, L., & Biscarini, F. (2022) · Advanced Science · doi:10.1002/advs.202104701 · Cited by 93
Cutaneous perception during tDCS: Role of electrode shape and sponge salinity
Minhas, P., Datta, A., & Bikson, M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.09.023 · Cited by 89
Self-citationStudying Network Mechanisms Using Intracranial Stimulation in Epileptic Patients
Olivier David, A., Bastin, J., Chabardès, S., Minotti, L., & Kahane, P. (2010) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2010.00148 · Cited by 102
Anatomical Parameters of tDCS to Modulate the Motor System after Stroke: A Review
Lefebvre, S., & Liew, S. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00029 · Cited by 95
Nicolai, E. N., Settell, M. L., Knudsen, B. E., McConico, A. L., Gosink, B. A., Trevathan, J. K., Baumgart, I. W., Ross, E. K., Pelot, N. A., Grill, W. M., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9db8 · Cited by 82
Cogan, S. F., Troyk, P. R., Ehrlich, J., Gasbarro, C. M., & Plante, T. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/008 · Cited by 88
Joucla, S., & Yvert, B. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.10.003 · Cited by 96
Safety considerations for deep brain stimulation: review and analysis
Grill, W. M. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.4.409 · Cited by 88
Guiraud, D., Andreu, D., Bonnet, S., Carrault, G., Couderc, P., Hagège, A. A., Henry, C., Hernandez, A. I., Karam, N., Rolle, V. L., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/041002 · Cited by 93
A Novel Model Incorporating Two Variability Sources for Describing Motor Evoked Potentials
Goetz, S. M., Luber, B. M., Lisanby, S. H., & Peterchev, A. V. (2014) · Brain stimulation · doi:10.1016/j.brs.2014.03.002 · Cited by 87
Tissue-Compliant Neural Implants from Microfabricated Carbon Nanotube Multilayer Composite
Zhang, H., Patel, P. R., Xie, Z., Swanson, S. D., Wang, X., & Kotov, N. A. (2013) · ACS Nano · doi:10.1021/nn402074y · Cited by 88
Achieving long-term stability of thin-film electrodes for neurostimulation
Oldroyd, P., & Malliaras, G. G. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.05.004 · Cited by 91
Electrode Materials for Chronic Electrical Microstimulation
Zheng, X. S., Tan, C., Castagnola, E., & Cui, X. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100119 · Cited by 90
VNS parameters for clinical response in Epilepsy
Fahoum, F., Boffini, M., Kann, L., Faini, S., Gordon, C., Tzadok, M., & Tahry, R. E. (2022) · Brain stimulation · doi:10.1016/j.brs.2022.05.016 · Cited by 86
Direct laser writing of 3D electrodes on flexible substrates
Brown, M. A., Zappitelli, K. M., Singh, L., Yuan, R., Bemrose, M. A., Brogden, V., Miller, D. J., Smear, M. C., Cogan, S. F., & Gardner, T. J. (2023) · Nature Communications · doi:10.1038/s41467-023-39152-7 · Cited by 90
Palm, U., Feichtner, K., Hasan, A., Gauglitz, G. G., Langguth, B., Nitsche, M. A., Keeser, D., & Padberg, F. (2014) · Brain stimulation · doi:10.1016/j.brs.2014.06.006 · Cited by 85
Merkow, M. B., Burke, J. F., Ramayya, A. G., Sharan, A. D., Sperling, M. R., & Kahana, M. J. (2016) · Brain stimulation · doi:10.1016/j.brs.2016.12.011 · Cited by 85
Zhao, J., Chen, X. M., Liang, B. D., & Chen, Q. X. (2017) · Wireless Communications and Mobile Computing · doi:10.1155/2017/5842310 · Cited by 85
Transcranial electric and magnetic stimulation
Paulus, W., Peterchev, A. V., & Ridding, M. C. (2013) · Handbook of clinical neurology · doi:10.1016/b978-0-444-53497-2.00027-9 · Cited by 91
A High-Voltage-Tolerant and Precise Charge-Balanced Neuro-Stimulator in Low Voltage CMOS Process
Luo, Z., & Ker, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2512443 · Cited by 84
Silicon-Integrated High-Density Electrocortical Interfaces
Ha, S., Akinin, A., Park, J., Kim, C., Wang, H., Maier, C., Mercier, P. P., & Cauwenberghs, G. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2587690 · Cited by 84
Raspopović, S., Petrini, F. M., Żelechowski, M., & Valle, G. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2600560 · Cited by 84
Michelson, N. J., Eles, J. R., Vazquez, A. L., Ludwig, K. A., & Kozai, T. D. Y. (2018) · Journal of Neuroscience Research · doi:10.1002/jnr.24370 · Cited by 85
Influence of PEDOT:PSS Coating Thickness on the Performance of Stimulation Electrodes
Dijk, G., Ruigrok, H. J., & O'Connor, R. P. (2020) · Advanced Materials Interfaces · doi:10.1002/admi.202000675 · Cited by 84
Wireless, battery-free, and fully implantable electrical neurostimulation in freely moving rodents
Burton, A., Won, S. M., Sohrabi, A. K., Stuart, T., Azami, A., Kim, J. U., Park, Y., Gabros, A. D., Rogers, J. A., Vitale, F., et al. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00294-7 · Cited by 84
Cruz, A. M., Abad, L., Carretero, N. M., Moral‐Vico, J., Fraxedas, J., Lozano, P., Subías, G., Padial, V., Carballo, M., Collazos-Castro, J. E., et al. (2012) · The Journal of Physical Chemistry C · doi:10.1021/jp212275q · Cited by 85
Auditory Midbrain Implant: A Review
Lim, H. H., Lenarz, M., & Lenarz, T. (2009) · Trends in Amplification · doi:10.1177/1084713809348372 · Cited by 87
High-Resolution Multi-Scale Computational Model for Non-Invasive Cervical Vagus Nerve Stimulation
Mourdoukoutas, A. P., Truong, D. Q., Adair, D., Simon, B. J., & Bikson, M. (2017) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12706 · Cited by 86
Self-citationYa, L., Qi, Z., Yang, J., Zhou, M., Zhang, X., Ling, W., Zhang, Y., Wu, Z., Wang, H., Ning, B., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201904977 · Cited by 83
Electric field stimulation for tissue engineering applications
Ryan, C. N. M., Doulgkeroglou, M.-N., & Zeugolis, D. I. (2021) · BMC Biomedical Engineering · doi:10.1186/s42490-020-00046-0 · Cited by 83
Toward More Versatile and Intuitive Cortical Brain–Machine Interfaces
Andersen, R. A., Kellis, S., Klaes, C., & Aflalo, T. (2014) · Current Biology · doi:10.1016/j.cub.2014.07.068 · Cited by 83
Petrossians, A., Whalen, J. J., Weiland, J. D., & Mansfeld, F. B. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3559477 · Cited by 83
Pulsatile desynchronizing delayed feedback for closed-loop deep brain stimulation
Popovych, O. V., Lysyansky, B., Rosenblum, M., PIKOVSKY, A. S., & Tass, P. A. (2017) · PLoS ONE · doi:10.1371/journal.pone.0173363 · Cited by 81
Caldwell, D. J., Ojemann, J. G., & Rao, R. P. N. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00804 · Cited by 83
The development of neural stimulators: a review of preclinical safety and efficacy studies
Shepherd, R. K., Villalobos, J., Burns, O., & Nayagam, D. A. X. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac43c · Cited by 83
Improving Cochlear Implant Properties Through Conductive Hydrogel Coatings
Hassarati, R. T., Dueck, W. F., Tasche, C., Carter, P. M., Poole-Warren, L. A., & Green, R. A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2304559 · Cited by 81
The Rationale Driving the Evolution of Deep Brain Stimulation to Constant-Current Devices
Bronstein, J. M., Tagliati, M., McIntyre, C. C., Chen, R. E., Cheung, T., Hargreaves, E. L., Israel, Z. H., Moffitt, M. A., Montgomery, E. B., Stypulkowski, P. H., et al. (2014) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12227 · Cited by 81
Electro-optical Neural Platform Integrated with Nanoplasmonic Inhibition Interface
Yoo, S., Kim, R., Park, J., & Nam, Y. (2016) · ACS Nano · doi:10.1021/acsnano.5b07747 · Cited by 80
Closed-Loop Neuromodulation in Physiological and Translational ResearchPreprint
Zanos, S. P. (2018) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a034314 · Cited by 89
Modified Pulse Shapes for Effective Neural Stimulation
Hofmann, L., Ebert, M., Tass, P. A., & Hauptmann, C. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00009 · Cited by 80
Retinal Neurostimulator for a Multifocal Vision Prosthesis
Wong, Y. T., Dommel, N., Preston, P., Hallum, L. E., Lehmann, T., Lovell, N. H., & Suaning, G. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903958 · Cited by 79
Generalized framework for stimulus artifact removal.
Erez, Y., Tischler, H., Moran, A., & Bar-Gad, I. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.06.005 · Cited by 79
Samba, R., Herrmann, T., & Zeck, G. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016014 · Cited by 79
Chang, Y.-C., Cracchiolo, M., Ahmed, U., Mughrabi, I. T., Gabalski, A. H., Daytz, A. E., Rieth, L. W., Becker, L. B., Datta, T., Al‐Abed, Y., et al. (2020) · Brain stimulation · doi:10.1016/j.brs.2020.09.002 · Cited by 79
Electrical stimulation of titanium to promote stem cell orientation, elongation and osteogenesis
Khaw, J. S., Xue, R., Cassidy, N. J., & Cartmell, S. H. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.08.010 · Cited by 79
Carbon-based neural electrodes: promises and challenges
Devi, M., Vomero, M., Fuhrer, E., Castagnola, E., Gueli, C., Nimbalkar, S., Hirabayashi, M., Kassegne, S., Stieglitz, T., & Sharma, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1e45 · Cited by 82
Feddersen, B., Vercueil, L., Noachtar, S., Olivier David, A., Depaulis, A., & Deransart, C. (2007) · Neurobiology of Disease · doi:10.1016/j.nbd.2007.05.005 · Cited by 79
Nanoporous Pt Microelectrode for Neural Stimulation and Recording: In Vitro Characterization
Park, S., Song, Y. J., Boo, H., & Chung, T. D. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp911256h · Cited by 79
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Fong, A. J., Roy, R. R., Ichiyama, R. M., Lavrov, I. A., Courtine, G., Gerasimenko, Y., Tai, Y. C., Burdick, J. W., & Edgerton, V. R. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17526-x · Cited by 78
Connectivity of the human insula: A cortico-cortical evoked potential (CCEP) study
Dionisio, S. A., Mayoglou, L., Cho, S., Prime, D., Flanigan, P. M., Lega, B. C., Mosher, J. C., Leahy, R. M., Gonzalez-Martinez, J. A., & Nair, D. R. (2019) · Cortex · doi:10.1016/j.cortex.2019.05.019 · Cited by 80
Layered Nanocomposites from Gold Nanoparticles for Neural Prosthetic Devices
Zhang, H., Shih, J., Zhu, J. G., & Kotov, N. A. (2012) · Nano Letters · doi:10.1021/nl3015632 · Cited by 78
Ramirez‐Zamora, A., Giordano, J. J., Gunduz, A., Brown, P., Sanchez, J. C., Foote, K. D., Almeida, L., Starr, P. A., Bronte-Stewart, H. M., Hu, W., et al. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00734 · Cited by 80
A New Implantable Closed-Loop Clinical Neural Interface: First Application in Parkinson’s Disease
Arlotti, M., Colombo, M., Bonfanti, A. G., Mandat, T. S., Lanotte, M., Pirola, E., Borellini, L., Rampini, P. M., Eleopra, R., Rinaldo, S., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.763235 · Cited by 77
Laser patterning of platinum electrodes for safe neurostimulation
Green, R. A., Matteucci, P. B., Dodds, C. W. D., Palmer, J., Dueck, W. F., Hassarati, R. T., Byrnes-Preston, P., Lovell, N. H., & Suaning, G. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056017 · Cited by 77
MEMS: Enabled Drug Delivery Systems
Cobo, A., Sheybani, R., & Meng, E. F. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400772 · Cited by 77
Fridman, G. Y., Davidovics, N. S., Dai, C., Migliaccio, A. A., & Santina, C. C. D. (2010) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-010-0208-5 · Cited by 77
Martin, D. C. (2015) · MRS Communications · doi:10.1557/mrc.2015.17 · Cited by 79
Combined optical and electrical stimulation of neural tissue in vivo
Duke, A. R., Cayce, J. M., Malphrus, J. D., Konrad, P., Mahadevan-Jansen, A., & Jansen, E. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3257230 · Cited by 76
Sun, Y.-S., Peng, S.-W., & Cheng, J. (2012) · Biomicrofluidics · doi:10.1063/1.4750486 · Cited by 75
Nanobionics: the impact of nanotechnology on implantable medical bionic devices
Wallace, G. G., Higgins, M. J., Moulton, S. E., & Wang, C. (2012) · Nanoscale · doi:10.1039/c2nr30758h · Cited by 75
Superior Electrochemical Performance of Carbon Nanotubes Directly Grown on Sharp Microelectrodes
Ansaldo, A., Castagnola, E., Maggiolini, E., Fadiga, L., & Ricci, D. (2011) · ACS Nano · doi:10.1021/nn103445d · Cited by 75
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Hartmann, C. J., Luján, J. L., Chaturvedi, A., Goodman, W. K., Okun, M. S., McIntyre, C. C., & Haq, I. U. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00519 · Cited by 75
Muscle contractions and pain sensation accompanying high-frequency electroporation pulses
Cvetkoska, A., Maček-Lebar, A., Trdina, P., Damijan Miklavčič, A., & Reberšek, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-12112-9 · Cited by 74
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
Prime, D., Rowlands, D. D., O’Keefe, S. G., & Dionisio, S. A. (2017) · Epilepsia · doi:10.1111/epi.13939 · Cited by 75
Lai, H.-Y., Younce, J. R., Albaugh, D. L., Kao, Y. J., & Shih, Y. I. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.026 · Cited by 71
Pu, H., Malekzadeh-Arasteh, O., Danesh, A. R., Nenadić, Z., Do, A. H., & Heydari, P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3108578 · Cited by 72
Integrated Sensors for Soft Medical Robotics
Qiu, Y., Ashok, A., Nguyen, C. C., Yamauchi, Y., Do, T. N., & Phan, H. (2024) · Small · doi:10.1002/smll.202308805 · Cited by 74
Novel interfaces for light directed neuronal stimulation: advances and challenges
Bareket, L., & Hanein, Y. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s51193 · Cited by 74
In Vivo and In Vitro Comparison of the Charge Injection Capacity of Platinum Macroelectrodes
Leung, R. T., Shivdasani, M. N., Nayagam, D. A. X., & Shepherd, R. K. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2366514 · Cited by 74
Exponential Current Pulse Generation for Efficient Very High-Impedance Multisite Stimulation
Ethier, S., & Sawan, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2073707 · Cited by 71
Neural and electromyography PEDOT electrodes for invasive stimulation and recording
Rossetti, N., Hagler, J., Kateb, P., & Cicoira, F. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc00625h · Cited by 72
Attaining higher resolution visual prosthetics: a review of the factors and limitations
Eiber, C. D., Lovell, N. H., & Suaning, G. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/011002 · Cited by 71
Development of bioactive conducting polymers for neural interfaces
Poole-Warren, L. A., Lovell, N. H., Baek, S., & Green, R. A. (2009) · Expert Review of Medical Devices · doi:10.1586/erd.09.58 · Cited by 71
Butz, N., Taschwer, A., Nessler, S., Manoli, Y., & Kuhl, M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2828823 · Cited by 70
Neural responses to electrical stimulation in 2D and 3D in vitro environments
Bertucci, C., Koppes, R. A., Dumont, C. M., & Koppes, A. N. (2019) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2019.07.016 · Cited by 71
Vagus Nerve Stimulation in Rodent Models: An Overview of Technical Considerations
Noller, C. M., Levine, Y. A., Urakov, T. M., Aronson, J. P., & Nash, M. S. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00911 · Cited by 70
Zhang, Y., Friec, A. L., Zhang, Z., Müller, C., Du, T., Dong, M., Liu, Y., & Chen, M. (2023) · Materials Today · doi:10.1016/j.mattod.2023.09.005 · Cited by 75
Young, A. T., Cornwell, N., & Daniele, M. A.-A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700239 · Cited by 71
Optimal Chaotic Desynchronization for Neural Populations
Wilson, D. D., & Moehlis, J. (2014) · SIAM Journal on Applied Dynamical Systems · doi:10.1137/120901702 · Cited by 69
Safety Ensuring Retinal Prosthesis With Precise Charge Balance and Low Power Consumption
Chun, H., Yang, Y., & Lehmann, T. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2257171 · Cited by 68
Bioreactors for Cardiac Tissue Engineering
Paez‐Mayorga, J., Hernández‐Vargas, G., Ruiz‐Esparza, G. U., Iqbal, H. M. N., Wang, X., Zhang, Y. S., Parra‐Saldívar, R., & Khademhosseini, A. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701504 · Cited by 68
Ackermann, D. M., Bhadra, N., Foldes, E. L., & Kilgore, K. L. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0679-x · Cited by 68
Hahn, C., Rice, J., Macuff, S., Minhas, P., Rahman, A., & Bikson, M. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.07.028 · Cited by 69
Self-citation
Metadata
- Authors
- Merrill, D. R., Bikson, M., & Jefferys, J. G. R.
- Affiliations
- University of Utah (US)
- City College of New York (US)
- University of Birmingham (GB)
- Corresponding author
- Merrill, Daniel R.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2005-02
- Volume
- 141
- Issue
- 2
- Pages
- 171-198
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2153787766
- Cited by
- 2,078
- References
- 159
- Citations by year
- 2026: 100 · 2025: 136 · 2024: 116 · 2023: 126 · 2022: 132 · 2021: 163 · 2020: 119 · 2019: 132 · 2018: 137 · 2017: 115 · 2016: 109 · 2015: 100 · 2014: 98 · 2013: 91 · 2012: 80
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Funders
- National Institutes of Health (5f32ns045454-03)
- National Institute of Neurological Disorders and Stroke (5F32NS045454)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- functional electrical stimulation, electrode-tissue interface, charge injection, Faradaic charge transfer, electrode potential, electrochemical reversibility, stimulation protocols, stimulation safety, tissue damage mechanisms, electrode damage, electrode materials
- MeSH terms
- Animals, Biomedical Engineering, Electric Stimulation, Electrochemistry, Electrodes, Electrolytes, Electrophysiology, Electric Stimulation Therapy, Equipment Design, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review