Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Abstract
The physical basis for electrical stimulation of excitable tissue, as used by electrophysiological researchers and clinicians in functional electrical stimulation, is presented with emphasis on the fundamental mechanisms of charge injection at the electrode/tissue interface. Faradaic and non-Faradaic charge transfer mechanisms are presented and contrasted. An electrical model of the electrode/tissue interface is given. The physical basis for the origin of electrode potentials is given. Various methods of controlling charge delivery during pulsing are presented. Electrochemical reversibility is discussed. Commonly used electrode materials and stimulation protocols are reviewed in terms of stimulation efficacy and safety. Principles of stimulation of excitable tissue are reviewed with emphasis on efficacy and safety. Mechanisms of damage to tissue and the electrode are reviewed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, all data used in this study to fit and validate the model used symmetric, biphasic pulse trains, while other pulse shapes might lead to different neural or behavioral responses (Merrill et al., 2005).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Merrill et al., 2005
In the citing paper
“A critical aspect of electrical stimulation is its higher level of safety risk compared to recording electrical activity, which can result in both electrode and tissue damage.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [16]
In the citing paper
“Similarly, Merrill et al. noted that a narrow pulse is desirable to decrease occurrence of electrochemical reactions, and therefore reduce electrode degradation [2].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“In terms of electrode corrosion, however, slightly unbalanced biphasic pulses might be advantageous [2, 77].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“Charge injection at an electrode occurs through capacitive charge transfer, with no electron transfer across the electrodeelectrolyte interface, and Faradaic charge transfer, where electron transfer and reduction and oxidation (redox) reactions occur [101], [114].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“To minimise potentially toxic redox reaction products, biphasic stimulation reverses the charge injection in a second phase of a stimulation pulse aiming to reverse Faradaic reactions.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Faradaic reactions where products are not available for the reverse reaction are not reversed, for example hydrolysis of water or 'water window' which places safety limits on electrode-electrolyte interface potentials [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“In a biphasic pulse neuron activation occurs at a lower threshold for cathodic (sink) currents [101], [119], compared to positive anodic (source) currents.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Typical stimulation pulse widths range up to a few hundred μs , and current amplitudes vary from tens of μA to a few mA in peripheral nerve interfaces [9], [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Nitric oxide: physiology, pathophysiology, and pharmacology.
Moncada, S., Palmer, R. M., & Higgs, E. A. (1991) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06663-3 · Cited by 15,525
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,150
Bliss, T. V. P., & Gardner-Medwin, A. R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010274 · Cited by 7,424
Ionic channels of excitable membranes
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90172-7 · Cited by 7,134
Beckman, J. S., Beckman, T. W., Chen, J., Marshall, P. A., & Freeman, B. A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.4.1620 · Cited by 7,029
The Electrical Double Layer and the Theory of Electrocapillarity.
Grahame, D. C. (1947) · Chemical Reviews · doi:10.1021/cr60130a002 · Cited by 3,324
Inhibition of Cell Division in Escherichia coli by Electrolysis Products from a Platinum Electrode
Rosenberg, B., Camp, L. V., & Krigas, T. (1965) · Nature · doi:10.1038/205698a0 · Cited by 3,052
Reactive Oxygen Species and the Central Nervous System
Halliwell, B. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb10990.x · Cited by 2,947
(1981) · Handbook of exploration geochemistry · doi:10.1016/b978-0-444-41930-9.50014-3 · Cited by 2,903
Flagged first, then by citations
3 of the 159 references couldn’t be matched to a known paper.
Research works printed but not linked: 5
- Bhargava A. Long-term effects of quasi-trapezoidal pulses on the structure and function of sacral anterior roots. M.S. thesis, Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 1993.
- Guoy, 1910, Constitution of the electric charge at the surface of an electrolyte, J Physique, 9, 457
- Kennedy, 1999, Neural activity during acquisition of cursor control in a locked-in patient, Soc Neurosci Abstr, 25, 894
- Rall, 1977, vol.1/part 1
- Sevanian, 1988, Lipid peroxidation, membrane damage, and phospholipase A2 action: cellular antioxidant defense mechanisms, CRC Rev., II, 77
Cited by
Sorted by citations
Items 301–400 of 1,003
Heim, M., Yvert, B., & Kuhn, A. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.10.001 · Cited by 72
Du, Z. J., Luo, X., Weaver, C. L., & Cui, X. T. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00145e · Cited by 70
Gastric Electrical Stimulation for Gastroparesis
Brody, F. J., Vaziri, K., Saddler, A., Ali, A. M., Drenon, E., Hanna, B., Akin, E. A., Gonzalez, F., & Soffer, E. (2008) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2008.04.032 · Cited by 68
Anderson, C. J., Anderson, D. N., Pulst, S. M., Butson, C. R., & Dorval, A. D. (2020) · Brain stimulation · doi:10.1016/j.brs.2020.03.017 · Cited by 68
Hottowy, P., Skoczeń, A., Gunning, D. E., Kachiguine, S., Mathieson, K., Sher, A., Wiącek, P., Litke, A. M., & Dąbrowski, W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066005 · Cited by 67
Li, J., Liu, X., Crook, J. M., & Wallace, G. G. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110312 · Cited by 67
Yousif, N., Bayford, R. H., & Liu, X. (2008) · Neuroscience · doi:10.1016/j.neuroscience.2008.07.051 · Cited by 67
Soffer, E. E., Abell, T. L., LIN, Z., Lorincz, A., McCallum, R. W., Parkman, H. P., Policker, S., & ORDOG, T. (2009) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2009.04082.x · Cited by 67
Modeling sequence and quasi-uniform assumption in computational neurostimulation
Bikson, M., Truong, D. Q., Mourdoukoutas, A. P., Aboseria, M., Khadka, N., Adair, D., & Rahman, A. (2015) · Progress in brain research · doi:10.1016/bs.pbr.2015.08.005 · Cited by 67
Self-citationTektürk, P., Erdoğan, E. T., Kurt, A., Vanlı-Yavuz, E. N., Ekizoğlu, E., Kocagöncü, E., Kucuk, Z., Aksu, S., Bebek, N., Yapıcı, Z., et al. (2016) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2016.07.014 · Cited by 67
Increased functional connectivity one week after motor learning and tDCS in stroke patients
Lefebvre, S., Dricot, L., Laloux, P., Desfontaines, P., Evrard, F., Peeters, A. P., Jamart, J., & Vandermeeren, Y. (2016) · Neuroscience · doi:10.1016/j.neuroscience.2016.10.066 · Cited by 67
Optogenetic versus Electrical Stimulation of Human Cardiomyocytes: Modeling Insights
Williams, J. C., & Entcheva, E. G. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.03.032 · Cited by 66
Lee, S., Eom, T., Kim, M. K., Yang, S., & Shim, B. S. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.04.099 · Cited by 69
An Experimental Study of Voltage, Current, and Charge Controlled Stimulation Front-End Circuitry
Simpson, J. A., & Ghovanloo, M. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378401 · Cited by 66
Conductively coupled flexible silicon electronic systems for chronic neural electrophysiology
Li, J., Song, E., Chiang, C.-H., Yu, K. J., Koo, J., Du, H., Zhong, Y., Hill, M., Wang, C., Zhang, J., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813187115 · Cited by 65
Implantable Direct Current Neural Modulation: Theory, Feasibility, and Efficacy
Aplin, F. P., & Fridman, G. Y. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00379 · Cited by 66
Turi, Z., Ambrus, G. G., Ho, K.-A., Sengupta, T., Paulus, W., & Antal, A. (2014) · Brain stimulation · doi:10.1016/j.brs.2014.01.059 · Cited by 65
Gastric Electrical Stimulation for Gastroparesis
Soffer, E. (2012) · Journal of Neurogastroenterology and Motility · doi:10.5056/jnm.2012.18.2.131 · Cited by 65
Donos, C., Mı̂ndruță, I., Ciurea, J., Mălîia, M. D., & Barborică, A. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.02.013 · Cited by 66
Zeng, Q., Xia, K., Sun, B., Yin, Y., Wu, T., & Humayun, M. S. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.03.213 · Cited by 65
Transcranial Electrical Stimulation
Moreno‐Duarte, I., Gebodh, N., Schestatsky, P., Guleyupoglu, B., Reato, D., Bikson, M., & Fregni, F. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-404704-4.00002-8 · Cited by 75
Self-citationAnsó, J., Benjaber, M., Parks, B. A., Parker, S. R., Oehrn, C. R., Petrucci, M. N., Gilron, R., Little, S. J., Wilt, R., Bronte-Stewart, H. M., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a3 · Cited by 64
Bikson, M., Bulow, P., Stiller, J. W., Datta, A., Battaglia, F., Karnup, S. V., & Postolache, T. T. (2008) · Current Treatment Options in Neurology · doi:10.1007/s11940-008-0040-y · Cited by 65
Self-citationVillamar, M. F., Volz, M. S., Bikson, M., Datta, A., DaSilva, A. F. M., & Fregni, F. (2013) · Journal of Visualized Experiments · doi:10.3791/50309-v · Cited by 64
Self-citationNeural Interfaces at The Nanoscale
Pancrazio, J. J. (2008) · Nanomedicine · doi:10.2217/17435889.3.6.823 · Cited by 64
Cassar, I. R., Yu, C., Sambangi, J., Lee, C. D., Whalen, J. J., Petrossians, A., & Grill, W. M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.017 · Cited by 63
Higgins, S. G., Fiego, A. L., Patrick, I., Creamer, A., & Stevens, M. M. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000384 · Cited by 64
An Injectable Neural Stimulation Electrode Made from an In‐Body Curing Polymer/Metal Composite
Trevathan, J. K., Baumgart, I. W., Nicolai, E. N., Gosink, B. A., Asp, A. J., Settell, M. L., Polaconda, S. R., Malerick, K. D., Brodnick, S. K., Zeng, W., et al. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900892 · Cited by 64
Gori, M., Vadalà, G., Giannitelli, S. M., Denaro, V., & Pino, G. D. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.659033 · Cited by 67
The Autonomous Pipeline Navigation of a Cockroach Bio-Robot with Enhanced Walking Stimuli
Ma, S., Chen, Y., Yang, S., Liu, S., Tang, L., Li, B., & Li, Y. (2023) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0067 · Cited by 62
Hernández-Labrado, G. R., Polo, J. L., López‐Dolado, E., & Collazos-Castro, J. E. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0756-9 · Cited by 62
Short and long term biocompatibility of NeuroProbes silicon probes
Grand, L., Wittner, L., Herwik, S., Göthelid, E., Ruther, P., Oscarsson, S. O., Neves, H. P., Dombovári, B., Csercsa, R., Karmos, G., et al. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.009 · Cited by 64
Temporal pattern of electrical stimulation is a new dimension of therapeutic innovation
Grill, W. M. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.08.007 · Cited by 61
Foldes, E. L., Ackermann, D. M., Bhadra, N., Kilgore, K. L., & Bhadra, N. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.020 · Cited by 61
Shepherd, R. K., Carter, P., Dalrymple, A. N., Enke, Y. L., Wise, A. K., Nguyen, T. V., Firth, J., Thompson, A., & Fallon, J. B. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe5ba · Cited by 69
Electrical stimulation for therapeutic approach
Kim, E., Kim, S., Kwon, Y. W., Seo, H., Kim, M., Chung, W. G., Park, W., Song, H., Lee, D. H., Lee, J., et al. (2023) · Interdisciplinary medicine · doi:10.1002/inmd.20230003 · Cited by 66
Fridman, G. Y., & Santina, C. C. D. (2012) · The Anatomical Record · doi:10.1002/ar.22581 · Cited by 61
Analysis of high-perimeter planar electrodes for efficient neural stimulation
Wei, X. F. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.015.2009 · Cited by 63
Optogenetic pacing in Drosophila melanogaster
Alex, A., Li, A., Tanzi, R. E., & Zhou, C. (2015) · Science Advances · doi:10.1126/sciadv.1500639 · Cited by 64
Elwassif, M. M., Datta, A., Rahman, A., & Bikson, M. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046009 · Cited by 61
Self-citationCompliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“Electrical stimulation also contributes to the degradation of metallic electrodes, as non-reversible electrochemical reactions may occur when injecting high currents [88, 89].”
BackgroundThinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60
The appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60
RuO 2 Supercapacitor Enables Flexible, Safe, and Efficient Optoelectronic Neural Interface
Karatum, O., Yıldız, E., Kaleli, H. N., Şahin, A., Ülgüt, B., & Nizamoğlu, S. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202109365 · Cited by 60
Organic Bionics: A New Dimension in Neural Communications
Moulton, S. E., Higgins, M. J., Kapsa, R. M. I., & Wallace, G. G. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201102232 · Cited by 60
Vertical electric field stimulated neural cell functionality on porous amorphous carbon electrodes
Jain, S., Sharma, A., & Basu, B. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.08.057 · Cited by 58
Approaches to closed-loop deep brain stimulation for movement disorders
Kuo, C., White-Dzuro, G. A., & Ko, A. L. (2018) · Neurosurgical FOCUS · doi:10.3171/2018.5.focus18173 · Cited by 60
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Weremfo, A., Carter, P., Hibbert, D. B., & Zhao, C. (2015) · Langmuir · doi:10.1021/la504876n · Cited by 59
Bangera, N. B., Schomer, D. L., Dehghani, N., Ulbert, I., Cash, S. S., Papavasiliou, S., Eisenberg, S. R., Dale, A. M., & Halgren, E. (2010) · Journal of Computational Neuroscience · doi:10.1007/s10827-009-0205-z · Cited by 59
An Ultralightweight and Living Legged Robot
Vo‐Doan, T. T., Tan, M. Y. W., Bui, X. H., & Sato, H. (2017) · Soft Robotics · doi:10.1089/soro.2017.0038 · Cited by 59
Flexible and Organic Neural Interfaces: A Review
Lago, N., & Cester, A. (2017) · Applied Sciences · doi:10.3390/app7121292 · Cited by 63
Advances in Conducting, Biodegradable and Biocompatible Copolymers for Biomedical Applications
Silva, A. C. D., & de Torresi, S. I. C. (2019) · Frontiers in Materials · doi:10.3389/fmats.2019.00098 · Cited by 61
Li, J., Zhang, L., Yu, L., Minami, I., Miyagawa, S., Hörning, M., Dong, J., Qiao, J., Qu, X., Hua, Y., et al. (2020) · Communications Biology · doi:10.1038/s42003-020-0853-0 · Cited by 57
Ga‐Based Liquid Metals: Versatile and Biocompatible Solutions for Next‐Generation Bioelectronics
Chung, W. G., Kim, E., Kwon, Y. W., Lee, J., Lee, S., Jeong, I., & Park, J. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202307990 · Cited by 58
Lapp, H., Bruegmann, T., Malan, D., Friedrichs, S., Kilgus, C., Heidsieck, A., & Sasse, P. (2017) · Scientific Reports · doi:10.1038/s41598-017-09760-7 · Cited by 57
Novel Nano-Materials and Nano-Fabrication Techniques for Flexible Electronic Systems
Kang, K., Cho, Y., & Yu, K. J. (2018) · Micromachines · doi:10.3390/mi9060263 · Cited by 59
Cutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 58
Nayagam, D. A. X., Williams, R. A., Allen, P. J., Shivdasani, M. N., Luu, C. D., Rosa, C. M. S.-L., Finch, S. J., Ayton, L. N., Saunders, A. L., McPhedran, M., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0097182 · Cited by 57
SEIZURE ABATEMENT WITH SINGLE DC PULSES: IS PHASE RESETTING AT PLAY?
Osorio, I., & Frei, M. G. (2009) · International Journal of Neural Systems · doi:10.1142/s0129065709001926 · Cited by 57
Switched-capacitor based implantable low-power wireless microstimulating systems
Ghovanloo, M. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1693055 · Cited by 57
Model-based analysis and design of waveforms for efficient neural stimulation
Grill, W. M. (2015) · Progress in brain research · doi:10.1016/bs.pbr.2015.07.031 · Cited by 57
Popovych, O. V., Lysyansky, B., & Tass, P. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-01067-x · Cited by 57
Photoactive Organic Substrates for Cell Stimulation: Progress and Perspectives
Hopkins, J., Travaglini, L., Lauto, A., Cramer, T., Fraboni, B., Seidel, J., & Mawad, D. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800744 · Cited by 57
Eleftheriou, C. G., Zimmermann, J. B., Kjeldsen, H. D., David‐Pur, M., Hanein, Y., & Sernagor, E. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.018 · Cited by 57
A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56
Contractile force assessment methods for in vitro skeletal muscle tissues
Vesga-Castro, C., Aldazabal, J., Vallejo‐Illarramendi, A., & Paredes, J. (2022) · eLife · doi:10.7554/elife.77204 · Cited by 56
Lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation
Wang, Q., Zhang, Y., Xue, H., Zeng, Y., Lu, G., Fan, H., Jiang, L., & Wu, J. (2024) · Nature Communications · doi:10.1038/s41467-024-48250-z · Cited by 58
Safe Direct Current Stimulation to Expand Capabilities of Neural Prostheses
Fridman, G. Y., & Santina, C. C. D. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2245423 · Cited by 56
Lu, L., Mende, M., Yang, X., Körber, H., Schnittler, H., Weinert, S., Heubach, J. F., Werner, C., & Ravens, U. (2012) · Tissue Engineering Part A · doi:10.1089/ten.tea.2012.0135 · Cited by 56
Minnikanti, S., Skeath, P. R., & Peixoto, N. (2008) · Carbon · doi:10.1016/j.carbon.2008.11.045 · Cited by 56
Radivojević, M., Jäckel, D., Altermatt, M., Müller, J., Viswam, V., Hierlemann, A. R., & Bakkum, D. J. (2016) · Scientific Reports · doi:10.1038/srep31332 · Cited by 57
Lieberth, K., Romele, P., Torricelli, F., Koutsouras, D. A., Brückner, M., Mailänder, V., Gkoupidenis, P., & Blom, P. W. M. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100845 · Cited by 55
Safety of neural monitoring in thyroid surgery
Dionigi, G., Chiang, F., Dralle, H., Boni, L., Rausei, S., Rovera, F. A., Piantanida, E., Mangano, A., Barczyński, M., Randolph, G. W., et al. (2013) · International Journal of Surgery · doi:10.1016/s1743-9191(13)60031-x · Cited by 52
Kasi, H., Hasenkamp, W., Cosendai, G., Bertsch, A., & Renaud, P. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-44 · Cited by 55
Paneri, B., Adair, D., Thomas, C., Khadka, N., Patel, V., Tyler, W. J., Parra, L. C., & Bikson, M. (2016) · Brain stimulation · doi:10.1016/j.brs.2016.05.008 · Cited by 55
Self-citationOptimizing growth and post treatment of diamond for high capacitance neural interfaces
Tong, W., Fox, K. E., Zamani, A., Turnley, A. M., Ganesan, K., Ahnood, A., Cicione, R., Hamish Meffin, A., Prawer, S., Stacey, A. D., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.07.006 · Cited by 56
Organic bioelectronics in medicine
Löffler, S., Melican, K., Nilsson, K. P. R., & Richter‐Dahlfors, A. (2017) · Journal of Internal Medicine · doi:10.1111/joim.12595 · Cited by 58
Physics of Transcranial Direct Current Stimulation Devices and Their History
Truong, D. Q., & Bikson, M. (2018) · Journal of Ect · doi:10.1097/yct.0000000000000531 · Cited by 55
Self-citationOrganic Haptics: Intersection of Materials Chemistry and Tactile Perception
Lipomi, D. J., Dhong, C., Carpenter, C. W., Root, N., & Ramachandran, V. S. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906850 · Cited by 59
Gerges, M., Foldes, E. L., Ackermann, D. M., Bhadra, N., Bhadra, N., & Kilgore, K. L. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/6/066003 · Cited by 55
Lee, Y. J., Kim, H.-J., Do, S. H., Kang, J. Y., & Lee, S. H. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.06.169 · Cited by 54
Bierman, R. D., Safarians, G., Huang, J., Rajput, B., Chen, J. Y., Wang, Z. Z., & Seidlits, S. K. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202101577 · Cited by 58
Electrical Stimulation and Cellular Behaviors in Electric Field in Biomedical Research
Meng, S., Rouabhia, M., & Zhang, Z. (2021) · Materials · doi:10.3390/ma15010165 · Cited by 55
A CMOS retinal neurostimulator capable of focussed, simultaneous stimulation
Dommel, N., Wong, Y. T., Lehmann, T., Dodds, C. W. D., Lovell, N. H., & Suaning, G. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035006 · Cited by 54
Park, J.-S., Aziz, M. K., Li, S., Chi, T., Grijalva, S. I., Sung, J. H., Cho, H. C., & Wang, H. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2759220 · Cited by 55
The Electrochemistry of Charge Injection at the Electrode/Tissue Interface
Merrill, D. R. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_4 · Cited by 56
Self-citationA biomimetic electrical stimulation strategy to induce asynchronous stochastic neural activity
Formento, E., D’Anna, E., Gribi, S., Lacour, S. P., & Micera, S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba4fc · Cited by 57
Conducting Polymers in Neural Stimulation Applications
Zhou, D. D., Cui, X. T., Hines, A., & Greenberg, R. J. (2009) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_8 · Cited by 55
Alcaide, M. J., Taylor, A., Fjorback, M. V., Zachar, V., & Pennisi, C. P. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00087 · Cited by 53
Mayr, W., Krenn, M. J., & Dimitrijevic, M. R. (2016) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000382 · Cited by 53
A CMOS Current Steering Neurostimulation Array With Integrated DAC Calibration and Charge Balancing
Greenwald, E., Maier, C., Wang, Q., Beaulieu, R., Etienne‐Cummings, R., Cauwenberghs, G., & Thakor, N. V. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2609854 · Cited by 54
Wissel, K., Brandes, G., Pütz, N., Angrisani, G. L., Thieleke, J. P., Lenarz, T., & Ďurišin, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0196649 · Cited by 53
Organic Photovoltaic Pseudocapacitors for Neurostimulation
Han, M., Srivastava, S. B., Yıldız, E., Melikov, R., Sürme, S., Dogru-Yuksel, I. B., Kavaklı, İ. H., Şahin, A., & Nizamoğlu, S. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c11581 · Cited by 55
A Largely Deformable Surface Type Neural Electrode Array Based on PDMS
Chou, N., Yoo, S., & Kim, S. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2210560 · Cited by 52
Electrode assembly design for transcranial Direct Current Stimulation: A FEM modeling study
Kronberg, G., & Bikson, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346075 · Cited by 52
Self-citationJensen, R. J., & Rizzo, J. F. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035004 · Cited by 52
Abramian, M., Lovell, N. H., Morley, J. W., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035004 · Cited by 52
Recent advances in neural interfaces—Materials chemistry to clinical translation
Bettinger, C. J., Ecker, M., Kozai, T. D. Y., Malliaras, G. G., Meng, E. F., & Voit, W. (2020) · MRS Bulletin · doi:10.1557/mrs.2020.195 · Cited by 56
Ackermann, D. M., Bhadra, N., Foldes, E. L., Wang, X.-F., & Kilgore, K. L. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2071882 · Cited by 52
Metadata
- Authors
- Merrill, D. R., Bikson, M., & Jefferys, J. G. R.
- Affiliations
- University of Utah (US)
- City College of New York (US)
- University of Birmingham (GB)
- Corresponding author
- Merrill, Daniel R.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2005-02
- Volume
- 141
- Issue
- 2
- Pages
- 171-198
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2153787766
- Cited by
- 2,078
- References
- 159
- Citations by year
- 2026: 100 · 2025: 136 · 2024: 116 · 2023: 126 · 2022: 132 · 2021: 163 · 2020: 119 · 2019: 132 · 2018: 137 · 2017: 115 · 2016: 109 · 2015: 100 · 2014: 98 · 2013: 91 · 2012: 80
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Funders
- National Institutes of Health (5f32ns045454-03)
- National Institute of Neurological Disorders and Stroke (5F32NS045454)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- functional electrical stimulation, electrode-tissue interface, charge injection, Faradaic charge transfer, electrode potential, electrochemical reversibility, stimulation protocols, stimulation safety, tissue damage mechanisms, electrode damage, electrode materials
- MeSH terms
- Animals, Biomedical Engineering, Electric Stimulation, Electrochemistry, Electrodes, Electrolytes, Electrophysiology, Electric Stimulation Therapy, Equipment Design, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review