The DOI matches its Crossref record; 156 of the 159 references it cites were found in a registry or an index.
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Abstract
The physical basis for electrical stimulation of excitable tissue, as used by electrophysiological researchers and clinicians in functional electrical stimulation, is presented with emphasis on the fundamental mechanisms of charge injection at the electrode/tissue interface. Faradaic and non-Faradaic charge transfer mechanisms are presented and contrasted. An electrical model of the electrode/tissue interface is given. The physical basis for the origin of electrode potentials is given. Various methods of controlling charge delivery during pulsing are presented. Electrochemical reversibility is discussed. Commonly used electrode materials and stimulation protocols are reviewed in terms of stimulation efficacy and safety. Principles of stimulation of excitable tissue are reviewed with emphasis on efficacy and safety. Mechanisms of damage to tissue and the electrode are reviewed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, all data used in this study to fit and validate the model used symmetric, biphasic pulse trains, while other pulse shapes might lead to different neural or behavioral responses (Merrill et al., 2005).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Merrill et al., 2005
In the citing paper
“A critical aspect of electrical stimulation is its higher level of safety risk compared to recording electrical activity, which can result in both electrode and tissue damage.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [16]
In the citing paper
“Similarly, Merrill et al. noted that a narrow pulse is desirable to decrease occurrence of electrochemical reactions, and therefore reduce electrode degradation [2].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“In terms of electrode corrosion, however, slightly unbalanced biphasic pulses might be advantageous [2, 77].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [2]
In the citing paper
“Charge injection at an electrode occurs through capacitive charge transfer, with no electron transfer across the electrodeelectrolyte interface, and Faradaic charge transfer, where electron transfer and reduction and oxidation (redox) reactions occur [101], [114].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“To minimise potentially toxic redox reaction products, biphasic stimulation reverses the charge injection in a second phase of a stimulation pulse aiming to reverse Faradaic reactions.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Faradaic reactions where products are not available for the reverse reaction are not reversed, for example hydrolysis of water or 'water window' which places safety limits on electrode-electrolyte interface potentials [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“In a biphasic pulse neuron activation occurs at a lower threshold for cathodic (sink) currents [101], [119], compared to positive anodic (source) currents.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
In the citing paper
“Typical stimulation pulse widths range up to a few hundred μs , and current amplitudes vary from tens of μA to a few mA in peripheral nerve interfaces [9], [101].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [101]
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Nitric oxide: physiology, pathophysiology, and pharmacology.
Moncada, S., Palmer, R. M., & Higgs, E. A. (1991) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06663-3 · Cited by 15,525
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,150
Bliss, T. V. P., & Gardner-Medwin, A. R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010274 · Cited by 7,424
Ionic channels of excitable membranes
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90172-7 · Cited by 7,134
Beckman, J. S., Beckman, T. W., Chen, J., Marshall, P. A., & Freeman, B. A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.4.1620 · Cited by 7,029
The Electrical Double Layer and the Theory of Electrocapillarity.
Grahame, D. C. (1947) · Chemical Reviews · doi:10.1021/cr60130a002 · Cited by 3,324
Inhibition of Cell Division in Escherichia coli by Electrolysis Products from a Platinum Electrode
Rosenberg, B., Camp, L. V., & Krigas, T. (1965) · Nature · doi:10.1038/205698a0 · Cited by 3,052
Reactive Oxygen Species and the Central Nervous System
Halliwell, B. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb10990.x · Cited by 2,947
(1981) · Handbook of exploration geochemistry · doi:10.1016/b978-0-444-41930-9.50014-3 · Cited by 2,903
Flagged first, then by citations
3 of the 159 references couldn’t be matched to a known paper.
Research works printed but not linked: 5
- Bhargava A. Long-term effects of quasi-trapezoidal pulses on the structure and function of sacral anterior roots. M.S. thesis, Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 1993.
- Guoy, 1910, Constitution of the electric charge at the surface of an electrolyte, J Physique, 9, 457
- Kennedy, 1999, Neural activity during acquisition of cursor control in a locked-in patient, Soc Neurosci Abstr, 25, 894
- Rall, 1977, vol.1/part 1
- Sevanian, 1988, Lipid peroxidation, membrane damage, and phospholipase A2 action: cellular antioxidant defense mechanisms, CRC Rev., II, 77
Cited by
Sorted by citations
Items 501–600 of 1,003
Effects of frequency-dependent membrane capacitance on neural excitability
Howell, B., Medina, L. E., & Grill, W. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056015 · Cited by 39
van der Grinten, M., de Ruyter van Steveninck, J., Lozano, A., Pijnacker, L., Rueckauer, B., Roelfsema, P., van Gerven, M., van Wezel, R., Güçlü, U., & Güçlütürk, Y. (2024) · eLife · doi:10.7554/elife.85812 · Cited by 39
“For instance, all data used in this study to fit and validate the model used symmetric, biphasic pulse trains, while other pulse shapes might lead to different neural or behavioral responses ( Merrill et al., 2005 ).”
MethodElectrical Stimulation of Cells: Drivers, Technology, and Effects
Kadan-Jamal, K., Wronowski, F., Jin, A. T., Naegele, T. E., Montes, V. R., Tao, X., Dominguez‐Alfaro, A., Lee, C., & Malliaras, G. G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00468 · Cited by 39
A Tripolar Current-Steering Stimulator ASIC for Field Shaping in Deep Brain Stimulation
Valente, V., Demosthenous, A., & Bayford, R. H. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2171036 · Cited by 39
Yousif, N., Purswani, N., Bayford, R. H., Nandi, D., Bain, P. G., & Liu, X. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.026 · Cited by 38
Electrical conditioning of adipose‐derived stem cells in a multi‐chamber culture platform
Pavesi, A., Soncini, M., Zamperone, A., Pietronave, S., Médico, E., Redaelli, A. C. L., Prat, M., & Fiore, G. B. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25201 · Cited by 39
Tektürk, P., Erdoğan, E. T., Kurt, A., Kocagöncü, E., Kucuk, Z., Kınay, D., Yapıcı, Z., Aksu, S., Baykan, B. B., & Karamürsel, S. (2016) · Epileptic Disorders · doi:10.1684/epd.2016.0796 · Cited by 39
Ledo, A., Lourenço, C. F., Laranjinha, J. A. N., Brett, C. M. A., Gerhardt, G. A., & Barbosa, R. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03772 · Cited by 40
Zhao, Y., Liu, H., Bhonsle, S. P., Wang, Y., Davalos, R. V., & Yao, C. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0562-9 · Cited by 39
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
Personality and Authenticity in Light of the Memory-Modifying Potential of Optogenetics
Zawadzki, P., & Adamczyk, A. K. (2021) · AJOB Neuroscience · doi:10.1080/21507740.2020.1866097 · Cited by 41
Advances in large-scale electrophysiology with high-density microelectrode arrays
Schröter, M. S., Cardes, F., Bui, C.-V. H., Dodi, L. D., Gänswein, T., Bartram, J., Sadiraj, L., Hornauer, P., Kumar, S. S., Pascual-Garcia, M., et al. (2025) · Lab on a Chip · doi:10.1039/d5lc00058k · Cited by 48
Di, L., Wang, L.-P., Lu, Y.-N., He, L., Lin, Z., Wu, K., Ren, Q. S., & Wang, J.-Y. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.009 · Cited by 38
Habib, A. G., Cameron, M. A., Suaning, G. J., Lovell, N. H., & Morley, J. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036013 · Cited by 38
Ho, D., Zou, J., Chen, X., Munshi, A. M., Smith, N. M., Agarwal, V., Hodgetts, S. I., Plant, G. W., Bakker, A. J., Harvey, A. R., et al. (2015) · ACS Nano · doi:10.1021/nn506607x · Cited by 38
Zheng, Y., Jiang, Z., Ping, A., Zhang, F., Zhu, J., Wang, Y., Zhu, W., & Xu, K. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2894746 · Cited by 38
Harris, A. R., Carter, P., Cowan, R., & Wallace, G. G. (2021) · ChemElectroChem · doi:10.1002/celc.202001574 · Cited by 38
Laskin, J., Waheed, Z., Thorogood, N. P., Nightingale, T. E., & Noonan, V. K. (2022) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2022.01.161 · Cited by 38
Design of electrical stimulation bioreactors for cardiac tissue engineering
Tandon, N., Marsano, A., Cannizzaro, C., Joel Voldman, B., & Vunjak‐Novakovic, G. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649983 · Cited by 38
Muguet, I., Maziz, A., Mathieu, F., Mazenq, L., & Larrieu, G. (2023) · Advanced Materials · doi:10.1002/adma.202302472 · Cited by 38
Locally optimal extracellular stimulation for chaotic desynchronization of neural populations
Wilson, D. D., & Moehlis, J. (2014) · Journal of Computational Neuroscience · doi:10.1007/s10827-014-0499-3 · Cited by 37
Boyle, P. M., Karathanos, T. V., & Trayanova, N. A. (2014) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2014.10.004 · Cited by 37
Multisite Delayed Feedback for Electrical Brain Stimulation
Popovych, O. V., & Tass, P. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00046 · Cited by 38
Loizos, K., Marc, R. E., Humayun, M. S., Anderson, J. R., Jones, B. W., & Lazzi, G. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2832055 · Cited by 36
Micro-Coil Design Influences the Spatial Extent of Responses to Intracortical Magnetic Stimulation
Lee, S. W., Thyagarajan, K., & Fried, S. I. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2877713 · Cited by 37
Enhanced spinal cord microstimulation using conducting polymer-coated carbon microfibers
Vara, H., & Collazos-Castro, J. E. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.037 · Cited by 37
Robust enhancement of motor sequence learning with 4 mA transcranial electric stimulation
Hsu, G., Shereen, A. D., Cohen, L. G., & Parra, L. C. (2022) · Brain stimulation · doi:10.1016/j.brs.2022.12.011 · Cited by 34
Dynamics of the Subthalamo-pallidal Complex in Parkinson’s Disease During Deep Brain Stimulation
Modolo, J., Henry, J., & Beuter, A. C. (2008) · Journal of Biological Physics · doi:10.1007/s10867-008-9095-y · Cited by 37
Bioelectronic Neural Interfaces: Improving Neuromodulation Through Organic Conductive Coatings
Duan, W., Robles, U. A. A., Poole-Warren, L. A., & Esrafilzadeh, D. (2023) · Advanced Science · doi:10.1002/advs.202306275 · Cited by 36
Design andin vivoevaluation of more efficient and selective deep brain stimulation electrodes
Howell, B. L., Huynh, B., & Grill, W. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046030 · Cited by 38
Multifunctional Neural Interfaces for Closed‐Loop Control of Neural Activity
Chapman, C. A. R., Goshi, N., & Şeker, E. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703523 · Cited by 38
Molybdenum coated SU-8 microneedle electrodes for transcutaneous electrical nerve stimulation
Soltanzadeh, R., Afsharipour, E., Shafai, C., Anssari, N., Mansouri, B., & Moussavi, Z. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0241-9 · Cited by 36
Safety Studies for a 44-Channel Suprachoroidal Retinal Prosthesis: A Chronic Passive Study
Abbott, C. J., Nayagam, D. A. X., Luu, C. D., Epp, S. B., Williams, R. A., Rosa, C. M. S.-L., Villalobos, J., McGowan, C. C., Shivdasani, M. N., Burns, O., et al. (2018) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.17-23086 · Cited by 38
Wang, R., Abukhalaf, Z., Javan‐Khoshkholgh, A., Wang, T. H., Sathar, S., Du, P., Angeli, T. R., Cheng, L. K., O’Grady, G., Paskaranandavadivel, N., et al. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2018.2812105 · Cited by 36
Eles, J. R., Stieger, K. C., & Kozai, T. D. Y. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc29c · Cited by 36
Deep brain stimulation macroelectrodes compared to multiple microelectrodes in rat hippocampus
Desai, S. A., Gutekunst, C., Potter, S. M., & Gross, R. E. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00016 · Cited by 38
Local glutamate release in the rat ventral lateral thalamus evoked by high-frequency stimulation
Agnesi, F., Blaha, C. D., Lin, J. D., & Lee, K. H. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026009 · Cited by 36
Lozano, R., Gilmore, K. J., Thompson, B. C., Stewart, E. M., Waters, A. M., Romero‐Ortega, M. I., & Wallace, G. G. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.08.006 · Cited by 35
PEDOT:PSS-coated platinum electrodes for neural stimulation
Dijk, G., Pas, J., Marković, K., Ščančar, J., & O'Connor, R. P. (2023) · APL Bioengineering · doi:10.1063/5.0153094 · Cited by 42
Prosthetic vision: devices, patient outcomes and retinal research
Hadjinicolaou, A. E., Hamish Meffin, A., Maturana, M. I., Cloherty, S. L., & Ibbotson, M. R. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12342 · Cited by 38
Continuous Direct Current Nerve Block Using Multi Contact High Capacitance Electrodes
Vrabec, T. L., Bhadra, N., Acker, G. M. V., Bhadra, N., & Kilgore, K. L. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2589541 · Cited by 34
Cisnal, A., Fraile, J. C., Turiel, J. P., Muñoz-Martínez, V. F., Müller, C., & Ihmig, F. R. (2018) · Sensors · doi:10.3390/s18124152 · Cited by 35
Son, J.-Y., & Cha, H. (2020) · IEEE Access · doi:10.1109/access.2020.3012028 · Cited by 35
Photovoltaic neurointerface based on aluminum antimonide nanocrystals
Han, M., Jalali, H. B., Yıldız, E., Qureshi, M. H., Şahin, A., & Nizamoğlu, S. (2021) · Communications Materials · doi:10.1038/s43246-021-00123-4 · Cited by 35
Nanoengineering InP Quantum Dot-Based Photoactive Biointerfaces for Optical Control of Neurons
Karatum, O., Aria, M. M., Eren, G. O., Yıldız, E., Melikov, R., Srivastava, S. B., Sürme, S., Dogru-Yuksel, I. B., Jalali, H. B., Ülgüt, B., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.652608 · Cited by 36
Electroresponsive Hydrogels for Therapeutic Applications in the Brain
Khan, Z. M., Wilts, E. M., Vlaisavljevich, E., Long, T. E., & Verbridge, S. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202100355 · Cited by 37
Alteration of GABAergic neurotransmission by pulsed infrared laser stimulation
Feng, H. J., Kao, C., Gallagher, M. J., Jansen, D., Mahadevan-Jansen, A. M., Konrad, P. E., & Macdonald, R. L. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.014 · Cited by 35
Quasi-monopolar electrical stimulation of the retina: a computational modelling study
Abramian, M., Lovell, N. H., Habib, A., Morley, J. W., Suaning, G. J., & Dokos, S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/025002 · Cited by 35
Insect-machine interface: A carbon nanotube-enhanced flexible neural probe
Tsang, W. M., Stone, A. L., Otten, D. M., Aldworth, Z., Daniel, T. L., Hildebrand, J. G., Levine, R. B., & Joel Voldman, B. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.11.026 · Cited by 35
Cogan, S. F., Ehrlich, J., Plante, T. D., Gingerich, M. D., & Shire, D. B. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2050690 · Cited by 35
Vincent, M., Rossel, O., Hayashibe, M., Herbet, G., Duffau, H., Guiraud, D., & Bonnetblanc, F. (2015) · Reviews in the Neurosciences · doi:10.1515/revneuro-2015-0029 · Cited by 38
Eliciting naturalistic cortical responses with a sensory prosthesis via optimized microstimulation
Choi, J. S., Brockmeier, A. J., McNiel, D., von Kraus, L. M., Príncipe, J. C., & Francis, J. T. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056007 · Cited by 35
Gurtubay, I. G., Pérez-Rodríguez, D. R., Fernandez, E., Librero, J., Calvo, D., Bermejo, P. E., Osorio, C. P., & Lopez, M. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1096865 · Cited by 33
Electrical neurostimulation with imbalanced waveform mitigates dissolution of platinum electrodes
Kumsa, D., Hudak, E. M., Montague, F. W., Kelley, S. C., Untereker, D. F., Hahn, B. P., Condit, C., Cholette, M., Lee, H., Bardot, D. M., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/054001 · Cited by 36
Reversible Conduction Block in Peripheral Nerve Using Electrical Waveforms
Bhadra, N., Vrabec, T. L., Bhadra, N., & Kilgore, K. L. (2017) · Bioelectronics in Medicine · doi:10.2217/bem-2017-0004 · Cited by 34
Biocompatible Quantum Funnels for Neural Photostimulation
Jalali, H. B., Karatum, O., Melikov, R., Dikbas, U. M., Sadeghi, S., Yıldız, E., Dogru-Yuksel, I. B., Eren, G. O., Ayva, C. E., Şahin, A., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b01697 · Cited by 34
Hybrid graphene electrode for the diagnosis and treatment of epilepsy in free-moving animal models
Lim, J., Lee, S., Kim, J., Hong, J., Lim, S., Kim, K., Kim, J., Yang, S., Yang, S., & Ahn, J. (2023) · NPG Asia Materials · doi:10.1038/s41427-023-00464-1 · Cited by 34
Vrabec, T. L., Bhadra, N., Wainright, J. S., Bhadra, N., Franke, M., & Kilgore, K. L. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1385-5 · Cited by 34
Burst-Modulated Waveforms Optimize Electrical Stimuli for Charge Efficiency and Fiber Selectivity
Qing, K. Y., Ward, M. P., & Irazoqui, P. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2421732 · Cited by 34
Suaning, G. J., Schüettler, M., Ordonez, J. S., & Lovell, N. H. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369597 · Cited by 34
Characterization of Electrical Stimulation Electrodes for Cardiac Tissue Engineering
Tandon, N. M., Cannizzaro, C., Figallo, E., Joel Voldman, B., & Vunjak‐Novakovic, G. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259747 · Cited by 34
Vincent, M., Guiraud, D., Duffau, H., Mandonnet, E., & Bonnetblanc, F. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.07.402 · Cited by 35
Phosphene perceptions and safety of chronic visual cortex stimulation in a blind subject
Niketeghad, S., Muralidharan, A., Patel, U., Dorn, J. D., Bonelli, L., Greenberg, R. J., & Pouratian, N. (2020) · Journal of Neurosurgery · doi:10.3171/2019.3.jns182774 · Cited by 33
Low-Power and Eco-Friendly Temperature Sensor Based on Gelatin Nanocomposite
Landi, G., Granata, V., Germano, R., Pagano, S., & Barone, C. (2022) · Nanomaterials · doi:10.3390/nano12132227 · Cited by 33
Lehmkuhle, M. J., Bhangoo, S. S., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90844.2008 · Cited by 33
Integrated electrode and high density feedthrough system for chip-scale implantable devices
Green, R. A., Guenther, T., Jeschke, C., Jaillon, A., Yu, J. F., Dueck, W. F., Lim, W. W., Henderson, W. C., Vanhoestenberghe, A., Lovell, N. H., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.054 · Cited by 33
Current-Controlled Electrical Point-Source Stimulation of Embryonic Stem Cells
Chen, M. Q., Xie, X., Wilson, K. D., Sun, N., Wu, J. C., Giovangrandi, L., & Kovacs, G. T. A. (2009) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-009-0096-0 · Cited by 33
Gilmour, A. D., Woolley, A. J., Poole-Warren, L. A., Thomson, C. E., & Green, R. A. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.03.011 · Cited by 34
Mechanisms of electrical vasoconstriction
Brinton, M. R., Mandel, Y., Schachar, I. H., & Palanker, D. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0390-y · Cited by 33
Electrotaxis of Glioblastoma and Medulloblastoma Spheroidal Aggregates
Lyon, J. G., Carroll, S. L., Mokarram, N., & Bellamkonda, R. V. (2019) · Scientific Reports · doi:10.1038/s41598-019-41505-6 · Cited by 32
Gage, G. J., Stoetzner, C. R., Richner, T. J., Brodnick, S. K., Williams, J. C., & Kipke, D. R. (2012) · Journal of Visualized Experiments · doi:10.3791/3565 · Cited by 33
Energy Efficient Neural Stimulation: Coupling Circuit Design and Membrane Biophysics
Foutz, T. J., Ackermann, D. M., Kilgore, K. L., & McIntyre, C. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051901 · Cited by 33
Carbon Nanotube Yarns for Deep Brain Stimulation Electrode
Jiang, C., Li, L., & Hao, H. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2165733 · Cited by 33
A Miniaturized, Programmable Deep-Brain Stimulator for Group-Housing and Water Maze Use
Pinnell, R., de Vasconcelos, A. P., Cassel, J., & Hofmann, U. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00231 · Cited by 33
Selective recruitment of cortical neurons by electrical stimulation
Komarov, M., Malerba, P., Golden, R., Nunez, P. L., Halgren, E., & Bazhenov, M. (2019) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1007277 · Cited by 33
Tandon, N. M., Cimetta, E., Villasante, A., Kupferstein, N., Southall, M. D., Fassih, A., Xie, J., Sun, Y., & Vunjak‐Novakovic, G. (2013) · Experimental Cell Research · doi:10.1016/j.yexcr.2013.09.016 · Cited by 33
Semiconducting electrodes for neural interfacing: a review
Ahnood, A., Chambers, A., Gelmi, A. A., Yong, K., & Kavehei, O. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00830k · Cited by 33
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 38
Extending Phase Reduction to Excitable Media: Theory and Applications
Wilson, D. D., & Moehlis, J. (2015) · SIAM Review · doi:10.1137/140952478 · Cited by 32
Daneshzand, M., Faezipour, M., & Barkana, B. D. (2017) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2017.00073 · Cited by 32
New era of optogenetics: from the central to peripheral nervous system
Xu, X., Mee, T., & Jia, X. (2020) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.1080/10409238.2020.1726279 · Cited by 32
Recent advances in electronic devices for monitoring and modulation of brain
Kwon, Y. W., Jun, Y. S., Park, Y., Jang, J., & Park, J. (2021) · Nano Research · doi:10.1007/s12274-021-3476-y · Cited by 35
Jung, D., Junek, G. V., Park, J.-S., Kumashi, S., Wang, A. Y., Li, S., Grijalva, S. I., Fernandez, N., Cho, H. C., & Wang, H. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3085571 · Cited by 33
Rocha, I., Cerqueira, G., Penteado, F. V., & de Torresi, S. I. C. (2021) · Frontiers in Medical Technology · doi:10.3389/fmedt.2021.670274 · Cited by 32
García-Sánchez, T., Azan, A., Leray, I., Rosell, J., Bragós, R., & Mir, L. M. (2015) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2015.05.018 · Cited by 32
Lu, Y., Yan, Y., Chai, X., Ren, Q., Chen, Y., & Li, L. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036022 · Cited by 32
Ramasubbu, C., Flagg, A., & Williams, K. (2013) · Current Pain and Headache Reports · doi:10.1007/s11916-012-0315-6 · Cited by 32
Deku, F., Joshi‐Imre, A., Mërtiri, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0401809jes · Cited by 31
Physiological principles of electrical stimulation
Bhadra, N. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-101-6.00002-1 · Cited by 33
Prime, D., Woolfe, M., O’Keefe, S. G., Rowlands, D. D., & Dionisio, S. A. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108639 · Cited by 31
Neuroprosthesis for individuals with spinal cord injury
Kilgore, K. L., Anderson, K. D., & Peckham, P. H. (2020) · Neurological Research · doi:10.1080/01616412.2020.1798106 · Cited by 32
Layer-specific parameters of intracortical microstimulation of the somatosensory cortex
Urdaneta, M. E., Kunigk, N. G., Delgado, F., Fried, S. I., & Otto, K. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abedde · Cited by 31
Low-frequency electrical stimulation reduces cortical excitability in the human brain
Manzouri, F., Meisel, C., Kunz, L., Dümpelmann, M., Stieglitz, T., & Schulze‐Bonhage, A. (2021) · NeuroImage Clinical · doi:10.1016/j.nicl.2021.102778 · Cited by 31
Dijk, G., Ruigrok, H. J., & O'Connor, R. P. (2021) · Advanced Materials Interfaces · doi:10.1002/admi.202100214 · Cited by 31
Robbins, E. M., Castagnola, E., & Cui, X. T. (2021) · iScience · doi:10.1016/j.isci.2022.104845 · Cited by 31
Towards a Switched-Capacitor based Stimulator for efficient deep-brain stimulation
Vidal, J. G., & Ghovanloo, M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626290 · Cited by 31
Musa, S., Rand, D. R., Bartic, C., Eberle, W., Nuttin, B., & Borghs, G. (2011) · Analytical Chemistry · doi:10.1021/ac103037u · Cited by 32
Ionotactile Stimulation: Nonvolatile Ionic Gels for Human–Machine Interfaces
Root, S. E., Carpenter, C. W., Kayser, L. V., Rodriquez, D., Davies, D., Wang, S., Tan, S. T. M., Meng, Y. S., & Lipomi, D. J. (2018) · ACS Omega · doi:10.1021/acsomega.7b01773 · Cited by 31
Miniature wireless recording and stimulation system for rodent behavioural testing
Pinnell, R., Dempster, J., & Pratt, J. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066015 · Cited by 30
Wilks, S. J., Hara, S. A., Ross, E. K., Nicolai, E. N., Pignato, P. A., Cates, A. W., & Ludwig, K. A. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00438 · Cited by 32
Metadata
- Authors
- Merrill, D. R., Bikson, M., & Jefferys, J. G. R.
- Affiliations
- University of Utah (US)
- City College of New York (US)
- University of Birmingham (GB)
- Corresponding author
- Merrill, Daniel R.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2005-02
- Volume
- 141
- Issue
- 2
- Pages
- 171-198
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2153787766
- Cited by
- 2,078
- References
- 159
- Citations by year
- 2026: 100 · 2025: 136 · 2024: 116 · 2023: 126 · 2022: 132 · 2021: 163 · 2020: 119 · 2019: 132 · 2018: 137 · 2017: 115 · 2016: 109 · 2015: 100 · 2014: 98 · 2013: 91 · 2012: 80
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Funders
- National Institutes of Health (5f32ns045454-03)
- National Institute of Neurological Disorders and Stroke (5F32NS045454)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- functional electrical stimulation, electrode-tissue interface, charge injection, Faradaic charge transfer, electrode potential, electrochemical reversibility, stimulation protocols, stimulation safety, tissue damage mechanisms, electrode damage, electrode materials
- MeSH terms
- Animals, Biomedical Engineering, Electric Stimulation, Electrochemistry, Electrodes, Electrolytes, Electrophysiology, Electric Stimulation Therapy, Equipment Design, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›